A-1 - ULFM Fire Hydrants
A-1 - ULFM Fire Hydrants
SECTION
SUPER CENTURION®
FIRE HYDRANT
A-1
FIRE PROTECTION PRODUCTS Rev. 8-19
Shaded area indicates change
❏ Pressure Ratings – standard max. working sealed and threaded in place, hose and
pressure 350 psig (2400 kPa/24 barg): Test pumper nozzles are easily replaced.
pressure 700 psig (4800 kPa/48 barg). Securely retained by stainless steel locks.
❏ Anti-Friction Washer – Acetal washer - ❏ Electro-Galvanized Bolts and Nuts –
helps assure easy operation for life of provide corrosion protection.
the hydrant.
❏ Non-Kinking Chains – heavy duty and
❏ Hold-Down Nut – designed to discourage securely attached to hydrant. Special loops
unauthorized removal of parts. Integral permit nozzle caps to turn freely.
weather seal is UV resistant and protects ❏ Bury Depth Tag – Attached to the chain,
operating nut from freezing. O-ring below provides instant bury information.
weather seal provides second level of
protection again water entry into bonnet. ❏ Bronze Seat Ring – threaded into BRONZE
DRAIN RING and O-ring sealed. Easily
❏ Oil Filler Plug – permits quick check of oil removed or installed from above ground. Double
level and oil to be added if necessary without drain openings are force flushed each time
bonnet removal. hydrant is opened or closed, keeping them open
❏ Sealed Oil Reservoir – O-ring sealed for effective barrel drainage. Bronze drain valves
to prevent leakage. Factory filled with FDA are integral parts of main valve assembly.
approved oil that remains liquid year around. ❏ Patented, Reversible, Encapsulated,
Unique design automatically lubricates stem Compression-Type Main Valve – closes with
threads and bearing surfaces each time pressure for positive seal. Rubber material
hydrant is opened. has long service life, yet is reversible providing
❏ Stems – coated for corrosion resistance a convenient spare in place.
❏ Stainless Steel Stem Coupling – pulls free if ❏ Sealed Lower Stem Threads – protected
hydrant is hit by a vehicle preventing damage from corrosion for easier disassembly.
to stem and main valve. Coupling will not break Mueller HP® Epoxy Coated cap nut with
into pieces that could drop into lower barrel rubber gasket and stainless steel lock washer,
and affect valve operation. Top of lower stem shields threads from water.
is below top of lower barrel so a tire cannot ❏ Shoe Designed for Maximum Flow and Easy
depress it and open main valve. Reusable clip Installation – smooth transitional contours,
is easy to use. Repair is easy and economical. extended neck and integral anti-rotation pads
❏ Traffic Flange – breaks cleanly to help that allow use of standard tee-head bolts. Shoe
prevent traffic damage, yet strong enough to interior is covered with Mueller HP® Epoxy
withstand normal handling. Allows economical coating, creating a tough corrosion-resistant
repair, adding extension section, rotation or barrier to chemicals, physical impact and
changing of upper barrel without digging or electrical currents. Integral blocking pads on
water shut-off. bottom and back. Integral stem stop.
❏ Bronze Upper Valve Plate – conical shape ❏ Certified Performance – meets or
for smooth efficient flow. exceeds requirements of ANSI/AWWA
C502 Standard, and UL 246 and FM 1510
❏ Drain Valve Fittings – specially designed, specifications. Certified to ANSI/NSF
long-life facings provide effective sealing. 61/372.
❏ O-ring Seals at Bonnet, Ground, and ❏ 10-Year Limited Warranty – assured
Shoe Flanges – for better leak resistance, reliability (see separate Mueller Warranty
easier maintenance. document for terms).
❏ Full Flow Openings – large radius hose ❏ Security Options – selection of options
and pumper nozzle openings produce low to secure hydrant against unauthorized
friction loss, superior performance. operation or access to hydrant interior.
Modern Centurion® Style
❏ Field Replaceable Nozzles – O-ring with similar features
available. See page
A-1-3 for ratings.
