Solis Datasheet Solis - (100-125) K-5G LKA V2,0 202412
Solis Datasheet Solis - (100-125) K-5G LKA V2,0 202412
Solis-(100-125)K-5G
Efficient Safe
• 10 MPPTs, max. efficiency 99.0% • AFCI protection, proactively reduces fire risk
• > 150% DC/AC ratio • Built-in PID recovery for better module
• Compatible with bifacial modules • Overvoltage load reduction and leakage current
suppression technology, low failure rate
Smart Economic
• Night SVG function • Power line communication (PLC) (optional)
• Intelligent string monitoring, smart I-V curve scan • DC side supports "Y" connector
Models:
Solis-100K-5G
Solis-110K-5G
Solis-125K-HV-5G
360º View
www.solisinverters.com
DATASHEET Solis-(100-125)K-5G
Input DC
Max. input voltage 1100 V
Rated voltage 600 V 720 V
Start-up voltage 195 V
MPPT voltage range 180 - 1000 V
Max. input current 10 × 26 A
Max. short circuit current 10 × 40 A
MPPT number / Max. input strings number 10 / 20
Output AC
Rated output power 100 kW 110 kW 125 kW
Max. apparent output power 110 kVA 121 kVA 137.5 kVA
Max. output power 110 kW 121 kW 137.5 kW
Rated grid voltage 3/N/PE, 220 V / 380 V, 230 V / 400 V 3/PE, 480 V
Rated grid frequency 50 Hz / 60 Hz
Rated grid output current 152.0 A / 144.3 A 167.1 A / 158.8 A 150.4 A
Max. output current 167.1 A 183.8 A 165.4 A
Power factor > 0.99 (0.8 leading - 0.8 lagging)
THDi < 3%
Efficiency
Max. efficiency 98.7% 99.0%
EU efficiency 98.3% 98.5%
Protection
DC reverse-polarity protection Yes
Short circuit protection Yes
Output over current protection Yes
Surge protection DC Type II / AC Type II (AC Type I optional)
Grid monitoring Yes
Anti-islanding protection Yes
Temperature protection Yes
Strings monitoring Yes
I/V Curve scanning Yes
Integrated AFCI Yes (1)
Integrated PID recovery Optional
Integrated DC switch Yes
Integrated AC switch Optional
General Data
Dimensions (W × H × D) 1065 × 567 × 344.5 mm
Weight 91 kg
Topology Transformerless
Self-consumption (night) <2W
Operating ambient temperature range -30 ~ +60°C
Relative humidity 0 - 100%
Ingress protection IP66
Cooling concept Intelligent fan-cooling
Max. operation altitude 4000 m
VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99,
Grid connection standard
EN 50549-1/-2, RD 1699, TOR, UNE 206006, UNE 206007-1, CEI 0-21, IEC61727, DEWA
Safety / EMC standard IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4
Features
DC connection MC4 connector
AC connection OT terminal (max. 185 mm²)
Display LCD
Communication RS485, Optional: Wi-Fi, GPRS, PLC