Modern Civil Construction LLP

Nature of Work - EXTERNAL SERVICES WORKS


#REF!
As Per Amendment-01 As Per Amendment-02

A
m Previous This Bill Cummulative
SR. NO. ITEM DESCRIPTION UNIT o
Qty Amount Qty Amount Qty Qty Qty
u
n
t

I EXTERNAL SEWERAGE SYSTEM:


Excavating trenches of required width for pipes including excavation for socket and
dressing of sides ramming of bottoms depth upto 1.50 m, getting out the excavated
soil and then returning the soil as required in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering etc. and disposal of
surplus excavated soil as directed outside the site to the approved dumping ground.
1.0 Minimum width of the trench should be external pipe diameters plus 300mm as
specifed in the specifications.

All kinds of soil & hard rock if exist.


a) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 1,751.00 1,751.00 720.60 - 720.60
b) Pipes exceeding 300 mm dia but not exceeding 600 mm dia. Metre 16.00 16.00
- -
Extra for excavating trenches for pipes in all soils & hard rock if exist for depth
exceeding 1.50 m but not exceeding 3.0 Metre. (Including open/close timbering,
strutting, shoring and packing cavaties wherever required). Minimum width of the
2.0 trench should be external pipe diameters plus 400mm as specifed in the
specifications.

- -
a) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 928.00 928.00
b) Pipes exceeding 300 mm dia but not exceeding 600 mm dia. Metre 16.00 16.00 - -
- -
Extra for excavating trenches for pipes in all soils and hard rock if exist for depth
exceeding 3.0 m but not exceeding 4.50 Metre. (Including open/close timbering,
strutting, shoring and packing cavaties wherever required). Minimum width of the
3.0 trench should be external pipe diameters plus 400mm as specifed in the
specifications.

- -
a) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 5.00 5.00
b) Pipes exceeding 300 mm dia but not exceeding 600 mm dia. Metre 22.00 22.00
- -
Providing, lowering, laying, testing & commissioning (cut surface to be uniformly
finished) of Non-pressure uPVC pipes, conforming to IS:15328-2003 including all
required fittings & jointing with coupler of click ring and elastomeric sealing rings for
up to 250 mm dia. and solvent joint type coupler for 315 mm and 400mm dia pipes
4.0 and specials into trenches of all depths including carriage, loading, unloading etc.
complete in all respects to the satisfaction of the engineer-in-charge.

- -
Main Lines SDR-41 (SN 4 kn/m2) - -
160 mm OD (150 mm ID)
4.1 Base Rate of Pipe only = Rs. 406/- F.O.R. Site excluding GST Metre 928.00 928.00
Material Supply (60%) 174.00 174.00
Laying,fixing 25% 125.75 - 125.75
Testing of pipe 5% 125.75 - 125.75
Commissioning 5% - -
Balance 5 % against Hand over - -

200 mm OD (200 mm ID)


4.2 Base Rate of Pipe only = Rs. 620/- F.O.R. Site excluding GST Metre 644.00 644.00 - -
Material Supply (60%) 474.00 170.00 644.00
Laying,fixing 25% 474.00 120.85 594.85
Testing of pipe 5% 474.00 120.85 594.85
Commissioning 5% - -
Balance 5 % against Hand over - -
1 of 12
250 mm OD (250 mm ID)
4.3 Base Rate of Pipe only = Rs. 975/- F.O.R. Site excluding GST Metre 120.00 120.00
315 mm OD (300 mm ID)
4.4 Base Rate of Pipe only = Rs. 1525/- F.O.R. Site excluding GST Metre 60.00 60.00
400 mm OD (400 mm ID)
4.5 Base Rate of Pipe only = Rs. 1950/- F.O.R. Site excluding GST Metre 16.00 16.00
- -
Providing, Fixing, Testing & Commissioning uPVC pipes (6 Kg/Cm ) conforming to IS
2

4985-2000 including injection moulded fittings wherever required e.g. tees, bends etc.
of any degree, clamps, couplings, adopters, plugs, enlarger sockets etc and jointing
with solvent cement including cutting holes in R.C.C/brick work (slab/beam/wall) and
5.0 making good the floors, beams and walls with cement mortar wherever required
complete in all respect.

