The POLYCAB MC-4 Copper Conductor XLPE Insulated Unarmored Power Cable is designed for AC and DC systems with voltage ratings up to 1100V and 1500V respectively. It features a stranded copper conductor, XLPE insulation, and PVC outer sheath, complying with IS 7098-Part 1 standards. The cable is suitable for various applications and has specific electrical characteristics including current carrying capacities and maximum DC conductor resistance.

Uploaded by

Sameer Shaikh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views2 pages

4 core polycab 6 sq mm data sheet

The POLYCAB MC-4 Copper Conductor XLPE Insulated Unarmored Power Cable is designed for AC and DC systems with voltage ratings up to 1100V and 1500V respectively. It features a stranded copper conductor, XLPE insulation, and PVC outer sheath, complying with IS 7098-Part 1 standards. The cable is suitable for various applications and has specific electrical characteristics including current carrying capacities and maximum DC conductor resistance.

Uploaded by

Sameer Shaikh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

POLYCAB MC-4 COPPER CONDUCTOR XLPE INSULATED UNARMORED

POWER CABLE (2XY) 650/1100V AC - IS 7098-Part 1

Stranded Copper Conductor

XLPE Insulation

Inner Sheath

Extruded PVC Type ST2 Outer Sheath

Cross Section

APPLICATION

POLYCAB 2XY MC-4, Stranded compacted copper conductor, XLPE insulated, and PVC sheathed
confirming to IS 7098-1 is suitable for AC single phase or three phase (earthed or unearthed) systems with
rated voltage up to and including 1100 V. This cable is also suitable for DC systems with rated voltage up to
and including 1500 V to earth.

VOLTAGE RATING STANDARD AND REFERENCES


650/1100 V IS 8130:2013
IS 5831:1984
IS 7098-1:1988

OPERATION TEMPERATURE COMPLIANCE


Max.: 90˚C Conductor resistance - IS 8130:2013
Short circuit temperature 250˚C Insulation resistance - IS 7098-1:1988
Flammability test - IEC 60332-1-2:2015

CORE IDENTIFICATION BENDING RADIUS


Red, Yellow, Blue & Black Fixed installation | 12 x Overall diameter

CONSTRUCTION
Stranded plain compacted/Non-Compacted copper
conductor as per IS 8130, class 1 & 2
Insulated with Cross Linked Polyethylene (XLPE) to IS 7098-1
Extruded inner sheath with PVC Type ST2/FRLS/FR/LSZH
Sheathed with Extruded PVC Type ST2/FRLS/FR/LSZH

OUR CERTIFICATION
ISO ISO ISO NABL ABS IRS
9001 14001 45001 060
POLYCAB MC-4 COPPER CONDUCTOR XLPE INSULATED UNARMORED
POWER CABLE (2XY) 650/1100V AC - IS 7098-Part 1

Weight & Dimension Data


Nominal Nominal Nominal
Overall Weight
cross- sectional Class of Thickness thickness
Product code Diameter (Approx.)
area conductor of Insulation of outer sheath

n x mm² mm mm mm kg/km

LVIS09CXUAY2004C004SA001S 4x4 Class 1 0.7 1.8 13.5 260


LVIS09CXUAY2004C006SA001S 4x6 Class 1 0.7 1.8 14.7 350
LVIS09CXUAY2004C004SA002S 4x4 Class 2 0.7 1.8 14.2 280
LVIS09CXUAY2004C006SA004S 4x6 Class 2 0.7 1.8 15.5 365
LVIS09CXUAY2004C010SA001S 4 x 10 Class 2 0.7 1.8 17.8 510
LVIS09CXUAY2004C016SA001S 4 x 16 Class 2 0.7 1.8 17.5 741
LVIS09CXUAY2004C025SA001S 4 x 25 Class 2 0.9 2 21 1140
LVIS09CXUAY2004C035SA001S 4 x 35 Class 2 0.9 2 23.5 1491
LVIS09CXUAY2004C050SA001S 4 x 50 Class 2 1 2 26 1957
LVIS09CXUAY2004C070SA001S 4 x 70 Class 2 1.1 2.2 30.5 2774
LVIS09CXUAY2004C095SA001S 4 x 95 Class 2 1.1 2.2 33.5 3714
LVIS09CXUAY2004C120SA001S 4 x 120 Class 2 1.2 2.4 37.5 4645
LVIS09CXUAY2004C150SA001S 4 x 150 Class 2 1.4 2.6 42 5719
LVIS09CXUAY2004C185SA001S 4 x 185 Class 2 1.6 2.8 46.5 7125
LVIS09CXUAY2004C240SA001S 4 x 240 Class 2 1.7 3 52.5 9253
LVIS09CXUAY2004C300SA001S 4 x 300 Class 2 1.8 3.2 58 11524

The above data is approximate & subject to manufacturing tolerance.

Electrical characteristics
Current carrying capacity and Maximum DC conductor resistance.

Nominal area Buried direct in In single Max. DC conductor


In air
of conductor the ground way Ducts resistance at 20˚C

mm² Amp. Amp. Amp. Ω/km

4 45 38 41 4.61
6 56 47 52 3.08
10 74 62 70 1.83
16 95 79 89 1.15
25 122 102 119 0.727
35 146 122 147 0.524
50 173 144 179 0.387
70 212 177 226 0.268
95 254 212 279 0.193
120 287 240 320 0.153
150 321 269 365 0.124
185 362 304 422 0.0991
240 418 352 500 0.0754
300 469 396 574 0.0601
400 528 447 662 0.047
Air Ambient temperature: 40˚C,

Ground ambient temperature: 30˚C,

The above table is in accordance with IS 3961(part 6):2016