0% found this document useful (0 votes)
7 views

Zenit Product Overview En

The document provides an overview of various submersible pump series designed for domestic, civil, and industrial applications, detailing their motor power ranges, efficiency, and specifications such as flow rates and maximum head. It highlights specific series like the Blue, Grey, and Uniqa, each tailored for different operational needs, including high performance and ATEX certification for hazardous environments. The pumps are characterized by features such as compact size, reliability, and advanced hydraulic designs to ensure optimal performance in various settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

Zenit Product Overview En

The document provides an overview of various submersible pump series designed for domestic, civil, and industrial applications, detailing their motor power ranges, efficiency, and specifications such as flow rates and maximum head. It highlights specific series like the Blue, Grey, and Uniqa, each tailored for different operational needs, including high performance and ATEX certification for hazardous environments. The pumps are characterized by features such as compact size, reliability, and advanced hydraulic designs to ensure optimal performance in various settings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

APPLICATIONS APPLICATIONS APPLICATIONS

DOMESTIC - RESIDENTIAL CIVIL - PROFESSIONAL - LIGHT INDUSTRIAL INDUSTRIAL - WATER TREATMENT


0.25 ÷ 1.5 KW 50/60 HZ 0.37 ÷ 18.5 KW 50/60 HZ 1.8 ÷ 355 KW HIGH EFFICIENCY 50/60 HZ

Grey
DG DR DGE DRE
High-performance,
compact stainless steel
Motor power ...... 0.37 ÷ 0.75 kW
Poles.................. 2
Motor power ...... 0.25 ÷ 0.75 kW
Poles.................. 2
E series and S series models
are ideal for installations in
Motor power ...... 0.37 ÷ 1.5 kW
Poles.................. 2
Motor power ...... 0.3 ÷ 1.5 kW
Poles.................. 2 series
submersible pumps Delivery port ...... GAS 1¼”-1½” V Delivery port ...... GAS 1¼”-1½” V small lifting stations where Delivery port ...... GAS 1½” ÷ 2” V Delivery port ...... GAS 1¼”- 2” V

steel for optimal service in


household installations
Free passage ..... max 40 mm
Max flow rate ..... 6.3 l/s
Max head ........... 10.0 m
Free passage ..... max 12 mm
Max flow rate ..... 335 l/m
Max head ........... 16.0 m
E/S compact size and excellent
reliability are required.
........................... GAS 2” DN50 H
Free passage ..... max 50 mm
Max flow rate ..... 11.6 l/s
........................... GAS 2” DN50 H
Free passage ..... max 15 mm
Max flow rate ..... 12.6 l/s
HIGH EFFICIENCY
and small civil plants. SUBMERSIBLE ELECTRIC
Impeller.............. vortex Impeller.............. open multi-channel Max head ........... 15.7 m Max head ........... 18.0 m
Impeller.............. vortex Impeller.............. open multi-channel PUMPS

The blue Series is intended DG Motor power ...... 0.3 ÷ 0.74 kW DR Motor power ...... 0.3 ÷ 0.74 kW GRE Motor power ...... 1.7 kW APE Motor power ...... 1.7 kW
New submersible pumps for drainage and lifting systems in civil and industrial applications with efficient and
mainly for domestic and Poles.................. 2 Poles.................. 2 Poles.................. 2 Poles.................. 2 UNIQA series pumps, designed for heavy-duty professional applications, are used in industrial and other wastewater treatment plants and
Delivery port ...... GAS 1½” V Delivery port ...... GAS 1¼” V Delivery port ...... GAS 2”-DN32 H Delivery port ...... GAS 2”-DN32 H reliable motors.
residential installations for lifting sewage and pumping wastewater which contains solids.
blue and provides compact size
and outstanding reliability.
Free passage ..... max 40 mm
Max flow rate ..... 7.7 l/s
Max head ........... 11.6m
Free passage ..... 7 mm
Max flow rate ..... 5.3 l/s
Max head ........... 14.0 m
Free passage ..... -
Max flow rate ..... 6.3 l/s
Max head ........... 27.3 m
Free passage ..... 7 mm
Max flow rate ..... 9.5 l/s
Max head ........... 24.9 m
Directly developed from the UNIQA know-how, the Grey Sereis project features completely redesigned hydraulics
and motors, to guarantee high performance, low consumption and outstanding versatility in the 0.37* to 18.5 kW Motors are designed with the aim of achieving the Premium (IE3) efficiency class according to the EN 60034-30 standard and guarantee
power range. high performance with low energy use. There are various types of hydraulics, to adapt perfectly to any type of application.
Impeller.............. vortex Impeller.............. open multi-channel Impeller.............. with grinder system Impeller.............. high head
*0,37 ÷ 1,5 Under development