A-1
Shaded area indicates change
FIRE PROTECTION PRODUCTS
www.muellercompany.com • [email protected]
Page A-1-2
UL / FM
SECTION
SUPER CENTURION®
& MODERN CENTURION® A-1
FIRE HYDRANTS
FIRE PROTECTION PRODUCTS Rev. 8-19
Shaded area indicates change
Super Centurion:
* Standard Working Pressure: 350 p.s.i. (2400 kPa/24 barg) - 700 p.s.i. (4800 kPa/48 barg) Test Pressure.
* Optional Working Pressure: 250 p.s.i. (1725 kPa/17 barg) - 500 p.s.i. (3450 kPa/35 barg) Test Pressure.
Modern Centurion:
* Standard Working Pressure: 175 p.s.i. (1200 kPa/12 barg) - 350 p.s.i. (2600 kPa/26 barg) Test Pressure.
Hydrant bury lengths are beginning with 1'-6"; deeper buries available in 6" increments.
Super Centurion Super Centurion with Option 370 Hose Gate Valves Modern Centurion
The Storz connection allows the fire department to connect its pumper hose to the
hydrant with a quick, quarter-turn action. The action is fast and smooth so firefighters
can get to their tasks quickly without the thread alignment, cross threading, or
leakage problems sometimes associated with threaded connections.
The Storz option is available for 4" or 5" pumper nozzles on any Super Centurion,
or Modern hydrants. Mueller hydrants retain their UL Approval, FM Listing, AWWA
Compliance and published pressure rating when ordered with the Storz option.
Hydrants are also compliant with NFPA 1963.
When ordering the integral Storz pumper nozzle, it is no longer necessary to provide
an option number on the order. On the order, state the 'Storz' size, and locking or
non-locking caps.
Storz Adaptors
Mueller also offers a 5" Storz adaptor for connection to 4-1/2" NST nozzles. Mueller
Storz adaptors feature the same caps used on the integral Storz nozzle and meet
the requirements of NFPA 1963. Mueller Storz adaptors are rated for 250 psi oper-
ating pressure.
INDEPENDENT HOSE
GATE VALVES
A-1
FIRE PROTECTION PRODUCTS Rev. 9-17
Shaded area indicates change
Iron Body: Bronze Mounted Type with Nozzle Cap and Chain
These hose gate valves are available for both Super Centurion® and Modern Centurion® fire hydrants. When ordering the
A-373 valve, the following items are also necessary.
Iron Body: Bronze Mounted Type with Nozzle Cap and Chain
Page A-1-5
UL / FM
SECTION
Bonnet Repair Kit Bonnet Repair Kit consists of: Main Valve Repair Kit Main Valve Repair Kit consists of:
• (1) Weather seal • (1) Top seat O-rings
• (1) Hold down nut O-rings • (1) Bottom seat O-rings
• (1) Bonnet O-rings • (1) Main valve (reversible)
• (1) Bonnet/Upper barrel O-ring • (1) Lower valve plate (reversible)
• (1) Anti-friction washer • (1) Cap nut seals
• (1) Bonnet flange gasket • (1) Bronze seat ring
• (2) Stem O-rings • (1) Instruction sheet
• (1) 10.5 oz. Hydrant lubricating oil
• (1) Instruction sheet
Page A-1-6
UL / FM
SECTION
FIRE HYDRANT
ACCESSORIES
A-1
FIRE PROTECTION PRODUCTS Rev. 8-19
Shaded area indicates change
Page A-1-7
UL / FM
SECTION
* Pre-1997 models may be upgraded to use the reverible main valve by also replacing the lower valve plate with the 1997 model.