- -
110 mm OD.
a) Base Rate of Pipe only = Rs. 264/- F.O.R. Site excluding GST Metre 16.00 16.00
160 mm OD.
b) Base Rate of Pipe only = Rs. 365/- F.O.R. Site excluding GST Metre 27.00 27.00
- -
Providing and laying Cement Concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded
stone aggregate 40 mm nominal size) 100 mm up to top of uPVC pipes including 100
mm thick bed concrete as per standard design drawing complete in all respect.
6.0 (RMC Shall be Provided by Owner Free of Cost at one point)

- -
6.1 100 mm diameter. (110 OD) Metre 16.00 16.00
6.2 150 mm diameter. (160 OD) Metre 955.00 955.00 125.75 - 125.75
6.3 200 mm diameter. (200 OD) Metre 644.00 644.00 594.85 - 594.85
6.4 250 mm diameter. (250 OD) Metre 120.00 120.00
6.5 300 mm diameter. (300 OD) Metre 60.00 60.00
6.6 400 mm diameter. (400 OD) Metre 33.00 33.00
- -
Providing & Constructing brick masonry Rectangular/ Square type Manhole with FPS
class designation 75, 230 mm thick brick wall in cement mortar 1:5 (1 Cernent : 5
Coarse sand), 12mm thick inside cement plastering with cement mortar 1:3 (1
cement : 3 coarse sand) finished with a floating coat of neat cement inside, 12 mm
thick outside plastering with cement mortar 1:3 (1 cement : 3 coarse sand), 150mm
thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size), fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) and making necessary channels &
7.0 benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) finished with a floating coat of neat cement, including
necessary excavation, refilling, centering, shuttering, staging and disposal of surplus
earth, suitably masonry plug for the pipes mouth or as directed by Engineer-incharge
complete in all respect & as per design.

- -
- -
a) Inside size= 45x45cm and 45 cm deep with S.F.R.C cover and frame (medium duty,
MD-10 grade designation) inside clear size 450x450 mm, lifting hooks, conforming to
IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).

Each 1.00 1.00

b) Inside size=60x60cm and 60 cm deep with S.F.R.C cover and frame (medium duty,
MD-10 grade designation) inside clear size 600x600 mm, lifting hooks, conforming to
IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).

Each 104.00 104.00


Part rate 60% 20.00 - 20.00
Part rate 25% 2.40 - 2.40
Part rate 5%
Part rate 5%
Part rate 5%
- -

2 of 12
c) Inside size=75 x 75 cm and 75 cm deep with S.F.R.C cover and frame (medium duty,
MD-10 grade designation) inside clear size 600x600 mm, lifting hooks, conforming to
IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).

Each 5.00 5.00


- -
a) Extra depth for rectangular type manhole 450 x 450 mm internal with FPS bricks.
8.0 Beyond 450 mm & up to 600 mm. Metre 1.00 1.00
- -
b) Extra depth for rectangular type manhole 600 x 600 mm internal with FPS bricks.
Beyond 600 mm & up to 750 mm. Metre 31.00 31.00
- -
c) Extra depth for rectangular type manhole 750 x 750 mm internal with FPS bricks.
Beyond 750 mm & up to 1000 mm. Metre 3.00 3.00
- -
Providing & Constructing brick masonry Circular type Manhole 0.91 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 150mm thick foundation concrete
9.0 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels

- -
A) 0.91 m deep with S.F.R.C cover and frame (Heavy duty, HD-20 grade designation)
560 mm internal diameter, lifting hooks, mild steel rims to prevent damaging of edges,
conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).

Each 37.00 37.00


Part rate 60% 60% 27.00 - 27.00
Part rate 25% 25% 13.20 13.20
Part rate 5% 5% - - -
Part rate 5% 5%
Part rate 5% 5%
Extra depth for circular type manhole 0.91 m internal dia (at bottom ) with FPS bricks.
10.0 Beyond 0.91m & up to 1.65 m. Metre 19.00 19.00 - -
- -
Providing & Constructing brick masonry Circular type Manhole 1.22 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12 mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 200mm thick foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels & benching in cement concrete 1:2:4 (1
11.0 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, including necessary excavation, refilling, centering,
shuttering, staging and disposal of surplus earth, suitably masonry plug for the pipes
mouth or as directed by Engineer-incharge complete in all respect & as per standard
detail design drawing.

- -
1.66 m deep with S.F.R.C cover and frame (Heavy duty, HD-20 grade designation) 560
mm internal diameter, lifting hooks, mild steel rims to prevent damaging of edges,
conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Each 23.00 23.00 - -
Part rate 60% 60% 4.00 - 4.00
Part rate 25% 25% 2.40 - 2.40
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%
- -
Extra depth for circular type manhole 1.22 m internal dia (at bottom) with FPS bricks.
12.0 Beyond depth 1.66 m & up to 2.29 m. Metre 11.00 11.00
- -

3 of 12
Providing & Constructing brick masonry Circular type Manhole 1.52 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 300mm thick foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels & benching in cement concrete 1:2:4 (1
13.0 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, including necessary excavation, refilling, centering,
shuttering, staging and disposal of surplus earth, suitably masonry plug for the pipes
mouth or as directed by Engineer-incharge complete in all respect & as per standard
detail design drawing.