The bluePRO Series DG Motor power ...... 0.37 ÷ 1.5 kW DR Motor power ...... 0.37 ÷ 1.5 kW GRS Motor power ...... 0.9 kW APS Motor power ...... 0.9 kW DGG Motor power ...... 0.37 ÷ 15 kW DRG Motor power ...... 0.37 ÷ 18.5 kW ZUG Motor power ...... 3 ÷ 45 kW
is intended for use in Poles.................. 2 Poles.................. 2 Poles.................. 2 Poles.................. 2 Poles.................. 2/4/6 Poles.................. 2/4/6 V Poles.................. 2/4
applications requiring high Delivery port ...... GAS 1½” - 2” V Delivery port ...... GAS 1½” - 2” V Delivery port ...... GAS 1½”-DN32 H Delivery port ...... GAS 1½”-DN32 H Delivery Port ...... GAS 1½”÷2½” V Delivery Port ...... GAS 1¼” ÷ GAS 2” V Delivery port ...... -
bluePRO performance or prolonged,
heavy-duty operation in
Free passage ..... max 50 mm
Max flow rate ..... 12.6 l/s
Free passage ..... max 15 mm
Max flow rate ..... 11.5 l/s
Free passage ..... -
Max flow rate ..... 4.3 l/s
Free passage ..... 7 mm
Max flow rate ..... 5.2 l/s Grey ........................... DN65÷DN150 H
Free Passage ..... max 120mm
........................... DN65 ÷ DN150 H
Free Passage ..... max 110 mm Uniqa ........................... DN65÷DN150 H
Free passage ..... max 125 mm
In DRY version models,
domestic and residential Max head ........... 15.3 m Max head ........... 17.0 m Max head ........... 20.4 m Max head ........... 20.3 m Max flow rate ..... 106 l/s Max flow rate ..... 205 l/s Max flow rate ..... 110.0 l/s
the motor is cooled
contexts. Impeller.............. vortex Impeller.............. open multi-channel Impeller.............. with grinder system Impeller.............. high head Max head ........... 24.5 m Max head ........... 50 m Max head ........... 75.0 m
by a water-glycol mix
Impeller.............. vortex Impeller.............. open multi-channel Impeller.............. vortex
circulating in a special
closed circuit.

GR Motor power ...... 0.74 ÷ 1.5 kW AP Motor power ...... 0.74 ÷ 1.5 kW The main feature of the O DGO Motor power ...... 0.37 ÷ 1.5 kW DRO Motor power ...... 0.37 ÷ 1.5 kW GRG Motor power ...... 0.75 ÷ 9 kW APG Motor power ...... 0.75 ÷ 9 kW ZUG Motor power ...... 1.8 ÷ 355 kW
Poles.................. 2 Poles.................. 2 series is the oil bath motor. Poles.................. 2/4 Poles.................. 2/4 Poles.................. 2/4 Poles.................. 2 OC Poles.................. 2/4/6/8/10/12
Delivery port ...... GAS 1½”-DN32 V Delivery port ...... GAS 1½”-DN32 V Together with its robust cast Delivery port ...... GAS 1½”÷ 2½” V Delivery port ...... GAS 1¼”÷ 2 V Delivery Port ...... GAS 1½”-2” H Delivery Port ...... GAS 1½”-2” H Delivery port ...... -
Free passage ..... -
Max flow rate ..... 5.6 l/s
Max head ........... 27 m
Free passage ..... max 6 mm
Max flow rate ..... 7.1 l/s
Max head ........... 26.6 m
O iron structure, it makes this
model particularly reliable
........................... GAS 2” DN50 H
........................... DN65/80 H
Free passage ..... max 80 mm
........................... GAS 2” DN50 H
Free passage ..... max 15 mm
Max flow rate ..... 13 l/s
........................... DN40÷DN100 H
Free Passage ..... -
Max flow rate ..... 8.4 l/s
........................... DN40-DN50 H
Free Passage ..... max 10 mm
Max flow rate ..... 10.5 l/s
........................... DN80÷DN600 H
Free passage ..... max 220 x 110 mm
Max flow rate ..... 1600.0 l/s
even in very tough operating
Impeller.............. with grinder system Impeller.............. high head conditions. Max flow rate ..... 19.0 l/s Max head ........... 18.4 m Max head ........... 53.5 m Max head ........... 52 m Max head ........... 100.0 m
Max head ........... 17.3 m Impeller.............. open multi-channel Impeller.............. with grinder system Impeller.............. high head Impeller.............. channel impeller with
Impeller.............. vortex anti-clogging and fouling system