** For Super Centurion 350 Hydrant, A-6 is a roller thrust bearing, Steel.
Page A-1-9
UL / FM
SECTION
32"
24"
1-5/8"
Page A-1-10
UL / FM
SECTION
A-403 SUPER CENTURION
FIRE HYDRANT A-1
REPLACEMENT PARTS
FIRE PROTECTION PRODUCTS Rev. 8-19
Shaded area indicates change
Page A-1-11
UL / FM
SECTION
5 1/4" UL/FM Mueller® Super Centurion Monitor Fire Hydrant replacement parts
A-1
A-3
A-4
A-2
A-5 A-6
A-7
A-8 A-9
A-14
A-13 A-10
A-15
A-44
A-45
A-12
A-16
A-17
A-49
A-11
A-22
A-48
A-24
A-25
A-26
A-28
A-27
A-23 A-46
A-30
A-29
A-32
A-34
A-33
A-31
A-47
A-52
A-38
A-36
A-39 A-37
A-35
A-40 A-41
A-43
A-42
A-51
5 1/4" UL/FM Mueller® Super Centurion Monitor Fire Hydrant replacement parts
Catalog Part
Description Material Material Standard
Number
A-1 Operating Nut Bronze ASTM B62
A-36 Upper Valve Plate (includes A-34 and A-35) Bronze ASTM B584
Page A-1-13
UL / FM
SECTION
A-55Housing
A-55 Housing
A-52 Operating Nut
A-54 Hold Down Nut
A-3 Hold Down Nut O-Ring - Inside
A-53 Weather Cap
A-5 Hold Down Nut O-Ring - Outside
A-6 Anti-Friction Washer
A-56 Housing Bolts
A-57 Housing Top O-Ring
A-13 Nozzle Lock
A-14 Pumper Nozzle
A-17 Pumper Nozzle Cap
A-15 Pumper Nozzle Cap Gasket
A-16 Pumper Nozzle O-Ring
A-7 Oil Filler Plug
A-23 Chain Connector Hook
A-21 Hose Nozzle Cap
A-18 Hose Nozzle
A-19 Hose Nozzle Cap Gasket
A-20 Hose Nozzle O-Ring
A-22 Chain
A-12 Stem O-Rings
A-58 Upper Stem
A-59 Upper Barrel
A-26 Traffic Flange Bolt & Nut
A-27 Traffic Flange Gasket
A-28 Traffic Flange
A-25 Stem Coupling
A-29 Cotter Pin
A-30 Clevis Pin
A-32 Lower Barrel
A-31 Lower Stem
A-33 Stem Pin
A-34 Drain Valve Facing
A-35 Drain Valve Facing Screw
A-36 Upper Valve Plate
A-37 Show Bolt & Nut
A-43 Seat Ring
A-38 Drain Ring Housing Gasket
A-39 Seat Ring Top O-Ring
A-40 Drain Ring
* Pre-1997 models may be upgraded to use the reversible main valve by also replacing the lower valve plate with the 1997 model.
** 6" MJ shoe is Ductile Iron, ASTM A536
Page A-1-15
UL / FM
SECTION
E DIMENSIONS
A A B C D E F G
2-1/2" 9" 5" 8-3/16" 7/8" 7-3/8" 5-5/8"
D G
F
DIMENSIONS
A B C D G
A
2-1/2" 9" 5" 8-3/16" 5-5/8"
D G
Page A-1-16
UL / FM
SECTION
A-1
4-1/2" and 5-1/4" (1965-1979)
CHATTANOOGA UL/FM
HYDRANT
FIRE PROTECTION PRODUCTS REPLACEMENT PARTS
Rev. 10-17
Shaded area indicates change
Catalog Part
Description Material Material Standard
Number
H-1 Oil Screw Bronze ASTM B36
H-2 Operating Nut Bronze ASTM B62
H-3 Weather Cap Bronze ASTM B62
H-4 Hold Down Nut Bronze ASTM B62
H-5 Oiler Steel -
H-16 Hose Nozzle Cap Cast Iron ASTM A126 Class B
H-17 Hose Nozzle Gasket Rubber ASTM D2000
H-24 Test Plug Brass -
H-26 Barrel Gasket Rubber ASTM D2000
H-28 Stem Top Section Bronze ASTM B584
H-29 Upper Stem Pin Bronze ASTM B21
H-32 Nozzle Cap Chain Steel -
H-35 Stem Steel ASTM A576 Grade 1117
H-36 Upper Valve Plate Bronze ASTM B584
