0% found this document useful (0 votes)
66 views262 pages

LV3000H. 3000U Plus_User_Guide

The LV3000H/LV3000U Plus Fixed Mount Barcode Scanner User Guide provides comprehensive instructions on setup, features, and system settings for the scanner. It covers various connection methods, programming options, and detailed information on supported barcode symbologies. The guide is structured into chapters that facilitate easy navigation through installation, configuration, and operational guidelines.

Uploaded by

aguallan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views262 pages

LV3000H. 3000U Plus_User_Guide

The LV3000H/LV3000U Plus Fixed Mount Barcode Scanner User Guide provides comprehensive instructions on setup, features, and system settings for the scanner. It covers various connection methods, programming options, and detailed information on supported barcode symbologies. The guide is structured into chapters that facilitate easy navigation through installation, configuration, and operational guidelines.

Uploaded by

aguallan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 262

LV3000H/LV3000U Plus

Fixed Mount Barcode Scanner

User Guide
Table of Contents
Revision History .......................................................................................................................................................................- 3 -

Preface .......................................................................................................................................................................................... 1

Introduction ...................................................................................................................................................................... 1
Chapter Description ......................................................................................................................................................... 1
Explanation of Icons ......................................................................................................................................................... 2

Chapter 1 Getting Started ............................................................................................................................................................ 3

Introduction ...................................................................................................................................................................... 3
Features of the LV3000H..................................................................................................................................................... 3
Unpacking ........................................................................................................................................................................ 3
LV3000H Scanner ................................................................................................................................................................ 4
Data Port Pinout ............................................................................................................................................................... 5
Dimensions (unit: mm) ..................................................................................................................................................... 6
IR Triggering Range ......................................................................................................................................................... 7
Optics ............................................................................................................................................................................... 8
Connecting the LV3000H to a Host Device .......................................................................................................................... 9
Using USB Cable .................................................................................................................................................... 10
Using RS-232 Cable ............................................................................................................................................... 11
Scanning Instructions ..................................................................................................................................................... 12
Maintenance................................................................................................................................................................... 12

Chapter 2 System Settings ........................................................................................................................................................ 14

Introduction .................................................................................................................................................................... 14
Barcode Programming ............................................................................................................................................ 14
Command Programming ......................................................................................................................................... 14
Programming Barcode/ Programming Command/Function ............................................................................................ 15
Use of Programming Barcodes ...................................................................................................................................... 16
Illumination ..................................................................................................................................................................... 17
Aiming ............................................................................................................................................................................ 18
Good Read LED ............................................................................................................................................................. 18
Good Read LED Duration ....................................................................................................................................... 19
Power On Beep .............................................................................................................................................................. 20
Good Read Beep ........................................................................................................................................................... 20
Good Read Beep Duration ...................................................................................................................................... 21
Good Read Beep Frequency .................................................................................................................................. 22
Good Read Beep Volume ....................................................................................................................................... 23
Scan Mode ..................................................................................................................................................................... 24
Decode Session Timeout ............................................................................................................................................... 25
Image Stabilization Timeout (Sense Mode) .................................................................................................................... 26
Timeout between Decodes (Same Barcode) .................................................................................................................. 27
Sensitivity (Sense Mode) ............................................................................................................................................... 28
Trigger Commands......................................................................................................................................................... 29
Modify Start Scanning Command ........................................................................................................................... 29
Modify Stop Scanning Command ............................................................................................................................ 30
Scanning Preference ...................................................................................................................................................... 31
Decode Area .................................................................................................................................................................. 31
Image Flipping................................................................................................................................................................ 34
Bad Read Message ........................................................................................................................................................ 35
Set Bad Read Message .......................................................................................................................................... 35
Default Settings .............................................................................................................................................................. 36
Factory Defaults ...................................................................................................................................................... 36
Custom Defaults ..................................................................................................................................................... 36

Chapter 3 RS-232 Interface ........................................................................................................................................................ 38

Introduction .................................................................................................................................................................... 38
Baud Rate ............................................................................................................................................................... 39
Parity Check............................................................................................................................................................ 40
Data Bit ................................................................................................................................................................... 41
Stop Bit ................................................................................................................................................................... 41
Hardware Auto Flow Control ................................................................................................................................... 42

Chapter 4 USB Interface ............................................................................................................................................................ 43

Introduction .................................................................................................................................................................... 43
USB HID Keyboard ........................................................................................................................................................ 44
USB Country Keyboard Types ................................................................................................................................ 45
Beep on Unknown Character .................................................................................................................................. 49
Emulate ALT+Keypad ............................................................................................................................................. 50
Code Page .............................................................................................................................................................. 51
Unicode Encoding ................................................................................................................................................... 52
Function Key Mapping ............................................................................................................................................ 53
ASCII Function Key Mapping Table ........................................................................................................................ 54
ASCII Function Key Mapping Table (Continued) ..................................................................................................... 55
Inter-Keystroke Delay ............................................................................................................................................. 56
Caps Lock ............................................................................................................................................................... 56
Convert Case .......................................................................................................................................................... 57
Emulate Numeric Keypad ....................................................................................................................................... 58
Fast Mode ............................................................................................................................................................... 60
Polling Rate............................................................................................................................................................. 61
USB CDC ....................................................................................................................................................................... 63
HID POS (POS HID Barcode Scanner) .......................................................................................................................... 64
Introduction ............................................................................................................................................................. 64
Access the Scanner with Your Program .................................................................................................................. 64
Acquire Scanned Data ............................................................................................................................................ 65
Send Command to the Scanner .............................................................................................................................. 65
IBM SurePOS (Tabletop) ................................................................................................................................................ 66
IBM SurePOS (Handheld) .............................................................................................................................................. 66
VID/PID .......................................................................................................................................................................... 66

Chapter 5 Symbologies.............................................................................................................................................................. 67

Introduction .................................................................................................................................................................... 67
Global Settings ............................................................................................................................................................... 67
Enable/Disable All Symbologies .............................................................................................................................. 67
Enable/Disable 1D Symbologies ............................................................................................................................. 67
Enable/Disable 2D Symbologies ............................................................................................................................. 68
Enable Postal Symbologies .................................................................................................................................... 68
1D Twin Code ......................................................................................................................................................... 69
Code 128 ....................................................................................................................................................................... 70
Restore Factory Defaults ........................................................................................................................................ 70
Enable/Disable Code 128 ....................................................................................................................................... 70
Set Length Range for Code 128 ............................................................................................................................. 71
EAN-8 ............................................................................................................................................................................ 72
Restore Factory Defaults ........................................................................................................................................ 72
Enable/Disable EAN-8 ............................................................................................................................................ 72
Transmit Check Character ...................................................................................................................................... 72
2-Digit Add-On Code ............................................................................................................................................... 73
5-Digit Add-On Code ............................................................................................................................................... 74
Convert EAN-8 to EAN-13 ...................................................................................................................................... 75
EAN-13 .......................................................................................................................................................................... 76
Restore Factory Defaults ........................................................................................................................................ 76
Enable/Disable EAN-13 .......................................................................................................................................... 76
Transmit Check Character ...................................................................................................................................... 77
2-Digit Add-On Code ............................................................................................................................................... 77
5-Digit Add-On Code ............................................................................................................................................... 78
UPC-E ............................................................................................................................................................................ 79
Restore Factory Defaults ........................................................................................................................................ 79
Enable/Disable UPC-E ............................................................................................................................................ 79
Transmit Check Character ...................................................................................................................................... 79
2-Digit Add-On Code ............................................................................................................................................... 80
5-Digit Add-On Code ............................................................................................................................................... 81
Transmit Preamble Character ................................................................................................................................. 82
Convert UPC-E to UPC-A ....................................................................................................................................... 82
UPC-A ............................................................................................................................................................................ 83
Restore Factory Defaults ........................................................................................................................................ 83
Enable/Disable UPC-A ............................................................................................................................................ 83
Transmit Check Character ...................................................................................................................................... 83
2-Digit Add-On Code ............................................................................................................................................... 84
5-Digit Add-On Code ............................................................................................................................................... 85
Transmit Preamble Character ................................................................................................................................. 86
Coupon .......................................................................................................................................................................... 87
UPC-A/EAN-13 with Extended Coupon Code ......................................................................................................... 87
Coupon GS1 Databar Output .................................................................................................................................. 88
Interleaved 2 of 5 ........................................................................................................................................................... 89
Restore Factory Defaults ........................................................................................................................................ 89
Enable/Disable Interleaved 2 of 5 ........................................................................................................................... 89
Set Length Range for Interleaved 2 of 5 ................................................................................................................. 90
Check Character Verification................................................................................................................................... 91
ITF-14 ............................................................................................................................................................................ 92
Restore Factory Defaults ........................................................................................................................................ 92
Enable/Disable ITF-14 ............................................................................................................................................ 92
ITF-6 .............................................................................................................................................................................. 93
Restore Factory Defaults ........................................................................................................................................ 93
Enable/Disable ITF-6 .............................................................................................................................................. 93
Matrix 2 of 5 ................................................................................................................................................................... 94
Restore Factory Defaults ........................................................................................................................................ 94
Enable/Disable Matrix 2 of 5 ................................................................................................................................... 94
Set Length Range for Matrix 2 of 5 ......................................................................................................................... 95
Check Character Verification................................................................................................................................... 96
Code 39 ......................................................................................................................................................................... 97
Restore Factory Defaults ........................................................................................................................................ 97
Enable/Disable Code 39 ......................................................................................................................................... 97
Set Length Range for Code 39 ............................................................................................................................... 98
Check Character Verification................................................................................................................................... 99
Transmit Start/Stop Character............................................................................................................................... 100
Enable/Disable Code 39 Full ASCII ...................................................................................................................... 100
Enable/Disable Code 32 (Italian Pharma Code) ................................................................................................... 101
Code 32 Prefix ...................................................................................................................................................... 101
Transmit Code 32 Start/Stop Character ................................................................................................................ 102
Transmit Code 32 Check Character ...................................................................................................................... 102
Codabar ....................................................................................................................................................................... 103
Restore Factory Defaults ...................................................................................................................................... 103
Enable/Disable Codabar ....................................................................................................................................... 103
Set Length Range for Codabar ............................................................................................................................. 104
Check Character Verification................................................................................................................................. 105
Start/Stop Character ............................................................................................................................................. 106
Code 93 ....................................................................................................................................................................... 107
Restore Factory Defaults ...................................................................................................................................... 107
Enable/Disable Code 93 ....................................................................................................................................... 107
Set Length Range for Code 93 ............................................................................................................................. 108
Check Character Verification................................................................................................................................. 109
China Post 25............................................................................................................................................................... 110
Restore Factory Defaults ...................................................................................................................................... 110
Enable/Disable China Post 25 .............................................................................................................................. 110
Set Length Range for China Post 25 .....................................................................................................................111
Check Character Verification................................................................................................................................. 112
GS1-128 (UCC/EAN-128) ............................................................................................................................................ 113
Restore Factory Defaults ...................................................................................................................................... 113
Enable/Disable GS1-128....................................................................................................................................... 113
Set Length Range for GS1-128............................................................................................................................. 114
GS1 Databar (RSS) ..................................................................................................................................................... 115
Restore Factory Defaults ...................................................................................................................................... 115
Enable/Disable GS1 Databar ................................................................................................................................ 115
Transmit Application Identifier “01” ........................................................................................................................ 115
GS1 Composite (EAN·UCC Composite) ...................................................................................................................... 116
Restore Factory Defaults ...................................................................................................................................... 116
Enable/Disable GS1 Composite............................................................................................................................ 116
Enable/Disable UPC/EAN Composite ................................................................................................................... 116
Code 11 ........................................................................................................................................................................ 117
Restore Factory Defaults ...................................................................................................................................... 117
Enable/Disable Code 11........................................................................................................................................ 117
Set Length Range for Code 11 .............................................................................................................................. 118
Check Character Verification................................................................................................................................. 119
Transmit Check Character .................................................................................................................................... 120
ISBN ............................................................................................................................................................................. 121
Restore Factory Defaults ...................................................................................................................................... 121
Enable/Disable ISBN ............................................................................................................................................ 121
Set ISBN Format ................................................................................................................................................... 122
ISSN ............................................................................................................................................................................. 123
Restore Factory Defaults ...................................................................................................................................... 123
Enable/Disable ISSN ............................................................................................................................................ 123
Industrial 25.................................................................................................................................................................. 124
Restore Factory Defaults ...................................................................................................................................... 124
Enable/Disable Industrial 25 ................................................................................................................................. 124
Set Length Range for Industrial 25 ....................................................................................................................... 125
Check Character Verification................................................................................................................................. 126
Standard 25.................................................................................................................................................................. 127
Restore Factory Defaults ...................................................................................................................................... 127
Enable/Disable Standard 25 ................................................................................................................................. 127
Set Length Range for Standard 25 ....................................................................................................................... 128
Check Character Verification................................................................................................................................. 129
Plessey ........................................................................................................................................................................ 130
Restore Factory Defaults ...................................................................................................................................... 130
Enable/Disable Plessey ........................................................................................................................................ 130
Set Length Range for Plessey .............................................................................................................................. 131
Check Character Verification................................................................................................................................. 132
MSI-Plessey ................................................................................................................................................................. 133
Restore Factory Defaults ...................................................................................................................................... 133
Enable/Disable MSI-Plessey ................................................................................................................................. 133
Set Length Range for MSI-Plessey ....................................................................................................................... 134
Check Character Verification................................................................................................................................. 135
Transmit Check Character .................................................................................................................................... 136
AIM 128 ........................................................................................................................................................................ 137
Restore Factory Defaults ...................................................................................................................................... 137
Enable/Disable AIM 128 ........................................................................................................................................ 137
Set Length Range for AIM 128 .............................................................................................................................. 138
ISBT 128 ...................................................................................................................................................................... 139
Restore Factory Defaults ...................................................................................................................................... 139
Enable/Disable ISBT 128 ...................................................................................................................................... 139
Code 49 ....................................................................................................................................................................... 140
Restore Factory Defaults ...................................................................................................................................... 140
Enable/Disable Code 49 ....................................................................................................................................... 140
Set Length Range for Code 49 ............................................................................................................................. 141
Code 16K ..................................................................................................................................................................... 142
Restore Factory Defaults ...................................................................................................................................... 142
Enable/Disable Code 16K ..................................................................................................................................... 142
Set Length Range for Code 16K ........................................................................................................................... 143
PDF417 ........................................................................................................................................................................ 144
Restore Factory Defaults ...................................................................................................................................... 144
Enable/Disable PDF417 ........................................................................................................................................ 144
Set Length Range for PDF417 .............................................................................................................................. 145
PDF417 Twin Code ............................................................................................................................................... 146
PDF417 Inverse .................................................................................................................................................... 147
Character Encoding .............................................................................................................................................. 147
PDF417 ECI Output .............................................................................................................................................. 148
Micro PDF417 .............................................................................................................................................................. 149
Restore Factory Defaults ...................................................................................................................................... 149
Enable/Disable Micro PDF417 .............................................................................................................................. 149
Set Length Range for Micro PDF417 .................................................................................................................... 150
QR Code ...................................................................................................................................................................... 151
Restore Factory Defaults ...................................................................................................................................... 151
Enable/Disable QR Code ...................................................................................................................................... 151
Set Length Range for QR Code ............................................................................................................................ 152
QR Twin Code ....................................................................................................................................................... 153
QR Inverse ............................................................................................................................................................ 154
Character Encoding .............................................................................................................................................. 154
QR ECI Output ...................................................................................................................................................... 155
Micro QR Code ............................................................................................................................................................ 156
Restore Factory Defaults ...................................................................................................................................... 156
Enable/Disable Micro QR ...................................................................................................................................... 156
Set Length Range for Micro QR ............................................................................................................................ 157
Aztec ............................................................................................................................................................................ 158
Restore Factory Defaults ...................................................................................................................................... 158
Enable/Disable Aztec Code................................................................................................................................... 158
Set Length Range for Aztec Code ......................................................................................................................... 159
Read Multi-barcodes on an Image ........................................................................................................................ 160
Set the Number of Barcodes ................................................................................................................................. 161
Character Encoding .............................................................................................................................................. 162
Aztec ECI Output .................................................................................................................................................. 162
Data Matrix ................................................................................................................................................................... 163
Restore Factory Defaults ...................................................................................................................................... 163
Enable/Disable Data Matrix................................................................................................................................... 163
Set Length Range for Data Matrix ......................................................................................................................... 164
Data Matrix Twin Code .......................................................................................................................................... 165
Rectangular Barcode ............................................................................................................................................ 166
Data Matrix Inverse ............................................................................................................................................... 166
Character Encoding .............................................................................................................................................. 167
Data Matrix ECI Output ......................................................................................................................................... 167
Maxicode ...................................................................................................................................................................... 168
Restore Factory Defaults ...................................................................................................................................... 168
Enable/Disable Maxicode...................................................................................................................................... 168
Set Length Range for Maxicode............................................................................................................................ 169
Chinese Sensible Code ................................................................................................................................................ 170
Restore Factory Defaults ...................................................................................................................................... 170
Enable/Disable Chinese Sensible Code ............................................................................................................... 170
Set Length Range for Chinese Sensible Code...................................................................................................... 171
Chinese Sensible Twin Code ................................................................................................................................ 172
Chinese Sensible Code Inverse ............................................................................................................................ 173
GM Code ...................................................................................................................................................................... 174
Restore Factory Defaults ...................................................................................................................................... 174
Enable/Disable GM ............................................................................................................................................... 174
Set Length Range for GM ..................................................................................................................................... 175
Code One ..................................................................................................................................................................... 176
Restore Factory Defaults ...................................................................................................................................... 176
Enable/Disable Code One..................................................................................................................................... 176
Set Length Range for Code One........................................................................................................................... 177
USPS Postnet .............................................................................................................................................................. 178
Restore Factory Defaults ...................................................................................................................................... 178
Enable/Disable USPS Postnet .............................................................................................................................. 178
Transmit Check Character .................................................................................................................................... 178
USPS Intelligent Mail ................................................................................................................................................... 179
Restore Factory Defaults ...................................................................................................................................... 179
Enable/Disable USPS Intelligent Mail ................................................................................................................... 179
Royal Mail .................................................................................................................................................................... 180
Restore Factory Defaults ...................................................................................................................................... 180
Enable/Disable Royal Mail .................................................................................................................................... 180
USPS Planet ................................................................................................................................................................ 181
Restore Factory Defaults ...................................................................................................................................... 181
Enable/Disable USPS Planet ................................................................................................................................ 181
Transmit Check Character .................................................................................................................................... 181
KIX Post ....................................................................................................................................................................... 182
Restore Factory Defaults ...................................................................................................................................... 182
Enable/Disable KIX Post ....................................................................................................................................... 182
Australian Postal .......................................................................................................................................................... 183
Restore Factory Defaults ...................................................................................................................................... 183
Enable/Disable Australian Postal .......................................................................................................................... 183
Specific OCR-B ............................................................................................................................................................ 184
Restore Factory Defaults ...................................................................................................................................... 184
Enable/Disable Specific OCR-B ............................................................................................................................ 184
Passport OCR .............................................................................................................................................................. 185
Restore Factory Defaults ...................................................................................................................................... 185
Enable/Disable Passport OCR .............................................................................................................................. 185

