RoHS SS-304
RoHS SS-304
SUBMITTED SAMPLE
Page 1 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
TESTED COMPONENT:
[1] 2410216000 (THICK-0.60, SIZE 60*150); HEAT NO 40208B28
REMARK: PBB/PBDE & PHTHALATE PERFORMED ON METAL PART AS PER APPLICANT REQUEST.
NOTE:
1. Statement of conformity is based on the simple acceptance rule without using measurement
uncertainty.
2. In this report results relate only to the item tested.
3. Laboratory reports the final test results in test report. Any additional information, if required will be
provided on request.
4. Samples received in good condition.
5. Testing has been performed as per the applicant’s request.
6. Sampling is not done by Laboratory.
AUTHORIZED BY
FOR INTERTEK INDIA PVT. LTD
SUDHANSHU KUMAR
LAB MANAGER – HARDLINE AND TOYS
Page 2 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
TEST CONDUCTED
Page 3 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
Result
Test Item Unit Test Method RL
(1)
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB) ppm ND 5
Dibrominated Biphenyls
ppm ND 5
(DiBB)
Tribrominated Biphenyls
ppm With reference to IEC 62321-6: ND 5
(TriBB)
Tetrabrominated Biphenyls (TetraBB) ppm 2015, by solvent extraction ND 5
and determined by GC-MS and
Pentabrominated Biphenyls (PentaBB) ppm ND 5
further HPLC-DAD
Hexabrominated Biphenyls (HexaBB) ppm ND 5
confirmation when necessary.
Heptabrominated Biphenyls (HeptaBB) ppm ND 5
Octabrominated Biphenyls (OctaBB) ppm ND 5
Nonabrominated Biphenyls (NonaBB) ppm ND 5
Decabrominated Biphenyl (DecaBB) ppm ND 5
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers
ppm ND 5
(MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE) ppm ND 5
Tribrominated Diphenyl Ethers
ppm ND 5
(TriBDE)
Tetrabrominated Diphenyl Ethers
ppm ND 5
(TetraBDE)
Pentabrominated Diphenyl Ethers With reference to IEC 62321-6:
ppm ND 5
(PentaBDE) 2015, by solvent extraction
Hexabrominated Diphenyl Ethers and determined by GC-MS and
ppm ND 5
(HexaBDE) further HPLC-DAD
Heptabrominated Diphenyl Ethers confirmation when necessary.
ppm ND 5
(HeptaBDE)
Octabrominated Diphenyl Ethers
ppm ND 5
(OctaBDE)
Nonabrominated Diphenyl Ethers
ppm ND 5
(NonaBDE)
Decabrominated Diphenyl Ether
ppm ND 5
(DecaBDE)
Page 4 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
Result
Test Item Unit Test Method RL
(1)
Phthalates
Di(2-ethylhexyl) Phthalate (DEHP) ppm ND 50
Dibutyl Phthalate (DBP) ppm With reference to IEC 62321- ND 50
8:2017, by solvent extraction
Benzyl Butyl Phthalate (BBP) ppm and determined by GC-MS. ND 50
Di isobutyl Phthalate (DIBP) ppm ND 50
REMARKS: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
RL = Reporting limit, quantitation limit of analyte in sample
RoHS Limit
Restricted Substances Limits
Cadmium (Cd) content 0.01% (100ppm)
1000 ppm (40000 ppm FOR BRASS/COPPER MATERIAL)
Lead (Pb) content (3500 ppm FOR STEEL)
(4000 ppm FOR ALUMINIUM)
Mercury (Hg) content 0.1% (1000ppm)
Chromium VI (Cr6+) content 0.1% (1000ppm)
Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)
Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000ppm)
Di(2-ethylhexyl) Phthalate (DEHP) 0.1% (1000ppm)
Dibutyl Phthalate (DBP) 0.1% (1000ppm)
Benzyl Butyl Phthalate (BBP) 0.1% (1000ppm)
Di isobutyl Phthalate (DIBP) 0.1% (1000ppm)
The limits were quoted from Annex II of 2011/65/EU and Amendment (EU) 2015/863 for homogeneous material.
Page 5 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
Measurement Flowchart:
Sampling
Polymers /
Metal Electronics
Analyzed by UV-VIS
Page 6 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.
ULR - TC566325425000630F
REMARKS:
*1: List of Appropriate Acid:
Material Acid Added for Digestion
Polymers HNO3,HCl,HF,H2O2,H3BO3
Metals HNO3,HCl,HF
Electronics HNO3,HCl,H2O2,HBF4
*2: If sample solution is significantly more intense than 0.13 μg/cm2 equivalent comparison standard, Chromium VI
would be determined as detected, the result of visual observation is positive.
Measurement Flowchart:
Sampling
By solvent extraction
Analyzed by GC-MS
************************************************************************************************************************
# END OF TEST REPORT #
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not
intended to be a recommendation for any particular course of action Intertek does not accept a duty of care or any other
responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is
expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no
warranties or representations either express or implied with respect to this report save as provided for in those terms and
conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for
any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our
gross negligence or wilful misconduct.
Page 7 of 7
Intertek India Pvt. Ltd. 290, Udyog Vihar, Phase-II, Gurgaon, Haryana –122016. Tel: 0124-4503400,
Registered Office : E-20, Block B-1, Mohan Fax: 0124-4303592
Co-Operative Industrial Area, Mathura Road, www.Intertek.com
New Delhi -110044.