0% found this document useful (0 votes)
3 views

PI_RM210_

The RM210 is a versatile measuring device utilizing scattered light technology to detect dust concentrations ranging from < 0.5 to 200 mg/m3, suitable for various duct sizes. It features real-time measurement capabilities, automatic contamination checks, and compliance with environmental regulations. The device is designed for harsh industrial environments and offers multiple applications including monitoring clean gas and exhaust systems.

Uploaded by

a.abdelmoaty
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

PI_RM210_

The RM210 is a versatile measuring device utilizing scattered light technology to detect dust concentrations ranging from < 0.5 to 200 mg/m3, suitable for various duct sizes. It features real-time measurement capabilities, automatic contamination checks, and compliance with environmental regulations. The device is designed for harsh industrial environments and offers multiple applications including monitoring clean gas and exhaust systems.

Uploaded by

a.abdelmoaty
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

P r o d u c t i n f o r m at i o n

RM210
Scattered Light Technology

Intelligent Solution for a Cleaner Air

Versatile measuring device Measurement principle


Key features of RM210
Based on the scattered light measur- The insitu technology of the RM210,
ing principle, the RM210 detects dust i.e direct measurement in the gas
concentrations within a range of < 0.5 duct, guarantees instantaneous • Representative recording of
to 200 mg/m3. Suitable device ver- measured values. The measured dust loads in ducts with large
sions with different measuring pen- quantity of the RM210 is scattered diameters and/or with thick
etration depths are available for out- light. The light source transmits infra- walls
putting of representative red light which is scattered by the par- • Additional recognition of defec-
measure- ment results: ticles in the gas stream and detected tive filter pockets alongside
by a highly sensitive sensor. This mea- dust measurement
• Version 1 for small gas ducts with surement principle enables precise • Cyclic monitoring of device
ø 0.2 ... 1.5 m dust concentration measurements functions via zero-point and
• Version 2 for ducts and small from the scattered light intensity mea- reference-point comparison
stacks with ø 1.5 ... 3.5 m surement (calculated on the basis of • No disturbance caused by con-
• Version 3 for stacks with ø >3.5 m gravimetric calibration). tamination due to automatic
contamination measurement
The highly flexible RM210, with its ro- of all optical components and
Applications a measurement value correc-
bust design is ideal for application in
harsh industrial environments. tion
• In clean gas upstream of • Easy to perform linearity meas-
Equipped with freely adjustable
electrostatic precipitators urements (4 measurement
measurement ranges the RM210 is
or fabric filters points)
able to perform versatile measuring
• Monitoring of exhaust and • Data transmission (RS232) by
functions. It complies with 13th and
fresh air systems modem for diagnostics, para-
17th BImSchV, with the Clean Air Act
• Protection of gas turbines meter setting and recording of
and the new Waste Incineration Direc-
tive EN-14181. measured value.

Analyzers and Process Instrumentation


8007395/2004-12/BW • Printed in Germany (2006-01) • Subject to change without prior notice

RM210 Device Overview

Device version 1: 60°/60° *)

MEPA software for Detection area


Connection unit parameter settings approx. 165 mm

Device version 2: 90°/60° *)

Detection area
115/230 V approx. 530 mm
power supply Light
absorber
Analog/binary
signals
Sender/ Device version 3: 90°/70° *)
receiver unit

� � � � � �� �� �� �� �� ��

SLV 4 purge air unit

Detection area
approx. 1280 mm

Light
absorber

*)
Angle position of the optical axis sender/receiver towards the housing front

Technical Data RM210


Measuring data
Measuring principle Scattered light principle (scattered light intensity proportional to dust concentration)
Measuring range
•Smallest range 0 … 0.5 mg/m3
•Largest range 0 … 200 mg/m3
Accuracy ± 2 % of full scale value
Response time 1 … 255 s
Plant data
Measuring gas temperature Above dew point up to 500 °C (932 °F), higher temperatures on request
Ambient temperature –20 ... +55 °C (–4 ... 130 °F)
Measuring gas pressure Max. +0.6 hPa/+60 mbar (24 in WC)
Device data Sender/receiver unit Connection unit
Purge air supply Refer to SLV4 data sheet; order no. 8008080
Power supply 90 ... 260 V AC; 47 ... 63 Hz; 20 VA power consumption
Storage temperature –20 ... +65 °C (–4 ... +150 °F); storage humidity 50 % r.h.
Dimensions

L x W x D in mm3 (in3) 210 x 495 x 276 (8 x 19.5 x 11) 196 x 203 x 162,5 (7.7 x 8 x 6.4)
Weight approx. 12 kg (26.5 lb) approx. 3.5 kg (7.7 lb) Flange: approx. 4.5 kg (10 lb)
Protection class IP 65/NEMA 4x
Interfaces and signals
RS232 service interface
Interfaces to periphery
RS422 interface to remote control unit (option) or host computer
Signals 2 analog outputs: 0 … 20 mA, 100 Ω (electrically isolated)
4 status inputs: 10 … 35 V DC/10 … 25 V AC; selectable
4 relay outputs: 48 V DC/1 A; selectable

SICK MAIHAK GmbH | Analyzers and Process Instrumentation


Nimburger Str. 11 | 79276 Reute | Germany | www.sick-maihak.com
Tel. +49 7641 469-0 | Fax +49 7641 469-1149 | [email protected] Analyzers and Process Instrumentation