Absorption Dynamometer
Understanding and Using a Typical Absorption Dynamometer
Introduction
A dynamometer is a device used to measure the torque and rotational speed of a rotating
machine. There are three basic types in use: absorption, driving and transmission
dynamometers. Absorption dynamometers dissipate energy as torque is measured and are
particularly useful for measuring the torque developed by power sources such as internal
combustion engines or electric motors. Driving dynamometers are used to measure the torque
required to operate such devices as pumps, compressors, or IC engines being motored for the
purpose of measuring friction losses (e.g. Spintrons). Transmission dynamometers are used to
measure the torque within or between machines.
Theory
The simplest type of absorption dynamometer is the pony brake which depends on dry friction
for converting mechanical energy into thermal energy. A water brake uses fluid friction rather
than dry friction for dissipating the input energy. Trunion bearings support the dynamometer
housing allowing it to rotate freely except for the restraint imposed by a reaction arm. A load cell
measures the force at the end of the reaction arm at a known radius r. Torque is then computed
by
= Fr
where is the torque and F is the force measured at radius r. Since the angular speed is
measured, power is determined as
ERB,September 2001
19
19
P
b
=
where P
b
is power and is rotational speed in radians per second.
This measured power can be corrected to standard pressure, temperature, and humidity with
std
means
vmeans means
vstd std
bc
T
T
P P
P P
P
|
|
.
|
\
|
=
Where P
bc
is the corrected engine power. P
std
and T
std
are the pressure and temperature to
which the measured values are to he corrected, P
vstd
is the partial pressure of the water vapor in
the standard
Atmosphere, P
vmeans
is the measured partial pressure of the water vapor in the air inducted into
the engine, P
means
and T
means
are the pressure and temperature of the air in the test cell.
An important measure of engine efficiency which can be determined using the dynamometer is
brake specific fuel consumption (BSFC) which is given as follows
BSFC =
b
f
P
m
Where
f
m is the fuel mass flow rate.
Since the mass flow rate of the air entering the engine (m
f
) is measured, an overall efficiency, ,
can he calculated as
LHV m
P
f
bc
1
=
where LHV is the lower heating value of the fuel. This is sometimes called fuel conversion
efficiency.
The parameter used to measure the effectiveness of an engines induction system is volumetric
efficiency. The volumetric efficiency, e
v
, of an engine is defined as the actual mass of air
drawn into the displacement volume during the intake stroke divided by the mass of air that
would occupy the same volume if it were at the temperature and pressure of air outside the
engine. Volumetric efficiency can be calculated by
2
s d i
f a
v
R v
m m
e
+
=
where
a
m is the mass flow rate of air, V
d
is the displacement volume. R
s,
is the engine rotational
speed in revolutions per unit Lime and
i
is the density of the incoming air. The two in the above
equation is present only for four stroke engines.
A parameter used to scale out the effect of engine displacement is brake mean effective
pressure, bmep, which is defined as net work per cycle per unit displacement volume. For a
four-stroke engine bmep is given by
ERB,September 2001
20
20
Bmep =
2
s d
bc
R V
P
Apparatus
The hardware consists of a 355 in Chevrolet small block engine, a Superflow SF-901
dynamometer, and a data logging computer.
Procedure
WARNING: The dynamometer will be operated by our trained technician, only.
I. Initial Set Up Procedure
A. Determine the specific gravity of the gasoline.
1. Fill the 1000 ml flask with gasoline. Place the hygrometer in the flask and read
the specific gravity (where the surface intersects the hygrometer scale.)
B. Determine the relative humidity.
1. Use the sling psychrometer to determine the wet bulb and dry bulb
temperatures.
2. Use a psychrometric chart to determine the partial pressure of the atmospheric
vapor.
II. Engine Room Set Up Procedure
A. Open valve V1 between the main water line and the engines water supply tank. The valve
V1 is located on the wall opposite the door (yellow handle). The engines water supply tank
ST is attached to the front of the engine; it is black and has a cylindrical shape.
B. Close drain valve DV on the engine water supply tank ST and open valve V2 between valve
V1 and the supply tank ST. Valve V2 and the drain valve DV are located below the tank. The
drain valve is on the right as you face the engine from the front and valve V12 is on the left.
ERB,September 2001
21
21
C. Fill supply rank ST with water to a level above the engine. Use the sight glass on the side of
ST to determine the water height.
D. Check the red fuel tank located on the wall opposite the window for fuel.
E. Turn the room fan on using the switch next to the fan. The fan and switch are on the wall
opposite the window.
III. Dynamometer Set Up and Operating Procedure
A. Turn on the power to the dynamometer and turn on the computer and printer that are
connected to the computer.
B. Set the minimum RPM setting (on the dynamometer) to 2500 rpm and the maximum
RPM setting to 4500 rpm. These dial in as 250 and 450.
C. The Command Directory will appear on the screen. In order to enter the vapor pressure
and fuel specific weight measured above, hit the H key to go to the help screen. Select
I for the Data Input screen containing all of the default settings for the engine. Scroll
down (using the Return key) to get to the settings for water vapor pressure and fuel
specific weight and input the measured values. Change the other settings as necessary
using this menu. Return to the Main Menu by typing ctrl c.
D. On the dynamometer, set Load Control to Manual and turn the load dial to the lowest
setting (fully clockwise). Turn on the fuel pump and set the hand throttle to its lowest
setting (i.e., in the back position).
E. Press the starter button to start the engine.
F. Visually monitor the dynamometer on the computer screen. From the Help Screen, type
I From the Command Directory hit esc. This will put you into the Input Menu which
allows direct monitoring of temperatures, pressured, torques. etc., as each test is run.
G. Allow the engine to warm up until oil temperature is at least 150 F and water temperature
is 150 F. These can be read from the Input Menu.
H. Procedure for performing an acceleration test.
1 Turn the Test Select knob on the dynamometer to Acceleration.
2 Turn the Auto Test Rate knob to 200.
3 Turn on the Servo.
4 Push the hand throttle to the wide open position (i.e., the up position).
5 Based on the settings chosen in step B and step H.2, the engine speed will
automatically from 2500 to 4500 rpm at a rare of 200 rpm/s.
6 After the highest speed is reached, the engine will automatically throttle down.
When this occurs, pull the hand throttle to the back position.
7 Once the engine has returned to idling speed, allow several minutes for cool
down before turning off the engine. Turn off the fuel pump and ignition switch
on the console.
8 Go to the Main Menu (hit ctrl + c) and select k for keep. This will save all the
data from the acceleration test.
ERB,September 2001
22
22
I. Use the Command Directory to select U to retrieve the stored data files. Type in the tile
name and hit enter. Select the type of analysis you want.
J. At the conclusion of the experiment, turn off the supply water to the engine, turn off the
exhaust fan, turn off the dynamometer, computer and printer, drain and return to storage
any unused gasoline, and properly dispose of used rags.
Report
Using a memo format (which assumes the person youre submitting the report to is familiar with
the apparatus and procedure) submit a report which includes the following.
1. Calculate:
brake specific fuel consumption,
fuel conversion efficiency,
volumetric efficiency and
brake mean effective pressure
at 2000 rpm, at the torque peak, and at the power peak.
Show all calculations with units cancellation. Discuss the results.
2. Include in your report a copy of the plot of power and torque vs. engine speed and
comment on any anomalies that you observe.
ERB,September 2001
23
23
Active Expansion Devices
Part I, Automatic Expansion Valve (Pressure Regulator)
The purpose of this experiment is to familiar with the function and operation of an automatic
expansion valve of a refrigeration system.
Introduction:
Refrigeration works on the principle of heat absorption due to the evaporation of refrigerant. It is
the latent heat of evaporation that gives the refrigerating effect. Liquid refrigerant is evaporated
by passing it from a high-pressure region through a throttling valve to reduce its saturation
pressure to a lower level, and reduce its saturation temperature. The degree of cooling can be
controlled by controlling the amount of refrigerant passing into the low-pressure region. The
throttling valves that control the refrigerant flow into the low-pressure region are called metering
devices. Fig. 1 shows a schematic drawing of an ideal vapor-compression refrigeration cycle.
The automatic expansion valve is known as a constant pressure valve. It implies that it holds
the pressure in the evaporator at a constant level regardless of load. In this way the load on the
compressor also remains about the same. Fig. 2 is a schematic drawing of an automatic
expansion valve.
ERB,September 2001
24
24
Note: Figure 2 does not precisely resemble the hardware in the lab.
The bellows of diaphragm of the AXV is actuated by the pressure in the evaporator (low side). A
rise in suction pressure due to increased load causes the diaphragm to expand and reduce the
opening of the valve seat; this restricts the flow of liquid refrigerant to the evaporator and brings
the suction pressure back to its original state.
As the pressure in the evaporator decreases, the spring force opens the valve seat and allows
more liquid refrigerant to be admitted to the evaporator. (Reducing the head pressure and
increasing the suction pressure.) The control pressure is set by the adjusting screw. In this
automatic expansion valve, the refrigerant flow is controlled only by the pressure in the
evaporator.
ERB,September 2001
25
25
Apparatus:
Model 9001 Brodhead-Garrett Basic Refrigeration Unit.
Refer to detailed photos in the Capillary Tube Experiment
Procedure:
A. Adjustment
1. Put system in cooling cycle, Open AXV with TXV and CTV closed. Close LRB, open LRI and
LRK.
2. Switch main power on, set evaporator fan on low and the condenser fan on high and start
the compressor.
3. Remove cap from the bottom of the AXV and turn
the adjusting screw (clockwise for increase
pressure and counter-clockwise for decrease
pressure) until suction pressure reaches 8 psi.
Allow 10 minutes for the system to stabilize before
taking data.
4. Record suction pressure, head pressure,
refrigerant flow rate, and refrigerant temperature
before and after the evaporator. (see data sheet.)
5. Adjust the AXV by turning the adjusting screw to a
suction pressure of 11 psi. Wait 5 minutes and
record the suction pressure, head pressure,
refrigerant flow rate, and refrigerant temperature before and after the evaporator.