- -
2.30 m deep with S.F.R.C cover and frame (Heavy duty, HD-20 grade designation) 560
mm internal diameter, lifting hooks, mild steel rims to prevent damaging of edges,
conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Each 8.00 8.00
Part rate 60% 60% 2.00 - 2.00
Part rate 25% 25% 2.00 - 2.00
Part rate 5% 5% 2.00 - 2.00
Part rate 5% 5%
Part rate 5% 5%
- -
Extra depth for circular type manhole 1.52 m internal dia with F.P.S Bricks. Beyond 2.3
14.0 m depth. Metre 5.00 5.00
- -
Providing and fixing orange colour safety foot rest provided in all manholes over 0.9m
of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar
conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and overall
minimum length 263 mm and width as 165 mm with space between protruded legs
having 2 mm tread on top surface by ribbing on chequering besides necessary and
adequate anchoring projections on tall length on 138 mm as per standard drawing and
suitable to with stand the bend test and chemical resistance test as per specifications
and having manufacturer’s permanent identification mark to be visible even after
15.0 fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:2:4 (1
cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), 300 mm apart
horizontally as well as vertically & project 100 mm beyond the wall. Top rung shall be
450 mm below the manhole cover & the lowest not more than 300 mm above the
benching or complete as per standard design.

Each 338.00 338.00 59.00 - 59.00


- -
Providing & fixing square mouth uPVC Gully Trap of 100 mm outlet complete with
16.0 water tight SFRC cover & brick masonary chamber of size=300 x 300 mm (inside)
complete as per standard design.
Each 1.00 1.00
- -
TOTAL C/F TO SUMMARY ### - -
- - - -
II EXTERNAL STORM WATER DRAINAGE SYSTEM: - - - -
Excavating trenches of required width for pipes including excavation for socket and
dressing of sides ramming of bottoms depth upto 1.50 m, getting out the excavated
soil and then returning the soil as required in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering etc. and disposal of
1.0 surplus excavated soil as directed outside the site to the approved dumping ground.
Minimum width of the trench should be external pipe diameters plus 300mm as
specifed in the specifications.
- -
All kinds of soil & hard rock if exist. - -
a) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 848.00 848.00 176.75 - 176.75
b) Pipes exceeding 300 mm dia but not exceeding 600 mm dia. Metre 840.00 840.00 570.20 - 570.20
- -
Extra for excavating trenches for pipes in all soils & hard rock if exist for depth
exceeding 1.50 m but not exceeding 3.0 Metre. (Including open/close timbering,
strutting, shoring and packing cavaties wherever required). Minimum width of the
2.0 trench should be external pipe diameters plus 400mm as specifed in the
specifications.
- -
a) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 65.00 65.00
b) Pipes exceeding 300 mm dia but not exceeding 600 mm dia. Metre 355.00 355.00 - -
- -

4 of 12
Providing, lowering, laying and cutting (cut surface to be uniformly finished) jointing
with rubber rings marked with IS:5382 and testing of spigot and socketed non
pressure R.C.C. Pipes of Class NP-3 conforming to IS:458 sulphate resisting cement
3.0 marked with IS:12330 and specials into trenches of all depths including carriage,
loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-
charge.
- -
150 mm dia.
3.1 Base Rate of Pipe only = Rs. 216/- F.O.R. Site excluding GST Metre 829.00 829.00
Material Supply (60%) 60% 164.00 - 164.00
Laying,fixing (25%) 25% 113.55 - 113.55
Testing of pipe (5%) 5% 19.00 19.00
Commissioning (5%) 5% - -
Hand over (5%) 5% - -
200 mm dia.
3.2 Base Rate of Pipe only = Rs. 288/- F.O.R. Site excluding GST Metre 19.00 19.00
Material Supply (60%) 60% 19.00 - 19.00
Laying,fixing (25%) 25% 19.00 - 19.00
Testing of pipe (5%) 5% 19.00 19.00
Commissioning (5%) 5%
Hand over (5%) 5%
400 mm dia.
3.3 Base Rate of Pipe only = Rs. 896/- F.O.R. Site excluding GST Metre 813.00 813.00 - -
Material Supply (60%) 60% 560.00 10.00 570.00
Laying,fixing (25%) 25% 560.00 9.70 569.70
Testing of pipe (5%) 5% 560.00 9.70 569.70
Commissioning (5%) 5% - -
Hand over (5%) 5% - -
450 mm dia.
3.4 Base Rate of Pipe only = Rs. 1050/- F.O.R. Site excluding GST Metre 27.00 27.00
- -
Providing and laying Cement Concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded
stone aggregate 40 mm nominal size) 100 mm thick in bed of RCC pipes & up to
haunches including the cost of centering and shuttering as per standard design &
4.0 drawing complete in all respect.
(RMC Shall be Provided by Owner Free of Cost at one point)

