The D132-GA is a direct acting, total isolation solenoid valve designed for liquid and gaseous fluids, featuring a body made of PPS and sealing options of EPDM or FPM. It has a maximum pressure of 2 bar, operates at fluid temperatures from -10°C to +90°C, and has a quick opening and closing time of 30ms. The valve is suitable for various voltages and can be installed in any position, with specific maintenance and installation guidelines provided.

Uploaded by

Diego Granados
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views2 pages

D132-GA-EN

The D132-GA is a direct acting, total isolation solenoid valve designed for liquid and gaseous fluids, featuring a body made of PPS and sealing options of EPDM or FPM. It has a maximum pressure of 2 bar, operates at fluid temperatures from -10°C to +90°C, and has a quick opening and closing time of 30ms. The valve is suitable for various voltages and can be installed in any position, with specific maintenance and installation guidelines provided.

Uploaded by

Diego Granados
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SOLENOID VALVE – DRY TECH

D132-GA
TOTAL INSULATION DRY G ½ VALVE

   
GENERAL FEATURES MATERIALS IN CONTACT WITH FLUID
Direct acting, total isolation solenoid valve: the actuator is totally Body PPS (see notes)
isolated from the fluid so that the wetted parts are just the body Sealing EPDM or FPM
and the diaphragm. 
Possibility of disassembling for inspection. COIL
Core duly coated by PTFE (polytetrafluoroethylene) based self Continuous duty ED 100%
lubricating material. Encapsulation material PET (polyethylene) fiberglass reinforced
Suitable to shut off liquid and gaseous fluids (verify the Coil insulation class F (140°C)
compatibility of fluid with materials in contact). Ambient temperature -10°C +60°C
 Electric connections DIN 46340 – 3 poles connectors (EN175301-803)
TECHNICAL FEATURES Protection degree IP 65 (EN 60529) with plug connector
Maximum allowable pressure (PS) 2 bar Voltages DC 12-24V (+10% -5%)
Opening time 30ms AC 24V/50Hz - 110V/50Hz (120V/60Hz) - 230V/50Hz
Closing time 30ms (+10% -15%)
Fluid temperature -10°C +90°C (Other voltages and frequencies on request).
Max viscosity 5°E ( 37 cStokes or mm2/s)
BODY COLOR ALL BLACK OR NATURAL WITHE

Differential pressure (bar)


Series and type Power absorption
Orifice Δp max
Port size Kv Weight
size Sealings Notes
ISO 228 (m3/h) (kg)
(mm) Δp min Gases Liquids AC (VA)
DC
Valve Coil
(W)
AC DC AC DC Inrush Holding

D132-GA EPDM
G 1/2 9 0 1,6 0,25 1,6 0,25 1,6 Z13 44 24 13 - 0,530
D132-GA FPM

 
NOTES
- Sealings : EPDM = Ethylene-propylene elastomer FPM = Fluoro-carbon elastomer
1402/1706

- Body: PPS (Polyphenylene-sulfide) fibreglass reinforced, WRAS/KTW and NSF approval

- BUSSERO (MI) – Italy – www.granados.com.ar


D132-GA
 
SPARE PARTS

Kit description Kit P.N. Consisting of:

Body kit G2986604 Upper body pos.6


Lower body pos.5

Core kit G2992801 Core return spring pos.2


Core pos.3

Lever seal 3037305R Lever seal pos.4


3037301R

THE VALIDITY OF REPORTED DATA IS REFERRED TO THE DATE OF ISSUE. POSSIBLE UPDATES ARE AVAILABLE ON REQUEST.
Cover 2985703R Cover pos.8

Kit guide assembly G31523 Guide assembly pos.7


Coil clip

Coil Z13 Coil pos. 1

 
INSTALLATION
- Solenoid valve can be mounted in any position; vertical with coil upwards preferred.
- In case of disassembling for usual maintenance, the fixing screws have to be tightened at 1,5 Nm max torque.
- Maximum driving torque of the pipe fittings for thread connections = 15Nm.

BUSSERO (MI) – Italy – www.granados.com.ar