Adept catalogue
Adept catalogue
com
Electromagnetic Flowmeter
of 1800 mm dia.
2
From CEO’s desk
Dear friends,
L
An ambitious spirit, clear focus on the future and an urge to manufacture innovative, precision
products - that's how Adept is characterised since inception.
Krishnaji Gadre - a visionary and dynamic entrepreneur - laid the foundation of Adept in early 50s by
indigenously developing laboratory equipments and weather recording instruments. With the rapid
industrialisation and advent of electronics, the technology demands in industries were rapidly
changing. Over the years, we responded to this change by introducing new technologies and
venturing into new business verticals.
In the year 1992, a major breakthrough occurred when a renowned company approached us with its
requirement of developing a Flowmeter. We responded to it with our inherent enthusiasm, conducted
an extensive R&D and successfully developed the first Adept Electromagnetic Flowmeter. When its
performance and accuracy were undoubtedly proved during field trials, we were encouraged to
entrench further in this field.
During the last 2 decades, Adept proved its capability in several fields, and today, we are known for
providing appropriate instrumentation solutions with efficient services to industries such as water,
waste water, chemical, pharmaceutical, paper, cement, mining, mineral & metal, power, oil & gas,
food & beverages and so on.
Our success is attributed to our core competency in meeting most challenging requirements with
highly precise products of the latest technology, and in providing efficient services.
Adept products are manufactured in a well-equipped plant and rigorously tested before despatch.
No wonder, they perform precisely over the years. Our well-equipped service support for repair,
maintenance, calibration and technology upgradation is also an assurance of extended life for your
products while ensuring a lower life-cycle-cost.
The awaited NABL accreditation will give a boost to our quality manufacturing and will authenticate our
calibration capabilities. This will also open the doors of the world markets for Adept.
Welcome to Adept. Our qualified team of engineers and technicians will always ensure that you get
more technology, more reliability, more service and more economy than what you expect from your
usual instrumentation partner.
Sincerely yours,
L
Vinayak Gadre
Director
3
About us
Adept is an ISO 9001:2008 company with more than
3 decades of experience in instrumentation. The activities
Design & Development Centre
include Electric Transducers, Chart Recorders, Signal Equipped with the latest design and development tools
Isolators and Flowmeters. We have more than 150,000 such as CAD and microprocessor development systems.
installations across India and abroad in various types of The experienced and competent team ensures quality
industries. Our nationwide sales and service network and pace of the development process. Apart from new
ensures efficient pre and post sales services to our product development, we also help in providing
esteemed customers. Our quality products are customised solutions for challenging requirements.
manufactured in a well-equipped plant in Pune, India.
4
Electronics Manufacturing
All PCB designing work is carried out in-house, using
advanced softwares. PCB assembly is carried out by a
highly skilled and trained team, which ensures high level of
precision and quality. The PCB assembly section is also
equipped with environment chamber and other custom-
designed test jigs and fixtures to ensure high quality
standards.
5
Quality at every step
Reliability in every aspect
Mechanical Manufacturing
In-house facilities for machining, fabrication and finishing.
This allows us to ensure faster production and exercise
precise control on manufacturing accuracy. Additionally,
the quality of input material is guaranteed. Achieving
greater synchronisation with other production activities is
also possible, which helps in executing large orders in the
shortest possible time.
6
Quality Assurance Calibration Laboratory
All incoming material is thoroughly inspected for physical
One of the first of its kind since 1994
accuracy and adherence to specifications. During the
manufacturing process, at every step, a stage inspection Calibration as per ISO 4185 using primary method of
measuring water flow by gravimetric principles or by
is conducted by expert engineers. The major tests include
comparison method
heat test, humidity test, insulation test, HV test, hydraulic
pressure test and Phantom load testing. After this, every Present capacity : Up to 450 mm
assembled product undergoes a rigorous inspection and A separate quick calibration set up : Calibration of
testing at the final stage before being despatched. Flowmeters up to 150 mm line size in just 15 minutes
Expansion up to 1000 mm being planned
7
perpendicular to both the liquid flow direction and the
electromagnetic field direction. The voltage sensed by the
electrodes is further processed by the transmitter to give
standardised output signal or displayed in appropriate
engineering unit.