Chapter 6 Data Formatter ........................................................................................................................................................ 186

Introduction .................................................................................................................................................................. 186


Add a Data Format ....................................................................................................................................................... 186
Enable/Disable Data Formatter .................................................................................................................................... 189
Non-Match Error Beep ................................................................................................................................................. 190
Multiple Data Formats .................................................................................................................................................. 191
Data Format Selection ................................................................................................................................................. 192
Change Data Format for a Single Scan ....................................................................................................................... 193
Clear Data Format........................................................................................................................................................ 194
Query Data Formats ..................................................................................................................................................... 194
Formatter Command Type 6 ........................................................................................................................................ 195
Send Commands .................................................................................................................................................. 195
Move Commands .................................................................................................................................................. 198
Search Commands ............................................................................................................................................... 200
Miscellaneous Commands .................................................................................................................................... 203

Chapter 7 Prefix & Suffix ......................................................................................................................................................... 209

Introduction .................................................................................................................................................................. 209


Global Settings ............................................................................................................................................................. 210
Enable/Disable All Prefixes/Suffixes...................................................................................................................... 210
Prefix Sequence ........................................................................................................................................................... 210
Custom Prefix............................................................................................................................................................... 211
Enable/Disable Custom Prefix .............................................................................................................................. 211
Set Custom Prefix ................................................................................................................................................. 211
AIM ID Prefix ................................................................................................................................................................ 212
Code ID Prefix .............................................................................................................................................................. 213
Restore All Default Code IDs ................................................................................................................................ 213
Modify Code ID ..................................................................................................................................................... 213
Custom Suffix ............................................................................................................................................................... 222
Enable/Disable Custom Suffix ............................................................................................................................... 222
Set Custom Suffix ................................................................................................................................................. 222
Data Packing ................................................................................................................................................................ 223
Introduction ........................................................................................................................................................... 223
Data Packing Options ........................................................................................................................................... 223
Terminating Character Suffix ........................................................................................................................................ 225
Enable/Disable Terminating Character Suffix ........................................................................................................ 225
Set Terminating Character Suffix........................................................................................................................... 225

Chapter 8 Batch Programming ................................................................................................................................................ 227

Introduction .................................................................................................................................................................. 227


Create a Batch Command ............................................................................................................................................ 228
Create a Batch Barcode ............................................................................................................................................... 228
Use Batch Barcode ...................................................................................................................................................... 229

Appendix ................................................................................................................................................................................... 230

Digit Barcodes .............................................................................................................................................................. 230


Save/Cancel Barcodes ................................................................................................................................................. 233
Factory Defaults Table ................................................................................................................................................. 234
AIM ID Table................................................................................................................................................................. 242
Code ID Table .............................................................................................................................................................. 244
Symbology ID Number ................................................................................................................................................. 246
ASCII Table .................................................................................................................................................................. 248
Unicode Key Maps ....................................................................................................................................................... 252
Preface

Introduction
This manual provides detailed instructions for setting up and using the Rakinda
- LV3000H fixed mount barcode scanner
(hereinafter referred to as “the LV3000H” or “the scanner”).

Chapter Description

 Chapter 1, Getting Started : Gives a general description of the LV3000H


.

 Chapter 2, EasySet : Introduces a useful tool you can use to set up the LV3000H
.

 Chapter 3, System Settings : Introduces three configuration methods and describes how to configure
general parameters of the LV3000H
.

 Chapter 4, RS-232 Interface : Describes how to configure RS-232 communication parameters.

 Chapter 5, USB Interface : Describes how to configure USB communication parameters.

 Chapter 6, Symbologies : Lists all compatible symbologies and describes how to configure the
relevant parameters.

 Chapter 7, Data Formatter : Explains how to customize scanned data with the advanced data formatter.

 Chapter 8, Prefix & Suffix : Describes how to use prefix and suffix to customize scanned data.

 Chapter 9, Batch Programming : Explains how to integrate a complex programming task into a single barcode.

 Appendix : Provides factory defaults table and a bunch of frequently used programming
barcodes.

1
Explanation of Icons

This icon indicates something relevant to this manual.

This icon indicates this information requires extra attention from the reader.

This icon indicates handy tips that can help you use or configure the scanner with ease.

This icon indicates practical examples that can help you to acquaint yourself with operations.

2
Chapter 1 Getting Started

Introduction

The LV 3000H fixed mount scanner, armed with the world-leading Rakinda patented , a computerized image
recognition system-on-chip, bring about a new era of 2D barcode scanner.

LV3000H support s all mainstream 1D and standard 2D barcode symbologies (e.g., PDF417, QR Code, Data Matrix, Aztec
and Chinese Sensible Code). It can read barcodes on virtually any medium - paper, plastic card, mobile phones and LCD
displays.

Designed for fixed mount integrations, this scanner is easy to fit into various equipment such as self-service cabinets,
vending machines, ticket validators, ATMs, access control, retail POS and kiosks.

Features of the LV3000H

 Unmatched reading performance: Armed with Rakinda ’s fifth-generation of technology, the LV 3000H is capable
of reading 1D as well as high-volume 2D barcodes on the screen covered with protective film.
 IR/Light triggers: The combination of IR sensor and light sensor exhibits an improved sensitivity in activating the
scanner to scan barcodes as they are presented, to achieve higher throughput and productivity.
 Highly visible laser aimer: The scanner provides a laser-generated crosshair aiming pattern that is clear and bright
even in bright sunlight, ensuring first time accurate aim.
 Easy to configure and update.

Unpacking

Open the package and take out the scanner and its accessories. Check to make sure everything on the packing list is
present and intact. If any contents are damaged or missing, please keep the original package and contact your dealer
immediately for after-sales service.

3
LV3000H Scanner

4
Data Port Pinout

PIN Signal Type Function


1 NC - NC
2 nTrig I Trigger input: normal 3.3V, pull low to 0V @ trigger
3 VCC P Power+ (DC5V)
4 TXD O RS-232 output
5 RXD I RS-232 input
6 CTS I/O Clear to send (RS-232)
7 RTS I/O Request to send (RS-232)
8 GND P Ground
9 D- I/O
USB signal
10 D+ I/O

5
Dimensions (unit: mm)

6
IR Triggering Range

7
Optics

Horizontal FOV:

Vertical FOV:

8
Connecting the LV3000H to a Host Device

The scanner must be connected to a host device in actual application, such as PC, POS or any intelligent
terminal with USB or RS-232 port, using a USB or RS-232 cable.

USB

USB port on the host device

RS-232

RS-232 port on the host device

Note: Please check the port on the host device and purchase the cable accordingly.

9
Using USB Cable

Connect the scanner to a host device with a USB cable with RJ45 and USB connectors:

1. Plug the cable’s RJ45 connector into the data port on the scanner.

2. Plug the cable’s USB connector into the USB port on the host device.

10
Using RS-232 Cable

Connect the scanner to a host device with an RS-232 cable with RJ45, RS-232 connector and a power
jack:

1. Plug the cable’s RJ45 connector into the data port on the scanner.

2. Plug the cable’s RS-232 connector into the RS-232 port on the host device.

3. Plug the power adapter into the power jack of the cable.

4. Connect the power adapter to a power outlet.

11
Scanning Instructions

1. Position the barcode on mobile phone screen or paper in the center of the scan window.

2. For a successful read, the scanner will send the data to the host with its green Good Read LED flashing once.

Maintenance

 The scan window should be kept clean.

 Do not scratch the scan window.

 Use soft brush to remove the stain from the scan window.

 Use the soft cloth to clean the window, such as eyeglass cleaning cloth.

 Do not spray any liquid on the scan window.

 Do not use any detergent to clean other parts of the device except for water.

Note: The warranty DOES NOT cover damages caused by inappropriate care and maintenance.

12
Enter Setup

Chapter 2 System Settings

Introduction
There are three ways to configure the LV3000H : Barcode programming, and command programming.

Barcode Programming

LV3000H can be configured by scanning programming barcodes. All user programmable features/options are described
along with their programming barcodes/commands in the following sections.

This programming method is most straightforward. However, it requires manually scanning barcodes. As a result, errors are
more likely to occur.

Command Programming

LV3000H can also be configured by serial commands sent from the host device.

Users can design an application program to send those command strings to the scanners to perform device configuration.

For more information, refer to the Serial Programming Command Manual.

** Exit Setup 14
Enter Setup

Programming Barcode/ Programming Command/Function

The figure above is an example that shows you the programming barcode and command for the Enter Setup function:

1. The No Case Conversion barcode.

2. The No Case Conversion command.

3. The description of feature/option.

4. ** indicates factory default settings.

15 ** Exit Setup
Enter Setup

Use of Programming Barcodes


Scanning the Enter Setup barcode can enable the scanner to enter the setup mode. Then you can scan a number of
programming barcodes to configure your scanner. To exit the setup mode, scan the Exit Setup barcode or a non-
programing barcode, or reboot the scanner.

** Exit Setup

Enter Setup

Programming barcode data (i.e. the characters under programming barcode) can be transmitted to the host device. Scan
the appropriate barcode below to enable or disable the transmission of programming barcode data to the host device.

** Do Not Transmit Programming Barcode Data

Transmit Programming Barcode Data

** Exit Setup 16
Enter Setup

Illumination
A couple of illumination options are provided to improve the lighting conditions during every image capture:

Normal: Illumination LEDs are turned on during image capture.

Always On: Illumination LEDs keep on after the scanner is powered on.

Off: Illumination LEDs are off all the time.

Fade Up: Illumination LEDs are dimly lit when in standby mode and gradually increase their brightness during image capture.

** Normal

Off

Always On

Fade Up

17 ** Exit Setup
Enter Setup

Aiming
When scanning/capturing image, the scanner projects an aiming pattern which allows positioning the target barcode within
its field of view and thus makes decoding easier.

Normal: The scanner projects an aiming pattern only during barcode scanning/capture.

Always On: Aiming pattern is constantly on after the scanner is powered on.

Off: Aiming pattern is off all the time.

** Normal

Off

Always On

Good Read LED


The green LED can be programmed to be On or Off to indicate good read.

** On

Off

** Exit Setup 18
Enter Setup

Good Read LED Duration

This parameter sets the amount of time that the Good Read LED to remain on following a good read. It is programmable in
1ms increments from 1ms to 2,500ms.

** Short (20ms)

Medium (120ms)

Long (220ms)

Prolonged (320ms)

Custom (1 - 2,500ms)

Set the Good Read LED duration to 800ms:

1. Scan the Enter Setup barcode.

2. Scan the Custom barcode.

3. Scan the numeric barcodes “8”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

19 ** Exit Setup
Enter Setup

Power On Beep
The scanner can be programmed to beep when it is powered on. Scan the Off barcode if you do not want a power on beep.

** On

Off

Good Read Beep


Scanning the Off barcode can turn off the beep that indicate successful decode; scanning the On barcode can turn it back
on.

** On

Off

** Exit Setup 20
Enter Setup

Good Read Beep Duration

This parameter sets the length of the beep the scanner emits on a good read. It is programmable in 1ms increments from
20ms to 300ms.

Short (40ms)

** Medium (80ms)

Long (120ms)

Custom (20 – 300ms)

Set the Good Read Beep duration to 200ms:

1. Scan the Enter Setup barcode.

2. Scan the Custom barcode.

3. Scan the numeric barcodes “2”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

21 ** Exit Setup
Enter Setup

Good Read Beep Frequency

This parameter is programmable in 1Hz increments from 20Hz to 20,000Hz.

Extra Low (800Hz)

Low (1600Hz)

** Medium (2730Hz)

High (4200Hz)

Custom (20 - 20,000Hz)

Set the Good Read Beep frequency to 2,000Hz:

1. Scan the Enter Setup barcode.

2. Scan the Custom barcode.

3. Scan the numeric barcodes “2”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

** Exit Setup 22
Enter Setup

Good Read Beep Volume

** Loud

Medium

Low

23 ** Exit Setup
Enter Setup

Scan Mode
 Level Mode: A trigger pull activates a decode session. The decode session continues until a barcode is decoded or
you release the trigger.

 Sense Mode: The scanner waits for the image stabilization timeout to expire before activating a decode session every
time it detects a change in ambient illumination. Decode session continues until a barcode is decoded or the decode
session timeout expires. In this mode, a trigger pull can also activate a decode session. The decode session continues
until a barcode is decoded or the trigger is released. When the session ends, the scanner continues to monitor ambient
illumination.Timeout between Decodes (Same Barcode) can avoid undesired rereading of same barcode in a given
period of time. Sensitivity can change the Sense Mode’s sensibility to changes in ambient illumination.

 Continuous Mode: The scanner automatically starts one decode session after another. To suspend/resume barcode
reading, simply press the trigger. Timeout between Decodes (Same Barcode) can avoid undesired rereading of
same barcode in a given period of time.

 Pulse Mode: When the trigger is pulled and released, scanning is activated until a barcode is decoded or the decode
session timeout expires (The decode session timeout begins when the trigger is released).

Level Mode

** Sense Mode

Continuous Mode

Pulse Mode

** Exit Setup 24
Enter Setup

Decode Session Timeout


This parameter sets the maximum time decode session continues during a scan attempt. It is programmable in 1ms
increments from 1ms to 3,600,000ms. When it is set to 0, the timeout is infinite. The default setting is 3,000ms.

Decode Session Timeout

Set the decode session timeout to 1,500ms:

1. Scan the Enter Setup barcode.

2. Scan the Decode Session Timeout barcode.

3. Scan the numeric barcodes “1”, “5”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

25 ** Exit Setup
Enter Setup

Image Stabilization Timeout (Sense Mode)


This parameter defines the amount of time that the scanner waits for the image to stabilize to a point that it can be decoded
with more accuracy. It is programmable in 1ms increments from 0ms to 3,000ms. The default setting is 200ms.

Image Stabilization Timeout

Set the image stabilization timeout to 800ms:

1. Scan the Enter Setup barcode.

2. Scan the Image Stabilization Timeout barcode.

3. Scan the numeric barcodes “8”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

** Exit Setup 26
Enter Setup

Timeout between Decodes (Same Barcode)


Timeout between Decodes (Same Barcode) can avoid undesired rereading of same barcode in a given period of time. This
feature is only applicable to the Sense and Continuous modes.

To enable/disable the Timeout between Decodes (Same Barcode), scan the appropriate barcode below.

Enable Timeout between Decodes (Same Barcode): Do not allow the scanner to re-read same barcode before the
timeout between decodes (same barcode) expires.

Disable Timeout between Decodes (Same Barcode): Allow the scanner to re-read same barcode.

Enable Timeout between Decodes (Same Barcode)

** Disable Timeout between Decodes (Same Barcode)

The following parameter sets the timeout between decodes for same barcode. It is programmable in 1ms increments from
0ms to 3,600,000ms. When it is set to a value greater than 3,000, the timeout for rereading same programming barcode is
limited to 3,000ms. The default setting is 1,500ms.

Decode Session Timeout (Same Barcode)

Set the decode session timeout to 1,000ms:

1. Scan the Enter Setup barcode.

2. Scan the Decode Session Timeout (Same Barcode) barcode.

3. Scan the numeric barcodes “1”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

27 ** Exit Setup
Enter Setup

Sensitivity (Sense Mode)


Sensitivity specifies the degree of acuteness of the scanner’s response to changes in ambient illumination. The higher the
sensitivity, the lower requirement in illumination change to trigger the scanner. You can select an appropriate degree of
sensitivity that fits the ambient environment. The feature is only applicable to the Sense mode.

Low Sensitivity

** Medium Sensitivity

High Sensitivity

Enhanced Sensitivity

Custom Sensitivity (Level 1-20)

Set the sensitivity to Level 10:


1. Scan the Enter Setup barcode.

2. Scan the Custom Sensitivity barcode.

3. Scan the numeric barcodes “1” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the Exit Setup barcode.

** Exit Setup 28
Enter Setup

Trigger Commands
When Enable Trigger Commands is selected, you can activate and deactivate the scanner in the Level mode with serial
trigger commands. Sending the Start Scanning command (default: <SOH> T <EOT>, user-programmable) to the scanner
in the Level mode activates a decode session. The decode session continues until a barcode is decoded or the decode
session timeout expires or the scanner receives the Stop Scanning command (default: <SOH> P <EOT>, user-
programmable).

** Disable Trigger Commands

Enable Trigger Commands

Modify Start Scanning Command

The Start Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the
character “?” (HEX: 0x3F) cannot be the first character. The default Start Scanning command is <SOH> T <EOT>.

Modify Start Scanning Command

Set the Start Scanning command to “*T”:

1. Scan the Enter Setup barcode.

2. Scan the Modify Start Scanning Command barcode.

3. Scan the numeric barcodes “2”, “A”, “5” and “4” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

29 ** Exit Setup
Enter Setup

Modify Stop Scanning Command

The Stop Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the
character “?” (HEX: 0x3F) cannot be the first character. The default Stop Scanning command is <SOH> P <EOT>.

Modify Stop Scanning Command

Set the Stop Scanning command to “*P”:

1. Scan the Enter Setup barcode.

2. Scan the Modify Stop Scanning Command barcode.

3. Scan the numeric barcodes “2”, “A”, “5” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

** Exit Setup 30
Enter Setup

Scanning Preference
Normal Mode: Select this mode when reading barcodes on paper.

Screen Mode: Select this mode when reading barcodes on the screen.

** Normal Mode

Screen Mode

Decode Area
 Whole Area Decoding: The scanner attempts to decode barcode(s) within its field of view, from the center to the
periphery, and transmits the barcode that has been first decoded.

 Specific Area Decoding: The scanner attempts to read barcode(s) within a specified decoding area and transmits
the barcode that has been first decoded. This option allows the scanner to narrow its field of view to make sure it
reads only those barcodes intended by the user. For instance, if multiple barcodes are placed closely together, specific
area decoding in conjunction with appropriate pre-defined decoding area will insure that only the desired barcode is
read.

** Whole Area Decoding

Specific Area Decoding

31 ** Exit Setup
Enter Setup

If Specific Area Decoding is enabled, the scanner only reads barcodes that intersect the predefined decoding area.

The default decoding area is an area of 40% top, 60% bottom, 40% left and 60% right of the scanner’s field of view

You can define the decoding area using the Top of Decoding Area, Bottom of Decoding Area, Left of Decoding Area
and Right of Decoding Area barcodes as well as numeric barcode(s) that represent(s) a desired percentage (0-100). The
value of Bottom must be greater than that of Top; the value of Right must be greater than that of Left.

