N4D8B08 8-Channel RS485 IO Input and Output Controller Manual

The N4D8B08 8CH RS485 IO input and output controller manual provides specifications and features for a relay controller that operates on DC 12V or 24V, with various commands and MODBUS support. It includes details on power consumption, input/output configurations, and the ability to control up to 64 devices in parallel. Additionally, it outlines wiring diagrams for both DC and AC control circuits for various applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views

N4D8B08 8-Channel RS485 IO Input and Output Controller Manual

The N4D8B08 8CH RS485 IO input and output controller manual provides specifications and features for a relay controller that operates on DC 12V or 24V, with various commands and MODBUS support. It includes details on power consumption, input/output configurations, and the ability to control up to 64 devices in parallel. Additionally, it outlines wiring diagrams for both DC and AC control circuits for various applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 6

N4D8B08 8CH RS485 IO input and output controller Manual

 2CH RS485 Relay Serial HyperTerminal Enter:

http://v.youku.com/v_show/id_XMTM0ODY4NzkxMg==.html
 2CH RS485 Relay Modbus Poll Enter(Usage 2-channel and 8-channel is the same):

http://v.youku.com/v_show/id_XMTM0ODY4OTg5Mg==.html

Features:
1: DC 12V (12V Version), DC 24V (24V Version)
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays
open 95MA,4 relays open 122MA,5 relays open 149MA,6 relays open 174MA, 7 relays open
198MA,8 relays open 225MA
3 8 photoelectric isolation Input ports (NPN low level active ), the input and output relationship
can be set to associated (default) and non-associated through commands.
4: "open" "close" "Momentary" "Self-locking" "Interlock" "Delay" 6 Commands
5: MODBUS RTU command, Support 03 06 16 function code
6: Under the "Delay" command ,the maximum delay is 255 seconds;
7 MODBUS commands can be made serial HyperTerminal (serial assistant) OR "Modbus Poll"
Enter;
8 Under the MODBUS command mode, it can support up to 64 devices in parallel
9 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800
9600 19200BPS
10 Size: 136 * 72 * 20mm(Only PCB Board);140 * 88* 42mm(with Din Rail Box)
11 Weight: 134g(Only PCB Board);223g(with Din Rail Box)
12 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 136 mm PCB boards
Net weight: 99g
Installation: DIN35 and C45 rail

Glossary:
NO : Relay normally open contact
COM : Relay common contact
NC : Relay normally closed contact
Open : NO connection COM, NC disconnect COM
Close : NO disconnect COM, NC connection COM
Momentary : Enter the Momentary command, the Rreceiver Relay is Open, delay of 0.5 seconds
after, Relay is Close;
Toggle : Enter the Toggle command, the Rreceiver Relay is Open, Enter the Toggle command
again, Relay is Close;

Latched : Enter the Channel 1 Latched command, the receiver Channel 1 is Open, the Channel 2 is
Close.
Enter the Channel 2 Latched command the receiver Channel 2 is Open, the Channel 1 is Close.
Enter the Channel 3 Latched command the receiver Channel 1 is Close, the Channel 2 is Close.

Delay : Enter the Delay command, the Rreceiver Relay is Open, delay of 0-9999 seconds(MODBUS
command is 0-255 seconds )after, Relay is Close;
During the delay, Eter the Close command, immediately close the relay

Slave ID: A0-A5 is the slave ID, you can choose 64 different slave ID.
Under the MODBUS command mode,the slave ID must be correct
command Description, Please refer to "N4D8B08 8-channel RS485 IO input and
output controller commamd"
Typical applications:

1 The dial switch (slave address) is invalid and can only control one module at a time.
MODBUS command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control
(need to manually add the CRC), Modbus Poll software control (software automatically add the
CRC), PLC or MCU process control

Wiring Diagram:

1 DC 12V control circuit,Wiring diagram below. "LOAD" may be camera,LED lights, fans, motors
and other DC 12V equipment
2 DC 1-110VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need
another DC 12V power supply). "LOAD" may be LED lights, fans, motors Lights, fluorescent lights,
solar water heaters and other DC AC equipment