The main feature of the F series DGF Motor power ...... 0.55 ÷ 1.5 kW DRF Motor power ...... 0.55 ÷ 1.5 kW ZUG Motor power ...... 4 ÷ 11 kW
models is ATEX certification, Poles.................. 2/4 Poles.................. 2/4 GR Poles.................. 2
zenit.com/steel which allows them to be used Delivery port ...... GAS 1½”÷2½” V Delivery port ...... GAS 1½”- 2” Delivery port ...... -

zenit.com/blue
F where a standard submersible
electric pump would be
........................... DN32÷DN80 H
Free passage ..... max 80 mm
Max flow rate ..... 16.7 l/s
........................... GAS1½” - 2” H
........................... DN32 ÷ DN100 H
Free passage ..... max 50 mm
........................... DN50÷G2” H
Free passage ..... -
Max flow rate ..... 8.0 l/s
unacceptable due to the
explosive nature of the liquids Max head ........... 17.5 m Max flow rate ..... 17.6 l/s Max head ........... 57.0 m
or environment. Impeller.............. vortex Max head ........... 16.5 m Impeller.............. with grinder system
zenit.com/bluePRO Impeller.............. open multi-channel

GRF Motor power ...... 1.1 ÷ 1.5 kW APF Motor power ...... 1.1 ÷ 1.5 kW
ZUG Motor power ...... 4 ÷ 11 kW
Poles.................. 2 Poles.................. 2 Motors HP Poles.................. 2
Delivery port ...... GAS 1½”-DN32 H Delivery port ...... GAS 1½”-DN32 H • from 0,37* to 18.5 kW operating at 50/60 Hz Delivery port ...... -
Free passage ..... - Free passage ..... max 7 mm • double mechanical seal in oil chamber ........................... DN50÷G2” H
Max flow rate ..... 6.4 l/s Max flow rate ..... 7.6 l/s Free passage ..... max 10 mm
Max head ........... 23 m Max head ........... 22.6 m • Cast iron structure Max flow rate ..... 11.0 l/s
Impeller.............. with grinder system Impeller.............. high head • Thermal protection devices incorporated Max head ........... 61.0 m
in stator Impeller.............. high head
• AISI 431 drive shaft
• Two silicon carbide mechanical seals in large
oil chamber
The DRX, DRY and DGX models DGX Motor power ...... 0.37 ÷ 1.5 kW DRX Motor power ...... 0.37 ÷ 1.5 kW • Discharge from DN32 to DN250 ZUG Motor power ...... 3 ÷ 45 kW
are constructed in CF8_M (AISI Poles.................. 2/4 Poles.................. 2 • Large free passage CP Poles.................. 2/4/6
SPECIAL 316) stainless steel and have
multi-channel open impeller
Delivery port ...... GAS 2” V
........................... DN65-DN80 H
Delivery port ...... GAS 1¼”-2” V
Free passage ..... max 15 mm
Delivery port ...... -
........................... DN80÷DN250

ALLOY suitable for strained liquids


(DRX) or for liquids with solids
Free passage ..... max 60 mm
Max flow rate ..... 18.4 l/s
Max flow rate ..... 12.5 l/s
Max head ........... 17.8 m
Free passage ..... -
Max flow rate ..... 244.0 l/s
NAVIGATOR SUITE (DRY), and vortex impeller for Max head ........... 14.9 m
Impeller.............. vortex
Impeller.............. open multi-channel Max head ........... 75.0 m
Impeller.............. Chopper impeller in