Top of Decoding Area

Bottom of Decoding Area

Left of Decoding Area

Right of Decoding Area

** Exit Setup 32
Enter Setup

Barcode 1

Barcode 2

Program the scanner to only read Barcode 1 in the figure above by setting the decoding area
to 10% top, 45% bottom, 15% left and 30% right:
1. Scan the Enter Setup barcode.
2. Scan the Top of Decoding Area barcode.
3. Scan the numeric barcode “0” from the “Digit Barcodes” section in Appendix.
4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the Bottom of Decoding Area barcode.
6. Scan the numeric barcodes “4” and “5” from the “Digit Barcodes” section in Appendix.
7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
8. Scan the Top of Decoding Area barcode.
9. Scan the numeric barcodes “1” and “0” from the “Digit Barcodes” section in Appendix.
10. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
11. Scan the Left of Decoding Area barcode.
12. Scan the numeric barcode “0” from the “Digit Barcodes” section in Appendix.
13. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
14. Scan the Right of Decoding Area barcode.
15. Scan the numeric barcodes “3” and “0” from the “Digit Barcodes” section in Appendix.
16. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
17. Scan the Left of Decoding Area barcode.
18. Scan the numeric barcodes “1” and “5” from the “Digit Barcodes” section in Appendix.
19. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
20. Scan the Exit Setup barcode.

33 ** Exit Setup
Enter Setup

Image Flipping

** Do Not Flip

Flip Horizontally

Flip Vertically

Flip Horizontally & Vertically

Example of image not flipped Example of image flipped horizontally

Example of image flipped vertically Example of image flipped horizontally & vertically

** Exit Setup 34
Enter Setup

Bad Read Message


Scan the appropriate barcode below to select whether or not to send a bad read message (user-programmable) when a
good read does not occur before trigger release, or the decode session timeout expires, or the scanner receives the Stop
Scanning command (For more information, see the “Serial Trigger Command” section in this Chapter).

** Bad Read Message OFF

Bad Read Message ON

Set Bad Read Message

A bad read message can contain up to 7 characters (HEX values from 0x00 to 0xFF). To set a bad read message, scan the
Set Bad Read Message barcode, the numeric barcodes representing the hexadecimal values of desired character(s) and
the Save barcode. The default setting is “NG”.

Set Bad Read Message

Set the bad read message to “F” (HEX: 0x46):

1. Scan the Enter Setup barcode.

2. Scan the Set Bad Read Message barcode.

3. Scan the numeric barcodes “4” and “6” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

35 ** Exit Setup
Enter Setup

Default Settings
Factory Defaults

Scanning the following barcode can restore the scanner to the factory defaults.

You may need to reset all parameters to the factory defaults when:

 scanner is not properly configured so that it fails to decode barcodes.

 you forget previous configuration and want to avoid its impact.

Restore All Factory Defaults

Custom Defaults

Scanning the Restore All Custom Defaults barcode can reset all parameters to the custom defaults. Scanning the Save
as Custom Defaults barcode can set the current settings as custom defaults.

Custom defaults are stored in the non-volatile memory.

Save as Custom Defaults

Restore All Custom Defaults

Restoring the scanner to the factory defaults will not remove the custom defaults from the scanner.

** Exit Setup 36
Enter Setup

Chapter 3 RS-232 Interface

Introduction
When the scanner is connected to the RS-232 port of a host device, the scanner will automatically enable RS-232
communication. However, you need to set communication parameters (including baud rate, parity check, data bit and stop
bit) on the scanner to match the host device so that two devices can communicate with each other.

** Exit Setup 38
Enter Setup

Baud Rate

Baud rate is the number of bits of data transmitted per second. Set the baud rate to match the host requirements.

115200

57600

38400

19200

14400

** 9600

4800

2400

39 ** Exit Setup
Enter Setup

Parity Check

Set the parity type to match the host requirements.

 Odd Parity: If the data contains an odd number of 1 bits, the parity bit value is set to 0.

 Even Parity: If the data contains an even number of 1 bits, the parity bit value is set to 0.

 None: Select this option when no parity bit is required.

** None

Even Parity

Odd Parity

** Exit Setup 40
Enter Setup

Data Bit

Set the number of data bits to match the host requirements.

7 Data Bits

** 8 Data Bits

Stop Bit

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the
receiving device for the next character in the serial data stream. Set the number of stop bits to match the host requirements.

** 1 Stop Bit

2 Stop Bits

41 ** Exit Setup
Enter Setup

Hardware Auto Flow Control

If this feature is enabled, the scanner determines whether to transmit data based on CTS signal level. When CTS signal is
at a low level which means the serial port’s cache memory of receiving device (such as PC) is full, the scanner sends data
through RS-232 port until CTS signal is set to high level by receiving device. When the scanner is not ready for receiving, it
will set RTS signal to low level. When sending device (such as PC) detects it, it will not send data to the scanner any more
to prevent data loss.

If this feature is disabled, reception/transmission of serial data will not be influenced by RTS/CTS signal.

** Disable Hardware Auto Flow Control

Enable Hardware Auto Flow Control

Before enabling this feature, make sure that RTS/CTS signal lines are contained in RS-232 cable.
Without the signal lines, RS-232 communication errors will occur.

** Exit Setup 42
Enter Setup

Chapter 4 USB Interface

Introduction
There are four options for USB connection:

 USB HID Keyboard: The scanner’s transmission is simulated as USB keyboard input with no need for command
configuration or a driver. Barcode data could be entered by the virtual keyboard directly and it is also convenient for
the host device to receive data.

 USB CDC: It is compliant with the standard USB CDC class specifications defined by the USB-IF and allows the host
device to receive data in the way as a serial port does. A driver is needed when using this feature.

 HID POS (POS HID Barcode Scanner): It is based on the HID interface, with no need for a custom driver. It excels
virtual keyboard and traditional RS-232 interface in transmission speed.

 IBM SurePOS: It conforms to IBM (now Toshiba Global Commerce Solutions) 4698 USB scanner interface
specifications.

When the scanner is connected to both USB and RS-232 ports on a host device, it will select the USB connection by default.

43 ** Exit Setup
Enter Setup

USB HID Keyboard


When the scanner is connected to the USB port on a host device, you can enable the USB HID Keyboard feature by
scanning the barcode below. Then scanner’s transmission will be simulated as USB keyboard input. The Host receives
keystrokes onthe virtual keyboard. It works on a Plug and Play basis and no driver is required.

USB HID Keyboard

If the host device allows keyboard input, then no extra software is needed for HID Keyboard input.

** Exit Setup 44
Enter Setup

USB Country Keyboard Types

Keyboard layouts vary from country to country. The default setting is U.S. keyboard.

** U.S. (English)

Belgium

Brazil

Canada (French)

Czechoslovakia

Denmark

Finland (Swedish)

45 ** Exit Setup
Enter Setup

France

Germany/ Austria

Greece

Hungary

Israel (Hebrew)

Italy

Latin America/ South America

Netherlands (Dutch)

** Exit Setup 46
Enter Setup

Norway

Poland

Portugal

Romania

Russia

Slovakia

Spain

Sweden

47 ** Exit Setup
Enter Setup

Switzerland (German)

Turkey_F

Turkey_Q

UK

Japan

** Exit Setup 48
Enter Setup

Beep on Unknown Character

Due to the differences in keyboard layouts, some characters contained in barcode data may be unavailable on the selected
keyboard. As a result, the scanner fails to transmit the unknown characters.

Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected.

** Do Not Beep on Unknown Character

Beep on Unknown Character

Supposing French keyboard (Country Code: 7) is selected and barcode data ”AÐF” is beingdealted with,
the keyboard will fail to locate the “Д (0xD0) character and the scanner will ignore the character and
continue to process the next one.

Do Not Beep on Unknown Character: The scanner does not beep and the Host receives “AF”.

Beep on Unknown Character: The scanner beeps and the Host still receives “AF”.

If Emulate ALT+Keypad ON is selected, Beep on Unknown Character does not function.

49 ** Exit Setup
Enter Setup

Emulate ALT+Keypad

When Emulate ALT+Keypad is turned on, any character is sent over the numeric keypad no matter which keyboard type
is selected.

1. ALT Make

2. Enter the number corresponding to a desired character on the keypad.

3. ALT Break

After Emulate ALT+Keypad ON is selected, you need to choose the code page with which the barcodes were created and
to turn Unicode Encoding On or Off depending on the encoding used by the application software.

** Emulate ALT+Keypad OFF

Emulate ALT+Keypad ON

Any character can be sent in the ALT+Keypad way. However, since sending a character involves multiple
keystroke emulations, this method appears less efficient.

Supposing Emulate ALT+Keypad is ON, Unicode Encoding is Off, and Code Page 1252 (Latin,
Western European) is selected, barcode data ”AÐF” (65/208/70) is sent as below:

“A” – “ALT Make” + “065” + “ALT Break”

“Д -- “ALT Make” + “208” + “ALT Break”

“F” -- “ALT Make” + “070” + “ALT Break”

** Exit Setup 50
Enter Setup

Code Page

Code pages define the mapping of character codes to characters. If the data received does not display with the proper
characteris, it may be because the barcode being scanned was created using a code page that is different from the one the
host program is expecting. If this is the case, select the code page with which the barcodes were created by scanning the
appropriate barcode below. For PDF417, QR Code, Aztec and Data Matrix, besides setting the code page, you also need
to set the character encoding in the “Character Encoding” section in Chapter 6. This feature is only effective when Emulate
ALT+Keypad is turned on.

** Code Page 1252 (Latin, Western European)

Code Page 1251 (Cyrillic)

Code Page 1250 (Central European)

Code Page 936 (Simplified Chinese, GB2312,GBK)

Code Page 950 (Traditional Chinese, Big5)

51 ** Exit Setup
Enter Setup

Unicode Encoding

Different host program may use different character encodings for handling incoming barcode data. For instance, Microsoft
Office Word uses Unicode encoding and therefore you should turn Unicode Encoding on, whereas Microsoft Office Excel
or Notepad uses Code Page encoding and therefore you should turn Unicode Encoding off. This feature is only effective
when Emulate ALT+Keypad is turned on.

** Off

On

** Exit Setup 52
Enter Setup

Function Key Mapping

When Function Key Mapping is enabled, function character (0x00 - 0x1F) are sent as ASCII sequences over the numeric
keypad.

1. CTRL Make

2. Press function key

3. CTRL Break

** Disable Function Key Mapping

Enable Function Key Mapping

Supposing the Function Key Mapping feature is enabled and other parameters of USB HID Keyboard
adopt factory defaults, barcode data “A<HT>(i.e. Horizontal Tab)F” (0x41/0x09/0x46) is sent as below:

1. “A” - Keystroke “A”.

2. “Ctrl I” - “Ctrl Make” + Keystroke “I” + “Ctrl Break”

3. “F” - Keystroke “F”

For some text editors, “Ctrl I” means italic convert. So the output may be “AF”.

Emulate ALT+Keypad ON prevails over Enable Function Key Mapping.

53 ** Exit Setup
Enter Setup

ASCII Function Key Mapping Table

ASCII Function ASCII Value (HEX) No Function Key Mapping Function Key Mapping
NUL 00 Null Ctrl+2
SOH 01 Keypad Enter Ctrl+A
STX 02 Caps Lock Ctrl+B
ETX 03 Null Ctrl+C
EOT 04 Null Ctrl+D
ENQ 05 Null Ctrl+E
ACK 06 Null Ctrl+F
BEL 07 Enter Ctrl+G
BS 08 Left Arrow Ctrl+H
HT 09 Horizontal Tab Ctrl+I
LF 0A Down Arrow Ctrl+J
VT 0B Vertical Tab Ctrl+K
FF 0C Delete Ctrl+L
CR 0D Enter Ctrl+M
SO 0E Insert Ctrl+N
SI 0F Esc Ctrl+O
DLE 10 F11 Ctrl+P
DC1 11 Home Ctrl+Q
DC2 12 PrintScreen Ctrl+R
DC3 13 Backspace Ctrl+S
DC4 14 tab+shift Ctrl+T
NAK 15 F12 Ctrl+U
SYN 16 F1 Ctrl+V
ETB 17 F2 Ctrl+W
CAN 18 F3 Ctrl+X
EM 19 F4 Ctrl+Y
SUB 1A F5 Ctrl+Z
ESC 11 F6 Ctrl+[
FS 1C F7 Ctrl+\
GS 1D F8 Ctrl+]
RS 1E F9 Ctrl+6
US 1F F10 Ctrl+-

** Exit Setup 54
Enter Setup

ASCII Function Key Mapping Table (Continued)

The last five characters (0x1B~0x1F) in the table above apply to US keyboard layout only. The following chart provides the
equivalents of these five characters for other countries.

Country Code

United States [ \ ] 6 -

Belgium [ < ] 6 -

Scandinavia 8 < 9 6 -

France ^ 8 $ 6 =

Germany à + 6 -

Italy \ + 6 -

Switzerland < .. 6 -

United Kingdom [ ¢ ] 6 -

Denmark 8 \ 9 6 -

Norway 8 \ 9 6 -

Spain [ \ ] 6 -

55 ** Exit Setup
Enter Setup

Inter-Keystroke Delay

This parameter specifies the delay between emulated keystrokes.

** No Delay

Long Delay (40ms)

Short Delay (20ms)

Caps Lock

The Caps Lock ON option can invert upper and lower case characters contained in barcode data. This inversion occurs
regardless of the state of Caps Lock key on the host device’s keyboard.

** Caps Lock OFF

Caps Lock ON

Emulate ALT+Keypad ON/ Convert All to Upper Case/ Convert All to Lower Case prevails over Caps
Lock ON.

When the Caps Lock ON feature is selected, barcode data “AbC” is transmitted as “aBc”.

** Exit Setup 56
Enter Setup

Convert Case

Scan the appropriate barcode below to convert all bar code data to your desired case.

** No Case Conversion

Convert All to Upper Case

Convert All to Lower Case

When the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”.

If Emulate ALT+Keypad ON is selected, Convert All to Lower Case and Convert All to Upper Case do
not function.

57 ** Exit Setup
Enter Setup

Emulate Numeric Keypad

 Do Not Emulate Numeric Keypad 1: Sending a number (0-9) is emulated as keystroke(s) on main keyboard.

 Emulate Numeric Keypad 1: Sending a number (0-9) is emulated as keystroke(s) on numeric keypad. The state of
Num Lock on the simulated numeric keypad is determined by its equivalent on the host device. If Num Lock on the
host device is turned off, the output of simulated numeric keypad is function key instead of number.

 Do Not Emulate Numeric Keypad 2: Sending “+”, “-”, “*” and “/” is emulated as keystroke(s) on main keyboard.

 Emulate Numeric Keypad 2: Sending “+”, “-”, “*” and “/” is emulated as keystroke(s) on numeric keypad.

** Do Not Emulate Numeric Keypad 1

Emulate Numeric Keypad 1

** Exit Setup 58
Enter Setup

** Do Not Emulate Numeric Keypad 2

Emulate Numeric Keypad 2

Emulate ALT+Keypad ON prevails over Emulate Numeric Keypad.

Supposing the Emulate Numeric Keypad feature is enabled:

if Num Lock on the host device is ON, “A4.5” is transmitted as “A4.5”;

if Num Lock on the host device is OFF, “A4.5” is transmitted as follows:

1. “A” is sent as is because it is not included in numeric keypad;

2. “4” is sent as the function key “Cursor Move to Left”;

3. “.” is sent as the function key “Delete After the Cursor”;

4. “5” is not sent as it does not correspond to any function key.

59 ** Exit Setup
Enter Setup

Fast Mode

When Fast Mode On is selected, the scanner sends characters to the Host faster. If the Host drops characters, turn the
Fast Mode off or change the polling rate to a bigger value.

** Fast Mode Off

Fast Mode On

** Exit Setup 60
Enter Setup

Polling Rate

This parameter specifies the polling rate for a USB keyboard. If the Host drops characters, change the polling rate to a
bigger value.

1ms

2ms

3ms

** 4ms

5ms

6ms

7ms

61 ** Exit Setup
Enter Setup

8ms

9ms

10ms

** Exit Setup 62
Enter Setup

USB CDC
If your scanner is connected to the USB port on a host device, the USB CDC feature allows the host device to receive data
in the way as a serial port does. A driver is needed when using this feature. You may contact us and we will send it to you.

** USB CDC

63 ** Exit Setup
Enter Setup

HID POS (POS HID Barcode Scanner)


Introduction

The HID-POS interface is recommended for new application programs. It can send up to 56 characters in a single USB
report and appears more efficient than keyboard emulation.

Features:

 HID based, no custom driver required.

 Way more efficient in communication than keyboard emulation and traditional RS-232 interface.

USB HID-POS

Access the Scanner with Your Program

Use CreateFile to access the scanner as a HID device and then use ReadFile to deliver the scanned data to the application
program. Use WriteFile to send data to the scanner.

For detailed information about USB and HID interfaces, go to www.USB.org.

** Exit Setup 64
Enter Setup

Acquire Scanned Data

After a barcode is decoded, the scanner sends an input report as below:

Bit

Byte 7 6 5 4 3 2 1 0

0 Report ID = 0x02

1 Barcode Length

2-57 Decoded Data (1-56)

58-61 Reserved

62 Symbology Identifier or N/C: 0x00


Decoded data
63 - - - - - - - continued

Send Command to the Scanner

This output report is used to send commands to the scanner. All programming commands can be used.

Bit

Byte 7 6 5 4 3 2 1 0

0 Report ID = 0x04

1 Length of command

2-63 Command (1-62)

65 ** Exit Setup
Enter Setup

IBM SurePOS (Tabletop)

IBM SurePOS (Tabletop)

IBM SurePOS (Handheld)

IBM SurePOS (Handheld)

VID/PID
USB uses VID (Vendor ID) and PID (Product ID) to identify and locate a device. The VID is assigned by USB Implementers
Forum. Rakinda’s vendor ID is 1EAB (Hex). A range of PIDs are used for each Rakinda product family. Every PID contains
a base number and interface type (keyboard, COM port, etc.).
Product Interface PID (Hex) PID (Dec)
USB HID Keyboard 1D03 7427
USB CDC 1D06 7430
LV3000H HID POS 1D10 7440
IBM SurePOS (Tabletop) 1D20 7456
IBM SurePOS(Handheld) 1D21 7457

** Exit Setup 66
Enter Setup

Chapter 5 Symbologies

Introduction
Every symbology (barcode type) has its own unique attributes. This chapter provides programming barcodes for configuring
the scanner so that it can identify various symbologies. It is recommended to disable those that are rarely used to increase
the efficiency of the scanner.