- -
4.1 150 mm dia. Metre 829.00 829.00 113.55 - 113.55
4.2 200 mm dia. Metre 19.00 19.00 19.00 - 19.00
4.3 400 mm dia. Metre 813.00 813.00 569.20 - 569.20
4.4 450 mm dia. Metre 27.00 27.00
- -
Providing & Constructing brick masonry Rectangular/ Square type Manhole with FPS
class designation 75, 230 mm thick brick wall in cement mortar 1:5 (1 Cernent : 5
Coarse sand), 12mm thick inside cement plastering with cement mortar 1:3 (1
cement : 3 coarse sand) finished with a floating coat of neat cement inside, 12 mm
thick outside plastering with cement mortar 1:3 (1 cement : 3 coarse sand), 150mm
thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size). fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) and making necessary channels &
5.0 benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) finished with a floating coat of neat cement, including
necessary excavation, refilling, centering, shuttering, staging and disposal of surplus
earth, suitably masonry plug for the pipes mouth or as directed by Engineer-incharge
complete in all respect & as per design.

- -
Inside size= 450x450 mm and 450 mm deep with S.F.R.C cover/grating and frame
(medium duty, MD-10 grade designation) inside clear size 450x450 mm, lifting hooks,
a) conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Each 123.00 123.00 - - -
- -
Extra depth for square type manhole 450x450 mm internal with FPS bricks. Beyond
b) 450 mm & up to 600 mm. Metre 21.00 21.00
- -
Inside size= 600x600 mm and 600 mm deep with S.F.R.C cover/grating and frame
(medium duty, MD-10 grade designation) inside clear size 600x600 mm, lifting hooks,
c) conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Each 65.00 65.00
Part rate 60% 60% 22.00 - 22.00

5 of 12
Part rate 25% 25% 5.40 - 5.40
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%
- -
Extra depth for square type manhole 600x600 mm internal with FPS bricks. Beyond
d) 600 mm & up to 750 mm. Metre 17.00 17.00
- -
Inside size=750x750 mm and 750 mm deep with S.F.R.C cover/grating and frame
(medium duty, MD-10 grade designation) inside clear size 600x600 mm, lifting hooks,
e) conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Each 5.00 5.00
- -
Extra depth for square type manhole 750x750 mm internal with FPS bricks. Beyond
f) 750 mm & up to 1000 mm. Metre 10.00 10.00
- -
Providing & Constructing brick masonry Circular type Manhole 0.91 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 150mm thick foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels & benching in cement concrete 1:2:4 (1
6.0 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, including necessary excavation, refilling, centering,
shuttering, staging and disposal of surplus earth, suitably masonry plug for the pipes
mouth or as directed by Engineer-incharge complete in all respect & as per standard
design.

- -
A) 0.91 m deep with S.F.R.C cover/grating and frame (Heavy duty, HD-20 grade
designation) 560 mm internal diameter, lifting hooks, mild steel rims to prevent
damaging of edges, conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Each 53.00 53.00
Part rate 60% 60% 23.00 - 23.00
Part rate 25% 25% 13.00 - 13.00
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%
- -
Extra depth for circular type manhole 0.91 m internal dia (at bottom ) with FPS bricks.
7.0 Beyond 0.91m & up to 1.65 m. Metre 37.00 37.00
- -
Providing & Constructing brick masonry Circular type Manhole 1.22 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12 mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 200mm thick foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels & benching in cement concrete 1:2:4 (1
8.0 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, including necessary excavation, refilling, centering,
shuttering, staging and disposal of surplus earth, suitably masonry plug for the pipes
mouth or as directed by Engineer-incharge complete in all respect & as per standard
detail design drawing.

- -
1.66 m deep with S.F.R.C cover/grating and frame (Heavy duty, HD-20 grade
designation) 560 mm internal diameter, lifting hooks, mild steel rims to prevent
damaging of edges, conforming to IS:12592, fixed in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Each 10.00 10.00
Part rate 60% - - 9.00 - 9.00
Extra depth for circular type manhole 1.22 m internal dia (at bottom) with FPS bricks.
9.0 Beyond depth 1.66 m & up to 2.29 m. Metre 8.00 8.00
- -

6 of 12
Providing & Constructing brick masonry Circular type Manhole 1.52 m internal dia.
with FPS class designation 75 in cement mortar 1:5 (1 Cement : 5 Coarse sand), 12mm
thick inside cement plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with a floating coat of neat cement inside, 12 mm thick outside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand), 300mm thick foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
fixing cover with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and making necessary channels & benching in cement concrete 1:2:4 (1
10.0 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a
floating coat of neat cement, including necessary excavation, refilling, centering,
shuttering, staging and disposal of surplus earth, suitably masonry plug for the pipes
mouth or as directed by Engineer-incharge complete in all respect & as per standard
detail design drawing.