Cast iron structure (stainless steel on request)
Thermal protection devices incorporated in stator
soiled wastewater (DGX). • Long life bearings (100,000 hours)
........................... hard cast iron as standard
• AISI 431 drive shaft (AISI 329 on request)
A set of tools for the complete management and • Leakage detection system in seal chamber (standard)
configuration of Zenit products and spare parts, online and DRY Motor power ...... 2.4 ÷ 15 kW DGB Motor power ...... 0.37 ÷ 1.5 kW DRB Motor power ...... 0.37 ÷ 1.5 kW and motor (on request)
Poles.................. 2/4 Poles.................. 2 Poles.................. 2 • Two silicon carbide mechanical seals in large oil chamber
offline. Select, dimension, search and offer in an easy and Delivery port ...... DN65 ÷ DN100 H Delivery port ...... GAS 2” V Delivery port ...... GAS 1¼”-2” V • Discharge from DN50 to DN500
intuitive way. Free passage ..... max 80 mm Free passage ..... 38 mm Free passage ..... max 15 mm
• Large free passage declared for every model
Max flow rate ..... 72.8 l/s Max flow rate ..... 10.6 l/s Max flow rate ..... 12.5 l/s
Max head ........... 40.2 m Max head ........... 15 m Max head ........... 18 m • Operating temperature up to 60°C (up to 80° on request)
Impeller.............. open multi-channel Impeller.............. vortex Impeller.............. open multi-channel • ATEX II 2G Ex db k IIB T4 / II 2D Ex tb IIIC T135°C
certification

zenit.com/zenonavigator
zenit.com/E-S zenit.com/O zenit.com/F zenit.com/XYB zenit.com/grey zenit.com/uniqa
LIFTING BOX MIXING SYSTEMS
SOLUTIONS FOR COLLECTING AND PUMPING WASTEWATER TO THE SEWER SYSTEM SOLUTIONS FOR THE CIVIL AND INDUSTRIAL WASTEWATER TREATMENT SECTOR
water solutions

Flood Pump Kit nanoBOX Submerged mixers are the key ZMD Structure..................................Cast iron EN-GJL250 ZMR Structure..................................Cast iron EN-GJL250
Pumping-out flooded premises - Clear or slightly soiled wastewaters Domestic wastewater - Wastewater from washing-machines, showers and components of modern water Motors ................................ 0.75 ÷ 4 kW - 4/6/8 poli Motors ........................................4 ÷ 18.5 kW - 4 poli
Stainless steel suction strainer - Plastic box - Delivery Pipe - Connectors sinks - Not suitable for WCs - 10m cable and integral float switch treatment systems. They are Propeller .....................................1450/960/750 rpm Propeller .................................................... 1450 rpm
DOME Included pumps .............DR steel 25 Max flow rate ........................ 30 l/m
Power..................................0.25 kW Max head ................................8.5 m
Capacity.....................................33 l °C Liquid max ............................ 35°
Installed pumps ..................DR steel Max head ................................8.5 m
MIXERS mainly used in equalisation,
homogenisation and denitrification
Propeller ..............................Stainless steel AISI 316
Propeller ...............................................Ø200 ÷ Ø400
Propeller ...............................Stainless steel AISI316
Propeller ................................................... Ø650/900
STIC Poles..............................................2 Dim. ................600 x 400 x 260 mm
Deilvery...........................GAS 1¼” V
Deilvery............................. 1 x DN30 Dim. (mm)..............410 x 360 x 310
................................1 x DN40/DN32
processes, for phosphate extraction
and where liquids have to be mixed
Transmission ................................................... Direct
Thrust .................................................160 ÷ 900 Nm
Transmission ...................................Reduction Gears
Thrust ..............................................1025 ÷4500 Nm
Free passage ................max 10 mm Free passage ................max 10 mm or stirred to reduce sedimentation.

miniBOX
miniBOX makes it possible to create a bathroom in any part of a house, even if
it is a great distance from the soil stack or below the invert level of the drain.
Capacity.......................................6 l Deilvery........................ DN32/DN40
Installed pumps ..................GR steel Dim. ................553 x 356 x 150 mm
Tank material.............. Polyethylene Control system ................Automatic
Installation..................External, wall ...............................with float switch
Cable.......................................1.5 m