Global Settings
Enable/Disable All Symbologies

If the Disable All Symbologies feature is enabled, the scanner will not be able to read any non-programming barcodes
except the programming barcodes.

Enable All Symbologies

Disable All Symbologies

Enable/Disable 1D Symbologies

Enable 1D Symbologies

Disable 1D Symbologies

67 ** Exit Setup
Enter Setup

Enable/Disable 2D Symbologies

Enable 2D Symbologies

Disable 2D Symbologies

Enable Postal Symbologies

Enable All Postal Symbologies

Disable All Postal Symbologies

** Exit Setup 68
Enter Setup

1D Twin Code

1D twin code is two 1D barcodes of a symbology or of different symbologies paralleled vertically. Both barcodes must have
similar specifications and be placed closely together.

There are 3 options for reading 1D twin code:

 Single 1D Code Only: Read either 1D code.

 Twin 1D Code Only: Read both 1D codes. Transmission sequence: upper 1D code followed by lower 1D code.

 Both Single & Twin: Read both 1D codes. If successful, transmit as twin 1D code only. Otherwise, try single 1D code
only.

** Single 1D Code Only

Twin 1D Code Only

Both Single & Twin

69 ** Exit Setup
Enter Setup

Code 128
Restore Factory Defaults

Restore the Factory Defaults of Code 128

Enable/Disable Code 128

** Enable Code 128

Disable Code 128

If the scanner fails to identify Code 128 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Code 128 barcode.

** Exit Setup 70
Enter Setup

Set Length Range for Code 128

The scanner can be configured to only decode Code 128 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 128
barcodes with either the minimum or maximum length. If minimum length is same as maximum length,
only Code 128 barcodes with that length are to be decoded.

Set the scanner to decode Code 128 barcodes containing between 8 and12 characters:
1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

71 ** Exit Setup
Enter Setup

EAN-8
Restore Factory Defaults

Restore the Factory Defaults of EAN-8

Enable/Disable EAN-8

** Enable EAN-8

Disable EAN-8

If the scanner fails to identify EAN-8 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable EAN-8 barcode.

Transmit Check Character

EAN-8 is 8 digits in length with the last one as its check character used to verify the integrity of the data.

** Transmit EAN-8 Check Character

Do Not Transmit EAN-8 Check Character

** Exit Setup 72
Enter Setup

2-Digit Add-On Code

An EAN-8 barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is a two-digit add-on code.

** Disable 2-Digit Add-On Code

Enable 2-Digit Add-On Code

Disable 2-Digit Add-On Code: The scanner decodes EAN-8 and ignores the add-on code when presented
with an EAN-8 plus 2-digit add-on barcode. It can also decode EAN-8 barcodes without 2-digit add-on
codes.
Enable 2-Digit Add-On Code: The scanner decodes a mix of EAN-8 barcodes with and without 2-digit
add-on codes.

73 ** Exit Setup
Enter Setup

5-Digit Add-On Code

An EAN-8 barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is a five-digit add-on code.

** Disable 5-Digit Add-On Code

Enable 5-Digit Add-On Code

Disable 5-Digit Add-On Code: The scanner decodes EAN-8 and ignores the add-on code when presented
with an EAN-8 plus 5-digit add-on barcode. It can also decode EAN-8 barcodes without 5-digit add-on
codes.
Enable 5-Digit Add-On Code: The scanner decodes a mix of EAN-8 barcodes with and without 5-digit
add-on codes.

** Exit Setup 74
Enter Setup

Convert EAN-8 to EAN-13

Convert EAN-8 to EAN-13: Convert EAN-8 decoded data to EAN-13 format before transmission. After conversion, the data
follows EAN-13 format and is affected by EAN-13 programming selections (e.g., Check Character).

Do Not Convert EAN-8 to EAN-13: EAN-8 decoded data is transmitted as EAN-8 data, without conversion.

** Do Not Convert EAN-8 to EAN-13

Convert EAN-8 to EAN-13

75 ** Exit Setup
Enter Setup

EAN-13
Restore Factory Defaults

Restore the Factory Defaults of EAN-13

Enable/Disable EAN-13

** Enable EAN-13

Disable EAN-13

If the scanner fails to identify EAN-13 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable EAN-13 barcode.

** Exit Setup 76
Enter Setup

Transmit Check Character

** Transmit EAN-13 Check Character

Do Not Transmit EAN-13 Check Character

2-Digit Add-On Code

An EAN-13 barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is a two-digit add-on code.

** Disable 2-Digit Add-On Code

Enable 2-Digit Add-On Code

Disable 2-Digit Add-On Code: The scanner decodes EAN-13 and ignores the add-on code when
presented with an EAN-13 plus 2-digit add-on barcode. It can also decode EAN-13 barcodes without 2-
digit add-on codes.
Enable 2-Digit Add-On Code: The scanner decodes a mix of EAN-13 barcodes with and without 2-digit
add-on codes.

77 ** Exit Setup
Enter Setup

5-Digit Add-On Code

An EAN-13 barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is a five-digit add-on code.

** Disable 5-Digit Add-On Code

Enable 5-Digit Add-On Code

Disable 5-Digit Add-On Code: The scanner decodes EAN-13 and ignores the add-on code when
presented with an EAN-13 plus 5-digit add-on barcode. It can also decode EAN-13 barcodes without 5-
digit add-on codes.
Enable 5-Digit Add-On Code: The scanner decodes a mix of EAN-13 barcodes with and without 5-digit
add-on codes.

** Exit Setup 78
Enter Setup

UPC-E
Restore Factory Defaults

Restore the Factory Defaults of UPC-E

Enable/Disable UPC-E

** Enable UPC-E

Disable UPC-E

If the scanner fails to identify UPC-E barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable UPC-E barcode.

Transmit Check Character

UPC-E is 8 digits in length with the last one as its check character used to verify the integrity of the data.

** Transmit UPC-E Check Character

Do Not Transmit UPC-E Check Character

79 ** Exit Setup
Enter Setup

2-Digit Add-On Code

A UPC-E barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is a two-digit add-on code.

** Disable 2-Digit Add-On Code

Enable 2-Digit Add-On Code

Disable 2-Digit Add-On Code: The scanner decodes UPC-E and ignores the add-on code when
presented with a UPC-E plus 2-digit add-on barcode. It can also decode UPC-E barcodes without 2-digit
add-on codes.
Enable 2-Digit Add-On Code: The scanner decodes a mix of UPC-E barcodes with and without 2-digit
add-on codes.

** Exit Setup 80
Enter Setup

5-Digit Add-On Code

A UPC-E barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is a five-digit add-on code.

** Disable 5-Digit Add-On Code

Enable 5-Digit Add-On Code

Disable 5-Digit Add-On Code: The scanner decodes UPC-E and ignores the add-on code when
presented with a UPC-E plus 5-digit add-on barcode. It can also decode UPC-E barcodes without 5-digit
add-on codes.
Enable 5-Digit Add-On Code: The scanner decodes a mix of UPC-E barcodes with and without 5-digit
add-on codes.

81 ** Exit Setup
Enter Setup

Transmit Preamble Character

Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E barcode. Select one of
the following options for transmitting UPC-E preamble to the host device: transmit system character only, transmit system
character and country code (“0” for USA), or transmit no preamble.

** System Character

No Preamble

System Character & Country Code

Convert UPC-E to UPC-A

Convert UPC-E to UPC-A: Convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After
conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check
Character).

Do Not Convert UPC-E to UPC-A: UPC-E decoded data is transmitted as UPC-E data, without conversion.

** Do Not Convert UPC-E to UPC-A

Convert UPC-E to UPC-A

** Exit Setup 82
Enter Setup

UPC-A
Restore Factory Defaults

Restore the Factory Defaults of UPC-A

Enable/Disable UPC-A

** Enable UPC-A

Disable UPC-A

If the scanner fails to identify UPC-A barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable UPC-A barcode.

Transmit Check Character

UPC-A is 13 digits in length with the last one as its check character used to verify the integrity of the data.

** Transmit UPC-A Check Character

Do Not Transmit UPC-A Check Character

83 ** Exit Setup
Enter Setup

2-Digit Add-On Code

A UPC-A barcode can be augmented with a two-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is a two-digit add-on code.

** Disable 2-Digit Add-On Code

Enable 2-Digit Add-On Code

Disable 2-Digit Add-On Code: The scanner decodes UPC-A and ignores the add-on code when
presented with a UPC-A plus 2-digit add-on barcode. It can also decode UPC-A barcodes without 2-digit
add-on codes.
Enable 2-Digit Add-On Code: The scanner decodes a mix of UPC-A barcodes with and without 2-digit
add-on codes.

** Exit Setup 84
Enter Setup

5-Digit Add-On Code

A UPC-A barcode can be augmented with a five-digit add-on code to form a new one. In the example below, the part
surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is a five-digit add-on code.

** Disable 5-Digit Add-On Code

Enable 5-Digit Add-On Code

Disable 5-Digit Add-On Code: The scanner decodes UPC-A and ignores the add-on code when
presented with a UPC-A plus 5-digit add-on barcode. It can also decode UPC-A barcodes without 5-digit
add-on codes.

Enable 5-Digit Add-On Code: The scanner decodes a mix of UPC-A barcodes with and without 5-digit
add-on codes.

85 ** Exit Setup
Enter Setup

Transmit Preamble Character

Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-A barcode. Select one of
the followingoptions for transmitting UPC-A preamble to the host device: transmit system character only or transmit system
character and country code (“0” for USA).

** No Preamble

System Character

System Character & Country Code

** Exit Setup 86
Enter Setup

Coupon
UPC-A/EAN-13 with Extended Coupon Code

The following three types of coupon code + extended coupon code are supported:

 UPC-A (starting with “5”) + GS1-128

 UPC-A (starting with “5”) + GS1 Databar

 EAN-13 (starting with “99”) + GS1-128

Use the appropriate barcode below to enable or disable UPC-A/EAN-13 with Extended Coupon Code. When left on the
default setting (Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.

If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a
single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads.

If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code
in a single read to transmit the data. No data is output unless both codes are read.

** Off

Allow Concatenation

Require Concatenation

When using the UPC-A Coupon feature, please ensure that System Character or System Character &
Country Code is selected for the “Transmit UPC-A Preamble Character” feature.

87 ** Exit Setup
Enter Setup

Coupon GS1 Databar Output

If you scan coupons that have both UPC and GS1 Databar codes, you may wish to scan and output only the data from the
GS1 Databar code. Scan the GS1 Output On barcode below to scan and output only the GS1 Databar code data.

When GS1 Output Off is selected, coupons that have both UPC and GS1 Databar codes are transmitted depending on
your selection for the “UPC-A/EAN-13 with Extended Coupon Code” feature.

** GS1 Output Off

GS1 Output On

When using the UPC-A Coupon feature, please ensure that System Character or System Character &
Country Code is selected for the “Transmit UPC-A Preamble Character” feature.

** Exit Setup 88
Enter Setup

Interleaved 2 of 5
Restore Factory Defaults

Restore the Factory Defaults of Interleaved 2 of 5

Enable/Disable Interleaved 2 of 5

** Enable Interleaved 2 of 5

Disable Interleaved 2 of 5

If the scanner fails to identify Interleaved 2 of 5 barcodes, you may first try this solution by scanning the
Enter Setup barcode and then Enable Interleaved 2 of 5 barcode.

89 ** Exit Setup
Enter Setup

Set Length Range for Interleaved 2 of 5

The scanner can be configured to only decode Interleaved 2 of 5 barcodes with lengths that fall between (inclusive) the
minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 6)

Set the Maximum Length (Default: 80)

If minimum length is set to be greater than maximum length, the scanner only decodes Interleaved 2 of 5
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
Interleaved 2 of 5 barcodes with that length are to be decoded.

Set the scanner to decode Interleaved 2 of 5 barcodes containing between 8 and12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 90
Enter Setup

Check Character Verification

A check character is optional for Interleaved 2 of 5 and can be added as the last character. It is a calculated value used to
verify the integrity of the data.

 Disable: The scanner transmits Interleaved 2 of 5 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Interleaved 2 of 5
barcodes to verify that the data complies with the check character algorithm. Barcodes passing the check will be
transmitted except the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Interleaved 2 of 5 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted,
whereas those failing it will not be transmitted.

Since Interleaved 2 of 5 must always have an even number of digits, a zero may need to be added as the first digit when
the check character is added. The check character is automatically generated when making Interleaved 2 of 5 barcodes.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Interleaved 2 of 5 barcodes
with a length that is less than the configured minimum length after having the check character excluded
will not be decoded. (For example, when the Do Not Transmit Check Character After Verificationoption
is enabled and the minimum length is set to 4, Interleaved 2 of 5 barcodes with a total length of 4 characters
including the check character cannot be read.)

91 ** Exit Setup
Enter Setup

ITF-14
ITF-14 is a special kind of Interleaved 2 of 5 with a length of 14 characters and the last character as the check character.

ITF-14 priority principle: Forthe Interleaved 2 of 5 barcodes with a length of 14 characters and the last character as the
check character, the ITF-14 configurations shall take precedence over the Interleaved 2 of 5 settings.

Restore Factory Defaults

Restore the Factory Defaults of ITF-14

Enable/Disable ITF-14

** Disable ITF-14

Enable ITF-14 But Do Not Transmit Check Character

Enable ITF-14 and Transmit Check Character

An example of the ITF-14 priority principle: when ITF-14 is enabled and Interleaved 2 of 5 is disabled, the
scanner only decodes Interleaved 2 of 5 barcodes with a length of 14 characters and the last character as
the check character.

** Exit Setup 92
Enter Setup

ITF-6
ITF-6 is a special kind of Interleaved 2 of 5 with a length of 6 characters and the last character as the check character.

ITF-6 priority principle: For the Interleaved 2 of 5 barcodes with a length of 6 characters and the last character as the check
character, the ITF-6 configurations shall take precedence over the Interleaved 2 of 5 settings.

Restore Factory Defaults

Restore the Factory Defaults of ITF-6

Enable/Disable ITF-6

** Disable ITF-6

Enable ITF-6 But Do Not Transmit Check Character

Enable ITF-6 and Transmit Check Character

An example of the ITF-6 priority principle: when ITF-6 is enabled and Interleaved 2 of 5 is disabled, the
scanner only decodes Interleaved 2 of 5 barcodes with a length of 6 characters and the last character as
the check character.

93 ** Exit Setup
Enter Setup

Matrix 2 of 5
Restore Factory Defaults

Restore the Factory Defaults of Matrix 2 of 5

Enable/Disable Matrix 2 of 5

** Enable Matrix 2 of 5

Disable Matrix 2 of 5

If the scanner fails to identify Matrix 2 of 5 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Matrix 2 of 5 barcode.

** Exit Setup 94
Enter Setup

Set Length Range for Matrix 2 of 5

The scanner can be configured to only decode Matrix 2 of 5 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 4)

Set the Maximum Length (Default: 80)

If minimum length is set to be greater than maximum length, the scanner only decodes Matrix 2 of 5
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
Matrix 2 of 5 barcodes with that length are to be decoded.

Set the scanner to decode Matrix 2 of 5 barcodes containing between 8 and12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

95 ** Exit Setup
Enter Setup

Check Character Verification

A check character is optional for Matrix 2 of 5 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.

 Disable: The scanner transmitsMatrix 2 of 5 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Matrix 2 of 5 barcodes
to verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted
except the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Matrix 2 of 5 barcodes to verify
that the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas
those failing it will not be transmitted.

Since Matrix 2 of 5 must always have an even number of digits, a zero may need to be added as the first digit when the
check character is added. The check character is automatically generated when making Matrix 2 of 5 barcodes.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Matrix 2 of 5 barcodes with
a length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Matrix 2 of 5 barcodes with a total length of 4 characters
including the check character cannot be read.)

** Exit Setup 96
Enter Setup

Code 39
Restore Factory Defaults

Restore the Factory Defaults of Code 39

Enable/Disable Code 39

** Enable Code 39

Disable Code 39

If the scanner fails to identify Code 39 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Code 39 barcode.

97 ** Exit Setup
Enter Setup

Set Length Range for Code 39

The scanner can be configured to only decode Code 39 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 39 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code 39
barcodes with that length are to be decoded.

Set the scanner to decode Code 39 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 98
Enter Setup

Check Character Verification

A check character is optional for Code 39 and can be added as the last character. It is a calculated value used to verify the
integrity of the data.

 Disable: The scanner transmitsCode 39 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Code 39 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted except
the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Code 39 barcodes to verify that
the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas those
failing it will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Code 39 barcodes with a
length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Code 39 barcodes with a total length of 4 characters including
the check character cannot be read.)

99 ** Exit Setup
Enter Setup

Transmit Start/Stop Character

Code 39 uses an asterisk (*) for both the start and the stop characters. You can choose whether or not to transmit the
start/stop characters by scanning the appropriate barcode below.

** Do Not Transmit Start/Stop Character

Transmit Start/Stop Character

Enable/Disable Code 39 Full ASCII

The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode below.

** Disable Code 39 Full ASCII

Enable Code 39 Full ASCII

** Exit Setup 100


Enter Setup

Enable/Disable Code 32 (Italian Pharma Code)

Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable
or disable Code 32. Code 39 must be enabled and Code 39 check character verification must be disabled for this parameter
to function.

** Disable Code 32

Enable Code 32

Code 32 Prefix

Scan the appropriate barcode below to enable or disable adding the prefix character “A” to all Code 32 barcodes. Code 32
must be enabled for this parameter to function.

** Disable Code 32 Prefix

Enable Code 32 Prefix

101 ** Exit Setup


Enter Setup

Transmit Code 32 Start/Stop Character

Code 32 must be enabled for this parameter to function.

** Do Not Transmit Code 32 Start/Stop Character

Transmit Code 32 Start/Stop Character

Transmit Code 32 Check Character

Code 32 must be enabled for this parameter to function.

** Do Not Transmit Code 32 Check Character

Transmit Code 32 Check Character

** Exit Setup 102


Enter Setup

Codabar
Restore Factory Defaults

Restore the Factory Defaults of Codabar

Enable/Disable Codabar

** Enable Codabar

Disable Codabar

If the scanner fails to identify Codabar barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Codabar barcode.

103 ** Exit Setup


Enter Setup

Set Length Range for Codabar

The scanner can be configured to only decode Codabar barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 2)

Set the Maximum Length (Default: 60)

If minimum length is set to be greater than maximum length, the scanner only decodes Codabar barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Codabar
barcodes with that length are to be decoded.

Set the scanner to decode Codabar barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 104


Enter Setup

Check Character Verification

A check character is optional for Codabar and can be added as the last character. It is a calculated value used to verify the
integrity of the data.