- -
2.30 m deep with S.F.R.C cover/grating and frame (Heavy duty, HD-20 grade
designation) 560 mm internal diameter, lifting hooks, mild steel rims to prevent
damaging of edges, conforming to IS:12592, fixed in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Each 2.00 2.00
- -
Extra depth for circular type manhole 1.52 m internal dia with F.P.S Bricks. Beyond 2.3
11.0 m depth. Metre 1.00 1.00
- -
Providing and fixing orange colour safety foot rest provided in all manholes over 0.9m
of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar
conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and overall
minimum length 263 mm and width as 165 mm with space between protruded legs
having 2 mm tread on top surface by ribbing on chequering besides necessary and
adequate anchoring projections on tall length on 138 mm as per standard drawing and
suitable to with stand the bend test and chemical resistance test as per specifications
and having manufacturer’s permanent identification mark to be visible even after
12.0 fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:2:4 (1
cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), 300 mm apart
horizontally as well as vertically & project 100 mm beyond the wall. Top rung shall be
450 mm below the manhole cover & the lowest not more than 300 mm above the
benching or complete in all respect as per standard design.

Each 246.00 246.00 59.00 - 59.00


TOTAL C/F TO SUMMARY ### 0.00 0.00
III EXTERNAL WATER SUPPLY: - -
Excavating trenches of required width for pipes including excavation for socket and
dressing of sides ramming of bottoms depth upto 1.5 m, getting out the excavated soil
and then returning the soil as required in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering etc. and disposal of
1.0 surplus excavated soil as directed outside the site to the approved dumping ground.
Minimum width of the trench should be external pipe diameters plus 300mm as
specifed in the specifications.
- -
All kinds of soil & hard rock if exist. - -
a) Pipes not exceeding 80 mm dia. Metre 1,296.00 1,296.00
b) Pipes exceeding 80 mm dia but not exceeding 300 mm dia. Metre 698.00 698.00 40.40 - 40.40
- -

7 of 12
Providing, laying, testing, commissioning S & S Ductile Iron pipes confirming to
IS:8329, inside cement mortar lining, outside zinc coated / bitumen coated, suitable
for tyton jointing including all standard specials (heavy class K-12) confirming to
IS:9523 such as bends, crosses, tees, tapers with large end socketed, flanged socketed
tail pieces, double flanged DI duck foot bends, flanged, spigot and socketed tail pieces,
end caps, including push-on-joints with premoulded rubber ring including the cost of
rubber gasket, providing thrust blocks in cement concrete 1:2:4 (1 cement : 2 coarse
sand: 4 graded stone aggregate 20 mm nominal size) alround D.I. pipes at bends,
junctions etc., Disinfecting D.I. water mains by flushing with water containing
bleaching powder at 0.5 gm per litre of water and cleaning the same with fresh water,
operation to be repeated three times including getting the samples of water from the
disinfected main tested in the municipal laboratory etc. Complete in all respect.
2.0

- -
100 mm dia Ductile Iron Class K-9 pipes
2.1 Base Rate of Pipe only = Rs. 795/- F.O.R. Site excluding GST Metre 589.00 589.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

150 mm dia Ductile Iron Class K-9 pipes


2.2 Base Rate of Pipe only = Rs. 1098/- F.O.R. Site excluding GST Metre 106.00 106.00
- -
Providing, laying and Jointing (with holdtight/Loctide with teflon Tape) G.I. pipes and
fittings conforming to IS:1239 (Medium class) with all required fittings, elbow, tee,
socket, union, plug, cross, nipple, reducer, flanges etc. including anticorrosive
treatment to buried pipes by wrapping with 2 mm thick anti-corrosive tape applied
over a coat of primer complete in all respects.
(Pipes in trenches for external works).
3.0

- -
20 mm dia nominal bore
3.1 Base Rate of Pipe only = Rs. 115/- F.O.R. Site excluding GST Metre 1,031.00 1,031.00
25 mm dia nominal bore
3.2 Base Rate of Pipe only = Rs. 162/- F.O.R. Site excluding GST Metre 5.00 5.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

32 mm dia nominal bore


3.3 Base Rate of Pipe only = Rs. 205/- F.O.R. Site excluding GST Metre 11.00 11.00
40 mm dia nominal bore
3.4 Base Rate of Pipe only = Rs. 239/- F.O.R. Site excluding GST Metre 5.00 5.00
50 mm dia nominal bore
3.5 Base Rate of Pipe only = Rs. 328/- F.O.R. Site excluding GST Metre 142.00 142.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