6. Repeat procedure 5 for four more suction pressures.
B. Effect of Increased Load
ERB,September 2001
26
26
1. Turn the evaporator fan on high. Wait five minutes and record:
Suction Pressure ___________
Head Pressure ____________
Flow Rate ___________
2. Turn compressor off. Wait five minutes and record:
Suction Pressure ___________
Head Pressure ___________
Jump to Part II
or Shut Down:
Close LRB and LRK. With LRI open, operate until the low side pressure falls to about 0 psi.
Close LRV. Then, open LRB and turn the compressor and fans off.
Results:
1. Calculate cooling effect of the evaporator Qdot = Mdot refrigerant (h)
2. Exercises:
a. Explain what happens in an automatic expansion valve (AXV), when the load is
increased in a refrigeration system.
b. What causes the needle valve to close in an automatic expansion valve?
c. For each data set, what was P?
ERB,September 2001
27
27
Data Sheet
Date:
Suction Pressure (psig)
Head Pressure (psig)
Pressure After Exp. Valve (psig)
Refrig. Temp. Before Evaporator (F)
Refrig. Temp. After Evaporator (F)
Refrig. Temp. Before Condenser (F)
Refrig. Temp. After Condenser (F)
Refrigerant Flow Rate (PPM)
ERB,September 2001
28
28
Part II, Thermostatic Expansion Valve (TXV)
The purpose of this experiment is to familiar, with function and operation of a thermostatic
expansion valve of a refrigeration system.
Introduction:
The Thermostatic Expansion Valve (TXV) is a temperature
controlled expansion valve. It automatically adjusts to varying load
and maintains maximum efficiency at all times. The schematic
diagram illustrating the operation of a typical thermostatic
expansion valve is given in Fig. 1. This valve maintains constant
superheat (Ti - T
2
) in the evaporator. The difference between this
valve and the automatic expansion valve is that a thermal bulb
connected to the valve by a small capillary tube is attached to the
suction line between the evaporator and compressor. The thermal
bulb is partially filled with liquid refrigerant usually the same as
that used in the system. The thermal bulb is attached to the
suction line so that any change in load will change in temperature of the suction line and also
the temperature of the thermal bulb. Under an increased load, the refrigerant boils away more
rapidly in the evaporator. This in turn will cause a greater superheat at the evaporator outlet.
The higher temperature produces a higher pressure within the thermal bulb, and causes the
diaphragm to expand and force the needle valve seat to open. As a result more liquid refrigerant
is allowed to enter the evaporator.
ERB,September 2001
29
29
Apparatus:
Model 9001 Brodhead-Garrett Basic Refrigeration Unit.
Procedure:
1. To operate the TXV: close LRB, open LRI and LRK , open TXV, close AXV and CTV.
2. Put both the condenser fan and evaporator fan on high, turn compressor to on position and
switch main power on.
3. After letting the system run for 5 minutes, measure and record suction pressure, head
pressure, refrigerant flow rate, and refrigerant temperature before and after evaporator Make
a preliminary determination of the superheat, which is (T
1
- T
2
).
TXV
Where:
T
1
= suction line temperature at thermal bulb (TC #7)
T
2
= saturation temp. of low side pressure. (TC #6)
4. Turn the evaporator fan to low and wait for 10 min.
before recording the information listed in step 3.
5. Turn the evaporator fan off and wait about 10 min.
and record the same information as in step 3.
6. Shut the compressor off and record suction and head
pressure after waiting 5 minutes
Shut Down:
Close LRB and LRK. With LRI open, operate until the low
side pressure falls to about 0 psi. Close LRV. Then, open
LRB and turn the compressor and fans off.
.
ERB,September 2001
30
30
Result:
1. Calculate cooling effect of the evaporator:
Qdot = Mdot refrigerant ( h)
2. Exercises:
a. Discuss what happens in the evaporator when the load is decreased and how the TXV
would compensate.
b. What happens to the pressure across the TXV when the compressor is turned off?
c. Determine the superheat of the TXV for evaporator fan on high and low.
d. Are the superheats the same? Should they be same? Why?
e. What happened to the suction pressure, head pressure, refrigerant flow rate, and the air
temperature when the load was increased? Why?
Data Sheet
Date:
Suction Pressure (psig)
Head Pressure (psig)
Pressure After Exp. Valve (psig)
Refrig. Temp. Before Evaporator (F)
Refrig. Temp. After Evaporator (F)
Refrig. Temp. Before Condenser (F)
Refrig. Temp. After Condenser (F)
Refrigerant Flow Rate (PPM)
ERB,September 2001
31
31
ERB,September 2001
32
32
ERB,September 2001
33
33
Four-Stroke Transparent Gasoline Engine Analysis
Introduction
In this experiment you will observe the construction and operation of a four-stroke, single
cylinder, air-cooled, spark-ignition engine by using a Megatech -Mark III Transparent
Combustion Engine. Knowledge of its construction and operating characteristics will help to
provide an understanding of larger, multi-cylinder engines.
Apparatus
1. Megatech model DG-1 electric dynamometer
2. Megatech -Mark III model TE1 transparent combustion engine
3. Dayton heavy duty battery charger/booster
4. Air surge tank
5. Barometer
ERB,September 2001
34
34
Procedure
Set up the air surge tank shown in Fig. 1. (For a single cylinder engine a surge tank is installed
at the air intake of the engine to prevent serious fluctuations in velocity, temperature, and
pressure measurement. The volume of surge tank must be at least fifty times of the cylinder
volume.)
Follow instruction to start engine.
(A) To Start the Engine
1. Make sure the engine is connected to a suitable compressed air supply and a 12 volt DC 10
ampere (minimum) power source. For 1/2 hour or longer continuous Operation 15 psig of
cooling air is required Do not operate the engine without cooling air.
2. Fill fuel supply Pipette.
3. Open fuel line needle valve on engine 1-1/2 turns. Open throttle fully and turn the ignition
switch on.
ERB,September 2001
35
35
4. With field reversing switch at (4-) and high-low range switch on high, turn Load Adjust knob
to full clockwise 100% position for maximum starting torque.
5. Flip the Load Range switch to High position, otherwise the fuse will blow out.
6. Flip the Field Reverse switch to (+).
7. Now turn the switch to Start. When engine starts cranking, turn Load adjusts knob slightly
counter-clockwise to about 70% to increase the cranking speed.
8. Choke engine slightly by holding finger over carburetor intake tube for a second. If engine
fails to start, vary needle valve setting 1/4 turn and repeat
9. As soon as engine starts to run, flip the switch from Start position back to GEN., and set
Field Reverse switch to OFF position (center). Adjust needle valve for smoothest
operation. This will permit the engine to operate without load.
10. When engine is running smoothly and if you want to load the engine, set switch to Load
position, set the Field Reverse switch to (+) and vary Load Adjust setting until speed is
held at desired level. Readjust throttle and needle valve for best operation.
11. Take at least four load points. During this time do not adjust engine settings. Record needed
data for each:
a. RPM
b. Torque
ERB,September 2001
36
36
c. Fuel flow rate
d. Airflow rate
e. Cylinder Pressure
f.
Note: The engine is operating at a single mechanical throttle and mixture setting.
ERB,September 2001
37
37
(B) Shut Down the Engine
1. Turn off the load by setting the Field Reverse switch to OFF
2. Turn the cooling air off
3. Let engine run at half throttle for a minute
4. Shut the engine OFF
Caution: If you leave the cooling air on after engine shut-off, the rapid cooling air might crack the cylinder.
Result
After recording engine rpm. dynamometer torque, fuel rate, and calculate the following:
(1) The brake horsepower
The actual work output of an engine is usually determined by a power absorption device such as
the Pony brake, water brake, fan dynamometer, or an electric dynamometer, the electric
dynamometer being the most satisfactory for engine test purpose. In the dynamometer a torque
is measured by a force F and dynamometer arm r.
The work per minute is given by:
Work / Min. = 2 N T
Where: N = Engine speed in RPM, T =Torque in lb-ft
The brake horsepower (BH) is therefore obtained by dividing the work in lb-ft/min. by 33,000 lb-
ft/min.-Hp
BH= 2N T
33,000
(2) The specific fuel consumption
The specific fuel consumption is obtained by dividing the observed fuel rate by the observed
brake horsepower
BSFC = Observed fuel rate (lbs/hr) / BH
(3) The brake thermal efficiency The brake thermal efficiency = Brake work / Heat of fuel
Brake thermal efficiency (
b
) = Brake work (2 N T) (Btu/min )
heating value of fuel x fuel rate (Btu/min)
Some conversion of units may be necessary
heating value= 19750 Btu/lb.
??(Which is part of energy of fuel supplied that is converted into engine shaft work)
(4) The mean effective pressure
The mean effective pressure (mep) is an indication of engine performance, and is the amount of
work done per cycle in each cylinder divided by the displacement volume of the cylinder
mep = work per cycle / displacement (psi)
ERB,September 2001
38
38
where
Work per cycle = BH x 33,000 ft-lb x 2
Min. RPM
Displacement is the volume swept by the piston as it moves between bottom dead center and
top dead center in the cylinder. The displacement of the transparent engine is 4.148 in
3
(5) Plot performance curves example shown in Fig. 2 using a spreadsheet program like EXCEL
Torque, horsepower, efficiency.
speed/torque
0.0000
0.1000
0.2000
0.3000
0.4000
0.5000
0.6000
0 500 1000 1500 2000
RPM
T
o
r
q
u
e
(
F
t
-
L
b
)
Figure 2, Sample of one possible Performance Curve
ERB,September 2001
39
39
Double Pipe Heat Exchanger Experiment
Introduction:
One of the most important processes in engineering is the heat change between flowing fluids.
In heat exchangers the temperature of each fluid changes as it passes through the exchanger,
and hence the temperature of the dividing wall between the fluids also changes along the length
of the exchanger. Examples in practice in which flowing fluids exchange heat are air intercoolers
and preheaters, condensers and boilers in steam plant, condensers and evaporators in
refrigeration units, and many other industrial processes in which a liquid or gas is required to be
either cooled or heated.