 Disable: The scanner transmits Codabar barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Codabar barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted except
the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Codabar barcodes to verify
that the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas
those failing it will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Codabar barcodes with a
length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Codabar barcodes with a total length of 4 characters including
the check character cannot be read.)

105 ** Exit Setup


Enter Setup

Start/Stop Character

You can set the start/stop characters and choose whether or not to transmit the start/stop characters by scanning the
appropriate barcode below.

** Do Not Transmit Start/Stop Character

Transmit Start/Stop Character

** ABCD/ABCD as the Start/Stop Character

ABCD/TN*E as the Start/Stop Character

abcd/abcd as the Start/Stop Character

abcd/tn*e as the Start/Stop Character

** Exit Setup 106


Enter Setup

Code 93
Restore Factory Defaults

Restore the Factory Defaults of Code 93

Enable/Disable Code 93

Enable Code 93

** Disable Code 93

If the scanner fails to identify Code 93 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Code 93 barcode.

107 ** Exit Setup


Enter Setup

Set Length Range for Code 93

The scanner can be configured to only decode Code 93 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 93 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code 93
barcodes with that length are to be decoded.

Set the scanner to decode Code 93 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 108


Enter Setup

Check Character Verification

Check characters are optional for Code 93 and can be added as the last two characters, which are calculated values used
to verify the integrity of the data.

 Disable: The scanner transmits Code 93 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Code 93 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the checks will be transmitted
except the last two digits, whereas those failing them will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Code 93 barcodes to verify that
the data complies with the check character algorithm. Barcodes passing the checks will be transmitted, whereas those
failing them will not be transmitted.

Disable

** Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Code 93 barcodes with a
length that is less than the configured minimum length after having the two check characters excluded will
not be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Code 93 barcodes with a total length of 4 characters including
the two check characters cannot be read.)

109 ** Exit Setup


Enter Setup

China Post 25
Restore Factory Defaults

Restore the Factory Defaults of China Post 25

Enable/Disable China Post 25

Enable China Post 25

** Disable China Post 25

If the scanner fails to identify China Post 25 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable China Post 25 barcode.

** Exit Setup 110


Enter Setup

Set Length Range for China Post 25

The scanner can be configured to only decode China Post 25 barcodes with lengths that fall between (inclusive) the
minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes China Post 25
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
China Post 25 barcodes with that length are to be decoded.

Set the scanner to decode China Post 25 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

111 ** Exit Setup


Enter Setup

Check Character Verification

A check character is optional for China Post 25 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.

 Disable: The scanner transmits China Post 25 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all China Post 25 barcodes
to verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted
except the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all China Post 25 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted,
whereas those failing it will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, China Post 25 barcodes
with a length that is less than the configured minimum length after having the check character excluded
will not be decoded. (For example, when the Do Not Transmit Check Character After Verification option
is enabled and the minimum length is set to 4, China Post 25 barcodes with a total length of 4 characters
including the check character cannot be read.)

** Exit Setup 112


Enter Setup

GS1-128 (UCC/EAN-128)
Restore Factory Defaults

Restore the Factory Defaults of GS1-128

Enable/Disable GS1-128

** Enable GS1-128

Disable GS1-128

If the scanner fails to identify GS1-128 barcodes, you may first try this solution by scanning the EnterSetup
barcode and then Enable GS1-128 barcode.

113 ** Exit Setup


Enter Setup

Set Length Range for GS1-128

The scanner can be configured to only decode GS1-128 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes GS1-128 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only GS1-128
barcodes with that length are to be decoded.

Set the scanner to decode GS1-128 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 114


Enter Setup

GS1 Databar (RSS)


Restore Factory Defaults

Restore the Factory Defaults of GS1 Databar

Enable/Disable GS1 Databar

** Enable GS1 Databar

Disable GS1 Databar

If the scanner fails to identify GS1 Databar barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable GS1 Databar barcode.

Transmit Application Identifier “01”

** Transmit Application Identifier“01”

Do Not Transmit Application Identifier“01”

115 ** Exit Setup


Enter Setup

GS1 Composite (EAN·UCC Composite)


Restore Factory Defaults

Restore the Factory Defaults of GS1 Composite

Enable/Disable GS1 Composite

Enable GS1 Composite

** Disable GS1 Composite

If the scanner fails to identify GS1 Composite barcodes, you may first try this solution by scanning the
Enter Setup barcode and then Enable GS1 Composite barcode.

Enable/Disable UPC/EAN Composite

Enable UPC/EAN Composite

** Disable UPC/EAN Composite

** Exit Setup 116


Enter Setup

Code 11
Restore Factory Defaults

Restore the Factory Defaults of Code 11

Enable/Disable Code 11

Enable Code 11

** Disable Code 11

If the scanner fails to identify Code 11 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Code 11 barcode.

117 ** Exit Setup


Enter Setup

Set Length Range for Code 11

The scanner can be configured to only decode Code 11 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 4)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 11 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code 11
barcodes with that length are to be decoded.

Set the scanner to decode Code 11 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 118


Enter Setup

Check Character Verification

Check characters are optional for Code 11 and can be added as the last one or two characters, which are calculated values
used to verify the integrity of the data.

If the Disable option is enabled, the scanner transmits Code 11 barcodes as is.

Disable

** One Check Character, MOD11

Two Check Characters, MOD11/MOD11

Two Check Characters, MOD11/MOD9

One Check Character, MOD11 (Len<=10)


Two Check Characters, MOD11/MOD11(Len>10)

One Check Character, MOD11 (Len<=10)


Two Check Characters, MOD11/MOD9 (Len>10)

119 ** Exit Setup


Enter Setup

Transmit Check Character

Do Not Transmit Code 11 Check Character

** Transmit Code 11 Check Character

If you select a check character algorithm and the Do Not Transmit Check Character option, Code 11
barcodes with a length that is less than the configured minimum length after having the check
character(s) excluded will not be decoded. (For example, when the One Check Character, MOD11 and
Do Not Transmit Check Character options are enabled and the minimum length is set to 4, Code 11
barcodes with a total length of 4 characters including the check character cannot be read.)

** Exit Setup 120


Enter Setup

ISBN
Restore Factory Defaults

Restore the Factory Defaults of ISBN

Enable/Disable ISBN

Enable ISBN

** Disable ISBN

If the scanner fails to identify ISBN barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable ISBN barcode.

121 ** Exit Setup


Enter Setup

Set ISBN Format

** ISBN-10

ISBN-13

** Exit Setup 122


Enter Setup

ISSN
Restore Factory Defaults

Restore the Factory Defaults of ISSN

Enable/Disable ISSN

Enable ISSN

** Disable ISSN

If the scanner fails to identify ISSN barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable ISSN barcode.

123 ** Exit Setup


Enter Setup

Industrial 25
Restore Factory Defaults

Restore the Factory Defaults of Industrial 25

Enable/Disable Industrial 25

Enable Industrial 25

** Disable Industrial 25

If the scanner fails to identify Industrial 25 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Industrial 25 barcode.

** Exit Setup 124


Enter Setup

Set Length Range for Industrial 25

The scanner can be configured to only decode Industrial 25 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 6)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Industrial 25
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
Industrial 25 barcodes with that length are to be decoded.

Set the scanner to decode Industrial 25 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

125 ** Exit Setup


Enter Setup

Check Character Verification

A check character is optional for Industrial 25 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.

 Disable: The scanner transmits Industrial 25 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Industrial 25 barcodes
to verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted
except the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Industrial 25 barcodes to verify
that the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas
those failing it will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Industrial 25 barcodes with
a length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Industrial 25 barcodes with a total length of 4 characters
including the check character cannot be read.)

** Exit Setup 126


Enter Setup

Standard 25
Restore Factory Defaults

Restore the Factory Defaults of Standard 25

Enable/Disable Standard 25

Enable Standard 25

** Disable Standard 25

If the scanner fails to identify Standard 25 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Standard 25 barcode.

127 ** Exit Setup


Enter Setup

Set Length Range for Standard 25

The scanner can be configured to only decode Standard 25 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 6)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Standard 25
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
Standard 25 barcodes with that length are to be decoded.

Set the scanner to decode Standard 25 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 128


Enter Setup

Check Character Verification

A check character is optional for Standard 25 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.

 Disable: The scanner transmits Standard 25 barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Standard 25 barcodes
to verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted
except the last digit, whereas those failing it will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Standard 25 barcodes to verify
that the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas
those failing it will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Standard 25 barcodes with
a length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Standard 25 barcodes with a total length of 4 characters
including the check character cannot be read.)

129 ** Exit Setup


Enter Setup

Plessey
Restore Factory Defaults

Restore the Factory Defaults of Plessey

Enable/Disable Plessey

Enable Plessey

** Disable Plessey

If the scanner fails to identify Plessey barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Plessey barcode.

** Exit Setup 130


Enter Setup

Set Length Range for Plessey

The scanner can be configured to only decode Plessey barcodes with lengths that fall between (inclusive) the minimum and
maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 4)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes Plessey barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Plessey
barcodes with that length are to be decoded.

Set the scanner to decode Plessey barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

131 ** Exit Setup


Enter Setup

Check Character Verification

Check characters are optional for Plessey and can be added as the last two characters, which are calculated values used
to verify the integrity of the data.

 Disable: The scanner transmits Plessey barcodes as is.

 Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Plessey barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the checks will be transmitted
except the last two digits, whereas those failing them will not be transmitted.

 Transmit Check Character After Verification: The scanner checks the integrity of all Plessey barcodes to verify that
the data complies with the check character algorithm. Barcodes passing the checks will be transmitted, whereas those
failing them will not be transmitted.

** Disable

Do Not Transmit Check Character After Verification

Transmit Check Character After Verification

If the Do Not Transmit Check Character After Verification option is enabled, Plessey barcodes with a
length that is less than the configured minimum length after having the check characters excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Plessey barcodes with a total length of 4 characters including
the check characters cannot be read.)

** Exit Setup 132


Enter Setup

MSI-Plessey
Restore Factory Defaults

Restore the Factory Defaults of MSI-Plessey

Enable/Disable MSI-Plessey

Enable MSI-Plessey

** Disable MSI-Plessey

If the scanner fails to identify MSI-Plessey barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable MSI-Plessey barcode.

133 ** Exit Setup


Enter Setup

Set Length Range for MSI-Plessey

The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 4)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey
barcodes with either the minimum or maximum length. If minimum length is same as maximum length, only
MSI-Plessey barcodes with that length are to be decoded.

Set the scanner to decode MSI-Plessey barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 134


Enter Setup

Check Character Verification

Check characters are optional for MSI-Plessey and can be added as the last one or two characters, which are calculated
values used to verify the integrity of the data.

If the Disable option is enabled, the scanner transmits MSI-Plessey barcodes as is.

Disable

** One Check Character, MOD10

Two Check Characters, MOD10/MOD10

Two Check Characters, MOD10/MOD11

135 ** Exit Setup


Enter Setup

Transmit Check Character

** Transmit MSI-Plessey Check Character

Do Not Transmit MSI-Plessey Check Character

If you select a check character algorithm and the Do Not Transmit Check Character option, MSI-Plessey
barcodes with a length that is less than the configured minimum length after having the check character(s)
excluded will not be decoded. (For example, when the One Check Character, MOD10 and Do Not
Transmit Check Character options are enabled and the minimum length is set to 4, MSI-Plessey barcodes
with a total length of 4 characters including the check character cannot be read.)

** Exit Setup 136


Enter Setup

AIM 128
Restore Factory Defaults

Restore the Factory Defaults of AIM 128

Enable/Disable AIM 128

Enable AIM 128

** Disable AIM 128

If the scanner fails to identify AIM 128 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable AIM 128 barcode.

137 ** Exit Setup


Enter Setup

Set Length Range for AIM 128

The scanner can be configured to only decode AIM 128 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 48)

If minimum length is set to be greater than maximum length, the scanner only decodes AIM 128 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only AIM 128
barcodes with that length are to be decoded.

Set the scanner to decode AIM 128 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 138


Enter Setup

ISBT 128
Restore Factory Defaults

Restore the Factory Defaults of ISBT 128

Enable/Disable ISBT 128

Enable ISBT 128

** Disable ISBT 128

If the scanner fails to identify ISBT 128 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable ISBT 128 barcode.

139 ** Exit Setup


Enter Setup

Code 49
Restore Factory Defaults

Restore the Factory Defaults of Code 49

Enable/Disable Code 49

Enable Code 49

** Disable Code 49

If the scanner fails to identify Code 49 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable Code 49 barcode.

** Exit Setup 140


Enter Setup

Set Length Range for Code 49

The scanner can be configured to only decode Code 49 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 80)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 49 barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code 49
barcodes with that length are to be decoded.

Set the scanner to decode Code 49 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

141 ** Exit Setup


Enter Setup

Code 16K
Restore Factory Defaults

Restore the Factory Defaults of Code 16K

Enable/Disable Code 16K

Enable Code 16K

** Disable Code 16K

If the scanner fails to identify Code 16K barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Code 16K barcode.

** Exit Setup 142


Enter Setup

Set Length Range for Code 16K

The scanner can be configured to only decode Code 16K barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 80)

If minimum length is set to be greater than maximum length, the scanner only decodes Code 16K barcodes
with either the minimum or maximum length. If minimum length is same as maximum length, only Code
16K barcodes with that length are to be decoded.

Set the scanner to decode Code 16K barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

143 ** Exit Setup


Enter Setup

PDF417
Restore Factory Defaults

Restore the Factory Defaults of PDF417

Enable/Disable PDF417

** Enable PDF417

Disable PDF417

If the scanner fails to identify PDF417 barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable PDF417 barcode.

** Exit Setup 144


Enter Setup

Set Length Range for PDF417

The scanner can be configured to only decode PDF417 barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 2710)

Minimum length is not allowed to be greater than maximum length. If you only want to read PDF417
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode PDF417 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

145 ** Exit Setup


Enter Setup

PDF417 Twin Code

PDF417 twin code is 2 PDF417 barcodes paralleled vertically or horizontally. They must both be either regular or inverse
barcodes. They must have similar specifications and be placed closely together.

There are 3 options for reading PDF417 twin codes:

 Single PDF417 Only: Read either PDF417 code.

 Twin PDF417 Only: Read both PDF417 codes.

 Both Single & Twin: Read both PDF417 codes. If successful, transmit as twin PDF417 only. Otherwise, try single
PDF417 only.

** Single PDF417 Only

Twin PDF417 Only

Both Single & Twin

** Exit Setup 146


Enter Setup

PDF417 Inverse

Regular barcode: Dark bars on a bright background.

Inverse barcode: Bright bars on a dark background.

** Decode Regular PDF417 Barcodes Only

Decode Inverse PDF417 Barcodes Only

Decode Both

Character Encoding

** Default Character Encoding

UTF-8

147 ** Exit Setup


Enter Setup

PDF417 ECI Output

Disable PDF417 ECI Output

** Enable PDF417 ECI Output

** Exit Setup 148


Enter Setup

Micro PDF417
Restore Factory Defaults

Restore the Factory Defaults of Micro PDF417

Enable/Disable Micro PDF417

Enable Micro PDF417

** Disable Micro PDF417

If the scanner fails to identify Micro PDF417 barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Micro PDF417 barcode.

149 ** Exit Setup


Enter Setup

Set Length Range for Micro PDF417

The scanner can be configured to only decode Micro PDF417 barcodes with lengths that fall between (inclusive) the
minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 366)

Minimum length is not allowed to be greater than maximum length. If you only want to read Micro PDF417
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Micro PDF417 barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 150


Enter Setup

QR Code
Restore Factory Defaults

Restore the Factory Defaults of QR Code

Enable/Disable QR Code

** Enable QR Code

Disable QR Code

If the scanner fails to identify QR Code barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable QR Code barcode.

151 ** Exit Setup


Enter Setup

Set Length Range for QR Code

The scanner can be configured to only decode QR Code barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 7089)

Minimum length is not allowed to be greater than maximum length. If you only want to read QR Code
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode QR Code barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 152


Enter Setup

QR Twin Code

QR twin code is 2 QR barcodes paralleled vertically or horizontally. They must both be either regular or inverse barcodes.
They must have similar specifications and be placed closely together.

There are 3 options for reading QR twin codes:

 Single QR Only: Read either QR code.

 Twin QR Only: Read both QR codes. Transmission sequence: left (upper) QR code followed by right (lower) QR code.

 Both Single & Twin: Read both QR codes. If successful, transmit as twin QR only. Otherwise, try single QR only.

** Single QR Only

Twin QR Only

Both Single & Twin

153 ** Exit Setup


Enter Setup

QR Inverse

Regular barcode: Dark bars on a bright background.

Inverse barcode: Bright bars on a dark background.

** Decode Regular QR Barcodes Only

Decode Inverse QR Barcodes Only

Decode Both

Character Encoding

** Default Character Encoding

UTF-8

** Exit Setup 154


Enter Setup

QR ECI Output

Disable QR ECI Output

** Enable QR ECI Output

155 ** Exit Setup


Enter Setup

Micro QR Code
Restore Factory Defaults

Restore the Factory Defaults of Micro QR

Enable/Disable Micro QR

** Enable Micro QR

Disable Micro QR

If the scanner fails to identify Micro QR barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Micro QR barcode.

** Exit Setup 156


Enter Setup

Set Length Range for Micro QR

The scanner can be configured to only decode Micro QR barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 35)

Minimum length is not allowed to be greater than maximum length. If you only want to read Micro QR
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Micro QR Code barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

157 ** Exit Setup


Enter Setup

Aztec
Restore Factory Defaults

Restore the Factory Defaults of Aztec Code

Enable/Disable Aztec Code

Enable Aztec Code

** Disable Aztec Code

If the scanner fails to identify Aztec Code barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Aztec Code barcode.

** Exit Setup 158


Enter Setup

Set Length Range for Aztec Code

The scanner can be configured to only decode Aztec barcodes with lengths that fall between (inclusive) the minimum and
maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 3832)

Minimum length is not allowed to be greater than maximum length. If you only want to read Aztec barcodes
with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Aztec barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

159 ** Exit Setup


Enter Setup

Read Multi-barcodes on an Image

There are three options:

 Mode 1: Read one barcode only.

 Mode 2: Read fixed number of barcodes only.

 Mode 3: Composite Reading. Read fixed number of barcodes first. If unsuccessful, read one barcode only.

** Mode 1

Mode 2

Mode 3

** Exit Setup 160


Enter Setup

Set the Number of Barcodes

** 1

161 ** Exit Setup


Enter Setup

Character Encoding

** Default Character Encoding

UTF-8

Aztec ECI Output

Disable Aztec ECI Output

** Enable Aztec ECI Output

** Exit Setup 162


Enter Setup

Data Matrix
Restore Factory Defaults

Restore the Factory Defaults of Data Matrix

Enable/Disable Data Matrix

** Enable Data Matrix

Disable Data Matrix

If the scanner fails to identify Data Matrix barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Data Matrix barcode.

