Note: (1) Serial interface always present, also for -BC and -BP options
F410
3 HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 °C)
Hydraulic symbols
Note:
In three-way versions port P is open.
In two-way versions port P must be plugged. QVHZO-A QVHZO-AE
Port T must always be plugged. QVKZOR-A QVKZOR-AE
4 GENERAL NOTES
QVHZO and QVKZOR proportional valves are CE marked according to the applicable Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive).
Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes
supplied with relevant components.
The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions, like to switch-ON/OFF the machine’s safety
components, as prescribed by the European standards (Safety requirements of fluid technology systems and components-hydraulics, EN-982).
5.1 Option /6 6 VDC coil instead of standard 12 VDC, to be used in case of power supply 12 VDC
5.2 Option /18 18 VDC coil instead of standard 12 VDC, to be used with electronic drivers not supplied by Atos
5.3 Option /D This option provides a quick venting of the user line when the valve is closed or de-energized.
The following options allow to operate the valve in absence of electrical power supply by means of a micrometric screw replacing the standard solenoid
manual override, see table K500
5.4 Option /N manual micrometric adjustment
5.5 Option /NV as N plus handwheel and graduated scale
MAIN CONNECTOR
7 PIN - STANDARD
SCALE BIAS
(driver view)
RAMPS
A V+ Power supply 24 VDC for solenoid power stage and driver logic Input - power supply
B V0 Power supply 0 VDC for solenoid power stage and driver logic Gnd - power supply
AGND Ground - signal zero for MONITOR signal Gnd - analog signal
C (1)
ENABLE Enable (24 VDC) or disable (0 VDC) the driver (for /Q option) Input - on/off signal
D INPUT+ Reference analog differential input: ±10 VDC maximum range (4 ÷ 20 mA for /I option)
Input - analog signal
E INPUT - Default setting for single solenoid valves: 0÷+10 VDC
F MONITOR Monitor analog output: 0÷+5 VDC maximum range; 1V=1A Output - analog signal
G EARTH Internally connected to the driver housing
Note: (1) with /Q option ENABLE signal replaces AGND on pin C; MONITOR signal is reffered to pin B.
A minimum time of 60ms to 160ms have be considered between the driver energizing with the 24 VDC power supply and when the valve is ready
to operate. During this time the current to the valve coils is switched to zero
F410
10 DIGITAL INTEGRAL DRIVERS -AES - MAIN FUNCTIONS AND ELECTRONIC CONNECTIONS
COMMUNICATION CONNECTOR
MAIN CONNECTOR 5 PIN 5 PIN
7 PIN - STANDARD PROFIBUS DP (-BP) CANopen (-BC)
(driver view)
SCALE BIAS
(driver view)
LINEARIZATION RAMPS
12 PIN - OPTION /Z
5 PIN
Serial (-PS)
(driver view)
(driver view)
10.1 ELECTRONIC CONNECTIONS - 7 & 12 PIN MAIN CONNECTORS
Standard /Z option
SIGNAL TECHNICAL SPECIFICATIONS NOTES
7pin 12pin
A 1 V+ Power supply 24 VDC for solenoid power stage (and for driver logic on 7 pin connection) Input - power supply
B 2 V0 Power supply 0 VDC for solenoid power stage (and for driver logic on 7 pin connection) Gnd - power supply
C
(option /Q) 3 ENABLE Enable (24 VDC) or disable (0 VDC) the driver Input - on/off signal
D 4 INPUT+ Reference analog input: ±10 VDC / ±20 mA maximum range software selectable
Default setting for single solenoid valves: 0÷+10 VDC, differential input Input - analog signal
E - INPUT - /Z and /W options: common mode INPUT+ referred to AGND
C 5 AGND Ground - signal zero for MONITOR signal (INPUT+ signal only for /Z and /W options) Gnd - analog signal
F 6 MONITOR Monitor analog output: 0÷+10 VDC maximum range; Default setting 1V = 1A Output - analog signal
- 7 NC do not connect
- 8 MONITOR 2 2nd monitor analog output: ±5 VDC maximum range (only for /W option)
- 9 VL+ Power supply 24 VDC for driver logic Input - power supply
- 10 VL0 Power supply 0 VDC for driver logic Gnd - power supply
- 11 FAULT Fault (0 VDC) or normal working (24 VDC) Output - on/off signal
G PE EARTH Internally connected to the driver housing
Note: A minimum time of 270 to 340 ms have be considered between the driver energizing with the 24VDC power supply and when the valve is ready
to operate. During this time the current to the valve coils is switched to zero.
10.2 ELECTRONIC CONNECTIONS - 5 PIN COMMUNICATION AND PRESSURE TRANSDUCER CONNECTORS
-PS Serial -BC CANopen -BP PROFIBUS DP /W pressure connector
PIN SIGNAL TECHNICAL SPECIF. SIGNAL TECHNICAL SPECIF. SIGNAL TECHNICAL SPECIF. SIGNAL TECHNICAL SPECIF.