Theory:
Consider the simple case of a fluid flowing trough a pipe and exchanging heat with a second
fluid flowing through an annulus surrounding the pipe. When the fluids flow in the same direction
along the pipes the system is known as parallel flow, and when the fluids flow in opposite
directions to each other the system is known as counter flow. Parallel flow is shown in Fig. 1a
and counter flow is shown in Fig. 1b.
Figure 1a Counter Flow Figure 1b Parallel Flow
It should be noted for counter flow that as the flow passage is lengthened, the temperature
difference between fluids A and B at any point in the flow passage becomes smaller and
smaller. Thus, with a very long flow passage, the temperature of fluid B at its exit approaches
that of fluid A at its entrance. Likewise the temperature of fluid A at its exit approaches that of
fluid B as it enters. As the Length of flow passage increases without limit, the temperature
difference between the two fluids in any point in the flow passage approaches zero and the heat
transfer process approaches a reversible one.
When heat is exchanged between two fluids flowing continuously through a heat exchanger, the
local temperature difference T, varies along the flow path. The heat transfer is calculated with
the familiar rate equation:
Q = UA ( T
m
) (1)
Where U is the overall coefficient of heat transfer from fluid to fluid, A is an area associated with
the coefficient U, and Tm is a mean temperature difference.
ERB,September 2001
40
40
For parallel flow or counter flow heat exchangers, this mean temperature difference is called the
log mean temperature difference (LMTD) and is defined as
T
m
= ( T
1
- T
2
)/ ln( T
1
/ T
2
)(2)
Where T1 and T2 are the differences in hot and cold fluids at the inlet and outlet,
respectively.
The overall heat transfer coefficient is given:
U = Q/A (T
m
) ..(3)
ERB,September 2001
41
41
Experiment:
Apparatus:
1. Double pipe heat exchanger system that includes:
a. Two concentric pipes
b. Thermocouples located along the pipe.
c. Flow meters
d. Flow control valves
e. Thermocouple selector switches.
2. Cold and hot water supplies
3. 2000 cc beaker
4. Stop watch
5. Plastic tubing
6. Flexible wire
7. Tape measure
Procedure:
1. Measure the Thermocouple locations (X)
2. Arrange heat exchanger for parallel flow with hot water in inner tube.
3. Turn on hot and cold water supplies to approximately same flow rate, max-range.
4. Measure volumetric flow rates for both hot water and cold water.
5. Read temperature at each thermocouple location.
6. Repeat steps 1-5 for two additional hot flow rates (3 runs total). Select flows rate, such
that the exit temperatures are significantly different.
7. Repeat steps 1-6, with heat exchanger arranged for counter flow. (3 data sets minimum)
Results:
NoteIf a thermocouple has an inconsistent reading, note that in your report and disregard the
data.
(A) Calculations:
1. Volumetric flow rate (V)
V = Volume/time
2. Cross-section area of inner tube (Ai)
ERB,September 2001
42
42
Ai = 3.1416(di)2 /4
di = 0.275 inches
3. Flow velocity (V)
V=V/Ai
4. Reynolds Number (N
R
)
N
R
=V di / or N
R
= V di/ v
5. Mass flow rate (m)
m =V
6. Heat transfer (Q)
Q=m c
p
(T)
Does Q
hot
= Q
cold
?
7. Log Mean Temperature Difference ( T
m
)
(a) Parallel flow
T
m
= [ (T
H
T
C
) out - (T
H
- T
c
)
in
] / ln[(T
H
- T
c
)
out
/(T
H
- T
c
)
in
]
(b) Counter flow
T
m
= [(T
H
,
out
T
c
,
in
) - (T
H,in
- T
c
,
out
] / ln[T
H
,
out
- T
c
- T
c
,
ou
t)/(TH,
in
T
C
,
out
)]
8. Heat transfer surface area (AT)
AT 3.1416 (di)(L)
di- average diameter of inner tube
L - total length of exchanger tubing
9. Over all heat transfer coefficient (U) (Btu / hr.ft
2
F)
U = Q
avg
/ A
T
(T
m
)
(B) Graphs:
1. Temperature of the hot and cold flows vs length X (consider the use of log scales). (10
graphs)
2. For Parallel flow Graph U vs Hot flow rate for a fixed cold flow rate.
3. For Counter flow Graph U vs Hot flow rate for a fixed cold flow rate.
Use a spreadsheet program like Excel to ease the graphing and calculation processes.
ERB,September 2001
43
43
SUGGESTED DATA SHEET
Parallel Flow
Flow Flow Flow Flow Flow Flow
Temp. Temp. Temp. Temp. Temp.
Temp.
C1 H1 C1 H1 C1 H1
C2 H2 C2 H2 C2 H2
C3 H3 C3 H3 C3 H3
C4 H4 C4 H4 C4 H4
C5 H5 C5 H5 C5 H5
C6 H6 C6 H6 C6 H6
C7 H7 C7 H7 C7 H7
C8 H8 C8 H8 C8 H8
C9 H9 C9 H9 C9 H9
C10 H10 C10 H10 C10 H10
Counter Flow
Flow Flow Flow Flow Flow Flow
Temp. Temp. Temp. Temp. Temp.
Temp.
C1 H10 C1 H10 C1 H10
C2 H9 C2 H9 C2 H9
C3 H8 C3 H8 C3 H8
C4 H7 C4 H7 C4 H7
C5 H6 C5 H6 C5 H6
C6 H5 C6 H5 C6 H5
C7 H4 C7 H4 C7 H4
C8 H3 C8 H3 C8 H3
C9 H2 C9 H2 C9 H2
C10 H1 C10 H1 C10 H1
ERB,September 2001
44
44
45
45
Heat Pump Experiment
The purpose of this experiment is to become familiar with the operation of a refrigerating system
in the heating mode.
The objectives are:
1. To determine the enthalpies at the principle points of the cycle.
2. To determine the heating effect of the system.
3. To determine the coefficient of performance of the system.
Introduction:
The use of the refrigerating system as a heating device or a heat pump was suggested by Lord
Kelvin in 1852. It is required that the system worked as an air conditioning during the summer
and operated as a heater during the winter season. When operated to remove heat from the
room, it is said to operate in the cooling mode; when operated to provide heat to the room, it is
said to operate in heating mode. In both the heating and cooling modes, additional energy has
to be provided to drive the compressor.
Heat pumps are available in many types, shapes, and sizes, of which those operating on the
vapor-compression cycle are the most commonly used.
During cooling mode, heat is absorbed from the room air into the evaporator and pumped to
outdoor via the condenser. This process is reversed for the heating mode. The condenser
(outdoor coil) picks up the heat, and the evaporator (indoor coil) releases the heat to the room
air. Hence, the two coils switch jobs during the heating process.
To avoid confusing, the component names, evaporator and condenser, are dropped when
referring to heat pumps. The two coils are referred to as the indoor coil and outdoor coil.
Heat pumps are sometimes called reversed refrigerating cycle. The term reverse is not
technically correct since the cycle is not reversed. Only the evaporator (indoor coil) and
condenser (outdoor coil) are interchanged. This is usually accomplished by a reversing valve.
46
46
A typical vapor-compression heat pump is shown in Fig. 1.
Apparatus:
1. Model 9001 Brodhead-Garrett Basic Refrigeration Unit
2. Power measuring device (Watt meter)
Procedure:
1. Close HP1 and HP4, open FMB, HP2 and HP3.
2. Open CIV, close AXV and TXV, open LR1, LRK, and
close LRB.
3. Turn power switch on, evaporator and condenser fan on
high, and start compressor.
47
47
Which Heat Exchanger is the Evaporator? Condenser?
4. Let system operate for 5 minutes or more until stabilized.
5. Record: Pressure and temperature at the principal points of the cycle, power consumed
by the compressor, and refrigerant flow rate.
6. Repeat steps with different fan speeds:
Condenser high, Evaporator low
Condenser low, Evaporator low
Condenser low, Evaporator high
Shut Down
Close LRB, and open LRV and operate until the suction pressure drops to 5 lbs.
Turn the compressor off.
48
48
Unit Sketch with Flow Path and Direction
Results:
1. Determine enthalpies at the principle state points.
Points referred to Fig. 1 in Vapor-Compression (Refrigeration Cycle) Experiment.
2. Determine the heating effect of the heat pump.
Heating Effect = m refrigerant ( h) indoor coil
3. Calculate COP of the heat pump.
(COP)heat pump = (Heating Effect) I (Work of compressor)
49
49
50
50
4. Analysis:
Show the reversed vapor compression cycle state points on the refrigerant diagram. Figure
2. Show these state points also on the unit sketch
For each of the four fan speed combinations find:
1) Enthalpy at principle points
h
1
= Btu/lbm
h
2
= Btu/lbm
h
3
= Btu/lbm
h
4
= Btu/lbm
2) Mass flow rate of refrigerant
Mass flow rate of refrigerant can be determined from the heat balance across
compressor
M
f
(h
2
- h
1
) = Compressor power
Compressor power = Power consumption by compressor x compressor efficiency
(1 kw = 3412.14 Btu/hr.)
3) Heating effect of heat pump
Q = M
f
(h
2
- h
3
)
4) COP of heat pump
(COP)
heat pump
= Heating effect I Work of compressor
[Work of compressor = M
f
(h
2
- h
1
)]
51
51
Polytropic Process - Air Compressor Experiment
Introduction:
The position of the piston, as it travels up and down in the cylinder of the air compressor, is
measured by a linear variable differential transformer (LVDT). The LVDT is attached to an
external crank shaft which rotates at the same speed as the compressor. The external crank is
coupled to an auxillasry cylinder, so that the LVDT output is maximum when the piston is at
bottom dead center and minimum when the piston is at top dead center. Thus, maximum output
corresponds to maximum displacement and minimum output corresponds to minimum
displacement. The output from the LVDT signal conditioner is measured by a digital storage
oscilloscope.
