0% found this document useful (0 votes)
13 views2 pages

AS 3000

The AquaSensor AS 3000 is an advanced sensor for online detection of water in oils, designed for condition monitoring in hydraulic and lubrication systems. It measures water saturation and temperature, providing outputs in 4-20 mA or 0-10 V signals, and features a user-friendly display for real-time monitoring. The sensor is pressure-resistant, compact, and requires no calibration for different oil types, making it suitable for various industrial applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views2 pages

AS 3000

The AquaSensor AS 3000 is an advanced sensor for online detection of water in oils, designed for condition monitoring in hydraulic and lubrication systems. It measures water saturation and temperature, providing outputs in 4-20 mA or 0-10 V signals, and features a user-friendly display for real-time monitoring. The sensor is pressure-resistant, compact, and requires no calibration for different oil types, making it suitable for various industrial applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AquaSensor

AS 3000

Description Technical specifications


The AquaSensor AS 3000 is the
Input data
further development of the proven
AS 1000 series for the online Level of saturation 0 to 100 %
detection of water in oils, particularly Temperature -25 to 100 °C / -13 to 212 °F
as a sensor for condition monitoring. Operating pressure -0.5 to 50 bar / -7.25 to 725 psi
Pressure resistance ≤ 630 bar / 9136 psi
It records the water saturation and the
Flow velocity max. 5 m/s
temperature of the operating fluid.
Parts in contact with fluid Mechanical connection: stainless steel /
The display allows you to view the vacuum-metallised ceramic
current measured values or to adjust Seal: FKM or EPDM per type
the parameter settings. Output data
The measured values are output as Analogue output
a 4 ... 20 mA or 0 ... 10 V signal and Output signal (parameterisable) 4 to 20 mA ohmic resistance ≤ 500 Ω or
are the basis for two parameterisable 0 to 10 V ohmic resistance ≥ 1 kΩ
switching outputs. corresponds to the measurement range
The AS 3000 thus enables hydraulic factory setting selected in each case:
and lubricating oils to be monitored 4 to 20 mA
accurately, continuously and online. Calibration accuracy ≤ ± 2 % FS max.
Accuracy in media measurements ≤ ± 3 % FS typ.
Pressure dependence ± 0.2 % FS / bar
Applications Switching outputs
zzMobile hydraulics Version (parameterisable) PNP transistor outputs
zzHydraulic and lubrication systems in Normally open or normally closed
industry Factory setting: normally closed
Allocation (parameterisable) Degree of saturation or temperature
Factory setting: degree of saturation
Advantages (alarm 80% (SP 1), warning 60% (SP 2),
zz4 digit digital display, can be aligned activation temperature: 30 °C / 86 °F)
in two axes Switch current maximum 1.2 A per output
zzUser-friendly due to key Switch cycles > 100 million
programming Ambient conditions
zzIndividual configuration Nominal temperature range (saturation) 0 to +80 °C / 32 to 176 °F
Storage temperature range -40 to +80 °C / -40 to 176 °F
zzReliable on account of its compact,
Fluid temperature range -40 to +80 °C / -40 to 176 °F
rugged design
Viscosity range 1 to 5000 mm2/s
zzEconomical sensor Fluid compatibility mineral oil based fluids,
zzNo calibration required for different synthetic and natural esters per type
oil types -mark EN 61000-6-1 / 2 / 3 / 4
zzPressure-resistant, even with Protection class to DIN 40050 IP 67
pulsations Other data
zzEarly detection of water problems Supply voltage 18 to 32 V DC
thus preventing faults and Residual ripple of supply voltage ≤ 5%
unnecessary interruption to Electrical connection M 12x1, 5 pole
operations Display 4-digit, LED, 7-segment, red,
height of digits 7 mm
Mechanical connection G3/8 A acc. to DIN 3852
Torque value 25 Nm
EN 7.636.3/06.19

Weight ~ 110 g
Note: reverse polarity protection, short circuit protection provided.
FS (Full Scale) = relative to the full measuring range

59
Items supplied
Order details –– AquaSensor
AS 3 0 0 8 – 5 – 000 –– Operating manual
Type
AS = AquaSensor Pin connections
M12x1, 5 pole
Measuring range
3 = 3000 Series
Medium 4 3
0 = Mineral oils 5
1 = Phosphate ester (HFD-R)
1 2
Mechanical connection
0 = G 3/8 A DIN 3852
Electrical connection
8 = Male connector M12x1, 5 pin
(female connector not supplied) Pin Assignment
Signal technology 1 Voltage supply 18-35 VDC
5 = 2 switch outputs / 1 analogue output 2 Analogue output
Modification number 3 GND supply voltage
000 = standard
4 SP 1 (alarm)
5 SP 2 (warning)
Dimensions
Accessories
Ø 42
25.2 40.4 ZBE 08
M 12 x1 11 Female connector, bent, shielded,
5 pin, M12x1
Part no. 6006786

ZBE 08S-02
Female connector, right-angled,
16.1

with 2 m cable, shielded, 5 pin, M12x1


76.2
92.7

Part no. 6019455


65.3

ZBE 08S-05
Female connector, right-angled,
2.5

with 5 m cable, shielded, 5 pin, M12x1


27 Part no. 6019456
12

30

135° ZBE 47S-05


Female connector, straight,
Ø 12 16.1
G3/8A
with 5 m lead, shielded, 5 pin, M12x1
Ø 21.9 -0,2 Part no. 3484562
Ø 29.5 -0,05
Ø 53.5
135° PS5
Power supply unit with socket plug
(female), 5 pole, M12x1
Part. no. 3399939

170°
M12x1, 5pol 170°
All dimensions in mm

HYDAC FILTER SYSTEMS GMBH


NOTE Industriegebiet
EN 7.636.3/06.19

The information in this brochure relates to the operating conditions and applications D-66280 Sulzbach / Saar
described. Tel.:+49 (0) 6897/509-01
For applications and operating conditions not described, please contact the proper Fax:+49 (0) 6897/509-9046
HYDAC department. Internet: www.hydac.com
Subject to technical modifications. E-Mail: [email protected]

60