E = KxBxvxD
where E : Induced voltage
K : Flow tube constant
B : Magnetic field strength
v : Mean flow velocity
and D : Electrode spacing
ExDxB
Therefore, Q =
MagFlow 6410 KxBx4
MagProbe 6450
EcoMag 6420
MagBP 6440
8
Technical Specifications : Series 6400
Parameters MagFlow 6410 EcoMag 6420 MagBP 6440 MagProbe 6450
Nominal dia (mm) 10 to 2000 10 to 150 10 to 1000 > 100
2
Working pressure (kg/cm ) 10, 16, 25, 40 5 10, 16, 25, 40 20
0 0 0
Working temperature Integral PTFE - 120 C Up to 55 C Up to 55 C Up to 1200C
Remote PTFE - 1800C
Others - 700C
Electrode material SS 316 Std.* SS 316 Std.* SS 316 Std.* SS 316 Std.*
Sensor lining Std. Rubber* NA Std. Rubber* NA
Display version Integral/Remote Integral/Remote Integral/Remote Integral/Remote
Measuring tube material SS304 Std.* HDPE SS304 Std.* SS316 Std.*
Sensor housing material Std. CS* HDPE Std. CS* NA
End connection Flange/Wafer/Tri-clamp Flange Flange/Wafer/Tri-clamp NA
Flange - Standard ANSI 150* ANSI 150* ANSI 150* NA
Measuring range 0.2 to 12 m/sec. Bidirectional 0.2 to 12 m/sec. Bidirectional 0.2 to 12 m/sec. Bidirectional 0.2 to 12 m/sec. Bidirectional
Accuracy % of measured value ±O.5 (±O.2% consult factory) ±1% ±1% ±2%
Repeatability ±0.2% of span ±0.2% of span ±0.2% of span ±0.2% of span
Display 2 line LCD/LED 2 line LCD/LED 2 line LCD 2 line LCD/LED
Display units All standard engineering All standard engineering All standard engineering All standard engineering
units in units in units in units in
m3, litre, gallon, ft3, m3, litre, gallon, ft3, m3, litre, gallon, ft3, m3, litre, gallon, ft3,
Imperial gallon Imperial gallon Imperial gallon Imperial gallon
Output Std. 4-20 mA* Std. 4-20 mA* NA Std. 4-20 mA*
Power supply 24 V DC or 24 V DC or Battery powered 24 V DC or
80-300 V AC 80-300 V AC 5 years battery life 80-300 V AC
9
Electromagnetic Flowmeter Components
Cable gland
Transmitter
Display
Earthing ring
Coil housing
Liner (Rubber/PTFE)
Flange
Installation precautions
1. Installation location should be such that the Flowmeter will always remain full with liquid.
2. A minimum 5D upstream & 3D downstream straight lengths should be maintained at installation locations where D is the pipe diameter.