1 NC do not connect CAN_SHLD Shield +5V for termination VT transducer power supply 24 VDC
2 NC do not connect NC do not connect LINE-A Bus line (high) TR transducer signal 0÷10 VDC
Signal zero data line DGND Signal
Data line and termination AGND Signal zero for power
3 RS_GND Signal zero data line CAN_GND zero supply and signal
4 RS_RX Receiving data line CAN_H Bus line (high) LINE-B Bus line (low) NC do not connect
5 RS_TX Transmitting data line CAN_L Bus line (low) SHIELD do not connect NC do not connect
11 SOFTWARE TOOLS
The driver configuration and parameters can be easily set with the Atos E-SW programming software, available in three different versions according to the
driver’s communication execution: E-SW-PS (Serial), E-SW-BC (CANopen) and E-SW-BP (PROFIBUS DP). Programming software E-SW-BC and E-SW-
BP, for BC and BP drivers, can be also used to modify the valve’s parameterization through the serial communication interface, without disconnecting the
valve from the machine’s bus line.
For a more detailed description of software interface, PC requirements, adapters, cables and terminators, please refer to technical table G500.
Programming software, must be ordered separately:
E-SW-* (mandatory - first supply) = Dvd including E-SW-* software installer and operator manuals; it allows the registration to Atos digital service
E-SW-*-N (optional - next supplies) = as above but not allowing the registration to Atos digital service
On first supply of the E-SW-* software, it is required to apply for the registration in the Atos download area: www.download.atos.com.
Once the registration is completed, the password will be sent by email.
The software remains active for 10 days from the installation date and then it stops until the user inputs his password.
With the password you can also download, in your personal area, the latest releases of the Atos software, manuals, drivers and configuration files.
Coil resistance R at 20°C 3 ÷ 3,3 Ω 2 ÷ 2,2 Ω 13 ÷ 13,4 Ω 3,8 ÷ 4,1 Ω 2,2 ÷ 2,4 Ω 12 ÷ 12,5 Ω
Max. solenoid current 2,2 A 2,75 A 1,2 A 2,6 A 3,25 A 1,2 A
Max. power 30 Watt 35 Watt
Protection degree (CEI EN-60529) IP65 for -A executions; IP67 for -AE and -AES
Duty factor Continuous rating (ED=100%)
13 DIAGRAMS (based on mineral oil ISO VG 46 at 50 °C)
1 = QVHZO-*
2 = QVKZOR-*
1 = QVHZO-*-06/3
QVHZO-*-06/12 3
2 = QVHZO-*-06/18
QVHZO-*-06/36 2
3 = QVHZO-*-06/45 5
4 = QVKZOR-*-10/65
5 = QVKZOR-*-10/90
4
1
F410
14 INSTALLATION DIMENSIONS [mm]
QVHZO-A*
QVHZO-A
ISO 4401: 2005
Mounting surface: 4401-03-02-0-05 (see tab. P005)
Fastening bolts: 4 socket head screws M5x50 class 12.9
Tightening torque = 8 Nm
Seals: 4 OR 108;
Diameter of ports A, B, P, T:
Ø 7,5 mm (max)
Mass: 2,3 kg
QVHZO-AE QVHZO-AES
Mass: 3,1 kg
Mass: 2,9 kg
훽 -PS communication interface, SP-ZH-5P connector
훾 -BP communication interface, SP-ZH-5P/BP connector (only for -AES)
쩸 Dotted line =12 poles connector SP-ZH-12P for option /Z 훿 -BC communication interface, SP-ZH-5P connector (only for -AES)
Pressure transducer interface (option /W), SP-ZM-5PM connector
QVKZOR-A*
QVKZOR-A
ISO 4401: 2005
Mounting surface: 4401-05-04-0-05 (see tab. P005)
Fastening bolts: 4 socket head screws M6x40 class 12.9
Tightening torque = 15 Nm
Seals: 5 OR 2050;
Diameter of ports A, B, P, T:
Ø 11,2 mm (max)
Mass: 3,8 kg
QVKZOR-AE QVKZOR-AES
SP-ZH-7P or SP-ZM-7P
SP-ZH-7P or SP-ZM-7P
훿
훾
쩸 쩸
훽
Mass: 4,6 kg
Mass: 4,4 kg
훽 -PS communication interface, SP-ZH-5P connector
훾 -BP communication interface, SP-ZH-5P/BP connector (only for -AES)
쩸 Dotted line =12 poles connector SP-ZH-12P for option /Z 훿 -BC communication interface, SP-ZH-5P connector (only for -AES)
Pressure transducer interface (option /W), SP-ZM-5PM connector
15 MODEL CODES OF POWER SUPPLY AND COMMUNICATION CONNECTORS (to be ordered separately)
11/11