10 Pile Foundation in Road Project
10 Pile Foundation in Road Project
CONSTRUCTION OF BORED
DEFINITION
PILE
Foundation system that TYPE OF PILE
transfers loads to a deeper ➢ R.C Square Pile
and competent soil layer ➢ Boredpiles
➢ Micropiles
➢ Caisson Piles
PILE CLASSIFICATION ➢ Treated Timber Piles
➢ Bakau Piles
• Friction Pile ➢ Pre-Stressed Concrete Spun Piles
• End Bearing Pile ➢ Steel Piles
ACCEPTANCE OF SETLEMENT
CRITERIA
CONSTRUCTION OF R.C Based on Standard Specification for
Road Works Section 10: Piling Works.
SQUARE PILE Unless otherwise specified the pile
tested shall be deemed to have failed
if:-
PILE DESIGN i. The residual settlement after
• Allowable Structural removal of the test load at
working load exceeds [(diameter
Capacity of pile or diagonal width for
• Allowable Geotechnical Pile Marking Pile Lifting Pile Fitting to non-circular pile /120) + 4]mm
Piling Machine
Capacity or 12.50mm whichever is the
lower value; or
ii. The total settlement under the
Working Load exceeds
12.50mm; or
iii. The total settlement under
twice the Working Load exceeds
38.0mm, or 10% of pile
diameter/width whichever is the
Pile Joining Pile Positioning
lower value