0% found this document useful (0 votes)
6 views

1769-ECR

This document provides installation instructions for Compact I/O End Caps/Terminators, including specifications, environmental considerations, and safety certifications. It details the necessary precautions for use in hazardous locations and outlines the dimensions and current draw for various models. Additional resources and support information are also included for users seeking further assistance.

Uploaded by

Orion Valground
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

1769-ECR

This document provides installation instructions for Compact I/O End Caps/Terminators, including specifications, environmental considerations, and safety certifications. It details the necessary precautions for use in hazardous locations and outlines the dimensions and current draw for various models. Additional resources and support information are also included for users seeking further assistance.

Uploaded by

Orion Valground
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Installation Instructions

Original Instructions

Compact I/O End Caps/Terminators


Catalog Numbers 1769-ECL, 1769-ECLK, 1769-ECR, 1769-ECRK

Topic Page
Summary of Changes 2
1769-ECL Left End Cap and 1769-ECLK Left End Cap 5
1769-ECL and 1769-ECLK Dimensions 5
1769-ECR and 1769-ECRK Right End Cap 6
1769-ECR and 1769-ECRK Dimensions 7
Specifications 8
Environmental Specifications 8
Certifications 9
Additional Resources 9

About the End Caps/Terminators


The 1769 Compact I/O™ controllers, such as the 1769-L32E, require end caps. A 1769-ECR
right end cap, a 1769-ECRK right end cap, a 1769-ECLK left end cap, or a1769-ECL left end
cap terminates the end of the communication bus. Use this guide to install either end cap.
Compact I/O End Caps/Terminators

Summary of Changes
This publication contains new and updated information as indicated in the following table.

Topic Page
Updated certification and warning information. Throughout

North American Hazardous Location Approval

The following information applies when operating Informations sur l’utilisation de cet équipement en
this equipment in hazardous locations. environnements dangereux.

Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for Les produits marqués “CL I, DIV 2, GP A, B, C, D” ne conviennent
qu'à une utilisation en environnements de Classe I Division 2
use in Class I Division 2 Groups A, B, C, D, Hazardous Locations
and nonhazardous locations only. Each product is supplied Groupes A, B, C, D dangereux et non dangereux. Chaque produit
est livré avec des marquages sur sa plaque d'identification qui
with markings on the rating nameplate indicating the indiquent le code de température pour les environnements
hazardous location temperature code. When combining
products within a system, the most adverse temperature dangereux. Lorsque plusieurs produits sont combinés dans un
système, le code de température le plus défavorable (code de
code (lowest “T” number) may be used to help determine température le plus faible) peut être utilisé pour déterminer le
the overall temperature code of the system. Combinations of
equipment in your system are subject to investigation by the code de température global du système. Les combinaisons
d'équipements dans le système sont sujettes à inspection par les
local Authority Having Jurisdiction at the time of installation. autorités locales qualifiées au moment de l'installation.
WARNING: AVERTISSEMENT:
Explosion Hazard – Risque d’Explosion –
• Do not disconnect equipment • Couper le courant ou s'assurer que
unless power has been removed or l'environnement est classé non
the area is known to be dangereux avant de débrancher
nonhazardous. l'équipement.
• Do not disconnect connections to • Couper le courant ou s'assurer que
this equipment unless power has l'environnement est classé non
been removed or the area is known dangereux avant de débrancher les
to be nonhazardous. Secure any connecteurs. Fixer tous les connecteurs
external connections that mate to externes reliés à cet équipement à l'aide
this equipment by using screws, de vis, loquets coulissants, connecteurs
sliding latches, threaded filetés ou autres moyens fournis avec ce
connectors, or other means produit.
provided with this product. • La substitution de composants peut
• Substitution of components may rendre cet équipement inadapté à une
impair suitability for Class I, utilisation en environnement de Classe
Division 2. I, Division 2.
• If this product contains batteries, • S'assurer que l'environnement est classé
they must only be changed in an non dangereux avant de changer les
area known to be nonhazardous. piles.