3. The Flowmeter installation location should be free of bends, elbows, tees, valves, etc.
10
Ordering Code : Series 6400
Approval
M1 - MagFlow 6410 Sensor Size D - None
M2 - EcoMag 6420 0010 - 10 (¼”) F - Flameproof
M3 - MagBP 6440 0015 - 15 (½”) G - Any other
(Pl. specify)
M4 - MagProbe 6450 0020 - 20 (¾”)
0025 - 25 (1”)
Transmitter Type 0032 - 32 (1.25”)
I - Integral Protection Class
0040 - 40 (1.50”) for Sensor
R - Remote 0050 - 50 (2”) A - IP 65
0065 - 65 (2.5”) B - IP 67
View Software
0080 - 80 (3”) C - IP 68
Y - Required
(select communication interface) 0100 - 100 (4”)
N - Not required 0125 - 125 (5”) Coil Housing
0150 - 150 (6”) CH1 - CS / MS
Power Supply
0200 - 200 (8”) CH2 - SS 304
P1 - 24 V DC
0250 - 250 (10”) CH3 - SS 316
P2 - 80 to 300 AC
0300 - 300 (12”) CH4 - Any other
P3 - Solar powered
0350 - 350 (14”) (Pl. specify)
P4 - Battery powered
(6420, 6440, 6450) 0400 - 400 (16”)
P5 - Any other (Pl. specify) 0450 - 450 (18”) Measuring Tube
0500 - 500 (20”) T1 - SS 304
Output T2 - SS 316
0600 - 600 (24”)
OP1 - 4 - 20 mA DC T3 - Any other (Pl. specify)
0700 - 700 (28”)
OP2 - 0 - 20 mA DC
0800 - 800 (32”)
OP3 - Pulse output
0900 - 900 (36”) Earthing Rings
OP4 - Relay output
1000 - 1000 (40”) 1 - None (Earth electrode)
OP5 - Combinations of above
1200 - 1200 (48”) 2 - SS 316
OP6 - Any other (Pl. specify)
1400 - 1400 (56”) 3 - SS 316L
Communication Interface 1600 - 1600 (64”) 4 - Any other (Pl. specify)
C1 - Not applicable 1800 - 1800 (72”)
C2 - RS 232 (Modbus RTU) 2000 - 2000 (80”) Electrode Material
C3 - RS 485 (Modbus RTU) Any other (Pl. specify) E1 - SS 316
C4 - HART E2 - SS 316L
C5 - GSM E3 - Hastelloy C
C6 - GPRS E4 - Titanium
Data Logger E5 - Tantalum
Y - External (Pl. specify) E6 - Platinum
N - Not required E7 - Any other (Pl. specify)
Note : For MagProbe 6450 Insertion Type Flowmeter - sensor size, design of measuring sensor, flange material, sensor lining, earthing, coil
housing choices are not available.
11
Working Principle
The Transit Time Flowmeter utilises two transducers that With flow, sound will travel faster in the direction of flow
function as both ultrasonic transmitters and receivers. and slower against the flow. The liquid velocity (V) inside
The transducers are clamped on the outside of a closed the pipe can be related to the difference in time of flight
pipe or inserted in the pipeline by use of isolating ball valve (rt) through the following equation:
assembly at a specific distance from each other. Transit
Time Flowmeters measure the time it takes for an V = KxDxrt
ultrasonic signal transmitted from one sensor, to cross a where V : Liquid velocity
pipe and be received by a second sensor. Upstream and K : Constant
downstream time measurements are compared. With D : Distance between the two transducers
no flow, the transit time would be equal in both directions. rt : Difference in time of flight
12
Ultrasonic Flowmeter Series 6700
Transmitter
Power supply 24 V DC ±20% 3 AAA NiMH built-in battery 24 V DC ±20%
110 V AC ±15% (12 hours of operation) & 110 V AC ±15%
240 V AC ±15% 100-240 V AC for the charger 240 V AC ±15 %
Velocity ±12 m/sec. Bidirectional ±12 m/sec. Bidirectional ±12 m/sec. Bidirectional
Display 2 lines, 16 characters, 4 lines, 16 characters, 2 lines, 16 characters,
LCD with back light, flow rate, LCD with back light, flow rate, LCD with back light, flow rate,
velocity, totaliser velocity, totaliser velocity, totaliser
Units User configurable English/Metric User configurable English/Metric User configurable English/Metric
Totaliser FWD, NET, REV, BATCH FWD, NET, REV, BATCH FWD, NET, REV, BATCH
(Gallons, ft3, Barrels, lbs, m3 ) (Gallons, ft3, Barrels, lbs, m3 ) (Gallons, ft3, Barrels, lbs, m3 )
Output 4-20 mA DC Std.* RS 232 4-20 mA DC Std.*
Accuracy ±1% of reading @ rate >0.5 m/sec. ±1% of reading @ rate >0.5 m/sec. ±1% of reading @ rate >0.5 m/sec.