Pressure Transducer
Pressure in the cylinder of the air compressor is measured by a piezoelectric pressure
transducer. The pressure transducer consists of a quartz block and electrodes that are attached
to a diaphragm. Compressing the diaphragm causes an electric charge at the electrodes that is
proportional to the force that has been exerted on the quartz block. The charge is converted to
an analog voltage by the signal conditioner. Thus, electrical output of the signal conditioner is
proportional to pressure. Pressure will be measured by a digital storage oscilloscope which is
connected to the signal conditioner.
The scope can display position vs time and pressure vs time. More interesting is to use the
scope to factor time out and plot pressure vs position. Knowing that position is proportional to
volume, this becomes a PV diagram.
52
52
LVDT
Auxiliary
Cylinder
Crank
Shaft
Apparatus
1. Sears model 106-17012 piston-type air compressor
2. Digital storage oscilloscope
3. X-Y recorder with pen and chart paper
4. Trans-Tek 0216-0000) LVDT
5. Trans-Tek 1000-0012 LVDT signal conditioner
6. PCB H111A26 pressure transducer
7. PCB 482A signal conditioner for pressure transducer
8. Acopian 24GT50D/24GT50D power supply
9. Wattmeter
10. Stroboscope
53
53
Procedure
1. Operating the Air Compressor
Adjust the wattmeter range to 1000 Watts and voltage to 125 Volts.
Open the receiver discharge valve; the receiver may be pressurized, so stand to one side
of the valve and do not place hands in front of the air discharge.
Pressure in the receiver should be limited to 70 psig
The air compressor should be plugged into the wattmeter. Plug the wattmeter into an ac
receptacle to start the air compressor.
2. Using the digital Storage Oscilloscope (DSO)
Properly adjust controls on the DSO
With the air compressor running and the LVDT signal conditioner energized, adjust
Channel A Range and Multiplier until a sine wave is displayed with peak-to-peak
amplitude that occupies 20% to 50% of the screen. Rotate the DC Level control until the
waveform is centered on the screen.
Adjust Time Per Point until at least one complete wave, but not more than three complete
waves appear.
Turn Mode switch to NORM. Slowly rotate Threshold control until Trig light begins to
glow. Adjust Threshold control so that the sine wave appearing on the screen begins half
way between the maximum amplitude and the minimum amplitude.
Switch Channel A OFF.
Switch Channel BUN
Adjust Channel B Range and Multiplier until the peak-to-peak amplitude of the pressure
waveform occupies 20% to 50% of the screen. Rotate the DC Level control until the
waveform is centered on the screen.
Switch Channel A ON. The displacement and the pressure waveforms should be
displayed. When the piston reaches top dead center and begins to travel downward, air
will be drawn into the cylinder and pressure will be approximately atmospheric. As the
piston moves up from bottom dead center, the pressure should increase polytropically.
The discharge valve opens as displacement continues to decrease, so there will be a
sudden decrease in pressure before the piston again reaches top dead center.
Move Wave display toggle switch to X / Y. A P-V diagram should be displayed. Rotate
the Y-Expansion knob, if necessary, to increase the height of the P-V diagram. If
pressure vs. time was exactly the same for each power stroke of the compressor, the P-V
diagram would appear as a stationary closed loop on the screen. However, because
pressure vs. time differs slightly with each cycle, the display may appear as a different [
for each cycle.
Insert a disk into DISK MEMORY. Read/Write (label) side should be toward the right.
Press SELECT switch until the LED is illuminated next to track 1 or other specified track
for recording data Move PROTECT switch to selected track to OFF.
54
54
Press HOLD LAST to capture the p-v diagram. Observe the rotational speed with a
stroboscope and record the rotational speed. Also, record the wails input to the air
compressor motor. If the p-v diagram closed on itself, indicating repeatable cycle, press
STORE to record the data. If the diagram does not close on itself, press Storage Control
to UVE, and when the diagram appears to be closing, press HOLD LAST once again.
Repeat these steps, if necessary, until a satisfactory p-v diagram has been recorded.
Indicated work will be determined from the p-v diagram. Indicated horsepower can then
be calculated using the value of indicated work and the rotational speed of the
compressor shaft. Input power is displayed by the wattmeter.
Increase pressure in the receiver to 5 psig by partially closing the receiver discharge
valve. Allow the pressure in the receiver to stabilize. Then, record the new p-v diagram
and corresponding input power, following the procedure outlined above. Data should be
obtained at additional receiver pressures so that everyone has a different set of data to
analyze.
3. Determination of the Indicated Horsepower
The p-v diagrams that have been recorded with the DSO can be plotted on an x-y
recorder. The plots should be made on graph paper.
To output the data from the DSO, first set the control as follows:
Storage Control HOLD LAST
Function PEN
Wave Display X / Y
Then, use the Track and Recall switches to display the desired set of stored data. The p-
v diagram that is displayed can be expanded for clarity using the Vertical and Horizontal
Expansion switches. It is usually possible to expand the diagram so that it occupies more
than half of the screen. To transfer data to the x-y recorder, begin with the recorder pen
in the lift or up position, and press Execute. The DSO will then automatically trace the p-v
diagram, converting the points that make up the diagram to analog values, and passing
these values on to the x-y recorder. In order to obtain a reasonably large plot of the
diagram on the x-y recorder, it may be necessary to adjust the x and y gain controls on
the recorder and to repeat the data transfer by pressing Execute again. When the size of
the p-v diagram appears to be large enough, lower the recorder pen, press Execute, and
plot the diagram.
The length of the diagram along the x-axis represents a displacement of 9.0 cubic inches.
The length of the diagram along the y-axis represents absolute pressure; the value of
absolute pressure can be calculated as follows: Position the Wave Display switch to X /
T. Then, use the cursor paddle switches to move the cursor to the top of the pressure
waveform. Record the millivolts reading that appears on the screen. Use the cursor
paddle switches to move the cursor to the bottom of the pressure waveform. Again,
record the millivolts reading that appears on the screen. Calculate the difference between
the millivolts readings. Multiplying the difference in millivolts readings by the transducer
sensitivity results in gauge pressure, i.e.,
Gauge Pressure = millivolts difference x (0.0335 psi) / millivolts
55
55
Next, obtain the barometric pressure. Convert pressure from inches of mercury to psi
using the relation:
1.GXJ inch of mercury = 0.491 psi
The largest value of absolute pressure on the p-v diagram is the sum of the barometric
pressure (psi) and the gauge pressure. The smallest pressure on the p-v diagram is the
barometric pressure (psia).
The p-v diagram can now be scaled. Measure the distance (in centimeters or inches,
depending on the x-y recorder and scale of the graph paper that has been selected) from
the maximum value of displacement to the minimum value of displacement. The scale
factor for the x-axis will be
X-axis scale factor = (9.00) in3) / (Length of diagram along X-axis)
Measure the distance from the maximum value of pressure to the minimum value of
pressure. The scale factor for the Y-axis will be
Y-axis scale factor = (Gauge pressure) / (length of diagram along Y-axis)
The indicated work is indicated by the area of the p-v diagram. The area can be
estimated by counting the squares on the graph paper that are contained inside the p-v
diagram. It is also possible to determine area using a planimeter. To calculate indicated
work,
Indicated work = Area x X-axis scale factor x Y-a scale factor
Note that units of work are inch pounds. Convert units of work to fool pounds.
The amount of work indicated by the p-v diagram is performed by the compressor each
time the crankshaft completes one revolution. Power is the rate at which work is
produced. Therefore, the indicated horsepower can be calculated,
Indicated HP = RPM x Indicated Work x HP / 33,000 ft-lb / min.
4. Input Horsepower
The input horsepower to the electric motor was measured by the wattmeter, and must be
converted from watts to horsepower using the relation,
1HP = 746 watts
5. Overall Efficiency
The overall efficiency is the air compressor can be estimated,
Overall efficiency = (Indicated horsepower) / (Actual horsepower) x 100%
56
56
Turbine Technologies Ltd.
Steam Turbine Experiment
An Educational, Micro-Electric Power-Generating Station
I. Objective
The objective of this laboratory is to offer students hands-on experience with the operation of a
functional steam turbine power plant. A comparison of real world operating characteristics to
that of the ideal Rankine power cycle will be made.
The apparatus is scaled for educational use and utilizes components and systems similar to full-
scale industrial facilities. Students will be able to operate and analyze this system in detail,
allowing them to determine the efficiency of the facility and suggest possible modifications for
further improvement. The turnkey laboratory system carries the trade name of RankineCycler
II. Theory
57
57
The Rankine cycle is the most common of all power generation cyles and is
diagrammatically depicted via Figures 1 and 2. The Rankine cycle was devised ot make use
to the characteristics of water as the working fluid. The cycle begins in a boiler (State 2 in
figure 1), where the water is heated until it reaches saturation-in a constant-pressure
process.
Once saturation is reached, further heat transfer takes place at a constant temperature, until the
working fluid reaches a quality of 100% (State 3). At this point, the high-quality vapor is
expanded isentropically through an axially bladed turbine stage to produce shaft work. The
steam then exits the turbine at State 4. The working fluid, at State 4, is at a low-pressure, but
has a fairly high quality, so it is routed through a condenser, where the seam is condensed into
liquid (State 1).
Finally, the cycle is completed via the return of the liquid to the boiler, which is normally
accomplished by a mechanical pump* (See notation under Figure 3).
Figure 1 below shows a P-v diagram for a simple ideal Rankine cycle (refer to your
thermodynamics text for additional details)
58
58
2 1 3 4
Installed sensor list includes:
1. Boiler pressure 2,3
2. Boiler temperature 3
3. Turbine inlet pressure 3
4. Turbine inlet temperature 3
5. Turbine exit pressure 4
6. Turbine exit temperature 4
7. Fuel flow FF
8. Generator voltage output V
9. Generator amperage output A
59
59
FF 2 3 4
Calculate:
h
1,2,3,4 ,
Using T
1,2,3,4
and P
1,2,3,4
respectively
Qin
Wout of generator
Efficiency
Graph:
the cycle on a Mollier diagram to the extent possible.