65 mm dia nominal bore


3.6 Base Rate of Pipe only = Rs. 423/- F.O.R. Site excluding GST Metre 95.00 95.00

8 of 12
80 mm dia nominal bore
3.7 Base Rate of Pipe only = Rs. 527/- F.O.R. Site excluding GST Metre 5.00 5.00
100 mm dia nominal bore
3.8 Base Rate of Pipe only = Rs. 850/- F.O.R. Site excluding GST Metre 3.00 3.00
150 mm dia nominal bore
3.9 Base Rate of Pipe only = Rs. 1450/- F.O.R. Site excluding GST Metre 3.00 3.00
- -
Providing and fixing brass ferrule with C.I. mouth cover including saddle, boring and
4.0 tapping with the main line of required size as per drawing & all necessary fittings
complete in all respect.
Each 2.00 2.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

Supply, installation, testing, commissioning & handing over of Cast Iron Butterfly
Valve (upto 150mm dia with hand lever operation & above with gear box operation)
PN-10 with SS-304 disc set duly ISI marked complete in all respect with rubber gasket,
5.0 two nos. of matching flanges on both sides, nuts, bolts, washers of following sizes as
required as per specifications.
- -
5.1 65 mm dia nominal bore Each 1.00 1.00
5.2 80 mm dia nominal bore Each 1.00 1.00
5.3 100 mm dia nominal bore Each 5.00 5.00
5.4 150 mm dia nominal bore Each 2.00 2.00
- -
Providing & Constructing Masonry Chamber 45 x 45 x 60 cms inside with 75 class
designation 230 mm thick brick work in cement mortar 1:5 (1 cement : 5 fine sand)
for Butterfly Valve/Ball Valve including SFRC (or solid as per site) cover and frame
(Medium duty MD-10 grade designation) 450x450mm internal dimensions of
manholes with necessary excavation, re-filling, centering, shuttering, 100 mm thick
6.0 foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate
40 mm nominal size) and inside & outside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement
complete in all respect & as per standard design.

- -
With F.P.S. bricks Each 3.00 3.00
- -
Providing & Constructing masonry Chamber 60 x 60 x 90 cm, inside with FPS 230 mm
thick brick wall of 75 class designation brick work in cement mortar 1:4 (1 cement : 4
coarse sand) for sluice valve/butterfly valve with SFRC cover & frame 600 x 600 mm
size (inside) of manholes with RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) necessary excavation, re-filling,
centering, shuttering, 150 mm thick foundation concrete 1:5:10 (1 cement : 5 fine
7.0 sand : 10 graded stone aggregate 40 mm nominal size ) and 12 mm thick inside &
outside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) finihed with a
floating coat of neat cement complete in all respect & as per standard design.

Each 5.00 5.00


- -
Providing & Constructing masonry Chamber 90 x 90 x 120 cm, inside with FPS 230 mm
thick bricks of 75 class designation brick work in cement mortar 1:5 (1 cement : 5
coarse sand) for sluice/butterfly valve, with SFRC cover & frame 600 x 600 mm size
(inside) with RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) necessary excavation, re-filling, centering, shuttering,
8.0 staging, 150 mm thick foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size) and inside & outside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat
cement complete in all respect & as per standard design.

Each 1.00 1.00


- -
Providing and fixing C.I. double acting air release valve marked with IS:14845 including
making connection to pipe line / fittings, cost of carriage, loading, unloading, testing
9.0 and commissioning complete in all respect with bolts, nuts, rubber insertions etc.
- -
9.1 80 mm dia Each 2.00 2.00
- -
TOTAL C/F TO SUMMARY ### - - - -
IV FLUSHING & IRRIGATION SYSTEM: - - - -

9 of 12
Excavating trenches of required width for pipes including excavation for socket and
dressing of sides ramming of bottoms depth upto 1.5 m, getting out the excavated soil
and then returning the soil as required in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering etc. and disposal of
1.0 surplus excavated soil as directed outside the site to the approved dumping ground.
Minimum width of the trench should be external pipe diameters plus 250mm as
specifed in the specifications.
- -
All kinds of soil & hard rock if exist. - -
a) Pipes not exceeding 150 mm dia. Metre 1,389.00 1,389.00 75.00 - 75.00
- - -
Providing, laying & jointing in position uPVC pipe conforming to IS:4985:1988 and
suitable for the respective working pressures with all required fittings and accessories
e.g. couplings, tees, bends, reducers, male & female screwed adapters, flanged & tail
pieces, male & female brass threaded adapters, bush, flange adapter, tail piece, end
cap fittings etc. jointing as per manufacturers instructions, providing thrust blocks in
cement conc. 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm
nominal size) alround PVC pipes at bends, junctions, croses etc., Disinfecting PVC
water mains by flushing with water containing bleaching powder at 0.5 gm per litre of
water and cleaning the same with fresh water, operation to be repeated three times
complete in all respect. (For Flushing & Irrigation Water Supply System).
2.0

- - -
uPVC pipe 25mm OD (10 Kg/Cm2) for Irrigation.
Base Rate of Pipe only = Rs. 25/- F.O.R. Site excluding GST
2.1
Metre 112.00 112.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

uPVC pipe 32mm OD (10 Kg/Cm2) for Irrigation.