Repeatability 0.2% of Span 0.2% of Span 0.2% of Span
Dimensions 251x190x96 mm 204x90x30 mm 251x190x96 mm
Weight <2.5 kg <0.5 kg <2.5 kg
Security Keypad lockout, access code enabled Keypad lockout, access code enabled Keypad lockout, access code enabled
Transducer
0 0
Suited temp. - Std. -40 C to 120 C -400C to 1200C -400C to 1200C
0 0 0 0
Suited temp. - High -40 C to 250 C -40 C to 250 C -400C to 2500C
S Transducer 15-80 mm 15-80 mm >65 mm
Pipe size M Transducer 50-700 mm 50-700 mm (Note : Long sensors available
L Transducer 400-4570 mm 400-4570 mm on request for thick pipelines)
S Transducer 45x30x30 mm 45x30x30 mm
Dimensions M Transducer 60x45x45 mm 60x45x45 mm 186 mm with 20 mm bore size
L Transducer 80x70x55 mm 80x70x55 mm
S Transducer < 0.3 kg < 0.3 kg
Weight M Transducer < 0.5 kg < 0.5 kg < 1.5 kg
L Transducer < 1.0 kg < 1.0 kg
Cable length 6 m Std. Can be extended up to 300 m 6 m Std. Can be extended up to 25 m 6 m Std. Can be extended up to 300 m
Flexible belts SS belt according to pipe size SS belt according to pipe size NA
Portable case NA Size - 463x383x103 mm NA
* Please refer to order code for options.
13
Ordering Code : UFM 6710/6730
14
UFM 6740
Ultrasonic Water Meter
Benefits
This is a battery-powered, transit-time Long term stability and accuracy over a wide range of conditions
Flowmeter utilising advanced digital High reliability and minimum maintenance requirement
processing technology. The meter Maintenance-free meter where no external power sources are
contains no moving parts and does not available
require any external power. It also has
Communication port permits transfer of data from remote stations
advantages such as ultra-low power
to central system via GSM - GPRS Modem
consumption, high accuracy and
reliability. The meter is designed for easy Self-adjusting transducer receiving circuit continually adapts to
installation. It has the same conduit changing pipe diameters due to scaling or corrosion
length with industrial mechanical water Fast response to flow transits
meter, but can be used just as Available with AMR function
conveniently as a mechanical water Battery life - 5 years
meter. Unique housing design rated to IP 68
On-board self diagnostic function and fault indicator
Technical characteristics Low power consumption, digital process technology with stable & permanant PiezoSeal sensor
Display Total flow, flow rate, velocity, working time & date, signal intensity, quality & battery status
Output RS 485,4-20 mA, Pulse for total flow (All outputs need external power supply 24 V DC)
Enclosure class IP 68
15
Ordering Code : UFM 6740
16
Adept Flowmeters in water network
with SCADA & GSM - GPRS connectivity
Site/ location 01
Fresh water is a precious resource. Our industries rely on
it to manufacture life’s luxuries and necessities. Without
water, we wouldn’t exist. But, less than 3% of the world’s
water is fresh.
GP
Site/ location 02
losses. Adept understands the problem of metering and
ail
m
E-
GP
RS provides solution in the form of AMR (Automatic Meter
Reading) using GSM - GPRS System.
SMS
Internet
Adept Flowmeters at different locations can be monitored
Site/ location 03
GP
RS with central SCADA or readings can be obtained directly
on mobile with the help of GSM or GPRS System. Even
SMS Battery Powered Flowmeters can be supplied with GSM -
RS
GP
Adept has developed SCADA software to retrieve data from Flowmeters installed at remote sites. The software is used to
collect, view and print data. Through the compilation and analysis of such data, it is possible to understand usage pattern
and take corrective measures for optimising usage of precious resources.
