R2B-P2-204-02-H-HD-10051 - Rev.00 - WASH WATER PUMPS (GA-51008AB)
R2B-P2-204-02-H-HD-10051 - Rev.00 - WASH WATER PUMPS (GA-51008AB)
MECHANICAL DATASHEET
WASH WATER PUMPS
(GA-51008A/B)
BETWEEN
AND
This document, including any patented or patentable features, embodies confidential information of Samsung Ingeniería Manzanillo, S.A. de C.V.
and its use is conditioned upon the user’s agreement not to reproduce the document in whole or in part. Nor the material described thereon nor to
use the document for any purpose other than specifically permitted in writing by Samsung Ingeniería Manzanillo, S.A. de. C.V.
PHASE II OF REFINERY IN DOS
BOCAS (HDN, HDDI, HDTGO, REF)
Page 2 / 8
Doc. TITLE MECHANICAL DATASHEET Rev. 00
Contract Doc. No. R2B-P2-204-02-H-HD-10051 Contract No. PTI-ID-O-003-3-2020
Contractor
Contractor Doc. No. SO6625-EJ2E-TDS-P2204049 SO6625
Job. No.
REVISION HISTORY
* Note:
This page records all revisions on the procedures.
CENTRIFUGAL PUMP DATA SHEET
(GA-51008A/B)
6 LIQUID CHARACTERISTICS
7 Units Maximum Minimum Note SERVICE : CONTINUOUS
8 LIQUID TYPE OR NAME : Skimmed Water or BFW Max & min values refer • IF INTERMITTENT NO. OF STARTS : 2
(1)
9 VAPOR PRESSURE : kg/cm² a 1.476 only to the property PUMPS OPERATE IN:
10 RELATIVE DENSITY(1,8) : - 0.915 listed CORROSION DUE TO : (6.12.1.9)
11 SPECIFIC HEAT : kcal/(kg-K) EROSION DUE TO : (6.12.1.9)
12 VISCOSITY(1,8) : cP 0.311 H2S CONCENTRATION (ppm) : (6.12.1.12)
1 CONSTRUCTION Rev
2 API PUMP TYPE: BB5 [Based on API 610 definitions] CASING MOUNTING: CENTERLINE
3 CASING TYPE: (6.3.10) DIFFUSER
4 NOZZLE CONNECTIONS: (6.5.5) OH3 BACKPULLOUT LIFTING DEVICE REQD. (9.1.2.6)
6 SUCTION 3" RTJ 900# TOP MAWP : (6.3.6) 98.9 kg/cm2g @ 150 °C
27 NUMBER PER THRUST BEARING INACTIVE SIDE MANIFOLD PIPING FOR PURCHASER CONNECTION (7.5.1.6)
28 TEMP. GAUGES (WITH THERMOWELLS) (9.1.3.6) VENT N/A
29 PRESSURE GAUGE TYPE DRAIN YES
30 Remarks COOLING WATER YES
31 TAG ALL ORIFICES (7.5.2.4) YES
32 SOCKET WELD CONN ON SEAL GLAND (7.5.2.8) NO
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
29 (Including Hydro test, Balancing test, Mechanical running test, Performance test)
30 R2B-P2-204-03-H-PND-MGA135-01014_NDE PROCEDURE
31 R2B-P2-204-03-H-IPM-MGA135-01015_PMI PROCEDURE
32 R2B-P2-204-03-H-PSL-MGA135-01019_WPS & PQR
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
1 Remark: Rev
2 1) Operation temperature 110°C.
3 2) Available NPSH is 38.912 m (127.7 ft).
4 3) Maximum operation temperature 120°C
5 4) Pump materials according to table H-1 of the ANSI / API STD 610 ed. 11 (ISO 13709-2009). Applies NACE STD MR 0103-2012
6 and MR 0175 / ISO 15156 Part 1-2-3 edition 2.
7 5) Deleted.
8 6) Pump drivers are premium efficiency electric motors.
9 7) Deleted.
10 8) Conditions indicated are based on the BME SOR, the Design case shown in the supplementary information.
11 9) Deleted.
12 10) Allowable pressure drop for cooling water system : 1 kg/cm2.
13 11) Design temperature : 150°C
14 12) Deleted.
15 13) Seal Plan : 23/61
16
17 General Remarks:
18 a) Pump and auxiliary system must be design according to ET-050-PEMEX-2019 ANSI /API STD 610 Ed. 11 (ISO 1379-2009).
19 b) Pump equipment paint must comply with ET-053-PEMEX-2019 and ET-009-PEMEX-2019.
20 c) Electric motors must be designed according to ET-048-PEMEX-2019, ET-095-PEMEX-2019 and ANSI/API STD 541.
21 d) Mechanical seal must be designed according to ANSI / API STD 682 4th.
22 e) Lubrication system must be designed according to ANSI / API STD 614, Ed. 5 ISO 10438-2007.
23 f) The pumps will be driven by electric motors.
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62