163 ** Exit Setup


Enter Setup

Set Length Range for Data Matrix

The scanner can be configured to only decode Data Matrix barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 3116)

Minimum length is not allowed to be greater than maximum length. If you only want to read Data Matrix
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Data Matrix barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

** Exit Setup 164


Enter Setup

Data Matrix Twin Code

Data Matrix twin code is 2 Data Matrix barcodes paralleled vertically or horizontally. They must both be either regular or
inverse barcodes. They must have similar specifications and be placed closely together.

There are 3 options for reading Data Matrix twin codes:

 Single Data Matrix Only: Read either Data Matrix code.

 Twin Data Matrix Only: Read both Data Matrix codes. Transmission sequence: left (upper) Data Matrix code followed
by right (lower) Data Matrix code.

 Both Single & Twin: Read both Data Matrix codes. If successful, transmit as twin Data Matrix only. Otherwise, try
single Data Matrix only.

** Single Data Matrix Only

Twin Data Matrix Only

Both Single & Twin

165 ** Exit Setup


Enter Setup

Rectangular Barcode

Data Matrix has two formats:

Square barcodes having the same amount of modules in length and width: 10*10, 12*12.... 144*144.

Rectangular barcodes having different amounts of models in length and width: 6*16, 6*14...14*22.

** Enable Rectangular Barcode

Disable Rectangular Barcode

Data Matrix Inverse

Regular barcode: Dark bars on a bright background.

Inverse barcode: Bright bars on a dark background.

** Decode Regular Data Matrix Barcodes Only

Decode Inverse Data Matrix Barcodes Only

Decode Both

** Exit Setup 166


Enter Setup

Character Encoding

** Default Character Encoding

UTF-8

Data Matrix ECI Output

Disable Data Matrix ECI Output

** Enable Data Matrix ECI Output

167 ** Exit Setup


Enter Setup

Maxicode
Restore Factory Defaults

Restore the Factory Defaults of Maxicode

Enable/Disable Maxicode

Enable Maxicode

** Disable Maxicode

If the scanner fails to identify Maxicode barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Maxicode barcode.

** Exit Setup 168


Enter Setup

Set Length Range for Maxicode

The scanner can be configured to only decode Maxicode barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default:150)

Minimum length is not allowed to be greater than maximum length. If you only want to read Maxicode
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Maxicode barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

169 ** Exit Setup


Enter Setup

Chinese Sensible Code


Restore Factory Defaults

Restore the Factory Defaults of Chinese Sensible Code

Enable/Disable Chinese Sensible Code

Enable Chinese Sensible Code

** Disable Chinese Sensible Code

If the scanner fails to identify Chinese Sensible Code barcodes, you may first try this solution by scanning
the Enter Setup barcode and then Enable Chinese Sensible Code barcode.

** Exit Setup 170


Enter Setup

Set Length Range for Chinese Sensible Code

The scanner can be configured to only decode Chinese Sensible Code barcodes with lengths that fall between (inclusive)
the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 7827)

Minimum length is not allowed to be greater than maximum length. If you only want to read Chinese
Sensible Code barcodes with a specific length, set both minimum and maximum lengths to be that desired
length.

Set the scanner to decode Chinese Sensible Code barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

171 ** Exit Setup


Enter Setup

Chinese Sensible Twin Code

Chinese Sensible twin code is 2 Chinese Sensible barcodes paralleled vertically or horizontally. They must both be either
regular or inverse barcodes. They must have similar specifications and be placed closely together.

There are 3 options for reading Chinese Sensible twin codes:

 Single Chinese Sensible Code Only: Read either Chinese Sensible code.

 Twin Chinese Sensible Code Only: Read both Chinese Sensible codes. Transmission sequence: left (upper)
Chinese Sensible code followed by right (lower) Chinese Sensible code.

 Both Single & Twin: Read both Chinese Sensible codes. If successful, transmit as twin Chinese Sensible Code only.
Otherwise, try single Chinese Sensible Code only.

** Single Chinese Sensible Code Only

Twin Chinese Sensible Code Only

Both Single & Twin

** Exit Setup 172


Enter Setup

Chinese Sensible Code Inverse

Regular barcode: Dark bars on a bright background.

Inverse barcode: Bright bars on a dark background.

** Decode Regular Chinese Sensible Barcodes Only

Decode Inverse Chinese Sensible Barcodes Only

Decode Both

173 ** Exit Setup


Enter Setup

GM Code
Restore Factory Defaults

Restore the Factory Defaults of GM

Enable/Disable GM

Enable GM

** Disable GM

If the scanner fails to identify GM barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable GM barcode.

** Exit Setup 174


Enter Setup

Set Length Range for GM

The scanner can be configured to only decode GM barcodes with lengths that fall between (inclusive) the minimum and
maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 2751)

Minimum length is not allowed to be greater than maximum length. If you only want to read GM barcodes
with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode GM barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

175 ** Exit Setup


Enter Setup

Code One
Restore Factory Defaults

Restore the Factory Defaults of Code One

Enable/Disable Code One

Enable Code One

** Disable Code One

If the scanner fails to identify Code One barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Code One barcode.

** Exit Setup 176


Enter Setup

Set Length Range for Code One

The scanner can be configured to only decode Code One barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.

Set the Minimum Length (Default: 1)

Set the Maximum Length (Default: 3550)

Minimum length is not allowed to be greater than maximum length. If you only want to read Code One
barcodes with a specific length, set both minimum and maximum lengths to be that desired length.

Set the scanner to decode Code One barcodes containing between 8 and 12 characters:

1. Scan the Enter Setup barcode.

2. Scan the Set the Minimum Length barcode.

3. Scan the numeric barcode “8” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Set the Maximum Length barcode.

6. Scan the numeric barcodes “1” and “2” from the “Digit Barcodes” section in Appendix.

7. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

8. Scan the Exit Setup barcode.

177 ** Exit Setup


Enter Setup

USPS Postnet
Restore Factory Defaults

Restore the Factory Defaults of USPS Postnet

Enable/Disable USPS Postnet

Enable USPS Postnet

** Disable USPS Postnet

If the scanner fails to identify USPS Postnet barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable USPS Postnet barcode.

Transmit Check Character

Do Not Transmit USPS Postnet Check Character

** Transmit USPS Postnet Check Character

** Exit Setup 178


Enter Setup

USPS Intelligent Mail


Restore Factory Defaults

Restore the Factory Defaults of USPS Intelligent Mail

Enable/Disable USPS Intelligent Mail

Enable USPS Intelligent Mail

** Disable USPS Intelligent Mail

If the scanner fails to identify USPS Intelligent Mail barcodes, you may first try this solution by scanning
the Enter Setup barcode and then Enable USPS Intelligent Mail barcode.

179 ** Exit Setup


Enter Setup

Royal Mail
Restore Factory Defaults

Restore the Factory Defaults of Royal Mail

Enable/Disable Royal Mail

Enable Royal Mail

** Disable Royal Mail

If the scanner fails to identify Royal Mail barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Royal Mail barcode.

** Exit Setup 180


Enter Setup

USPS Planet
Restore Factory Defaults

Restore the Factory Defaults of USPS Planet

Enable/Disable USPS Planet

Enable USPS Planet

** Disable USPS Planet

If the scanner fails to identify USPS Planet barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable USPS Planet barcode.

Transmit Check Character

Do Not Transmit USPS Planet Check Character

** Transmit USPS Planet Check Character

181 ** Exit Setup


Enter Setup

KIX Post
Restore Factory Defaults

Restore the Factory Defaults of KIX Post

Enable/Disable KIX Post

Enable KIX Post

** Disable KIX Post

If the scanner fails to identify KIX Post barcodes, you may first try this solution by scanning the Enter Setup
barcode and then Enable KIX Post barcode.

** Exit Setup 182


Enter Setup

Australian Postal
Restore Factory Defaults

Restore the Factory Defaults of Australian Postal

Enable/Disable Australian Postal

Enable Australian Postal

** Disable Australian Postal

If the scanner fails to identify Australian Postal barcodes, you may first try this solution by scanning the
Enter Setup barcode and then Enable Australian Postal barcode.

183 ** Exit Setup


Enter Setup

Specific OCR-B
Restore Factory Defaults

Restore the Factory Defaults of Specific OCR-B

Enable/Disable Specific OCR-B

Enable Specific OCR-B

** Disable Specific OCR-B

If the scanner fails to identify Specific OCR-B barcodes, you may first try this solution by scanning the
Enter Setup barcode and then Enable Specific OCR-B barcode.

** Exit Setup 184


Enter Setup

Passport OCR
Restore Factory Defaults

Restore the Factory Defaults of Passport OCR

Enable/Disable Passport OCR

Enable Passport OCR

** Disable Passport OCR

If the scanner fails to identify Passport OCR barcodes, you may first try this solution by scanning the Enter
Setup barcode and then Enable Passport OCR barcode.

185 ** Exit Setup


Enter Setup

Chapter 6 Data Formatter

Introduction
You may use the Data Formatter to modify the scanner’s output. For example, you can use the Data Formatter to insert
characters at certain points in barcode data or to suppress/ replace/ send certain characters in barcode data as it is scanned.

Normally, when you scan a barcode, it gets outputted automatically; however, when you create a format, you must use a
“send” command (see the “Send Commands” section in this chapter) within the format programming to output data. The
maximum size of formatter commands in a data format is 500 characters. By default, the data formatter is disabled. Enable
it when required. If you have changed data format settings, and wish to clear all formats and return to the factory defaults,
scan the Default Data Format code below.

Default Data Format

Add a Data Format


Data format is used to edit barcode data only. You can program up to four data formats, i.e. Format_0, Format_1, Format_2
and Format_3. When you create a data format, you must specify the application scope of your data format (such as barcode
type and data length) and include formatter commands. When scanned data does not match your data format requirements,
you will hear the non-match error beep (if the non-match error beep is ON).

The following explains how to program a data format by scanning the specific barcodes. Scanning any irrelevant barcode
or failing to follow the setting procedure will result in programming failure. To find the alphanumeric barcodes needed to
create a data format, see the “Digit Barcodes” section in Appendix.

Step 1: Scan the Enter Setup barcode.

Step 2: Scan the Add Data Format barcode.

Add Data Format

** Exit Setup 186


Enter Setup

Step 3: Select data format.


Scan a numeric barcode 0 or 1 or 2 or 3 to set this to Format_0 or Format_1 or Format_2 or Format_3.

Step 4: Select formatter command type.


Specify what type of formatter commands will be used. Scan a numeric barcode “6” to select formatter command type 6.
(See the “Formatter Command Type 6” section in this chapter for more information)

Step 5: Set interface type


Scan 999 for any interface type.

Step 6: Set Symbology ID Number


Refer to the “Symbology ID Number” section in Appendix and find the ID number of the symbology to which you want to
apply the data format. Scan three numeric barcodes for the symbology ID number. If you wish to create a data format for all
symbologies, scan 999.

Step 7: Set barcode data length


Specify what length of data will be acceptable for this symbology. Scan the four numeric barcodes that represent the data
length. 9999 is a universal number, indicating all lengths. For example, 32 characters should be entered as 0032.

Step 8: Enter formatter command


Refer to the “Formatter Command Type 6” section in this chapter. Scan the alphanumeric barcodes that represent the
command you need to edit data. For example, when a command is F141, you should scan F141. A command can contain
up to 500 characters.

Step 9: Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix to save your data format.

Example: Program format_0 using formatter command type 6, Code 128 containing 10 characters applicable, send all
characters followed by “A”.

1. Scan the Enter Setup barcode Enter the Setup mode

2. Scan the Add Data Format barcode Add a data format

3. Scan the 0 barcode Select format_0

4. Scan the 6 barcode Select formatter command type 6

5. Scan the 9 barcode three times All interface types applicable

6. Scan the barcodes 002 Only Code 128 applicable

7. Scan the barcodes 0010 Only a length of 10 characters applicable

8. Scan the alphanumeric barcodes F141 Send all characters followed by “A” (HEX: 41)

9. Scan the Save barcode Save the data format

187 ** Exit Setup


Enter Setup

To streamline the programming process, you may as well generate a batch barcode by inputting the command (e.g.
@DFMSET069990020010F141;) used to create a data format. See the “Use Batch Barcode” section in Chapter 9 to learn
how to put a batch barcode into use.

** Exit Setup 188


Enter Setup

Enable/Disable Data Formatter


When Data Formatter is disabled, the data format you have enabled becomes invalid.

** Disable Data Formatter

You may wish to require the data to conform to a data format you have created. The following settings can be applied to
your data format:

Enable Data Formatter, Required, Keep Prefix/Suffix: Scanned data that meets your data format requirements is
modified accordingly and gets outputted along with prefixes and suffixes (if prefix and suffix are enabled). Any data that
does not match your data format requirements generates an error beep (if Non-Match Error Beep is turned ON) and the
data in that barcode is not transmitted.

Enable Data Formatter, Required, Drop Prefix/Suffix: Scanned data that meets your data format requirements is modified
accordingly and gets outputted without prefixes and suffixes (even if prefix and suffix are enabled). Any data that does not
match your data format requirements generates an error beep (if Non-Match Error Beep is turned ON) and the data in that
barcode is not transmitted.

Enable Data Formatter, Not Required, Keep Prefix/Suffix: Scanned data that meets your data format requirements is
modified accordingly and gets outputted along with prefixes and suffixes (if prefix and suffix are enabled). Barcode data that
does not match your data format requirements is transmitted as read along with prefixes and suffixes (if prefix and suffix are
enabled).

Enable Data Formatter, Not Required, Drop Prefix/Suffix: Scanned data that meets your data format requirements is
modified accordingly and gets outputted without prefixes and suffixes (even if prefix and suffix are enabled). Barcode data
that does not match your data format requirements is transmitted as read along with prefixes and suffixes (if prefix and suffix
are enabled).

189 ** Exit Setup


Enter Setup

Enable Data Formatter, Required, Keep Prefix/Suffix

Enable Data Formatter, Required, Drop Prefix/Suffix

Enable Data Formatter, Not Required, Keep Prefix/Suffix

Enable Data Formatter, Not Required, Drop Prefix/Suffix

Non-Match Error Beep


If Non-Match Error Beep is turned ON, the scanner generates an error beep when a barcode is encountered that does not
match your required data format.

Non-Match Error Beep Off

** Non-Match Error Beep On

** Exit Setup 190


Enter Setup

Multiple Data Formats


After the Data Formatter is enabled, you can set the scanner to use one or multiple data formats by scanning the appropriate
barcode below.

Multiple Data Formats Off: Only one data format (default: Format_0) is put into use. To learn how to switch to another
data format, see the “Data Format Selection” section below.

Multiple Data Formats On: The scanner toggles from Format_0 through Format_3 until scanned data matches the
requirements of one data format. If no match is found, the scanner generates an error beep (if Non-Match Error Beep is
turned ON) and the data is not transmitted.

** Multiple Formats Off

Multiple Formats On

191 ** Exit Setup


Enter Setup

Data Format Selection


You can select a data format you want to use by scanning the appropriate barcode below. Note that this setting is valid only
when the Multiple Data Formats feature is turned off.

** Format_0

Format_1

Format_2

Format_3

** Exit Setup 192


Enter Setup

Change Data Format for a Single Scan


You can switch between data formats for a single scan. The next barcode is scanned using the data format selected here,
then reverts to the format you have selected above. This setting is valid only when the Multiple Data Formats feature is
turned off.

For example, you may have set your scanner to use the data format you saved as Format_3. You can switch to Format_1
for a single trigger pull by scanning the Single Scan – Format_1 barcode below. The next barcode that is scanned uses
Format_1, then reverts back to Format_3.

Note: This setting will be lost by removing power from the scanner, or turning off/ rebooting the device.

Single Scan – Format_0

Single Scan – Format_1

Single Scan – Format_2

Single Scan – Format_3

193 ** Exit Setup


Enter Setup

Clear Data Format


There are two methods to remove data format created from your scanner:

Delete one data format: Scan the Clear One barcode, a numeric barcode (0-3) and the Save barcode. For example, to
delete Format_2, you should scan the Clear One barcode, the 2 barcode and the Save barcode

Delete all data formats: Scan the Clear All barcode.

Clear All

Clear One

Query Data Formats


You may scan the appropriate barcode below to get the information of data format(s) created by you or preset by
manufacturer. For instance, if you have added Format_0 as per the example in the “Add a Data Format” section in this
chapter, scanning the Query Current Data Formats barcode, you will get the result: Data Format0:069990020010F141;.

Query Current Data Formats

Query Preset Data Formats

** Exit Setup 194


Enter Setup

Formatter Command Type 6


When working with the Data Formatter, a virtual cursor is moved along your input data string. The following commands are
used to both move this cursor to different positions, and to select, replace, and insert data into the final output. For the hex
value of ASCII characters involved in the commands, refer to the “ASCII Table” in Appendix.

Send Commands

F1 Send all characters

Syntax=F1xx (xx: The insert character’s hex value)


Include in the output message all of the characters from the input message, starting from current cursor position, followed
by an insert character.

F2 Send a number of characters

Syntax=F2nnxx (nn: The numeric value (00-99) for the number of characters; xx: The insert character’s hex value)

Include in the output message a number of characters followed by an insert character. Start from the current cursor position
and continue for “nn” characters or through the last character in the input message, followed by character “xx.”

F2 Example: Send a number of characters

Send the first 10 characters from the barcode above, followed by a carriage return.

Command string: F2100D

F2 is the “Send a number of characters” command

10 is the number of characters to send

0D is the hex value for a CR

The data is output as: 1234567890


<CR>

195 ** Exit Setup


Enter Setup

F3 Send all characters up to a particular character

Syntax=F3ssxx (ss: The particular character’s hex value; xx: The insert character’s hex value)

Include in the output message all characters from the input message, starting with the character at the current cursor position
and continuing to, but not including, the particular character “ss,” followed by character “xx.” The cursor is moved forward
to the “ss” character.

F3 Example: Send all characters up to a particular character

Using the barcode above, send all characters up to but not including “D,” followed by a carriage return.

Command string: F3440D

F3 is the “Send all characters up to a particular character” command

44 is the hex value for a “D”

0D is the hex value for a CR

The data is output as: 1234567890ABC


<CR>

E9 Send all but the last characters

Syntax=E9nn (nn: The numeric value (00-99) for the number of characters that will not be sent at the end of the message)

Include in the output message all but the last “nn” characters, starting from the current cursor position. The cursor is moved
forward to one position past the last input message character included.