2.2 Base Rate of Pipe only = Rs. 40/- F.O.R. Site excluding GST
Metre 55.00 55.00 -
uPVC pipe 40mm OD (6 Kg/Cm2) for Irrigation.
2.3 Base Rate of Pipe only = Rs. 39/- F.O.R. Site excluding GST
Metre 104.00 104.00 -
uPVC pipe 50mm OD (6 Kg/Cm2) for Irrigation.
2.4 Base Rate of Pipe only = Rs. 59/- F.O.R. Site excluding GST
Metre 131.00 131.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

uPVC pipe 50mm OD (10 Kg/Cm2) for Flushing Water Supply Line.
2.5 Base Rate of Pipe only = Rs. 59/- F.O.R. Site excluding GST
Metre RO RO -
uPVC pipe 63mm OD (6 Kg/Cm2) for Irrigation.
2.6 Base Rate of Pipe only = Rs. 95.76/- F.O.R. Site excluding GST
Metre 240.00 240.00 -
uPVC pipe 75mm OD (6 Kg/Cm2) for Irrigation.
2.7 Base Rate of Pipe only = Rs. 148/- F.O.R. Site excluding GST
Metre 27.00 27.00 - - -
Part rate 60% 60%
Part rate 25% 25%
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

uPVC pipe 90mm OD (6 Kg/Cm2) for Irrigation.


2.8 Base Rate of Pipe only = Rs. 182/- F.O.R. Site excluding GST
Metre 218.00 218.00 - - -
Part rate 60% 60%
Part rate 25% 25%
10 of 12
Part rate 5% 5%
Part rate 5% 5%
Part rate 5% 5%

uPVC pipe 110mm OD (6 Kg/Cm2) for Irrigation.


2.9 Base Rate of Pipe only = Rs. 264/- F.O.R. Site excluding GST
Metre 480.00 480.00 -
uPVC pipe 110mm OD (10 Kg/Cm2) for Flushing Water Supply Line.
3.0 Base Rate of Pipe only = Rs. 264/- F.O.R. Site excluding GST
Metre RO RO -
uPVC pipe 160mm OD (6 Kg/Cm2) for Flushing Water Supply Line.
3.1 Base Rate of Pipe only = Rs. 350/- F.O.R. Site excluding GST Metre 22.00 22.00 -
- - -
Providing and fixing 25 mm OD hydrant point including all required fittings, reducers,
3.0 bend, G.I. nipple etc. with arrangement of fixing PVC pipe of required suitable length
according to requirement & complete in all respects.
Each 14.00 14.00 -
-
Providing, fixing, Testing & Commissioning of forged brass lever operated Ball Valve of
full flow with forged brass ball (Machined to mirror smooth finish with hard chrome
plated) and spindle with setting and gland of superior quality having minimum working
4.0 pressure of 10 kg/cm2 etc. complete in all respect. Rates includes union or brass male/
female adopter for jointing with uPVC pipes and G.I pipes.
-
a) 25 mm nominal bore Each 1.00 1.00 -
b) 32 mm nominal bore Each 3.00 3.00 -
c) 40 mm nominal bore Each 1.00 1.00 -
d) 50 mm nominal bore Each 1.00 1.00 -
- - -
Providing and fixing Cast Iron Butterfly Valve (wafer type) as per IS:13095 of Class PN-
10, having SS-304 disc, carbon steel shaft, EPDM/nitrile rubber field replacible body
4.0 lining, including a set of MS flanges, tail piece or any other arrangement required, nos.
of nut & bolts all fitting required for jointing complete in all respect.
- - -
4.1 65 mm diameter Each 9.00 9.00 -
4.2 80 mm diameter Each 2.00 2.00 -
4.3 100 mm diameter Each 4.00 4.00 -
- - -
Providing & Constructing Masonry chamber 45x45x60 cms inside with 75 class
designation 230 mm thick brick work in cement mortar 1:5 (1 cement : 5 fine sand)
for Butterfly Valve/Ball Valve including SFRC (or solid as per site) cover and frame
(Medium duty MD-10 grade designation) 450x450mm internal dimensions with
necessary excavation, re-filling, centering, shuttering, 100 mm thick foundation
5.0 concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm
nominal size) and inside & outside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick finished with a floating coat of neat cement complete in all
respect & as per standard design With F.P.S. bricks.