III. Experimental Apparatus
60
60
The experimental hardware (RankineCycler
TM
) consists of multiple components that make up
the necessary components for electrical power generation (utilizing water as the working
fluid). These components include:
Boiler
A stainless steel constructed, dual pass, flame-through tube type boiler, with super head
dome, that includes front and rear doors. Both doors are insulated and open easily to reveal
the gas fired burner, flame tubes, hot surface igniter and general boiler construction. The
boiler walls are insulated to minimize heat loss. A side mounted sight glass indicates water
level.
Combustion Burner / Blower
The custom manufactured burner is designed to operate on either LP or natural gas. A solid-
state controller automatically regulates boiler pressure via the initiation and termination of
burner operation. This U.L approved system controls electronic ignition, gas flow control and
flame sensing.
Turbine
The axial flow steam turbine is mounted on a precision-machined stainless steel shaft, which
is supported by custom manufactured bronze bearings. Two boiler ports supply lubrication to
the bearings. The turbine includes a taper lock for precise mounting and is driven by steam
that is directed by and axial flow, bladed nozzle ring. The turbine output shaft is coupled to
an AC/DC generator.
Electric Generator
An electric generator, driven by the axial flow steam turbine, is of the brushless type. It is a
custom wound, 4-pole type and exhibits a safe/low voltage and amperage output. Both AC
and DC output poles are readily available for analysis (rpm output, waveform study,
relationship between amperage, voltage and power). A variable resistor load is operator
adjustable and allows for power output adjustments.
Condenser Tower
The seamless, metal-spun condenser tower features 4 stainless steel baffles and facilitates
the collection of water vapor. The condensed steam (water) is collected in the bottom of the
tower and can be easily drained for measurement/flow rate calculations.
The experimental apparatus is also equipped with an integral computer data acquisition station,
which utilizes National Instruments
TM
data acquisition software
The fully integrated data acquisition system includes 9 sensors. The sensor outputs are
conditioned and displayed in real time- on screen. Data can be stored and replayed. Run data
can be copied off to floppy for follow-on, individual student analysis. Data can be viewed in
Notepad, Excel, and MSWord (all included).
61
61
The system is test run at the factory prior to delivery and the factory test run is stored on the
hard drive under the My documents folder. This file should be reviewed prior to operation as it
gives the participant an overview of typical operating parameters and acquisition capability.
SENSORS
Nine (9) sensors are installed at key system locations. Each sensor output lead is routed to a
centrally located terminal board. A shielded 64-pin cable routes all data to the installed data
acquisition card. This card is responsible for signal conditioning and analog to digital conversion.
Software and sensor calibration is accomplished at the factory prior to shipment.
Installed sensor list includes:
1. Boiler pressure
2. Boiler temperature
3. Turbine inlet pressure
4. Turbine inlet temperature
5. Turbine exit pressure
6. Turbine exit temperature
7. Fuel flow
8. Generator voltage output
9. Generator amperage output
OVER ALL SYSTEM DIMENSIONS
Length: 48.0 inches (122cm)
Width: 30.0 inches (77 cm
Height: 58.0 inches (148 cm)
62
62
*Note: When compared to figure 2 (simple ideal Rankine cycle), the steam ejected from
the RankineCyclerTM turbine condenses into liquid via the condenser tower and then exits
the condenser into a collecting volume at the condensers base, rather than being pumped
back to the boiler. The condensate can subsequently be weighed. This allows for
measurement of the mass flow rate of the working fluid, by means of collection. This
represents the main difference between the simple Rankine cylcle described in figure 2,
since the liquid exiting the condensers is dispensed, rather than pumped back to the boiler.
The RankineCycler
TM
apparatus schematic depicted on the previous page allows students to
monitor the power plant system and obtain data from the 9 installed sensors (depicted in green,
Figure 3).
63
63
Thermocouples and pressure transducers located at various locations in the steam loop allow
for monitoring of pressures and temperatures, which can be used to determine the state of the
working fluid at appropriate locations.
IV. General Safety
The RankineCycler
TM
apparatus exhibits hot surfaces during operation. Equipment
familiarization is particularly important in order to prevent injury. Under no circumstance should
anyone attempt to open boiler doors during operation, or at anytime that the boiler exhibits a
positive pressure reading. The boiler has been low cycle fatigue pressure tested. Ultimate
operating pressures that exceed normal operating pressures by 50% have been tested. NEVER
ATTEMPT TO EXCEED MAXIMUM OPERATING PRESSURE. DO NOT ATTEMPT TO MAKE
ANY ADJUSTMENTS TO SAFETY DEVICES AND OR CONTROLS TO ATTEMPT
OPERATIONS OUTSIDE OF ESTABLISHED LIMITS. The boiler is not ASME rated, nor is it
approved by any other test facility. IMPROPER USE MAY CAUSE DEATH OR SERIOUS
INJURY. Should any questions arise regarding the safe operation of this equipment, please
speak to your laboratory supervisor.
Personal protection
This plan is a sample plan of precautionary measures that should be considered to prevent
injury during the use of the RankineCycler
TM
and may or may not be more stringent than your
current lab safety plan. It should be used as a guide only. Safety measures must be taken
during all use of laboratory equipment. Consult your lab safety specialist for a detailed, site-
specific plan.
Suggested Protection Devices:
Gloves
Eye Protection
Splash Protection
Fire Extinguisher
Posted Emergency Exit
Posted Emergency Numbers
Before developing your own personal protection plan, you first need to read and review the
RankineCycler
TM
owners manual, as well as your facilitys general lab safety plan and
procedures.
Combustion is taking place and results in hot surfaces. Do not touch any surface unless familiar
with the system.
Before use, the boiler should be checked to verify component integrity. DO NOT USE the
RankineCycler
TM
unless given explicit permission to do so.
During use, the following should be worn at all times: gloves, safety goggles and a splash apron.
Jeans and a long sleeved shirt are much better than shorts and a t-shirt. The heavier clothing
will provide some protection in the event hot surface or vapor contact.
Familiarize yourself with the location of the nearest fire extinguisher. If the RankineCycler
TM
is
running and you notice the smell of natural gas or LP (dependent upon fuel type used), quickly
turn off the gas and exit the room. Notify your supervisor that a potential gas leak exists.
64
64
Assure that emergency contact numbers are posted and that you are aware of the nearest exit
and phone locations. Also, be sure you know where the laboratory first aid kit is located and that
it is properly stocked.
V. RankineCyclerTM Operation
Do not begin any operation without proper supervision. The operation of the equipiment will be
done only by a trained lab technician or faculty member..
RankineCycler entails the following operator controls:
GAS VALVE
The gas valve is a simple two-position valve (On or Off). It is located on the far right side of the
slanted operator control panel. It will prevent gas flow to the burner when in the off position-
regardless of any other control positions/settings.
KEYED MASTER SWITCH
The systems electronic master switch is key operated and is located on the left side of the
operator control panel. This key switch supplies power to all electronic and electrically operated
components. A green indicator light located directly above the keyed master switch, will light
when the master switch is selected to the on position and power is available to the switch.
BURNER SWITCH
The burner switch is labeled as such and is located next to the keyed master switch. The burner
switch powers the automatic gas valve and ignition controls. A green indicator light, located
directly above the burner switch, will light when the burner switch is selected to the on position
and power is available to the switch.
LOAD SWITCH
The load switch functions as a generator load d switch
LOAD RHEOSTAT CONTROL KNOB
The load rheostat control knob is connected in series with the load toggle switch and generator
DC output terminals. It provides a source of variable generator load
AMP METER
The amp meter indicates generator load conditions.
VOLTMETER
The voltmeter indicates the generator voltage output.
STEAM ADMISSION VALVE
The steam admission valve controls the steam flow rate to the steam turbine
Sensors
Pressure, Temperature and Flow Sensors facilitate collection, storage and retrieval of real time
data.
GAS FLOW
65
65
The gas flow sensor is a turbine-based flow-metering unit. It is installed inside of the operator
panel and interfaced with the computer data collection station. Gas flow rates are depicted on
the PCs monitor via a graphical and numerical presentation.
BOILER PRESSURE AND TEMPERATURE
Boiler pressure and temperature data is collected via transducer and thermocouple sensors,
respectively. The sensor output is calibrated to read in engineering units via the PC data
acquisition presentation.
STEAM TURBINE INLET & OUTLET PRESSURE & TEMPERATURE
Inlet and outlet pressure and temperature sensors for the steam turbine are installed in the
steam turbines front and rear housings. Pressure transducers are located within the front
operator panel enclosure. Temperature sensing thermocouples are plug connected and routed
to the data acquisition terminal board. The terminal board features on board cold junction
compensation.
OPERATIONAL CHECKLISTS
PRE-START
1. Determine suitability of operational location (i.e. adequate ventilation, access to 110V
power)
2. Lock caster wheels
3. Perform visual inspection to check for general system condition (sight glass, piping, boiler,
overall system integrity).
4. Assure front and rear boiler doors are latched
5. Open steam admission valve. Do not attempt to fill boiler while hot or under pressure.
6. Insert supplied fill/drain fitting (hose attached) into filler port located at the rear of the boiler
(opposite side of instrument panel). Attach a funnel to end of hose arid hold funnel above boiler
height.
7. Fill boiler with clean tap water (if the boiler doesnt appear to be accepting water, pull filler
fitting out slightly until water starts to flow into boiler. If fitting is pulled out too far, water will spill
onto the base cabinet).
The actual boiler diameter is equal to the door diameter. Do not fill the boiler to a higher level
than to 3/4ths the height of the door height.