F4 Insert a character multiple times

Syntax=F4xxnn (xx: The insert character’s hex value; nn: The numeric value (00-99) for the number of times it should be
sent)

Send “xx” character “nn” times in the output message, leaving the cursor in the current position.

** Exit Setup 196


Enter Setup

E9 and F4 Example: Send all but the last characters, followed by 2 tabs

Send all characters except for the last 8 from the barcode above, followed by 2 tabs.

Command string: E908F40902

E9 is the “Send all but the last characters” command

08 is the number of characters at the end to ignore

F4 is the “Insert a character multiple times” command

09 is the hex value for a horizontal tab

02 is the number of time the tab character is sent

The data is output as: 1234567890AB<tab><tab>

B3 Insert symbology name

Insert the name of the barcode’s symbology in the output message, without moving the cursor.

B4 Insert barcode length

Insert the barcode’s length in the output message, without moving the cursor. The length is expressed as a numeric string
and does not include leading zeros.

197 ** Exit Setup


Enter Setup

B3 and B4 Example: Insert the symbology name and length

Send the symbology name and length before the barcode data from the barcode above. Break up these insertions with
spaces. End with a carriage return.

Command string: B3F42001B4F42001F10D

B3 is the “Insert symbology name” command

F4 is the “Insert a character multiple times” command

20 is the hex value for a space

01 is the number of time the space character is sent

B4 is the “Insert barcode length” command

F4 is the “Insert a character multiple times” command

20 is the hex value for a space

01 is the number of time the space character is sent

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: Code128 20 1234567890ABCDEFGHIJ


<CR>

Move Commands

F5 Move the cursor forward a number of characters

Syntax=F5nn (nn: The numeric value (00-99) for the number of characters the cursor should be moved ahead)

Move the cursor ahead “nn” characters from current cursor position.

** Exit Setup 198


Enter Setup

F5 Example: Move the cursor forward and send the data

Move the cursor forward 3 characters, then send the rest of the barcode data from the barcode above. End with a carriage
return.

Command string: F503F10D

F5 is the “Move the cursor forward a number of characters” command

03 is the number of characters to move the cursor

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 4567890ABCDEFGHIJ


<CR>

F6 Move the cursor backward a number of characters

Syntax=F6nn (nn: The numeric value (00-99) for the number of characters the cursor should be moved back)

Move the cursor back “nn” characters from current cursor position.

F7 Move the cursor to the beginning

Syntax=F7

Move the cursor to the first character in the input message.

EA Move the cursor to the end

Syntax=EA

Move the cursor to the last character in the input message.

199 ** Exit Setup


Enter Setup

Search Commands

F8 Search forward for a character

Syntax=F8xx (xx: The search character’s hex value)

Search the input message forward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx”
character.

F8 Example: Send barcode data that starts after a particular character

Search for the letter “D” in barcodes and send all the data that follows, including the “D”. Using the barcode above:

Command string: F844F10D

F8 is the “Search forward for a character” command

44 is the hex value for “D”

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: DEFGHIJ

<CR>

F9 Search backward for a character

Syntax=F9xx(xx: The search character’s hex value)

Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the
“xx” character.

** Exit Setup 200


Enter Setup

B0 Search forward for a string

Syntax=B0nnnnS (nnnn: The string length (up to 9999); S: The ASCII hex value of each character in the string)

Search forward for “S” string from the current cursor position, leaving cursor pointing to “S” string. For example,
B0000454657374 will search forward for the first occurrence of the 4-character string “Test.”

B0 Example: Send barcode data that starts after a string of characters

Search for the letters “FGH” in barcodes and send all the data that follows, including “FGH.” Using the barcode above:

Command string: B00003464748F10D

B0 is the “Search forward for a string” command

0003 is the string length (3 characters)

46 is the hex value for “F”

47 is the hex value for “G”

48 is the hex value for “H”

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: FGHIJ


<CR>

B1 Search backward for a string

Syntax=B1nnnnS (nnnn: The string length (up to 9999); S: The ASCII hex value of each character in the string)

Search backward for “S” string from the current cursor position, leaving cursor pointing to “S” string. For example,
B1000454657374 will search backward for the first occurrence of the 4-character string “Test.”

201 ** Exit Setup


Enter Setup

E6 Search forward for a non-matching character

Syntax=E6xx (xx: The search character’s hex value)

Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing
to the non-“xx” character.

E6 Example: Remove zeros at the beginning of barcode data

This example shows a barcode that has been zero filled. You may want to ignore the zeros and send all the data that follows.
E6 searches forward for the first character that is not zero, then sends all the data after, followed by a carriage return. Using
the barcode above:

Command string: E630F10D

E6 is the “Search forward for a non-matching character” command

30 is the hex value for 0

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 37692

<CR>

E7 Search backward for a non-matching character

Syntax=E7xx(xx: The search character’s hex value)

Search the input message backward for the first non-“xx” character from the current cursor position, leaving the cursor
pointing to the non-“xx” character.

** Exit Setup 202


Enter Setup

Miscellaneous Commands

FB Suppress characters

Syntax=FBnnxxyy..zz (nn: The numeric value (00-15) for the number of suppressed characters; xxyy..zz: The hex value of
the characters to be suppressed)

Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced
by other commands.

FB Example: Remove spaces in barcode data

This example shows a barcode that has spaces in the data. You may want to remove the spaces before sending the data.
Using the barcode above:

Command string: FB0120F10D

FB is the “Suppress characters” command

01 is the number of the characters to be suppressed

20 is the hex value for a space

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 34567890

<CR>

E4 Replace characters

Syntax = E4nnxx1xx2yy1yy2…zz1zz2(nn: The total count of the number of characters (characters to be replaced plus
replacement characters; xx1: The characters to be replaced, xx2: The replacement characters, continuing through zz1 and
zz2)

Replace up to 15 characters in the output message, without moving the cursor.

203 ** Exit Setup


Enter Setup

E4 Example: Replace zeros with CRs in barcode data

If the barcode has characters that the host application does not want included, you can use the E4 command to replace
those characters with something else. In this example, you will replace the zeros in the barcode above with carriage returns.

Command string: E402300DF10D

E4 is the “Replace characters” command

02 is the total count of characters to be replaced, plus the replacement characters (0 is replaced by CR, so total characters=2)

30 is the hex value for 0

0D is the hex value for a CR (the character that will replace the 0)

F1 is the “Send all characters” command

0D is the hex value for a CR

The data is output as: 1234


5678
ABC
<CR>

** Exit Setup 204


Enter Setup

BA Replace a string with another

Syntax=BAnnNN1SS1NN2SS2

nn: The count of replacements to be made, if nn=00 or nn>=the number of occurrences of a string to be replaced, then
replace all occurrences of that string.

NN1: The length of the string to be replaced, NN1>0.

SS1: The ASCII hex value of each character in the string to be replaced.

NN2: The length of replacement string, NN2>=0. To replace string “SS1” with NUL (i.e. deIete string “SS1”), you should set
NN2 to 00 and leave out SS2.

SS2: The ASCII hex value of each character in the replacement string.

From the current cursor position, search forward for the occurrence of “SS1” string (of length “NN1”) and replace the string
with “SS2” string (of length “NN2”) in the output message until every “SS1” stringis replaced or the count of replacements
made reaches “nn” times, without moving the cursor.

BA Example: Replace “23”s with “ABC”s in barcode data

If the barcode has a string of characters that the host application does not want included, you can use the BA command to
replace the string with something else. In this example, you will replace the “23”s in the barcode above with “ABC”s.

Command string: BA0002323303414243F100

BA is the “Replace a string with another” command

00 is the count of replacements to be made, 00 means to replace all occurrences of that string

02 is the length of the string to be replaced

205 ** Exit Setup


Enter Setup

32 is the hex value for 2 (character in the string to be replaced)

33 is the hex value for 3 (character in the string to be replaced)

03 is the length of the replacement string

41 is the hex value for A (character in the replacement string)

42 is the hex value for B (character in the replacement string)

43 is the hex value for C (character in the replacement string)

F1 is the “Send all characters” command

00 is the hex value for a NUL

The data is output as: cd1ABCabcABCbc12abABC2

BA Example: Remove only the first occurrence of “23”s in barcode data

If the barcode has a string of characters that the host application wants removed, you can use the BA command to replace
the string with NUL. In this example, you will remove the first occurrence of “23” in the barcode above.

Command string: BA0102323300F100

BA is the “Replace a string with another” command

01 is the count of replacements to be made

02 is the length of the string to be replaced

32 is the hex value for 2 (character in the string to be replaced)

33 is the hex value for 3 (character in the string to be replaced)

00 is the length of the replacement string, 00 means to replace the string to be replaced with NUL

F1 is the “Send all characters” command

00 is the hex value for a NUL

The data is output as: cd1abc23bc12ab232

** Exit Setup 206


Enter Setup

EF Insert a delay

Syntax=EFnnnn (nnnn: The delay in 5ms increments, up to 9999)


Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position.
This command can only be used with USB HID Keyboard.

EF Example: Insert a delay of 1s between the 5th and 6th character

Send the first 5 characters in a barcode, wait for 1s, then send the rest of the barcode data.

Command string: F20500EF0200E900


F2 is the “Send a number of characters” command

05 is the number of characters to send

00 is the hex value for a Null character

EF is the “Insert a delay” command

0200 is the delay value (5msX200=1000ms=1s)

E9 is the “Send all but the last characters” command

00 is the number of characters that will not be sent at the end of the message

207 ** Exit Setup


Enter Setup

B5 Insert key strokes

Syntax=B5nnssxx (nn: The number of keys pressed (without key modifiers); ss: the key modifier from the table below; xx:
the key number from the “Unicode Key Maps” in Appendix.)

Insert a key stroke or combination of key strokes. Key strokes are dependent on your keyboard (see the “Unicode Key Maps”
in Appendix). This command can only be used with USB HID Keyboard.

Key Modifiers
No Key Modifier 00
Shift Left 01
Shift Right 02
Alt Left 04
Alt Right 08
Control Left 10
Control Right 20

For example, B501001F inserts an “a” on a U.S. style keyboard. B5 = the command, 01 = number of keys pressed (without
the key modifier), 00 is No Key Modifier, and 1F is the “a” key. If an “A” were to be inserted, B501011F or B501021F would
be entered.

If there are two keystrokes, the syntax would change from Syntax=B5nnssxx for one keystroke to Syntax=B5nnssxxssxx.
An example that would insert “aA” is as follows: B502001F011F.

Note: Key modifiers can be added together when needed. Example: Shift Left + Alt Left + Control Left =15.

** Exit Setup 208


Enter Setup

Chapter 7 Prefix & Suffix

Introduction
A 1D barcode could contain digits, letters, symbols, etc. A 2D barcode could contain more data, such as Chinese characters
and other multi-byte characters. However, in real applications, they do not and should not have all information we need,
such as barcode type, data acquisition time and delimiter, in order to keep the barcodes short and flexible.

Preffix and suffix are how to fulfill the needs mentioned above. They can be added, removed and modified while the original
barcode data remains intact.

Barcode processing procedure:

1. Edit data with Data Formatter

2. Append prefix/suffix

3. Pack data

4. Append terminating character

209 ** Exit Setup


Enter Setup

Global Settings
Enable/Disable All Prefixes/Suffixes

Disable All Prefixes/Suffixes: Transmit barcode data with no prefix/suffix.

Enable All Prefixes/Suffixes: Allow to append Code ID prefix, AIM ID prefix, custom prefix/suffix and terminating character
to the barcode data before the transmission.

** Disable All Prefixes/Suffixes

Enable All Prefixes/Suffixes

Prefix Sequence

** Code ID+ Custom +AIM ID

Custom + Code ID + AIM ID

** Exit Setup 210


Enter Setup

Custom Prefix
Enable/Disable Custom Prefix

If custom prefix is enabled, you are allowed to append to the data a user-defined prefix that cannot exceed 10 characters.
For example, if the custom prefix is “AB” and the barcode data is “123”, the Host will receive “AB123”.

** Disable Custom Prefix

Enable Custom Prefix

Set Custom Prefix

To set a custom prefix, scan the Set Custom Prefix barcode then the numeric barcodes corresponding to the hexadecimal
value of a desired prefix then the Save barcode.

Note: A custom prefix cannot exceed 10 characters.

Set Custom Prefix

Set the custom prefix to “CODE” (HEX: 0x43/0x4F/0x44/0x45):

1. Scan the Enter Setup barcode.

2. Scan the Set Custom Prefix barcode.

3. Scan the numeric barcodes “4”, “3”, “4”, “F”, “4”, “4”, “4” and “5” from the “Digit Barcodes” section in
Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Enable Custom Prefix barcode.

6. Scan the Exit Setup barcode.

211 ** Exit Setup


Enter Setup

AIM ID Prefix
AIM (Automatic Identification Manufacturers) ID defines symbology identifier (For the details, see the “AIM ID Table”
section in Appendix). If AIM ID prefix is enabled, the scanner will add the symbology identifier before the scanned data
after decoding.

** Disable AIM ID Prefix

Enable AIM ID Prefix

AIM ID is not user programmable.

** Exit Setup 212


Enter Setup

Code ID Prefix
Code ID can also be used to identify barcode type. Unlike AIM ID, Code ID is user programmable. Code ID can only consist
of one or two English letters.

** Disable Code ID Prefix

Enable Code ID Prefix

Restore All Default Code IDs

For the information of default Code IDs, see the “Code ID Table” section in Appendix.

Restore All Default Code IDs

Modify Code ID

See the examples below to learn how to modify a Code ID and restore the default Code IDs of all symbologies.

213 ** Exit Setup


Enter Setup

Modify PDF417 Code ID to be “p” (HEX: 0x70):

1. Scan the Enter Setup barcode.

2. Scan the Modify PDF417 Code ID barcode.

3. Scan the numeric barcodes “7” and “0” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Exit Setup barcode.

Restore the default Code IDs of all symbologies:

1. Scan the Enter Setup barcode.

2. Scan the Restore All Default Code IDs barcode.

3. Scan the Exit Setup barcode.

** Exit Setup 214


Enter Setup

1D symbologies:

Modify Code 128 Code ID

Modify GS1-128 Code ID

Modify EAN-8 Code ID

Modify EAN-13 Code ID

Modify UPC-E Code ID

Modify UPC-A Code ID

Modify Interleaved 2 of 5 Code ID

215 ** Exit Setup


Enter Setup

Modify ITF-14 Code ID

Modify ITF-6 Code ID

Modify Matrix 2 of 5 Code ID

Modify Code 39 Code ID

Modify Codabar Code ID

Modify Code 93 Code ID

Modify China Post 25 Code ID

Modify AIM 128 Code ID

** Exit Setup 216


Enter Setup

Modify ISBT 128 Code ID

Modify ISSN Code ID

Modify ISBN Code ID

Modify Industrial 25 Code ID

Modify Standard 25 Code ID

Modify Plessey Code ID

Modify Code 11 Code ID

Modify MSI-Plessy Code ID

217 ** Exit Setup


Enter Setup

Modify GS1 Composite Code ID

Modify GS1 Databar Code ID

Modify Code 49 Code ID

Modify Code 16K Code ID

** Exit Setup 218


Enter Setup

2D symbologies:

Modify PDF417 Code ID

Modify QR Code ID

Modify Aztec Code ID

Modify Data Matrix Code ID

Modify Maxicode Code ID

Modify Chinese Sensible Code ID

Modify GM Code ID

219 ** Exit Setup


Enter Setup

Modify Micro PDF417 Code ID

Modify Micro QR Code ID

Modify Code One Code ID

** Exit Setup 220


Enter Setup

Postal symbologies:

Modify USPS Postnet Code ID

Modify USPS Inteligent Mail Code ID

Modify Royal Mail Code ID

Modify USPS Planet Code ID

Modify KIX Post Code ID

Modify Australian Postal Code ID

221 ** Exit Setup


Enter Setup

Custom Suffix
Enable/Disable Custom Suffix

If custom suffix is enabled, you are allowed to append to the data a user-defined suffix that cannot exceed 10 characters.
For example, if the custom suffix is “AB” and the barcode data is “123”, the Host will receive “123AB”.

** Disable Custom Suffix

Enable Custom Suffix

Set Custom Suffix

To set a custom suffix, scan the Set Custom Suffix barcode then the numeric barcodes corresponding to the hexadecimal
value of a desired suffix then the Save barcode.

Note: A custom suffix cannot exceed 10 characters.

Set Custom Suffix

Set the custom suffix to “CODE” (HEX: 0x43/0x4F/0x44/0x45):


1. Scan the Enter Setup barcode.
2. Scan the Set Custom Suffix barcode.
3. Scan the numeric barcodes “4”, “3”, “4”, “F”, “4”, “4”, “4” and “5” from the “Digit Barcodes” section in
Appendix.
4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the Enable Custom Suffix barcode.
6. Scan the Exit Setup barcode.

** Exit Setup 222


Enter Setup

Data Packing
Introduction

Data packing is designed for a specific group of users who want to have the data packed before transmission. Data packing
influences data format, so it is advised to disable this feature when it is not required.

Data Packing Options

 Disable Data Packing: Transmit decoded data in raw format (unpacketed).

 Enable Data Packing, Format 1: Transmit decoded data with the packet format 1 defined below.

Packet format 1: [STX + ATTR + LEN] + [AL_TYPE + DATA] + [LRC]

STX: 0x02

ATTR: 0x00

LEN: Barcode data length is expressed in 2 bytes ranging from 0x0000 (0) to 0xFFFF (65535).

AL_TYPE: 0x36

DATA: Raw barcode data.

LRC: Check digit.


LRC calculation algorithm: computation sequence: 0xFF+LEN+AL_TYPE+DATA; computation method is XOR, byte
by byte.

 Enable Data Packing, Format 2: Transmit decoded data with the packet format 2 defined below.

Packet format 2: [STX + ATTR + LEN] + [AL_TYPE] + [Symbology_ID + DATA] + [LRC]

STX: 0x02

ATTR: 0x00

LEN: Barcode data length is expressed in 2 bytes ranging from 0x0000 (0) to 0xFFFF (65535).

AL_TYPE: 0x3B

Symbology_ID: The ID number of symbology, 1 byte.

DATA: Raw barcode data.

LRC: Check digit.


LRC calculation algorithm: computation sequence: 0xFF+LEN+AL_TYPE+Symbology_ID+DATA; computation
method is XOR, byte by byte.

223 ** Exit Setup


Enter Setup

** Disable Data Packing

Enable Data Packing, Format 1

Enable Data Packing, Format 2

** Exit Setup 224


Enter Setup

Terminating Character Suffix


Enable/Disable Terminating Character Suffix

A terminating character such as carriage return (CR) or carriage return/line feed pair (CRLF) can only be used to mark the
end of data, which means nothing can be added after it.

