PM-2000M
PM-2000M
PAT
PM - 2000M
Patient Monitors
January 2018 | PM-2000M Rev. 02
Patient Monitor
Model Accurate Readings and Optimized Performance
The PM-2000M is a full modular monitor intended to be used for monitoring, storing, reviewing, and
PM-2000M recording patients data during treatment in the hospital environment. It offers plug-and-play modules
and an extensive modular rack that can be used in a wide range of parameters simultaneously, adapting
from critical cares to anesthesia monitoring, with additional monitoring capabilities including ICG, RM
and BIS.
2
PM-2000M
Patient Monitor
PM - 2000TM Patient Monitor / Module
Patient Modular Monitor PM- 2000TM is lightweight and compact so you can easily carry it along
with the babe during medical examinations and treatments .
Patient Modular Monitor
High Resolution Color TFT LCD Display Quiet operation and also eliminates the accumulation of dust inside the
Numerical and waveform information unit which is essential for the Intensive Care Unit.
Full touch-screen display, intuitive operation by clicking With the PM-2000TM you can have a close look at the new born’s
parameter or waveform Mounting Solution
Modular monitor cardiovascular and respiratory system by using the OxyCRG screen.
Pacemaker detection
Nurse Call function
Defibrillation protection and synchronization
Settings
OxyCRG, assessment of respiration and circulation for
neonates 2-channel temperature monitoring.
Extended Full-disclosure trend information ECG algorithm optimized for arrhythmia detection, pacemaker
Comprehensive alarm system
Multifunctional Rotary Knob detection, and measurement of heart rate.
Multiple Measurements Module ECG, Resp., SpO2, Optional 2-channel invasive blood pressure function with
NIBP, & Temp. overlapping waveforms.
Functional Arterial Oxygen Saturation module (V-
SpO2) (optional) NIBP algorithm optimized for cardiac patients, patients hypertensive
Respironics® Carbon Dioxide mainstream module and neonatal patients.
(CO2) (optional) SpO2 algorithm with resistance to movement and performance
Respironics® Carbon Dioxide sidestream module
(CO2) (optional) perfusion low resistance.
Carbon Dioxide sidestream module (CO2)(optional) Signal intensity (SI) measuring as an indicator of blood perfusion.
Anesthetic gas mainstream module (AG)(optional) 12 -lead algorithm diagnostic with 208 types of ECG in the ECG settings
Anesthetic gas sidestream module (AG)(optional)
Cardiac Output module (CO)(optional) and12 optional derivations.
Invasive Blood Pressure module (IBP)(optional)
Omron Non-Invasive Blood Pressure module (NIBP)
(optional) Anesthetic Gas / O2 ( optional)
Bispectral Index module (BIS)(optional)
Impedance Cardiography (ICG)(optional) Mainstream (IRMA AX+)
Respiration mechanics (RM)(optional) CO2, N2O and anesthetic agent measurement and measuring probes .
Thermal Recorder (optional) Complete gas analysis system contained within sensor head.
Bidirectional communication with Monitoring Central Lower power consumption.
Station (CMS-2000)
Wi-Fi (optional)
HL7 communication via XML Files Sidestream (ISA AX+ / ISA OR+)
Barcode Scanner Support (optional) Low sample flow 50ml/min for all type of patients.
SD Card slot enables memory extension Extremely low power consumption and weight.
Bed-to-Bed viewing display (optional) Warm-up time 20 seconds before full performance.
Drug calculation and titration table
USB & serial Ports, VGA & analog outputs and RJ-45 Paramagnetic Oxygen
Built in rechargeable battery Fast response, totally linear.
Meet IEC 60601-1+A+A2 & IEC 60601-2+A High stability and accuracy.
Safety Standards. Long operational life.
Low maintenance requirements.
