0% found this document useful (0 votes)
4 views2 pages

Technical Specifications 10 Kva on Line Ups

The document outlines the technical specifications and pricing details for a 10 KVA On-Line UPS system, including requirements for installation, testing, and commissioning. It specifies the UPS and battery brands, operational parameters, protection features, and backup time requirements. Additionally, it includes a price bid section for various configurations of the UPS system with a warranty condition.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views2 pages

Technical Specifications 10 Kva on Line Ups

The document outlines the technical specifications and pricing details for a 10 KVA On-Line UPS system, including requirements for installation, testing, and commissioning. It specifies the UPS and battery brands, operational parameters, protection features, and backup time requirements. Additionally, it includes a price bid section for various configurations of the UPS system with a warranty condition.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TECHNICAL SPECIFICATIONS 10 KVA ON LINE UPS

Capacity/Rating 10 KVA
Make of UPS EATON/EMERSON/APC/SOCOMEC
Make of Batteries EXIDE/AMARON/HBL/PANASONIC
General UPS shall be free from workmanship defects, sharp edges,
nicks, scratches, burrs, etc. All fasteners shall be fixed
properly. The equipment shall be complete with all parts
and all parts shall be functional.
Technology Microprocessor based Digital Control, IGBT based, True
on line double conversion, AC to DC conversion and then
DC to AC.
Waveform Pure Sine wave
Input Voltage 110-270V
Input Frequency 45-55 Hz (Generator Compatible)
Input Power Factor > 0.90
Output Voltage 208V/220/230/240V AC -Selectable
Out Put Power Factor 0.9
Output Frequency 50Hz/60Hz +/- 0.05%
THD < 2% Linear Load and 5% Non Linear Load.
Inverter Efficiency > 92%
Crest Factor 3:1
Over Load On Batteries 105% - 125% for at least 120 sec, if overload exceeds UPS
shall go in Bypass mode and auto recover on removal of
load.
Paralleling Option for paralleling up to 4 Units.
By Pass Switches Built in Static/Automatic Bi-Directional Type
( Manual By Pass arrangement Not Acceptable)
Protection Input Over/Under Voltage, Output Overload, Short Circuit,
Battery Low/High, Battery reversed polarity, protection for
IGBT & thermal overload.
Display LCD.
Alarms Audible Alarms should be provided for Mains Fail, Battery
Low and Fault Conditions.
Operating Conditions 0-40 deg C, 0-90% RH maximum, non condensing audible
noise-50 dB at front 1 meter.
Cooling Air forced type
Soft ware support Novel Netware/UNIX/Windows NT/Solaris
Batteries SMF-VRLA type.
Back Up Time 60 mins on full load.
Minimum VAH Required 10800 (Bidders can choose battery capacity accordingly)
PRICE BID
Prices to be quoted inclusive of all taxes and duties and installation charges.
SL. DESCRIPTION Qty Make of Make of Rate
NO UPS Batteries (Rs.)
Offered Offered
1 Supply , Installation , testing & Commissioning of
10KVA On-Line UPS System, Single Phase Input &
Single Phase output complete with SMF-VRLA batteries
to provide backup time as per following requirements
and technical specifications including battery rack &
connecting loops with two years warranty on UPS &
batteries:
:

a) 30 mins on full load 1 no.

b) 60 mins on full load 1 no.


2 Supply , Installation , testing & Commissioning of 5
KVA On-Line UPS System, Single Phase Input & Single
Phase output complete with SMF-VRLA batteries to
provide backup time as per following requirements and
technical specifications including battery rack &
connecting loops with two years warranty on UPS &
batteries:

a) 30 mins on full load 1 no.

b) 60 mins on full load 1 no.

UPS Make: EATON/EMERSON/APC/NUMERIC/SOCOMEC


Battery Make: EXIDE/AMARON/HBL/PANASONIC.

Earnest Money Deposited CDR/FDR...............................DATED............................................

I/We have read all terms & conditions and filled bidder information page. All terms & conditions
are acceptable to us.

Name of Proprietor/Partner.............................................................................................................

Name of Bidder................................................................................................................................

Address of Bidder..........................................................................................................................

Signature of Bidder Seal of Bidder