Suitable for collecting and lifting 60 Number of pumps .................................... 1 90 Number of pumps .................................... 1
clear, rain and wastewater in °C Liquid max .................................... 40°C °C Liquid max .................................... 40°C
blue systems installed at a lower level Suggested pumps...............DR/DGsteel 37 Suggested pumps...............DR/DGsteel 37

AERATION SYSTEMS
than the sewer. Inlets................................9xØ110 - 1xØ75 Inlets................................9xØ110 - 1xØ75

BOX The entire range uses blue, bluePRO


Series and steel pumps.
Outlets ............................. 1xØ1½” - 1xØ2”
Pipe Deilvery ............................Ø1½” [PVC]
Dim. (mm).................480 x 400 x 370 mm
Outlets ............................. 1xØ1½” - 1xØ2”
Pipe Deilvery .................. Ø1½” - Ø2” [PVC]
Dim. (mm).................480 x 610 x 370 mm

FOR THE CIVIL AND INDUSTRIAL WASTEWATER TREATMENT SECTOR


150 Number of pumps .................................... 1 250 Number of pumps .................................... 1 400 Number of pumps .................................1/2
°C Liquid max .................................... 40°C °C Liquid max .................................... 40°C °C Liquid max .................................... 40°C A line of aeration products for the OXYPLATE 9”/12” OXYTUBE 500/750/1000
Suggested pumps....................DRsteel 37, Suggested pumps...... DRsteel 37,DGsteel 55, Suggested pumps...... DRsteel 55,DGsteel 55, highly specialised civil and industrial Outside diameter ..................................270/340 mm Outside diameter ............................................63 mm
..................................................DGsteel 55
Inlets................................9xØ110 - 1xØ75
........................DGbluePRO 150, GRbluePRO 200
Inlets..............................................6xØ110
........................DGbluePRO 150, GRbluePRO 200
Inlets........................................... 12xØ110 AERA wastewater treatment sector. The Min. operating flow rate................................2 Nm3/h Lunghezza perforazioni ..............500/750/1000 mm

The digital version of this catalogue is available for download at: www.zenit.com
Zenit Group range comprises 9” and Max. operating flow rate.........................6/10 Nm3/h Min. operating flow rate........................ 1/2/3 Nm3/h
Outlets ............................. 1xØ1½” - 1xØ2”
Pipe Deilvery .................. Ø1½” - Ø2” [PVC]
Dim. (mm)........................ 580 x 660 x 480
Outlets .................................1xØ1½” ÷ Ø2”
Pipe Deilvery ............Ø1½” [PVC]- Ø2” [ZN]
Dim. (mm)........................ 900 x 660 x 550
Outlets .................................2xØ1½” ÷ Ø2”
Pipe Deilvery ............Ø1½” [PVC]- Ø2” [ZN]
Dim. (mm)......................900 x 660 x 1000
TION 12” disc-shaped air diffusers, 2”
tubular air diffusers and Venturi-type
Limit flow rate.......................................10/15 Nm3/h
Active surface area ............................ 0.038/0.06 m2
Membrane thickness .............................2 ± 0.15 mm
Max. operating flow rate..................... 6/9/12 Nm3/h
Limit flow rate.................................10/15/20 Nm3/h
Active surface area ....................0.09/0.135/0.18 m2
submerged aerators.
Membrane thickness ............................1.7 ± 0.2 mm
water solutions
vertiBOX lifting stations can be Capacity..................................... 300/420 l
used in a wide range of situations Number of pumps .................................... 1 OXYINOX L305/L610 JETOXY 50
verti thanks to their modular structure,
which allows the installation to be
Suggested pumps....................DR steel 37
°C Liquid max .................................... 40°C
Body material .............................................. AISI 316
Top/bottom hole diameter............................4/8 mm
Diffuser body/cone ......................................GJL-250
Nuts and bolts ....................................Stainless steel

BOX optimised for the specific usage. Inlets.................................. DN50 v DN200


Outlets ................................................ G1¼
Dim. (mm)......................850/1200 x Ø670
Thread connection......................................3/4” NPT
Nominal flow rate ...........................20.0/40.0 Nm3/h
Minimum operating flow rate .............3.5/7.0 Nm3/h
JETOXY 80÷300
Body ............................................ Cast iron GJL-250
Diffuser cone .....................Stainless steel - AISI 304
Maximum operating flow rate...............40/80 Nm3/h
Diaphram ....................................................Vulkollan
Pressure drops at nominal flow rate.............~9.5 cm
Nuts and bolts ....................................Stainless steel