2 YEARS
warranty
4
Barcode Scanner Support
PM-2000M
Technical Specifications
Safety Standards Safety Standars IEC 60601-1+A1+A2; IEC 60601-2+A1; IEC 60601-1-8 (Alarm)
Physical Dimensions 17” 425mm (L) x 245mm (W) x 384mm (H) / 15” 384mm (L) x 213mm (W) x 320mm (H)
Specifications Weight 17 " Standard configuration 14kg / 15” 7,5 kg Includes TM module
Display Display 17” or 15” Color TFT LCD Touch-screen
Resolution Waveforms 1280X1024dpi
Displayed Selectable Up to 15
Interface Standard screen monitoring, Trend / Monitoring , Co - Display, bed to bed view (optional )
OxyCRG screen with dynamic view, calculation of drug dosages interface.
Environment Ambient Temperature -20 ºC ~ 55ºC (-4 ~ 131ºF)
Requirement Humidity 15% - 95% without condensation
Energy Supply Power Supply Internal 100-240V CA, 50/60HZ
Battery Battery Rechargeable Li -Ion 4200 mAh
Working Period 2 hours max. (2 batteries 4200mAh)
Recharging Time ≤350 minutes (4200 mAh)
Resp Method Impedance between RA- LL , RA -LA
Operation Mode Auto / Manual
Rr Measurement Range Adult: 0-120rpm / Neonate-Pediatric: 0-150rpm
Resolution 1rPM
Apnea Alarm Threshold 10s, 15s, 20s (default), 25s, 30s, 35s, 40s
Alarm 3 levels of audible and visual alarm, Alarms events recallable
Band Width 0.2-2.5Hz (-3dB)
Sweep Speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
ECG Lead Type 3 - Leads: I, II , III / 5 - Leads: I, II , III, aVR , aVL, aVF, V / 12, Derivations : I, II , III ,
aVR, aVL, aVF, V1, V2, V3 , V4, V5 , V6
Gain Selection x0.125, x0.25, x0.5, x1, x2, x4
Sweep Speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
ECG Hr Range Adult:15-300bpm / / Pediatric-Neonate: 15-350bpm
Resolution & Accuracy ±1bpm or ±1%, whichever is greater
Filter Diagnosis mode: 0.05-150Hz / Monitoring mode: 0.5-40Hz / Surgical mode: 1-20Hz
St-Segment Detection Measurement range: -2.0mV ~ 2.0mV / Alarm range: -2.0mV ~ 2.0mV
Comes with St-segment Arrhythmia Analysis and Pacemaker detection
NIBP Method Oscillometric
Operations Modes Manual / Automatic/ Continuous
Auto Measurement 1/2/3/4/5/10/15/30/60/90/120/240/480 minutes.
Time Interval
Measurement Unit MmHg/kpa Selectable
Measurements Types Systolic, Diastolic, Mean
Pressure Range Adults Systolic: 40 - 270 mmHg / Diastolic: 10 - 215 mmHg / Mean: 20 - 235 mmHg
Pressure Range Pediatrics Systolic: 40 - 200 mmHg / Diastolic: 10 - 150 mmHg / Mean: 20 - 165 mmHg
Pressure Range Neonates Systolic: 40 - 135 mmHg / Diastolic: 10 - 100 mmHg / Mean: 20 - 110 mmHg
Resolution 1mmHg
Accuracy Max mean error ±5mmHg / Max standard deviation ±8mmHg
Alarm Systolic, Diastolic, Mean
Pr From PANI Measurement 40-240 bpm
Resolution 1 bpm
Accuracy ±3bpm or 3.5% whichever is greater
Comes with leak test and pressure auto calibration
6
2018 Advanced Instrumentations Inc., is a U.S.A registered company – All rights reserved.
All functionality, features, specifications and other product information provided in this document
including, but not limited to, the benefits, design, pricing, components, performance, availability, and
capabilities of the product are subject to change without notice or obligation. Advanced Instrumenta-
tions reserves the right to make changes to this document and the product described herein, at any
time, without obligation on Advanced Instrumentations to provide notification of such change. Actual
description and specification of the product in this document may be different. Images shown here
are for representational purpose only, actual may vary.
Advanced and Advanced Instrumentations trademarks and logos shown are property of
Advanced Instrumentations Inc.