2 Rockwell Automation Publication 1769-IN015F-EN-P - July 2020


Compact I/O End Caps/Terminators

Environment and Enclosure


ATTENTION:
This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage
Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters
(6562 ft) without derating.
This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR
Publication 11. Without appropriate precautions, there may be potential difficulties ensuring
electromagnetic compatibility in other environments due to conducted as well as radiated
disturbance.
This equipment is supplied as open-type equipment. It must be mounted within an enclosure
that is suitably designed for those specific environmental conditions that will be present and
appropriately designed to help prevent personal injury resulting from accessibility to live parts.
The enclosure must have suitable flame-retardant properties to help prevent or minimize the
spread of flame, complying with a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-
metallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent
sections of this publication may contain additional information regarding specific enclosure type
ratings that are required to comply with certain product safety certifications.
In addition to this publication, see:
• Industrial Automation Wiring and Grounding Guidelines, for additional installation
requirements, Allen-Bradley publication 1770-4.1.
• NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of
the degrees of protection provided by different types of enclosure.

Prevent Electrostatic Discharge


ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal
damage and affect normal operation. Follow these guidelines when you handle this equipment:
• Touch a grounded object to discharge potential static.
• Wear an approved grounding wriststrap.
• Do not touch connectors or pins on component boards.
• Do not touch circuit components inside the equipment.
• Use a static-safe workstation, if available.
• Store the equipment in appropriate static-safe packaging when not in use.

Rockwell Automation Publication 1769-IN015F-EN-P - July 2020 3


Compact I/O End Caps/Terminators

European Hazardous Location Approval—1769-ECR and 1769-ECRK


The following applies to products marked , II 3 G. Such modules:
• Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the
design and construction of such equipment given in Annex II to Directive 2014/34/EU. See the EC Declaration of Conformity at
http://www.rockwellautomation.com/products/certification for details.
• The type of protection used is ‘Ex nA IIC T4 Gc’ according to EN 60079-15.
• Comply to Standards: EN 60079-0:2012+A11:2013, EN 60079-15:2010, reference certificate number DEMKO12ATEX1116807X.
• Modules are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air or dust mixtures are
unlikely to occur, or are likely to occur only infrequently and for short periods. Such locations correspond to Zone 2 classification
according to ATEX directive 2014/34/EU.

IEC Hazardous Location Approval—1769-ECR and 1769-ECRK


The following applies to products with IECEx certification. Such modules:
• Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are
likely to occur only infrequently and for short periods. Such locations correspond to Zone 2 classification to IEC 60079-0.
• The type of protection is ‘Ex nA IIC T4 Gc’ according to IEC 60079-15.
• Comply to Standards: IEC 60079-0:6th edition, IEC-60079-15:4th Edition, reference IECEx certificate number IECEx UL 20.0078X.

WARNING: Special Conditions for Safe Use


• Equipment is not resistant to sunlight or other sources of UV radiation.
• Equipment shall be mounted in an ATEX/IECEx Zone 2 certified enclosure with a minimum
ingress protection rating of at least IP54 (as defined in EN/IEC 60529) and used in an
environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when
applied in Zone 2 environments. The enclosure must be accessible only by the use of a tool.
• Equipment shall be used within its specified ratings defined by Rockwell Automation.
• Provision shall be made to prevent the rated voltage from being exceeded by transient
disturbances of more than 140% of the rated voltage when applied in Zone 2 environments.
• Equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes.
• Do not disconnect equipment unless power has been removed or the area is known to
be nonhazardous.

4 Rockwell Automation Publication 1769-IN015F-EN-P - July 2020


Compact I/O End Caps/Terminators

1769-ECR and 1769-ECRK Right End Cap

2 3

6 Rockwell Automation Publication 1769-IN015F-EN-P - July 2020


Compact I/O End Caps/Terminators

1769-ECR and 1769-ECRK Dimensions


32 mm
(1.26 in.)
85 mm
18 mm (3.35 in.)
(0.71 in.)

118 mm
(4.65 in.)

