0% found this document useful (0 votes)
3 views27 pages

D-Agent - 1 - work-460-S-Upload-3300 XL 11 MM Proximity Transducer System Datasheet - 146256

The 3300 XL 11 mm Proximity Transducer System includes a probe, extension cable, and Proximitor Sensor, designed for non-contacting vibration and displacement measurements in fluid film bearing machines. It features a longer linear range than the standard 8 mm system and is suitable for various applications such as axial position measurements and tachometer signals. The system requires all components to be replaced when upgrading from the 7200-series and may need software updates for compatibility with existing monitoring systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views27 pages

D-Agent - 1 - work-460-S-Upload-3300 XL 11 MM Proximity Transducer System Datasheet - 146256

The 3300 XL 11 mm Proximity Transducer System includes a probe, extension cable, and Proximitor Sensor, designed for non-contacting vibration and displacement measurements in fluid film bearing machines. It features a longer linear range than the standard 8 mm system and is suitable for various applications such as axial position measurements and tachometer signals. The system requires all components to be replaced when upgrading from the 7200-series and may need software updates for compatibility with existing monitoring systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

3300 XL 11 mm Proximity Transducer

System
Datasheet
Bently Nevada Machinery Condition Monitoring 146256 Rev. P

Description
Transducer System
The 3300 XL 11 mm Proximity Transducer System consists of:
l 3300 XL 11 mm probe
l 3300 XL 11 mm extension cable
l 3300 XL 11 mm Proximitor Sensor1

The 3300 XL 11 mm Proximity Transducer System has a 3.94


V/mm (100 mV/mil) output for non-contacting vibration and
displacement measurements on fluid film bearing machines.
The large 11 mm tip enables this transducer system to have a
longer linear range compared to our standard 3300 XL 8 mm
Transducer System. It is primarily used in the following
applications where the longer linear range is necessary:
l Axial (thrust) position measurements
l Ramp differential expansion measurements on steam
turbines
l Rod position or rod drop measurements on
reciprocating compressors
l Tachometer and zero speed measurements
l Phase reference (Keyphasor) signals
The 3300 XL 11 mm Proximitor Sensor is designed to replace
the 7200-series 11 mm and 14 mm Transducer Systems. When
upgrading from the 7200-series system to the 3300 XL 11 mm
system, every component must be replaced with 3300 XL 11
mm components. In addition, the monitoring system must be
updated. If using a 3500 Monitoring System, an updated
version of the configuration software that lists the 3300 XL 11
mm Transducer System as a compatible option is required.
Existing 3300 Monitoring Systems may need a modification.
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P
Contact your local sales and service our patented CableLoc design that provides
representative for assistance. 330 N (75 lb) pull strength.
3300 XL Probes and Extension Cables can also
The 3300 XL 11 mm Proximity
be ordered with a FluidLoc cable option. This
Transducer is designed for measuring
option prevents oil and other liquids from
position or vibration within a
leaking out of the machine through the cable’s
frequency range of 0 to 8 kHz. Typical
interior. The connector protector option
applications of this system include
provides additional protection of the
radial vibration and position, axial
connectors in a humid or moist environment.
position and Keyphasor
Connector protectors are recommended for all
measurements.
installations and provide increased
environmental protection2. Additionally, the
Although the terminals and
3300 XL 11 mm probe comes standard with a
connector on the Proximitor sensor
locknut with pre-drilled safety wire holes.
have protection against electrostatic
discharge, take reasonable Notes:
precautions to avoid electrostatic
discharge during handling. 1. Proximitor Sensors are supplied by
default from the factory calibrated to AISI
4140 steel. Calibration to other target
Proximitor Sensor materials is available upon request.
The 3300 XL 11 mm Proximitor Sensor has the 2. Silicone tape is also provided with each
same advanced features found in the 3300 XL 8 3300 XL extension cable and can be used
mm Proximitor Sensor. Its thin design allows it instead of connector protectors. Silicone
to be mounted in either a high-density DIN-rail
tape is not recommended in applications
installation or a more traditional panel mount
configuration. Improved RFI/EMI immunity where the probe-to-extension cable
allows the 3300 XL Proximitor Sensor to achieve connection will be exposed to turbine oil.
European CE mark approvals without any
special mounting considerations. This RFI
immunity also prevents the transducer system
from being adversely affected by nearby high
frequency radio signals. SpringLoc terminal
strips on the Proximitor Sensor require no
special installation tools and facilitate faster,
highly robust field wiring connections.
Proximity Probe and Extension Cable
The 3300 XL 11 mm probe comes in varying
probe case configurations, including armored
and unarmored ½-20, 5⁄8 -18, M14 X 1.5 and M16
X 1.5 probe threads. The reverse mount 3300 XL
11 mm probe comes standard with either 3⁄8-24
or M10 X 1 threads. All components of the
transducer system have gold-plated brass
ClickLoc connectors. ClickLoc connectors lock
into place, preventing the connection from
becoming loose. The patented TipLoc molding
method provides a robust bond between the
probe tip and the probe body. The probe cable
is securely attached to the probe tip utilizing