Each 1.00 1.00 -


- - -
Providing & Constructing Masonry chamber 60x60x75 cms inside with 75 class
designation 230 mm thick brick work in cement mortar 1:5 (1 cement : 5 fine sand)
for Butterfly Valve/Ball Valve including SFRC (or solid as per site) cover and frame
(Medium duty MD-10 grade designation) 600x600mm internal dimensions with
R.C.C.top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) necessary excavation, re-filling, centering, shuttering, 100 mm thick
6.0 foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate
40 mm nominal size) and inside & outside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement
complete in all respect & as per standard design With F.P.S. bricks.

Each 2.00 2.00 -


- - -

11 of 12
Providing and fixing PVC Ball Valve having flow indicator when lever is removed,
security pivot to maintain lever in space, double water tight joint, direct injection stem
7.00 non mechanical, with a base which permits maximum penetration into the valve
complete in all respect.
- - -
7.1 20 mm dia. Nominal bore Each 14.00 14.00 -
7.2 25 mm dia. Nominal bore Each 1.00 1.00 -
7.3 32 mm dia. Nominal bore Each 2.00 2.00 -
7.4 40 mm dia. Nominal bore Each 4.00 4.00 -
7.5 50 mm dia. Nominal bore Each 3.00 3.00 -
- - -
Providing, lowering, laying and cutting (cut surface to be uniformly finished) jointing
with rubber rings marked with IS:5382 and testing of spigot and socketed non
pressure R.C.C. Pipes of Class NP-2 conforming to IS:458 sulphate resisting cement
8.0 marked with IS:12330 and specials into trenches of all depths including carriage,
loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-
charge (Pipe under road crossings).
- - -
150 mm dia.
8.1 Base Rate of Pipe only = Rs. 190/- F.O.R. Site excluding GST Metre 44.00 44.00 44.00 - 44.00
200 mm dia.
8.2 Base Rate of Pipe only = Rs. 250/- F.O.R. Site excluding GST Metre 27.00 27.00 27.00 - 27.00
300 mm dia.
8.3 Base Rate of Pipe only = Rs. 422/- F.O.R. Site excluding GST Metre 27.00 27.00 -
- -
TOTAL C/F TO SUMMARY ### - - - -
V ELECTRICAL SYSTEM
Supplying, laying and handing over of following sizes under ground RCC pipe Class NP-
2 with coller jointed with stiff mixture of cement mortar in the proportion of 1:2.
completed as required & getting out the excavated soil and then returning the soil as
1.0 required in layers not exceeding 20 cm in depth including consolidating each
deposited layer by ramming, watering etc. and disposal of surplus excavated soil as
directed outside the site to the approved dumping ground.

150 mm dia.
a) Base Rate of Pipe only = Rs. 190/- F.O.R. Site excluding GST Metre 164.00 164.00 -
200 mm dia.
b) Base Rate of Pipe only = Rs. 250/- F.O.R. Site excluding GST Metre 33.00 33.00 -
- - -
Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete
with fitting and cutting, jointing etc. in the existing trench, & getting out the excavated
soil and then returning the soil as required in layers not exceeding 20 cm in depth
2.0 including consolidating each deposited layer by ramming, watering etc. and disposal of
surplus excavated soil as directed outside the site to the approved dumping ground
complete in all respect.
- - -
90 mm dia (OD-90 mm & ID-76 mm nominal)
a) Base Rate of Pipe only = Rs. 70/- F.O.R. Site excluding GST Metre R/O R/O -
120 mm dia (OD/103mm ID)
b) Base Rate of Pipe only = Rs. 90/- F.O.R. Site excluding GST Metre 818.00 818.00 -
200 mm dia (OD/175mm ID)
c) Base Rate of Pipe only = Rs. 150/- F.O.R. Site excluding GST Metre 11.00 11.00 -
- - -
Providing, Constructing, making and handing over brick masonary manhole, 230 mm
thick brick wall in mortar 1:5 (1 cement : 5 coarse sand) R.C.C. cover fixing with 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 100
mm thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 20 mm nominal size) finished with floating coat of neat cement and making
3.0 channels in cement concrete 1:2:4: (1 cement:2 coarse sand:4 graded stone aggregate
20mm nominal size ) finished with floating coat of neat cement complete as per
stadard design.

- - -
Inside size 45 x 45 cm and 45 cm deep incuding SFRC cover with frame (Heavy duty)
a) with FPS brick class desination 75. Each 46.00 46.00 -
- - -
Inside size 45 x 45 cm and 75 cm deep incuding SFRC cover with frame (Heavy duty)
b) with FPS brick class desination 75. Each 25.00 25.00 -

TOTAL C/F TO SUMMARY ### - - - -


G.TOTAL ### - -

12 of 12