PRODUCT
The sphereBOX lifting station Capacity........................... 600/900/1200 l
incorporates various modular Number of pumps .................................1/2
sphere
CONTROL PANELS
components allowing a custom Suggested pumps.............DG/GRbluePRO,
composition which adapts to the ................................................ DG/GR Grey
submersible electric pumps
BOX °C Liquid max .................................... 40°C

OVERVIEW
needs of users.
Deilvery......................................... 1¼” - 2”
Dim. (mm)......................1405/1705/2050
aeration and mixing systems
..................................x Ø1125/1155/1155 lifting stations FOR SINGLE OR THREE-PHASE SUBMERSIBLE PUMP, WITH DIRECT OR STAR/DELTA STARTING
control panels
Range up to 18000 litres designed to M Capacity...........................................1000 l V Capacity...........................................2000 l Zenit electronic and ELECTROMECHANICAL STANDARD ELECTROMECHANICAL FULL SERVICE
withstand underground pressures and Number of pumps .................................1/2 Number of pumps .................................1/2 electromechanical control panels Electromechanical control panels, designed to Electromechanical control panels, including gradual
BOX ensure rapid installation.
BOX PRO lifting stations can house
Suggested pumps................... DG/GR Grey
................................ Uniqa ZUG V/ ZUG GR
Suggested pumps................... DG/GR Grey
................................ Uniqa ZUG V/ ZUG GR CONTROL are suitable for the control of
any single-phase or three-phase
control 1, 2 or 3 single-phase, direct starting
three-phase or Y/Delta starting three-phase pumps,
machine start and stop with integrated soft-start
devices, or variable speed motor operation with

PRO either one or two submersible pumps


with vortex, channel or grinding
°C Liquid max .................................... 40°C
Inlets..............................3xØ160 - 2xØ110
Outlets ......................1/2 x DN50 ÷ DN150
°C Liquid max .................................... 40°C
Inlets..............................3xØ160 - 2xØ110
Outlets ......................1/2 x DN50 ÷ DN150
PANELS submersible pump, with direct or
star/delta starting.
are made using the best components available, to
guarantee excellent reliability and easy procurement
of replacement parts.
inverters, which allow regulation of the pump’s
duty point.
impellers.
Dim. (mm)................. 1140 x 1326 x Ø800 Dim. (mm)................. 1016 x 2310 x Ø600

S Capacity...............................4000 ÷ 9500 l J Capacity...........................10000 ÷ 18000 l ELECTRONIC STANDARD ELECTRONIC FULL SERVICE


Number of pumps .................................1/2 Number of pumps .................................1/2 Electronic control panels designed to control 1, 2 or State-of-the-art management and control tool,
Suggested pumps................... DG/GR Grey Suggested pumps................... DG/GR Grey 3 single-phase pumps with power from 0.37 kW up for their pumping systems in addition to standard
DRAINAGE ................................ Uniqa ZUG V/ ZUG GR ................................ Uniqa ZUG V/ ZUG GR to 2.2 kW or 1, 2 or 3 three-phase pumps with power electronic control panel functions: a multilingual
SOLUTION °C Liquid max .................................... 40°C °C Liquid max .................................... 40°C from 0.55 kW up to 15 kW. menu allows the users to select the operating mode
Inlets..............................3xØ160 - 2xØ110 Inlets..............................3xØ160 - 2xØ110 The data provided are not binding. Designed for use with float switches or level sensors, best suited to requirements, optimising running and
WASTEWATER Outlets ......................1/2 x DN50 ÷ DN150 Outlets ......................1/2 x DN50 ÷ DN150 Zenit reserves the right to modify the product without advance notification. they allow users to set alternating pump duty cycles maintenance costs.
SOLUTION Dim. (mm)..... 1624 x 2015 ÷ 4500 x Ø800 Dim. (mm)...2246 x 2520 ÷ 4500 x Ø1000 and maximum or minimum level alarm output. With the aid of an optional APP, users can monitor all
system operation aspects at all times.
For further information, visit www.zenit.com Cod. 29040060040200002 zenit.com
Rev. 7 - 2019 - EN

You might also like