2/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Extension Cable dc Resistance


Specifications Resistance Resistance
Unless otherwise noted, the following from Center from Coaxial
specifications are for a 3300 XL 11 mm Length of Conductor to Conductor to
Proximitor Sensor, extension cable and probe Extension Center Coaxial
between 0°C and +45°C (+32°F to +113°F) at a Cable (m) Conductor Conductor
maximum altitude of 2000m, with a -24 Vdc (RCORE) (RJACKET)
power supply, a 10 kΩ load, our supplied AISI (ohms) (ohms)
4140 steel target that is 31 mm (1.2 in) diameter 4.0 1.0 ± 0.25 0.3 ± 0.1
or larger, and a probe gap of 2.5 mm (100
mils). The system accuracy and 8.0 2.0 ± 0.5 0.6 ± 0.2
interchangeability specifications do not apply
when using a transducer system calibrated to
any target other than our AISI 4140 steel target. Extension cable 69.9 pF/m (21.3 pF/ft)
capacitance typical
Electrical
0.2 to 1.5 mm2 (16 to 24
AWG) [0.25 to 0.75 mm2 (18
Proximitor Sensor
to 23 AWG) with ferrules].
Accepts one non-contacting Recommend using three-
Input 3300 XL 11 mm Proximity Probe conductor shielded triad
and Extension Cable. cable. Maximum length of
305 meters (1,000 feet)
Field wiring
Requires -17.5 Vdc to -26 Vdc between the 3300 XL
without barriers at 12 mA Proximitor Sensor and the
maximum consumption, -23 monitor. See the frequency
Power Vdc to -26 Vdc with barriers. response graph for signal
Operation at a more positive rolloff at high frequencies
voltage than -23.5 Vdc can when using longer field
result in reduced linear range. wiring lengths.

Less than 2 mV change in 4.0 mm (160 mils). Linear


Supply
output voltage per volt change range begins at
Sensitivity
in input voltage. approximately 0.5 mm (20
mils) from target and is
Output 50 Ω from 0.5 to 4.5 mm (20 to
resistance 180 mils) (approximately –1
to –17 Vdc). Extended
Probe dc Resistance Linear Range
Deviation from Straight
Resistance from the Center Line (DSL) range is from
Probe approximately 0.5 to 5.0
Conductor to the Outer
Length (m) mm (20 to 200 mils) (–1 to
Conductor (RPROBE) (ohms)
–19 Vdc). The extended DSL
1.0 5.9 ± 0.5 range is not applicable
when using zener barriers.
5.0 7.2 ± 0.8
Recommended
9.0 8.5 ± 1.1 2.5 mm (100 mils)
Gap Setting