17
Other Products
Series 2000 : Power Line Transducers, Meters
Adept offers various analog Power Line Transducers along with Programmable Multi-function Transducers and Meters for measurement of various single
phase and 3 phase electrical parameters such as current, voltage, frequency, power factor, active / reactive / apparent power and active energy.
Input AC current, DC output Measures and outputs various electrical Measures and displays various electrical
Single or Dual parameters on RS 485 Modbus and up to parameters on LED or LCD display.
Accuracy : 0.5%, 0.2% 4 nos. of analog outputs. Single phase, RS 485/RS 232 Modbus RTU
3 phase, 3 wire / 4 wire (selectable) communication interface. Single phase,
Accuracy 0.5%, 0.2% 3 phase, 3 wire / 4 wire (selectable)
Accuracy 0.5%, 0.2%
Input : 4-20 mA DC
Output : 4-20 mA DC DC Voltage Input Inputs : Flow, Inlet and outlet temperatures Input : 6 channels
No auxiliary supply required DC Output Display : BTU, BTUh, kW, kWh Output : RS 485 (Modbus RTU)
Adept offers various 4 Wire Type Isolators for Adept offers BTU Meter 6430 to measure Data Scanner 8000 replaces multiple
measurement of parameters like DC current, Thermal energy flow rate and total energy analog DC Signal Transducers and
DC voltage along with Temperature, Resistance consumption in liquid heating and cooling combines 6 programmable channels into
and Transformer Tap. applications. a single product. The product features
user-selectable inputs such as mV DC,
mA DC, V DC.
18
Credentials
Registrations/Approvals : APGENCO GWSSB MJP MP JAL NIGAM MSEDCL NTPC PGCIL PHED RAJASTHAN
Testimonials
Angeripalayam C.E.T.P. Ltd. Kirloskar Brothers Limited
“Working of Adept Flowmeter is good and we are satisfied with your “Adept Flowmeter size DN 400 is working satisfactorily since 2010.”
service.”
Mechatronics Systems Pvt. Ltd.
Electronics Corporation of India Ltd. “Adept Flowmeters installed at Morshi Dam are working satisfactorily for
“Series 6400 Electromagnetic Flowmeters (full bore type) installed in the the last 10 years.”
year 2000 are a true replacement to German make Flowmeters and
performing to our satisfaction.” Panipat Thermal Power Station
“Adept Flowmeters installed during 2004 are functioning flawlessly from
Godrej & Boyce Ltd. day one.”
“Adept Flowmeter Series 6400 & Ultrasonic Flowmeter Series 6700
installed in 2011 are working satisfactorily till date.” Pune Muncipal Corporation
“Electromagnetic Flowmeters installed at Parvati Water Pumping Station
Gujrat Industries Power Company Ltd. are functioning properly since the year 2009.”
“Adept Flowmeters installed in 1997 at our Bodhan river water pump
house are working satisfactorily.” Reliance Energy Ltd.
“Adept Electromagnetic Flowmeter of Series 6400 is installed at our
JSW Steel Ltd. effluent treatment plant of 220 MW combined cycle power plant in the
“We have purchased a number of Ultrasonic & Electromagnetic year 2003-04 and the performance is satisfactory.”
Flowmeters from Adept including one of 1000 mm dia. We have
monitored the performance continuously and found it to be Talco Vaniyambadi Tanners Enviro Control Systems Ltd.
satisfactory.” “Series 6400 Flowmeters with flow indicator and totalisers are installed in
our common effluent treatment plants at Valayampet and Udayendiram
sectors in 1996 and are performing well.”
19
Sales and Service Network
Delhi
Jaipur
Ahmedabad Bhopal
Kolkata
Mumbai
«Pune
Hyderabad
« Corporate Office & Plant
Regional Office
Dealer
Bangalore Chennai