Rockwell Automation Publication 1769-IN015F-EN-P - July 2020 7


Compact I/O End Caps/Terminators

Specifications
Attribute 1769-ECL, 1769-ECLK 1769-ECR, 1769-ECRK
Current draw at 5.1V DC 5 mA
Current draw at 24V DC 0 mA
Operating altitude 2000 m (6562 ft)
North American temp code T3C
IEC temp code — T4
Shipping weight, approx 130 g (0.286 lb)
Enclosure type rating None (open style)

Environmental Specifications
Attribute 1769-ECL, 1769-ECLK 1769-ECR, 1769-ECRK
Operating temperature
IEC 60068-2-1 (Test Ad, Operating Cold)
0 > Ta > 60 °C (32 > Ta > 140 °F)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Nonoperating temperature
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating
Cold)
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating -40 > Ta > 85 °C (-40 > Ta > 185 °F)
Dry Heat)
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating
Thermal Shock)
Relative humidity 5…95% noncondensing
Vibration
5 g, 10…500 Hz
IEC 60068-2-6 (Test Fc, Operating)
Operating shock
DIN rail mount: 20 g; Panel mount: 30 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Nonoperating shock
DIN rail mount: 30 g; Panel mount: 40 g
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
Emissions
Group 1, Class A
CISPR 11
ESD immunity
8 kV air discharges
IEC 61000-4-2
10V/m with 1 kHz sine-wave 80% AM from 80…2700 MHz
Radiated RF immunity
10V/m with 200 Hz 50%Pulse 100% AM at 900 MHz
IEC 61000-4-3
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz

8 Rockwell Automation Publication 1769-IN015F-EN-P - July 2020


Compact I/O End Caps/Terminators

Certifications
Certifications(1) 1769-ECL, 1769-ECLK 1769-ECR, 1769-ECRK
UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, certified for U.S. and
c-UL-us
Canada. See UL File E334470
European Union 2014/30/EU EMC Directive, compliant with:
CE EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
Australian Radiocommunications Act, compliant with:
RCM
AS/NZS CISPR 11; Industrial Emissions
European Union 2014/30/EU ATEX Directive,
compliant with:
EN 60079-15; Potentially Explosive
Atmospheres, Protection ‘n’
(II 3 G Ex nA IIC T4 Gc)
Ex — EN 60079-0; General Requirements (Zone 2)
IECEx; Correspond to Zone 2 classification to
IEC 60079-0.The type of protection is ‘Ex nA
IIC T4 Gc’ according to IEC 60079-15.
Reference IECEx certificate number IECEx
UL 20.0078X.
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Additional Resources
These documents contain additional information concerning related products from Rockwell
Automation.

Resource Description
Provides information on how to install any 1769 Compact I/O
Compact I/O Modules, publication 1769-IN088A module.
1769 Compact I/O Modules Specifications,
Provides technical data for 1769 Compact I/O modules.
publication 1769-TD006
Industrial Automation Wiring and Grounding Guidelines, Provides general guidelines for installing a Rockwell
publication 1770-4.1 Automation industrial system.
Product Certifications website,
Provides declarations of conformity, certificates, and other
http://www.rockwellautomation.com/global/certification/ certification details.
overview.page

You can view or download publications at http://www.rockwellautomation.com/global/


literature-library/overview.page. To order paper copies of technical documentation, contact your
local Allen-Bradley distributor or Rockwell Automation sales representative.

Rockwell Automation Publication 1769-IN015F-EN-P - July 2020 9


Rockwell Automation Support
Use the following resources to access support information.

Technical Support Knowledgebase Articles, How-to Videos, FAQs, Chat, User https://
Center Forums, and Product Notification Updates. rockwellautomation.custhelp.com/

Local Technical
http://www.rockwellautomation.com/
Support Phone Locate the phone number for your country. global/support/get-support-now.page
Numbers
Find the Direct Dial Code for your product. Use the code to http://www.rockwellautomation.com/
Direct Dial Codes
route your call directly to a technical support engineer. global/support/direct-dial.page

Literature Library Installation Instructions, Manuals, Brochures, and http://www.rockwellautomation.com/


Technical Data. global/literature-library/overview.page
Product
Compatibility and Get help determining how products interact, check http://www.rockwellautomation.com/
Download Center features and capabilities, and find associated firmware. global/support/pcdc.page
(PCDC)

Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions
on how to improve this document, complete the How Are We Doing? form at http://
literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Waste Electrical and Electronic Equipment (WEEE)

At the end of life, this equipment should be collected separately from any unsorted
municipal waste.

Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.

Rockwell Automation maintains current product environmental information on its website at


http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.

Allen-Bradley, Compact I/O, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 1769-IN015F-EN-P - July 2020 PN-595354


Supersedes Publication 1769-IN015E-EN-P - July 2019 Copyright © 2020 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

You might also like