Disable Terminating Character Suffix

** Enable Terminating Character Suffix

Set Terminating Character Suffix

To set a terminating character suffix, scan the Set Terminating Character Suffix barcode then the numeric barcodes
corresponding to the hexadecimal value of a desired terminating character then the Save barcode.

Note: A terminating character suffix cannot exceed 2 characters.

Set Terminating Character Suffix

Set Terminating Character to CR (0x0D)

** Set Terminating Character to CRLF (0x0D,0x0A)

225 ** Exit Setup


Enter Setup

Set the terminating character suffix to 0x0A:

1. Scan the Enter Setup barcode.

2. Scan the Set Terminating Character Suffix barcode.

3. Scan the numeric barcodes “0” and “A” from the “Digit Barcodes” section in Appendix.

4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.

5. Scan the Enable Terminating Character Suffix barcode.

6. Scan the Exit Setup barcode.

** Exit Setup 226


Enter Setup

Chapter 8 Batch Programming

Introduction

Batch programming enables users to integrate a batch of commands into a single batch barcode.

Listed below are batch programming rules:

1. Command format: Command + Parameter Value.

2. Each command is terminated by a semicolon (;). Note that there is no space between a command and its terminator
semicolon.

3. Use the barcode generator software to generate a 2D batch barcode.

Example: Create a batch barcode for Illumination Always On, Sense Mode, Decode Session Timeout = 2s:

1. Input the commands:

@ILLSCN2;SCNMOD2;ORTSET2000;

2. Generate a batch barcode.

When setting up a scanner with the above configuration, scan the Enable Batch Barcode barcode and then the batch
barcode generated.

Enable Batch Barcode

227 ** Exit Setup


Enter Setup

Create a Batch Command


A batch command may contain a number of individual commands each of which is terminated by a semicolon (;).

For more information, refer to the Serial Programming Command Manual.

Create a Batch Barcode


Batch barcodes can be produced in the format of PDF417, QR Code or Data Matrix.

Example: Create a batch barcode for lllumination Always On, Sense Mode, Decode Session Timeout = 2s:

1. Input the following commands:

@ILLSCN2;SCNMOD2;ORTSET2000;

2. Generate a PDF417 batch barcode.

** Exit Setup 228


Enter Setup

Use Batch Barcode


To put a batch barcode into use, scan the following barcodes. (Use the example above.)

Enter Setup

Enable Batch Barcode

Batch Barcode

Exit Setup

229 ** Exit Setup


Appendix

Digit Barcodes

0~9

5
6

9
A~F

F
Save/Cancel Barcodes
After reading numeric barcode(s), you need to scan the Save barcode to save the data. If you scan the wrong digit(s), you
can either scan the Cancel barcode and then start the configuration all over again, or scan the Delete the Last Digit
barcode and then the correct digit, or scan the Delete All Digits barcode and then the digits you want.

For instance, after reading the Maximum Length barcode and numeric barcodes “1”, “2” and “3”, you scan:

 Delete the Last Digit: The last digit “3” will be removed.

 Delete All Digits: All digits “123” will be removed.

 Cancel: The maximum length configuration will be cancelled. And the scanner is still in the setup mode.

Save

Cancel

Delete the Last Digit

Delete All Digits


Factory Defaults Table
Parameter Factory Default Remark
System Settings
Barcode Programming Disabled (Exit Setup)
Programming Barcode Data Do not transmit
Illumination Normal
Aiming Normal
Good Read LED On
Good Read LED Duration Short (20ms)
Power On Beep On
Good Read Beep On
Good Read Beep Duration Medium (80ms)
Good Read Beep Frequency Medium (2730Hz)
Good Read Beep Volume Loud
Scan Mode Sense Mode
Decode Session Timeout 3,000ms. 1-3,600,000ms; 0: Infinite
Image Stabilization Timeout (Sense Mode) 200ms 0-3,000ms
Timeout between Decodes (Same Disabled
Barcode) 1,500ms 0-3,600,000ms
Sensitivity Medium Sensitivity
Trigger Commands Disabled
Scanning Preference Normal Mode
Decode Area Whole Area Decoding
Specify Decoding Area 40% top, 60% bottom, 40% left, 60% right
Image Flipping Do Not Flip
Off
Bad Read Message
NG 1-7 characters
RS-232 Interface
Baud Rate 9600
Parity Check None
Data Bits 8
Stop Bits 1
Hardware Auto Flow Control Disabled
USB Interface
Default USB CDC
USB Country Keyboard US keyboard USB HID Keyboard
Beep on Unknown Character Off USB HID Keyboard
Emulate ALT+Keypad Off USB HID Keyboard
Code Page Code Page 1252 (Latin, Western European) USB HID Keyboard
Unicode Encoding Off USB HID Keyboard
Function Key Mapping Off USB HID Keyboard
Inter-Keystroke Delay No Delay USB HID Keyboard
Caps Lock Off USB HID Keyboard
Convert Case No Case Conversion USB HID Keyboard
Emulate Numeric Keypad 1 Off USB HID Keyboard
Emulate Numeric Keypad 2 Off USB HID Keyboard
Fast Mode Off USB HID Keyboard
Polling Rate 4ms USB HID Keyboard
Symbologies
Global Settings
1D Twin Code Single 1D Code Only
Code 128
Code 128 Enabled
Maximum Length 48
Minimum Length 1
EAN-8
EAN-8 Enabled
Check Character Transmit
2-Digit Add-On Code Disabled
5-Digit Add-On Code Disabled
Convert EAN-8 to EAN-13 Disabled
EAN-13
EAN-13 Enabled
Check Character Transmit
2-Digit Add-On Code Disabled
5-Digit Add-On Code Disabled
UPC-E
UPC-E Enabled
Check Character Transmit
2-Digit Add-On Code Disabled
5-Digit Add-On Code Disabled
Transmit Preamble Character System Character
Convert UPC-E to UPC-A Disabled
UPC-A
UPC-A Enabled
Check Character Transmit
2-Digit Add-On Code Disabled
5-Digit Add-On Code Disabled
Transmit Preamble Character No Preamble
Coupon
UPC-A/EAN-13 with Extended Coupon Off
Code
Coupon GS1 DataBar Output Off
Interleaved 2 of 5
Interleaved 2 of 5 Enabled
Maximum Length 80
Minimum Length 6 No less than 4
Check Character Verification Disabled
ITF-14
ITF-14 Disabled
ITF-6
ITF-6 Disabled
Matrix 2 of 5
Matrix 2 of 5 Enabled
Maximum Length 80
Minimum Length 4 No less than 4
Check Character Verification Disabled
Code 39
Code 39 Enabled
Maximum Length 48
Minimum Length 1
Check Character Verification Disabled
Start/Stop Character Do not transmit
Code 39 Full ASCII Disabled
Code 32 Pharmaceutical (PARAF) Disabled
Code 32 Prefix Disabled
Code 32 Start/Stop Character Do not transmit
Code 32 Check Character Do not transmit
Codabar
Codabar Enabled
Maximum Length 60
Minimum Length 2
Check Character Verification Disabled
Do not transmit
Start/Stop Character
ABCD/ABCD
Code 93
Code 93 Disabled
Maximum Length 48
Minimum Length 1
Check Character Verification Do Not Transmit Check Character After Verification
China Post 25
China Post 25 Disabled
Maximum Length 48
Minimum Length 1
Check Character Verification Disabled
GS1-128 (UCC/EAN-128)
GS1-128 Enabled
Maximum Length 48
Minimum Length 1
GS1 Databar
GS1 Databar Enabled
Application Identifier “01” Transmit
EAN•UCC Composite
GS1 Composite Disabled
UPC/EAN Composite Disabled
Code 11
Code 11 Disabled
Maximum Length 48
Minimum Length 4 No less than 4
Check Character Verification One Check Character, MOD11
Check Character Transmit
ISBN
ISBN Disabled
Set ISBN Format ISBN-10
ISSN
ISSN Disabled
Industrial 25
Industrial 25 Disabled
Maximum Length 48
Minimum Length 6 No less than 4
Check Character Verification Disabled
Standard 25
Standard 25 Disabled
Maximum Length 48
Minimum Length 6 No less than 4
Check Character Verification Disabled
Plessey
Plessey Disabled
Maximum Length 48
Minimum Length 4 No less than 4
Check Character Verification Disabled
MSI-Plessey
MSI-Plessey Disabled
Maximum Length 48
Minimum Length 4 No less than 4
Check Character Verification One Check Character, MOD10
Check Character Transmit
AIM 128
AIM 128 Disabled
Maximum Length 48
Minimum Length 1
ISBT 128
ISBT 128 Disabled
Code 49
Code 49 Disabled
Maximum Length 80
Minimum Length 1
Code 16K
Code 16K Disabled
Maximum Length 80
Minimum Length 1
PDF417
PDF417 Enabled
Maximum Length 2710
Minimum Length 1
PDF417 Twin Code Single PDF417 Only
PDF417 Inverse Decode Regular PDF417 Barcodes Only
Character Encoding Default Character Encoding
PDF417 ECI Output Enabled
Micro PDF417
Micro PDF417 Disabled
Maximum Length 366
Minimum Length 1
QR Code
QR Code Enabled
Maximum Length 7089
Minimum Length 1
QR Twin Code Single QR Only
QR Inverse Decode Regular QR Barcodes Only
Character Encoding Default Character Encoding
QR ECI Output Enabled
Micro QR Code
Micro QR Enabled
Maximum Length 35
Minimum Length 1
Aztec
Aztec Code Disabled
Maximum Length 3832
Minimum Length 1
Read Multi-barcodes on an Image Mode 1
Character Encoding Default Character Encoding
Aztec ECI Output Enabled
Data Matrix
Data Matrix Enabled
Maximum Length 3116
Minimum Length 1
Data Matrix Twin Code Single Data Matrix Only
Rectangular Barcode Enabled
Data Matrix Inverse Decode Regular Data Matrix Barcodes Only
Character Encoding Default Character Encoding
Data Matrix ECI Output Enabled
Maxicode
Maxicode Disabled
Maximum Length 150
Minimum Length 1
Chinese Sensible Code
Chinese Sensible Code Disabled
Maximum Length 7827
Minimum Length 1
Chinese Sensible Twin Code Single Chinese Sensible Code Only
Chinese Sensible Code Inverse Decode Regular Chinese Sensible Barcodes Only
GM Code
GM Disabled
Maximum Length 2571
Minimum Length 1
Code One
Code One Disabled
Maximum Length 3550
Minimum Length 1
USPS Postnet
USPS Postnet Disabled
Check Character Transmit
USPS Intelligent Mail
USPS Intelligent Mail Disabled
Royal Mail
Royal Mail Disabled
USPS Planet
USPS Planet Disabled
Check Character Transmit
KIX Post
KIX Post Disabled
Australian Postal
Australian Postal Disabled
Specific OCR-B
Specific OCR-B Disabled
Passport OCR
Passport OCR Disabled
Data Formatter
Data Formatter Disabled
Non-Match Error Beep On
Multiple Data Formats Off
Data Format Selection Format_0
Prefix & Suffix
All Prefixes/Suffixes Disabled
Prefix Sequence Code ID+ Custom +AIM ID
Custom Prefix Disabled
AIM ID Prefix Disabled
Code ID Prefix Disabled
Custom Suffix Disabled
Data Packing Disable Data Packing
Terminating Character Suffix Enabled
CRLF (0x0D, 0x0A)
AIM ID Table
Symbology AIM ID Possible AIM ID Modifiers (m)
Code128 ]C0
GS1-128 (UCC/EAN-128) ]C1
EAN-8 ]E4
EAN-8 with Addon ]E3
EAN-13 ]E0
EAN-13 with Addon ]E3
UPC-E ]E0
UPC-E with Addon ]E3
UPC-A ]E0
UPC-A with Addon ]E3
Interleaved 2 of 5 ]Im 0, 1, 3
ITF-14 ]Im 1, 3
ITF-6 ]Im 1, 3
Matrix 2 of 5 ]X0
Code 39 ]Am 0, 1, 3, 4, 5, 7
Codabar ]Fm 0, 2, 4
Code 93 ]G0
China Post 25 ]X0
AIM 128 ]C2
ISBT 128 ]C4
ISSN ]X0
ISBN ]X0
Industrial 25 ]S0
Standard 25 ]R0
Plessey ]P0
Code 11 ]Hm 0, 1, 3
MSI Plessey ]Mm 0, 1
GS1 Composite ]em 0-3
GS1 Databar (RSS) ]e0
Code 49 ]T0
Code 16K ]K0
Symbology AIM ID Possible AIM ID Modifiers (m)
PDF417 ]Lm 0-2
QR Code ]Qm 0-6
Aztec ]zm 0-9, A-C
Data Matrix ]dm 0-6
Maxicode ]Um 0-3
Chinese Sensible Code ]X0
GM ]gm (0~9)
Micro PDF417 ]L0
Micro QR ]Q1
Code One ]X0
USPS Postnet ]X0
USPS Inteligent Mail ]X0
Royal Mail ]X0
USPS Planet ]X0
KIX Post ]X0
Australian Postal ]X0
Specific OCR-B ]o2
Passport OCR ]o2

Note: “m” represents the AIM modifier character. Refer to ISO/IEC 15424:2008 Information technology – Automatic identification
and data capture techniques – Data Carrier Identifiers (including Symbology Identifiers) for AIM modifier character details.
Code ID Table
Symbology Code ID
Code128 j
GS1-128 (UCC/EAN-128) j
EAN-8 d
EAN-13 d
UPC-E c
UPC-A c
Interleaved 2 of 5 e
ITF-14 e
ITF-6 e
Matrix 2 of 5 v
Code 39 b
Codabar a
Code 93 i
China Post 25 X
AIM 128 X
ISBT 128 X
ISSN g
ISBN B
Industrial 25 I
Standard 25 f
Plessey n
Code 11 H
MSI Plessey m
GS1 Composite y
GS1 Databar (RSS) R
Code 49 X
Code 16K X
PDF417 r
QR Code s
Aztec z
Data Matrix u
Symbology Code ID
MaxiCode x
Chinese Sensible Code h
GM Code x
Micro PDF417 R
Micro QR X
Code One X
USPS Postnet P
USPS Inteligent Mail M
Royal Mail x
USPS Planet L
KIX Post K
Australian Postal A
Specific OCR-B S
Passport OCR O
Symbology ID Number
Symbology ID Number
Code 128 002
GS1-128 (UCC/EAN-128) 003
EAN-8 004
EAN-13 005
UPC-E 006
UPC-A 007
Interleaved 2 of 5 008
ITF-14 009
ITF-6 010
Matrix 2 of 5 011
Code 39 013
Codabar 015
Code 93 017
China Post 25 019
AIM 128 020
ISBT 128 021
ISSN 023
ISBN 024
Industrial25 025
Standard25 026
Plessey 027
Code11 028
MSI-Plessey 029
GS1 Composite 030
GS1 Databar (RSS) 031
PDF417 032
QR Code 033
Aztec 034
Data Matrix 035
Maxicode 036
Chinese Sensible Code 039
Symbology ID Number
GM Code 040
Micro PDF417 042
Micro QR 043
Code One 048
Specific OCR-B 064
Passport OCR 066
USPS Postnet 096
USPS Inteligent Mail 097
Royal Mail 098
USPS Planet 099
KIX Post 100
Australian Postal 101
ASCII Table
Hex Dec Char
00 0 NUL (Null char.)
01 1 SOH (Start of Header)
02 2 STX (Start of Text)
03 3 ETX (End of Text)
04 4 EOT (End of Transmission)
05 5 ENQ (Enquiry)
06 6 ACK (Acknowledgment)
07 7 BEL (Bell)
08 8 BS (Backspace)
09 9 HT (Horizontal Tab)
0a 10 LF (Line Feed)
0b 11 VT (Vertical Tab)
0c 12 FF (Form Feed)
0d 13 CR (Carriage Return)
0e 14 SO (Shift Out)
0f 15 SI (Shift In)
10 16 DLE (Data Link Escape)
11 17 DC1 (XON) (Device Control 1)
12 18 DC2 (Device Control 2)
13 19 DC3 (XOFF) (Device Control 3)
14 20 DC4 (Device Control 4)
15 21 NAK (Negative Acknowledgment)
16 22 SYN (Synchronous Idle)
17 23 ETB (End of Trans. Block)
18 24 CAN (Cancel)
19 25 EM (End of Medium)
1a 26 SUB (Substitute)
1b 27 ESC (Escape)
1c 28 FS (File Separator)
1d 29 GS (Group Separator)
Hex Dec Char
1e 30 RS (Request to Send)
1f 31 US (Unit Separator)
20 32 SP (Space)
21 33 ! (Exclamation Mark)
22 34 " (Double Quote)
23 35 # (Number Sign)
24 36 $ (Dollar Sign)
25 37 % (Percent)
26 38 & (Ampersand)
27 39 ` (Single Quote)
28 40 ( (Left/ Opening Parenthesis)
29 41 ) (Right/ Closing Parenthesis)
2a 42 * (Asterisk)
2b 43 + (Plus)
2c 44 , (Comma)
2d 45 - (Minus/ Dash)
2e 46 . (Dot)
2f 47 / (Forward Slash)
30 48 0
31 49 1
32 50 2
33 51 3
34 52 4
35 53 5
36 54 6
37 55 7
38 56 8
39 57 9
3a 58 : (Colon)
3b 59 ; (Semi-colon)
3c 60 < (Less Than)
3d 61 = (Equal Sign)
Hex Dec Char
3e 62 > (Greater Than)
3f 63 ? (Question Mark)
40 64 @ (AT Symbol)
41 65 A
42 66 B
43 67 C
44 68 D
45 69 E
46 70 F
47 71 G
48 72 H
49 73 I
4a 74 J
4b 75 K
4c 76 L
4d 77 M
4e 78 N
4f 79 O
50 80 P
51 81 Q
52 82 R
53 83 S
54 84 T
55 85 U
56 86 V
57 87 W
58 88 X
59 89 Y
5a 90 Z
5b 91 [ (Left/ Opening Bracket)
5c 92 \ (Back Slash)
5d 93 ] (Right/ Closing Bracket)
Hex Dec Char
5e 94 ^ (Caret/ Circumflex)
5f 95 _ (Underscore)
60 96 ' (Grave Accent)
61 97 a
62 98 b
63 99 c
64 100 d
65 101 e
66 102 f
67 103 g
68 104 h
69 105 i
6a 106 j
6b 107 k
6c 108 l
6d 109 m
6e 110 n
6f 111 o
70 112 p
71 113 q
72 114 r
73 115 s
74 116 t
75 117 u
76 118 v
77 119 w
78 120 x
79 121 y
7a 122 z
7b 123 { (Left/ Opening Brace)
7c 124 | (Vertical Bar)
7d 125 } (Right/ Closing Brace)
7e 126 ~ (Tilde)
7f 127 DEL (Delete)
Unicode Key Maps