8. Remove filler hose.
9. Close the steam admission valve
10. Turn load switch to off position
11. Turn burner switch to off position
12. Turn load rheostat knob fully counter clockwise (minimum load).
13. Insert multi pin computer plug into terminal board on left side of RankineCycler cabinet.
14. Plug computer power cord into 115 VAC outlet
15. Plug RankineCycler power cord into 115 VAC outlet
16. Connect gas pressure regulator to LP gas tank
66
66
17 Connect low pressure gas hose from regulator exit to barbed RankineCylcler gas inlet fitting
(located on the right side of the operator control panel) Assure leak free connection Allow any
remaining condensate to drain from the tower by locating attached condenser drain hose and
squeezing hose fitting to un-pinch the drain hose. Hold hose below condensate tower and
drain tower water into any available container.
18. Remove knurled screw caps from steam turbine front and rear oilers.
19. Fill oilers to within 1/8th inch from the top of the oiler with turbine oil that meets Mil-L-
23699C specifications.
NOTE: OIL MUST BE ADDED TO THE OILERS AFTER EACH RUN. DO NOT ATTEMPT TO
START WITHOUT CHECKING OIL LEVEL. TURBINE BEARING WILL OCCUR WITHOUT
PROPER LUBRICATION.
START
1. Open LP bottle gas valve
2. Turn gas valve knob CCW to on position
3. Turn master switch on (observe green indicator Light on)
4. Turn burner switch on (observe green indicator light on)
NOTE: Combustion blower starts automatically. Wait for 30 seconds. This will allow the lines to
purge. Then turn the burner switch to the off position and immediately back on (this step can
be eliminated from the start procedure if the system has previously been operated using the
currently attached LP source). This resets the starting cycle and assures that the lines are
purged. After approximately 20 seconds, the automatic gas valve will open and the burner will
light.
5. Boiler pressure indication should be observed within 3 minutes of ignition.
NOTE: SHUT OFF BURNER SWITCH IF THE BOILER PRESSURE EXCEEDES 130 PSIG.
Automatic regulation should assure shutoff at approximately 120 psig. In the event of over
pressure (exceeding 125 psig) contact Turbine Technologies Ltd.
6. Power up data acquisition station and open Virtual Bench on desktop
7. Observe voltmeter and open steam admission valve. Regulate turbine speed to indicate 7-10
volts. This will pre-beat turbine components and pipes. Close valve after 20 seconds and wait
for boiler pressure to rise. Very small leaks may be visible due to condensation and cold turbine
bearing clearances. This is normal and will stop after normal operating temperatures are
attained.
8. Open steam admission valve to read close to maximum voltage.
9. Turn load switch to onposition.
10. Adjust load rheostat knob and steam admission valve to obtain a steady state power output.
9 volts and 0.4 amps are good values for steady state operation.
11. Mark time and set upper sight glass bezel to current water level. Fine adjust steam
admission valve for steady state operation
SHUT DOWN
1. Close steam admission valve when sight glass water level reaches the pr-selected lower
bezel setting
67
67
2. Move burner switch to off position
3. Turn gas valve off
4 Turn LP gas bottle valve off
5. Hold heat resistant measuring beaker under condenser tower drain. Drain condensate by
squeezing hose pinch. Measure condensate. CAUTION: Water may be hot
6. Wait until boiler cools and pressure is below 10 PSIG. Then open steam admission valve.
When boiler pressure equals atmospheric, fill a measuring beaker with clean tap water and re-fill
boiler via the boilers drain/fill port- to the exact sight glass upper bezel level. The measured or
weighted re-fill mass represents the boilers total steam production and can be correlated as
steam rate by dividing the water weight by the duration of the run (found be Looking at the start
and stop time of the run as measured by the data acquisition station.
EMERGENCY SHUTDOWN
1. Unplug RankineCycler power cord
2. Move to a safe distance
3. If safety is not compromised: Turn burner switch off, turn road rheostat to maximum, open
steam admission valve to obtain maximum voltage.
OPERATIONAL DOS AND DONTS
DOS
Read, remember and follow operators manual
Watch gage readings at all times
Check oil levels on turbine oilers often
Remember the working fluid is pressurized, hot steam
Develop your own protection plan
See through operator shielding, personal protective gear! etc.
Look caster wheels
Provide good ventilation
DONTS
Do not tap sight glass, scratch or mark
Do not tighten or adjust fittings while boiler is under pressure
Do not touch parts that are not labeled (hot components)
Do not operate boiler with water level below 4 inches or above 6.5 inches
Do not move unit with the boiler under pressure
Do not attempt to open fill/drain valve when boiler is hot
Do not exceed scale readings on volt or amp meter
Do not allow anyone to operate the unit that is not familiar with the Operating v1anual and the systems
practical usage
Do not operate unattended
68
68
VI. Data Acquisition, General Discussion
The RankineCycler
TM
comes equipped with a turnkey data acquisition system. The PC hardware
is located on a wheeled cart as depicted on the front cover of this manual. A 64-pin interface
cable is routed from this station to the RankineCycler
TM
terminal board. Nine (9) data points
(pressures, temperatures, fuel flow, voltage and amperage) are collected via installed sensors.
The Sensor Parameter Chart (Table A) indicates the function, manufacturer/type, range and
output value of the installed sensors. Table B depicts the physical location of the sensor on
leads on the terminal board.
69
69
70
70
71
71
VI. Possible Experimental Procedures
The following laboratory procedures should be used as a guide for possible student activities.
Sample labs:
The lab technician will start the facility and assist students in changing conditions. The students
primary function is to gather data at the appropriate time for each run condition. This is
accomplished via the system installed software.
The condensate collection reservoir, when drained, will yield the mass flow rate (when
divided by the testing interval time.
EES Power Cycle Design for Best Efficiency
Objective
The purpose of this lab is to gain insight on vapor power systems and the effectiveness of their
operation. For this experiment the overall efficiency of vapor power systems will be studied. With
the use of Engineering Equations Solver a power cycle will be designed. The objective is to
create a power system and alter it in different ways to achieve the greatest efficiency.
Background
Vapor power systems are a type of cycle that converts energy to a useful state. The main goal
of these systems is to produce a power output from a fossil fuel, nuclear, or solar energy input.
In those cycles a working fluid is vaporized and then condensed. This is done using many
components: however the general main components include the following:
-Heater (boiler)
-Turbine
-Condenser
-Pump
Each of these components performs a key role in creating an output from the energy input. The
heater, most often a boiler, uses the energy input from burning fossil fuels, nuclear, or solar
energy to heat and evaporate the working fluid. The working fluid, now a vapor, then passes
through the turbine creating a work output. The condenser transfers heat from the vapor working
fluid to make it sub cooled liquid. The pump uses a work input to move the liquid back through
the cycle.
Equations to be used
3 2
h h
m
W
t
=
Thermal efficiency of this system is defined by the following;
72
72
( ) ( )
4 1
3 4 2 1
h h
h h h h
m
Q
m
W
m
W
in
p
t
Procedure (a computer with EES software is required)
1. With EES define (within reasonable limits) the temperature and pressure at each of the stages
in the cycle.
T
1
=
P
l
=
2. Next define that the b for each stage is the enthalpy for the working fluid at T and P
3. Use a variable, such as _, which will be the efficiency of the cycle and enter the equation that
defines thermal efficiency of the cycle,
4. Solve the equation in EES to find the efficiency of the cycle with the given stage temperatures
and pressures.
5. Change the temperatures and pressures ant each state to get a better efficiency.
6. Repeat the procedure until an acceptable efficiency is achieved.
7. If necessary, such things as reheat or second turbine stages may be modeled in the system.
Analysis of results
1. Calculate:
a. h
1,2,3,4 ,
Using T
1,2,3,4
and P
1,2,3,4
respectively
b. Qin
c. Wout of generator
d. Efficiency
2. Graph:
a. This cycle on a Mollier diagram to the extent possible.
3. Explain differences from ideal Rankine cycle.
73
73
Appendix
The following section is a general description of the Rankine Cycle as it relates to
Thermodynamics, Heat Transfer, and Fluid Mechanics.
Theoretical Background of Thermodynamics
One of the most important ways to convert energy from such things as fossil fuels, nuclear, and
solar potential energy is through processes known as vapor power cycles. One example of the
use of vapor power cycles is electrical power plants. As engineers it is important to become
familiar with these types of systems. The first step in becoming familiar with these cycles is
through studying the theoretical ideal of the processes.
The ideal cycle for vapor power cycles can be modeled using the Rankine Cycle. This cycle is
composed of four components: heater (boiler), turbine, condenser, and pump. To complete the
system there must be some type of fluid in the cycle, which is called working fluid. Most often
the working fluid is water. As the working fluid passes through each of the components it
undergoes a process and ends up at a new state. Keeping in mind that the ideal Rankine cycle
is physically impossible, we define each process to involve no internal irreversibilitys. For the
following it is necessary to number each of the states. State 1 is the state that at the boiler exit.
State 2 is the turbine exit. State 3 is the condenser exit and state 4 is the pump exit.
Now the processes that the working fluid undergoes as it completes the cycle will be defined.
First is the heater, which in most cases is a boiler. As the fluid ends the cycle, at state four, it is
pumped into the boiler. In the boiler, the working fluid is heated from sub-cooled liquid to
saturated vapor. This occurs at a constant pressure and is described in the following equation:
4 1
h h
m
Q
in
=
Equation 1
Where
m
Q
in
, is the rate of heat addition per unit mass of working fluid passing through the boiler.
The value (h
1
h
4
) is the difference in outlet and inlet enthalpies of the working fluid.
Second is the turbine. Through the turbine the vapor leaving the boiler expands to the
condenser pressure. This is said to be isentropic expansion so that no heat transfer to the
surroundings is present. The equation that is used to describe this process is as follows
2 1
h h
m
W
turbine
=
Equation 2
m
W
turbine
is the rate at which work is developed per unit of mass passing through the turbine.
Again the difference in inlet and exit enthalpies of the working fluid is required. Next the working
fluid enters the condenser. At this stage beat is rejected from the vapor at a constant pressure.
Ideally, this continues until all of the vapor condenses to leave nothing but saturated liquid. The
equation for this is seen here:
74
74
3 2
h h
m
Q
out
=
Equation 3
m
Q
out
is the rate at which heat is transferred from the working fluid per unit of mass. The
value (h2 h3) is the difference inlet and outlet enthalpies of the condenser.
