0% found this document useful (0 votes)
5 views5 pages

Schneider Electric TeSys-Giga-contactors LC1G185LSEA

The document provides a detailed datasheet for the TeSys Giga high power contactor (model LC1G185LSEA), which features specifications such as a 3-pole design, operational voltage up to 1000V AC, and a rated current of 185A at 440V AC-3. It includes information on the contactor's applications, electrical ratings, mechanical durability, environmental data, and installation guidelines. Additionally, it outlines compliance with various standards and certifications, as well as environmental sustainability efforts by Schneider Electric.

Uploaded by

Rendra Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views5 pages

Schneider Electric TeSys-Giga-contactors LC1G185LSEA

The document provides a detailed datasheet for the TeSys Giga high power contactor (model LC1G185LSEA), which features specifications such as a 3-pole design, operational voltage up to 1000V AC, and a rated current of 185A at 440V AC-3. It includes information on the contactor's applications, electrical ratings, mechanical durability, environmental data, and installation guidelines. Additionally, it outlines compliance with various standards and certifications, as well as environmental sustainability efforts by Schneider Electric.

Uploaded by

Rendra Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Product datasheet

Specifications

High power contactor, TeSys Giga,


3 pole (3NO), AC-3 <=440V 185A,
advanced version, 200…500V wide
band AC/DC coil
LC1G185LSEA

Main
Range TeSys

Range of product TeSys Giga

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Contactor

Device short name LC1G

Contactor application Power switching


Motor control

Utilisation category AC-1


AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8b
AC-8a
DC-1
DC-3
DC-5

Poles description 3P

[Ue] rated operational voltage <= 1000 V AC 50/60 Hz


<= 460 V DC

[Ie] rated operational current 305 A (at <40 °C) at <= 1000 V AC-1
185 A (at <60 °C) at <= 440 V AC-3

[Uc] control circuit voltage 200...500 V AC 50/60 Hz


200...500 V DC

Control circuit voltage limits Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)

Complementary
[Uimp] rated impulse withstand 8 kV
voltage
Overvoltage category III

Rated breaking capacity 1610 A at 440 V

[Icw] rated short-time withstand 1.5 kA - 10 s


current 0.92 kA - 30 s
0.74 kA - 1 min
0.5 kA - 3 min
0.4 kA - 10 min

Associated fuse rating 200 A aM at <= 440 V for motor


160 A aM at <= 690 V for motor
315 A gG at <= 690 V

Average impedance 0.00017 Ohm

Apr 21, 2025 1


[Ui] rated insulation voltage 1000 V

Power dissipation per pole 20 W AC-1 - Ith 305 A


6 W AC-3 - Ith 185 A

Compatibility code LC1G

Pole contact composition 3 NO

Auxiliary contact composition 1 NO + 1 NC

Motor power kW 55 kW at 230 V AC 50/60 Hz (AC-3e)


90 kW at 400 V AC 50/60 Hz (AC-3e)
90 kW at 415 V AC 50/60 Hz (AC-3e)
110 kW at 440 V AC 50/60 Hz (AC-3e)
110 kW at 500 V AC 50/60 Hz (AC-3e)
110 kW at 690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
55 kW at 230 V AC 50/60 Hz (AC-3)
90 kW at 400 V AC 50/60 Hz (AC-3)
90 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
55 kW at 230 V AC 50/60 Hz (AC-4)
90 kW at 400 V AC 50/60 Hz (AC-4)
90 kW at 415 V AC 50/60 Hz (AC-4)
100 kW at 440 V AC 50/60 Hz (AC-4)
110 kW at 500 V AC 50/60 Hz (AC-4)
110 kW at 690 V AC 50/60 Hz (AC-4)
75 kW at 1000 V AC 50/60 Hz (AC-4)

Motor power hp 50 hp at 200/208 V 60 Hz


60 hp at 230/240 V 60 Hz
125 hp at 460/480 V 60 Hz
150 hp at 575/600 V 60 Hz

Coil technology Built-in bidirectional peak limiting

Safety reliability level B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO
13849-1

Mechanical durability 8 Mcycles

inrush power in VA (50/60 Hz, AC) 295 VA

inrush power in W (DC) 215 W

hold-in power consumption in VA 13.0 VA


(50/60 Hz, AC)
hold-in power consumption in W 8.0 W
(DC)
Operating time 40...70 ms closing
15...50 ms opening

Maximum operating rate 600 cyc/h AC-3


600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4

Connections - terminals Power circuit: bar 2 - busbar cross section: 25 x 6 mm


Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable
end
Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable
end
Control circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end

Connection pitch 35 mm

Mounting support Plate

2 Apr 21, 2025


Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ

Product certifications CB Scheme


CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL

Tightening torque 18 N.m

Height 255 mm

Width 108 mm

Depth 193 mm

Net weight 4.1 kg

Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106

Ambient air temperature for -25…60 °C


operation
Ambient air temperature for -60…80 °C
storage
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed

Colour Dark grey

Protective treatment TH

Permissible ambient air -40…70 °C at Uc


temperature around the device

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 26.000 cm

Package 1 Width 17.500 cm

Package 1 Length 32.000 cm

Package 1 Weight 5.076 kg

Unit Type of Package 2 S06

Number of Units in Package 2 12

Package 2 Height 75.000 cm

Package 2 Width 60.000 cm

Package 2 Length 80.000 cm

Package 2 Weight 74.912 kg

Apr 21, 2025 3


Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 767

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Packaging

Packaging made with recycled cardboard Yes

Packaging without single use plastic No

EU RoHS Directive Compliant with Exemptions

SCIP Number 6fbdad13-bb7c-47d4-a6d6-d82dd6f54349

REACh Regulation REACh Declaration

Halogen content performance Halogen free plastic parts product

PVC free Yes

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

Take-back No

4 Apr 21, 2025


Product datasheet LC1G185LSEA

Installation

Installation Videos

TeSys Giga - How to install the auxiliary contact block


TeSys Giga - How to install and remove remote wear diagnosis module
TeSys Giga - How to install mechanical interlock kit
TeSys Giga - How to replace control module
TeSys Giga - How to replace switching modules
TeSys Giga - How to assemble reverser solution
TeSys Giga - How to assemble change-over solution
TeSys Giga - How to assemble star-delta starter solution New

Apr 21, 2025 5

You might also like