H-37 Drain Valve Facing Screw Bronze ASTM A276
H-39 Seat Ring Bronze ASTM B584
H-40 Lower Barrel Cast Iron ASTM A126 Class B
H-41 Shoe Gasket Rubber ASTM D2000
H-42 Shoe Bolt and Nut Steel SAE J429
H-43 Metallic Gasket Copper-fiber -
H-44 Main Valve Rubber ASTM D2000
H-45 Lower Valve Plate Cast Iron ASTM A126 Class B
H-46 Valve Plate Nut Bronze ASTM B584
H-47 Shoe Cast Iron ASTM A126 Class B
H-49 Drain Valve Facing Leather -
H-50 Cap Nut Bronze ASTM B584
H-70 Hose Nozzle Bronze ASTM B584
H-93 O-ring Seal Rubber ASTM D2000
H-150 Bonnet with Bushing Cast Iron ASTM A126 Class B
H-151 Bonnet Bolt and Nut Steel SAE J429
H-152 Upper Barrel Cast Iron ASTM A126 Class B
H-153 Barrel Bolt and Nut Steel SAE J429
H-154 Bonnet Gasket Rubber ASTM D2000
Upper Barrel for Hose Gates
H-155 Cast Iron ASTM A126 Class B
- Less Hose Gates
Size of DIMENSIONS
Hydrant A B C D E F
4-1/2" 31-1/4" 17-3/4" 6" 7" 1-3/8" See page
5-1/4" 33-1/4" 18" 7" 7-7/8" 1-5/8" A-1-4
Note: All 5-1/4" hydrants manufactured since 1965 are of the above design. To
order repair parts for hydrants dated prior to 1965 see page A-1-18
Catalog Part
Description Material Material Standard
Number
H-1 Oil Screw Bronze ASTM B36
H-2 Operating Nut Bronze ASTM B62
H-3 Weather Cap Bronze ASTM B62
H-4 Hold Down Nut Bronze ASTM B62
H-5 Oiler Steel -
H-16 Hose Nozzle Cap Cast Iron ASTM A126 Class B
H-17 Hose Nozzle Gasket Rubber ASTM D2000
H-24 Test Plug Brass -
H-26 Barrel Gasket Rubber ASTM D2000
H-28 Stem Top Section Bronze ASTMB584
H-29 Upper Stem Pin Bronze ASTM B21
H-32 Nozzle Cap Chain Steel -
H-35 Stem Steel ASTM A576 or A108
H-36 Upper Valve Plate Bronze ASTM B584
H-37 Drain Valve Facing Screw Bronze ASTM A276
H-39 Seat Ring Bronze ASTM B584
H-40 Lower Barrel Cast Iron ASTM A126 Class B
H-41 Shoe Gasket Rubber ASTM D2000
H-42 Shoe Bolt and Nut Steel SAE J429
H-43 Metallic Gasket Copper-fiber -
H-44 Main Valve Rubber ASTM D2000
H-45 Lower Valve Plate Cast Iron ASTM A126 Class B
H-46 Valve Plate Nut Bronze ASTM B584
H-47 Shoe Cast Iron ASTM A126 Class B
H-49 Drain Valve Facing Leather -
H-50 Cap Nut Bronze ASTM B584
H-93 O-ring Seal Rubber ASTM D2000
DIMENSIONS
Size of Hydrant
A B C D E
5-1/4" 30-7/8" 17-1/4" 7" 8-1/8" 3-3/8"
OPTIONAL
OPERATING NUT
TEST PLUG
(ENLARGED 4 XS)
STEM
UPPER BARREL
BARREL GASKET
BARREL NUT
UPPER VALVE
SHOE BOLT PLATE
DRAIN VALVE
LOWER BARREL
SCREW
DRAIN VALVE
FACING
SHOE GASKET
SEAT RING
METALLIC
GASKET
LOWER VALVE
SHOE PLATE
VALVE NUT
CAP NUT
ORDERING
INSTRUCTIONS
A-1
FIRE PROTECTION PRODUCTS Rev. 9-05
Shaded area indicates change
* Manufacturers standard
NOTE: All dimensions are in inches and all dimensional data and tolerances are in accord with ANSI B26.
Page A-1-21
UL / FM
SECTION
www.muellercompany.com • [email protected]
Page A-1-22