Finally, the working fluid enters the pump. The fluid goes through an isentropic
compression process to reach the boiler pressure. The equation describing this is as follows:
3 4
h h
m
W
pump
=
Equation 4
m
W
pump
rate of power input per unit of mass passing through the pump. Finally the difference
in pump outlet enthalpy and inlet enthalpy is needed.
Theoretical Background of Heat Transfer
A heat exchanger is a device that facilitates the transfer of energy between two fluids at
different temperatures while keeping them from moving. Heat exchangers allow two types of
heat transfer to occur. Convection is the mode of energy transfer between a solid surface
and the adjacent liquid or gas that is in motion. Conduction is the interaction of particles,
which transfers energy from more energetic particles to the less energetic ones. The rate of
energy transfer between two fluids depends on the temperature difference between the two
fluids, which varies along the length of the heat exchanger.
A heat exchanger in which one fluid condenses as it flows and gives off heat is called a
condenser. A heat exchanger that involves one fluid absorbing heat and vaporizing is known
as a boiler.
Newtons law of cooling allows the rate of heat transfer to be expressed as:
lm
T A U Q = * *
Equation 5
A is the heat transfer area. U is the overall heat transfer coefficient. This can be determined
from the equation.
o i
h h U
1 1 1
+ Equation 6
_ T
lm
is the logarithmic mean temperature difference:
|
|
.
|
\
|
=
2
1
2 1
ln
T
T
T T
T
lm
Equation 7
75
75
Theoretical Background of Fluid Mechanics
Fluid mechanics is concerned with the behavior of liquids and gases at rest and in motion. The
RankineCyclerTM applies two main topics of fluid mechanics: viscous pipe flow and turbo-
machinery.
Viscous pipe flow will either be completely filled or it will be partially filled open channel. It
should be assumed that the steam moving through the pipe is completely filling the pipe.
Determining how the flow is moving through the pipe is also important. Laminar, transitional, and
turbulent flow could show up each of these cases has a different governing set of equations
Q = V*A Equation 8
If the cross-sectional area, A, and the velocity, V, is known the volumetric flow rate, Q, can be
found. It is also essential to find the Reynolds Number
VD
= Re Equation 9
Where: r, is the density of the working fluid, V, is the average velocity in the pipe, D, is the pipe
diameter, and m, is the dynamic viscosity of the fluid. The Reynolds Number will help determine
the type of flow. If the Reynolds Number in a round pipe is less than ~ 2100 the flow is laminar.
If the Reynolds Number is greater than 4000 in a round pipe is determined to be turbulent. The
transition region is between Reynolds Numbers of 2100 and 4000, respectively.
When a fluid enters a pipe with a near uniform velocity profile viscous effects cause the fluid to
stick to the pipe wall. A boundary will form so the velocity profile changes with distance from the
entrance region till the end of the entrance region, the boundary layer has completely filled the
pipe. The entrance length is defined for laminar and turbulent flows as:
flows laminar for Re 06 . 0 =
D
l
e
Equation 10
flow turbulent For (Re) 4 . 4
6
1
=
D
l
e
Equation 11
After the entrance region fully developed flow might be obtained depending upon the length of
the pipe.
The pressure difference across a section of pipe:
p = p
1
p
2
Equation 12
76
76
This is the force that moves the fluid through the pipe
Fully developed laminar horizontal pipe flow can be described as the difference in pressure
acting on the end of the pipe and the shear stress acting on the walls of the pipe. Thus:
( ) 0 2 *
2
1
2
1
= rl r p p r p
simplifies to:
r l
p 2
=
Equation 13
Where r = 0 there is no shear stress acting on the fluid. Although when r = D/2 the shear
stress is at a maximum, where t
w
, the wall shear stress, so:
D
r
w
2
= Equation 14
The pressure drop if the viscosity was zero would be:
D
l
p
w
4
= Equation 15
So a small shear stress can have a large pressure difference if the pipe is long (l/D >>1).
The shear stress of a Newtonian fluid is proportional to the velocity gradient, so:
dr
du
= Equation 16
The velocity profile can be written as:
( )
(
(
|
.
|
\
|
=
(
(
|
.
|
\
|
=
2 2
2
2
1
2
1
16 D
r
V
D
r
l
pD
r u
Equation 17
where
l
pD
V
16
2
|
.
|
\
|
=
2
1
4 R
r D
r u
w
Equation 19
The flow rate can also be expressed as:
l
p D
Q
128
4
= Equation 20
The change in pressure is often written as:
2
2
V
D
l
f p
= Equation 21
where f is the friction factor. For fully developed laminar pipe flow:
Re
64
= f Equation 22
It also essential to consider energy losses in the pipe:
L
h z
g
V p
z
g
V p
+ + = = + +
2
2
2
2
2
1
2
1
1
1
2 2
Equation 23
For uniform velocity profiles _ = 1 and fro nonuniform velocity profiles _ > 1. The head loss,
h
L
, in a pipe is a result of the viscous shear stress on the wall.
D
l
r
l
h
w
L
4 2
= = Equation 24
When the pipe flow is considered to be turbulent, which probably will not occur, it is difficult
to accurately predict the effects of the fluid being transported in the pipe. Consultation of the
Moody chart is recommended.
The Rankine Cylcler operates on the idea of using steam to drive a turbine turning a shaft
connected to a generator; thus creating electrical energy from work energy. The Rankine
Cycler operates using an axial flow turbine. When the flow over a turbine blade is broken
down there are three components of velocity: absolute velocity, V, relative velocity, W, and
78
78
blade velocity, U. The blade velocity, U, is in the direction of the moving blade. The relative
velocity, W, is in the linear direction of the curve of the blade at a specified point on the
blade. The absolute velocity can be expressed as:
V = W + U Equation 18
When shaft torque3 and rotation are in the opposite direction a turbine is present. Fore
steady flow:
( ) ( ) dA n V V r F r
cs
} = Equation
and thus:
2 2 2 1 1 1
V r m V r m T
shaft
+ = Equation
The shaft poweris related to the torque and the angular velocity by:
shaft shaft
T W =
Equation
with U = wr:
2 2 2 1 1 1
V U m V U m W
shaft
+ =
Equation
and : / m W w
shaft shaft
=
2 2 1 1
V U V U w
shaft
+ = Equation
or:
( )
2
2
1
2
2
2
1
2
2
2
1
2
2
W W U U V V
w
shaft
+
= Equation
This is a simple overview of turbo machinery. Many different reference materials on axial
flow turbines and turbo machinery are available for a more in-depth detail on these subjects.
79
79
80
80
Vapor-Compression Cycle (Refrigeration Cycle)
The purpose of this experiment is to demonstrate and compare experimental parameters with
the theory for the thermodynamic refrigeration cycle (Vapor-Compression Cycle). The student
should be able to identify the individual components of the system and describe their function
and performance characteristics both qualitatively and quantitatively.
Introduction:
The basic cycle for a mechanical refrigerator is the ideal vapor-compression cycle. The T-s and
p-h diagrams are shown in Fig. 1.
Fig. 1 T-s and p-h Diagrams of a Vapor-Compression Refrigeration Cycle
Saturated vapor is compressed isentropically to a superheated vapor (process 1-2). The heat
rejection is carried out at constant pressure in the condenser (process 2-3). The fluid pressure
must be reduced by expanding the refrigerant through an expansion valve (TXV, AXV, or CTV)
in order to obtain a lower saturation temperature for the evaporator (process 3-4). The
refrigeration effect is accomplished in the evaporator at constant pressure (process 4-1). All
processes of the cycle are considered to be reversible except process 3-4, a throttling process
which is an irreversible process, and h
3
= h
4
.
Important.
Before the test, locate the location of state points 1, 2, 3, & 4 from Fig. 1, above, on the test
unit.
81
81
Apparatus:
1. Model 9001 Brodhead-Garrett Basic
Refrigeration Unit
2. Power measuring device (Watt meter)
82
82
Procedure:
1. Set unit on the refrigeration cycle using the
thermostatic expansion valve.
i. Open valve: HP4, TXV, HP1, AC1, and
ACO
ii. Close valves: HP3, FMB, HP2, ACB, AXV,
and CTV
(See
Capillary Tube Experiment Photos)
2. Open LRI, LRK, close LRB.
3. Put evaporator and condenser fan on high, and start
compressor.
4. After the system has run for 5 minutes, observe,
obtain and calculate the following:
a. The pressure and temperature at the principal points (1,2,3, and 4 on the T-
s and p-h diagrams. Record corresponding Thermocouple numbers.).
b. The flow rate of refrigerant.
c. Input power into compressor.
5. Repeat procedure 4 with evaporator fan on low.
Shut Down
Close LRB, and open LRV and operate until the suction pressure drops to 5 lbs.
Turn the compressor off.
Results:
1. Determine the enthalpy at each principal point by using a refrigerant table or chart.
2. Calculate:
a. Cooling Effect
Cooling Effect = m
refrigerant
(h
1
-h
4
)
b. Compressor power
P
comp.
= m
refngerant
(h
2
- h
1
) (Btu/min) (60min/hr)(1 Kw-hr/3412.2 Btu) = Watt
c. Efficiency of compressor
83
83
= P
comp.
(Watt) /P
input
(Watt)
d. Coefficient of performance
COP=(h
1
-h
4
)/(h
2
-h
1
)
e. Carnot coefficient of performance
(COP
Carnot
= T
1
/ (T
2
- T
1
)
f. Heat rejected
Q rej. = M
refrigerant
(h
3
- h
2
)
g. Determine horsepower required to produce 1 ton of refrigeration
(COP) = (tons of refrigeration) (12,000 Btu I hr) / (HP input) (2545 thu / hr)
= 4.715 / (HP/ton)
(HP / ton) = 4.715/ (COP)
h. Determine circulation rate of refrigerant for each ton of refrigeration
m
refrigerent
(lb/min) = (200 Btu/min) / (h1 - h4) Btu/Ib
1 ton of refrigeration =200 Btu of refrigeration / min.
84
84
85
85
VAPOR COMPRESSION REFRIGERATION CYCLE
DATA SHEET
DATE:
ROOM TEMPERATURE ____________
BAROMETRIC PRESSURE ________IN Hg = ________ PSIA
FAN SPEED REFRIGERANT TEMP. F PRESSURE PSIG
EVAP. COND. PT. 1
TC#
PT.2
TC#
PT. 3
TC#
PT. 4
TC#
POINT
1
POINT
2
POINT
3
POINT
4
HIGH HIGH
LOW HIGH
_
POWER INPUT TO SYSTEM (with compressor, condenser, and evaporator fan switch ON)
EVAPORATOR FAN ON HIGH & CONDENSER FAN ON HIGH _______________Watts
EVAPORATOR FAN ON LOW & CONDENSER FAN ON HIGH _______________Watts
POWER INPUT TO FANS (with compressor switch OFF)
EVAPORATOR FAN ON HIGH & CONDENSER FAN ON HIGH _______________Watts
EVAPORATOR FAN ON LOW & CONDENSER FAN ON HIGH _______________Watts
POWER INPUT TO COMPRESSOR = POWER INPUT TO SYSTEM
- POWER INPUT TO FANS
EVAPORATOR FAN ON HIGH & CONDENSER FAN ON HIGH _______________Watts
EVAPORATOR FAN ON LOW & CONDENSER FAN ON HIGH _______________Watts
REFRIGERANT FLOW RATE
EVAPORATOR FAN ON HIGH & CONDENSER FAN ON HIGH _______________Lb./min.
EVAPORATOR FAN ON LOW & CONDENSER FAN ON HIGH _______________Lb./min.
86
86
Pre-Test Report Format
Purpose
The Propose of the Pre-Test Report is to insure the persons conducting the test are familiar with
the objectives, data to be taken, and the underlying theory.
Format
The report is to be an informal memo. One page should be sufficient. Items to be included are:
Hypothesis (what do think will be proven and or learned?)
Simple test description
Basic Governing equations
Simplifying assumptions necessary.
Expected results (i.e. data ranges)
Simple Example:
Memo
To: Professor Carnot
From: Jimmy Neutron
Date: February 30, 1672
A test will be conducted to determine the flow thru a tube for various pressures. The upstream
pressure will be created by a variable speed blower. The down stream tube end will be open to
the atmosphere. A pitot tube with manometer will be used to measure the velocity in the tube.
Equations:
Measured Flow = velocity X area
P = 0.5 X Rho X V
2
Flow (Q) should be proportional to the square root of the pressure.
Assumptions:
The velocity profile across the tube is uniform (no boundary layer effects)
No effects will be caused by the turbulence introduced by the blower.
All Pressures will be less than 20 inches of water.
87
87
Memo Report Format
The memo Report will be about one page of text with data sheets, simple calculations, and
graphs attached if available. This report builds on the Pre Report and includes a brief discussion
of what was, or was not, proven. May include data, graphs, and an example calculation. Must
include a conclusion (one paragraph minimum.)
Information to include:
1. Hypothesis (what was expected to be proven?)
2. Simple test description (reference the test procedure for details.)
3. Governing equations / theory
4. Simplifying assumptions necessary.
5. Any problems incurred following the procedure.
6. What did the test prove?
7. Conclusion
88
88
1. Title Page:
_________________________________________________________________
University of North Carolina at Charlotte
William States Lee College of Engineering
Department of Engineering Technology
_________________________________________
(Title)
Date of Test: _______________
Course Title: _______________
Course Number and Section: _______________
Report Author: _______________
Report Due Date: _______________
Lab. Partners: _______________________________________
Instructor: _______________
89
89
2. Table of Contents:
_______________________________________________________________
Table of Contents
Section Page
Theory
Procedure
Results
Conclusions
References
Appendix
3. Theory
This section includes a review of the pertinent theory relevant to the experiment. This section
also is included to allow the student to investigate more fully the principles being demonstrated
by the experiment. It is expected that this section will contain more than a repeat of the theory
discussion in the laboratory manual. Sources from the bibliography should be used to develop
the theory in detail, including relevant derivations.
4. Equipment List
All equipment used in the experiment is listed in this section, including the name or description
of each piece equipment, the manufacturer, model number and serial number. It is very
important to specifically identify each piece of equipment used, since any discrepancies in the
data may be due to faulty equipment, which may not be discovered until the data analysis is
completed. Without being able to reconstruct the experiment, it may not be possible to explain
poor results.
5. Procedure
The methods and operations followed in carrying out the experiment should be described in
sufficient detail so that another person would be able to exactly repeat the experiment From this
section, the reader should be able to obtain a clear understanding of what the experiment was
and how it was done. Differences in procedure from the Lab. Manual or equipment malfunctions
should definitely be recorded.
90
90
6. Results, Analysis and Discussion
This section is most important, since the interpretation of the experimental data is presented
here, supported by graphs and tables, with a discussion of variations from expected results.
Results should be more than presentation of graphs and tables. The results should be
interpreted for the reader and thoroughly discussed since they form the basis for conclusion.
Calculations required for the generation of tables and graphs should be explained and sample
calculations presented. Any assumptions in the interpretation of the data should be listed.
Graphs and tables should be supported by the original data sheets, which should be included in
the appendix of the report. When only one data sheet was taken during the experiment, copies
should be made for each of the partners in the group. Neatness in original data sheets is very
important for future interpretation.
Possible improvements in equipment and procedure should be discussed.
7. Conclusions
This section is the students opportunity to show that he understands the significance of the
results. Discrepancies in the results should be addressed, sources of error should be identified
and explained, and recommendations for changes in equipment or procedure should presented.
8. References
Publications referred to in the final report are listed in the references section. -
The references are numbered in the order of their mention in the text, tables and figures. Only
formal documents may be listed as references. If necessary, acknowledgement of other informal
sources, such as private communications should be made in the text; e.g. (private
communication from John Doe, Blank Co., City, State).
Each reference should contain the following information in the order given:
a) Author: Surname, first name, or initials as given on the reference. If anonymous, the
listing is started with the title.
b) Title: Exact title as given.
c) Subtitle: If on separate line from main title, separate by a period; otherwise exactly as
written. - -
d) Source:
1) Book Volume number and subtitle, if any; edition; publisher; place of publication
if publisher is foreign or not well known; date (use copyright date if no other date
appears); page numbers.
2) Periodical: Name of periodical; volume; number; month; year; inclusive pages. If tide of
periodical has changed, give correct tide for issue cited.
91
91
9. Appendix -
An appendix presents supplementary information that does not logically fit into or might
otherwise interfere with an orderly plan for the text It is material that is important, but not
essential to the development of the report (such as the raw data, rough calculations and
calculations that are not used as examples.
Each appendix must be referred to in the text and must have a title. Appendixes are identified by
capital letter (A, B, C, etc.) in the order mentioned in the report.
Each appendix begins on a new page, with the appendix designation on the first line and the
title below it.
Appendixes include:
the original data sheet
Calculations-other than sample calculations
Handout materials
Miscellaneous - published tables and charts, etc. manufacturers instructions, copies of
calibration certificates, etc.
(Original Data Sheet - readings taken during an experiments should be recorded in such a
manner that all items are complete and understood by all persons conducting the experiment
The heading of the sheet should indicate the date, title and number of the experiment, and the
name of the observer or observers. Column headings should indicate the name of the item
recorded, with units. Instrument serial numbers should be recorded. When in doubt about the
amount of information to record, it is better to record more information than is thought
necessary. Especially record any deviations from the recommended procedure, since these may
be important in accounting for deviations in results).
General Requirements
a) Always use past tense. The only exception is in the Results section.
b) Always use third person.
c) Write complete English sentences throughout. The only exceptions are title, table, and
Figure legends.
d) Reports should be typewritten on one side of white paper of good quality only and
Double-spaced. When word processing program are used, the font used should be one that
is easily read - no Gothic or other elaborate fonts.
e) Each new section begins double-spaced down from the previous section.
92
92
Report Layout
Each illustration or table must follow the text reference as close as possible.
Pages (8-1/2 by 11 inches) should be typed within the 6-1/2 by 8-1/2 inch dimensions. (1-inch
margins on top, right and left margins; 1-1/2 inch margin on bottom)
All vertical illustrations should be within the 8-by 6-1/2 inch image area.
All horizontal illustrations should be within the 8-1/2 by 6 inch image area.
Double space to separate the text and the top of the illustration area; double space to separate
the bottom of the illustration area and the figure title; and double space to separate the title from
the following text.
Tables, charts, and graphs
Reference data is normally presented in tabular or chart form. Charts and graphs are assigned
figure number and titles and should appear at the bottom of the chart or graph. The tide should
be as descriptive as possible. The coordinate axes should be set far enough inside the margin
to allow room for scale information. Scales should be selected to allow the best display of data.
Unrelated curves should not appear on the same sheet. Related curves may be on the same
graph, provided they are completely identified with different symbols, i.e. crossed, triangular,
etc. Experimental errors are such that plotted points may not fall along a smooth line. Generally,
however, smooth curves should be drawn with a French curve so as to provide a good fit to
the data. Plotted points should be shown on the graph. The exception to this rule is a plot of a
calibration graph, in which lines should be drawn from point to point. Free hand graphs are not
acceptable. A table number and title should be placed above the table. Titles should be
descriptive, not just Table No. 1. Each column should have a heading with a description of the
item in the column. Each column should have units, as appropriate. Tables should be oriented
so that the bottom of the table is at the bottom of the page or at the right - hand margin. No
writing should be placed in the margins. Tables should be complete on one page, where
possible.
Copyright 2004. Material in this document is for your personal use only. This document
contains copyrighted and other proprietary information. You may not in any way make
commercial or other unauthorized use, by publication, re-transmission, distribution, caching, or
otherwise, of this material, except as permitted by the Copyright Act or other law.