3/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

3.94 V/mm (100 mV/mil) Cross-talk Limitation:


±10% including
Incremental interchangeability error Target Size - Flat Surface
Scale Factor when measured in
Diameter
(ISF) increments of 0.5 mm (20
mils) over the 4.0 mm (160 Recommended
mil) linear range. 30.5 mm (1.2 in)
Minimum
Deviation from best fit straight line (DSL) Shaft Diameter
Standard DSL Less than ±0.10 mm (±4 Recommended
range mils). 152 mm (6.0 in)
Minimum
Extended DSL Less than ±0.15 mm (±6
range mils). When operating below
recommended limits, there will be
Over a probe temperature cross-talk between the probes. To
range of -35°C to +120°C (- minimize this effect, close the gap as
31°F to +248°F) with the much as possible while still keeping
Proximitor Sensor and the needed linear range.
extension cable between
0°C to +45°C (+32°F to A shaft diameter of 76.2 mm (3.0 in)
+113°F), the ISF remains can keep the cross-talk below 50 mV
within ±25% of 3.94 V/mm by having the minimum separation of
(100 mV/mil), the DSL transducer tips; it needs to be at least
remains within ±0.51 mm 64 mm (2.5 in) for axial position
(±20 mils) and the measurements and 58 mm (2.3 in)
extended range DSL for radial vibration measurements.
remains within ±0.59 mm
System
(±23 mils) Many factors affect the cross-talk
Performance
over extended when operating below the
Over a Proximitor Sensor recommended limit. Consult
temperatures
and extension cable Performance Specification, document
temperature range of - 144979 for additional information.
35°C to +65°C (-31°F to
+149°F) with the probe
between 0°C to +45°C Effects of 60 Hz Magnetic Fields Up to 300
(+32°F to +113°F), the ISF Gauss (5 meter system)
remains within ±25% of
3.94 V/mm (100 mV/mil), Output voltage in mil pp/gauss
the DSL remains within
±0.51 mm (±20 mils) and Proximitor Ext.
Gap Probe
the extended range DSL Sensor Cable
remains within ±0.59 mm
0.5 mm (20
(±23 mils) 0.006 0.001 0.001
mil)
0 to 8 kHz: +0, -3 dB typical,
Frequency 2.5 mm (100
with up to 305 meters 0.033 0.009 0.005
Response mil)
(1000 feet) of field wiring.
4.6 mm (180
0.033 0.027 0.007
mil)

4/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Mechanical Connector-to-connector torque

Probe Tip Recommended


Polyphenylene sulfide (PPS). Finger tight
Material torque

Probe Case Maximum


AISI 304 stainless steel (SST). 0.565 N•m (5 in•lb)
Material torque

75 Ω triaxial, fluoroethylene Minimum Bend


propylene (FEP) insulated Radius (with or
Probe Cable 25.4 mm (1.0 in)
probe cable in the following without SST
Specification armor)
total probe lengths: 1, 5 or 9
meters.
System Weight (typical)
Extension Cable 75 Ω triaxial, fluoroethylene
Probe
Material propylene (FEP) insulated.
70 g (2.5 oz) (minimum length case, 1m lead,
Proximitor
A380 aluminum no armor)
Sensor Material

5 or 9 meters including 170 g (6.0 oz) (minimum length case, 1m lead,


System Length with armor)
extension cable

Extension Cable For longer case lengths add 1.1 g/mm (1.0
Flexible AISI 302 SST with FEP
Armor oz/in).
outer jacket.
(optional)
For 5 m probe length add 180 g (6 oz) for non-
330 N (75 pounds) probe armored probe or 560 g (20 oz) for armored
Tensile Strength case to probe lead. 270 N probe.
(maximum (60 pounds) at probe lead
rated) to extension cable For 9 m probe length add 360 g (12 oz) for
connectors. non-armored probe or 1120 g (40 oz) for
armored probe.
Connector
Gold-plated brass
Material Extension Cable 45 g/m (0.5 oz/ft)
Probe Case Torque Armored
140 g/m (1.5 oz/ft)
Extension Cable
Maximum
Recommended
Rated Proximitor
255 g (9 oz)
Sensor
1/2-20 and 5/8- 45.2 N•m 15.2 N•m
18 probe cases (400 in•lb) (133 in•lb)
Thread Engagement Limits
M14x1.5 and 63.3 N•m 21.1 N•m
M16x1.5 probe
cases (560 in•lb) (187 in•lb) Probe
Maximum Length of Thread
Case
Engagement
Reverse mount 22.6 N•m 7.5 N•m Thread
probes
(200 in•lb) (66 in•lb) 1/2-20 0.750 in

5/8-18 0.938 in

5/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Probe Storage -52°C to +105°C (-62°F to


Maximum Length of Thread
Case Temperature +221°F)
Engagement
Thread
100% condensing, non-
M14x1.5 21 mm submersible when
Relative
connectors are protected.
M16x1.5 24 mm Humidity
Tested to IEC 68-2-3 damp
heat.
Maximum thread engagement
3300 XL probes are designed
lengths are per the industry standard
to seal differential pressure
of 1.5 times the nominal thread
between the probe tip and
diameter. A fit class matching that of
case. The probe sealing
the external probe thread is assumed
material consists of a Viton
for all internal threads. Applications
Probe O-ring. Probes are not
with thread engagement lengths
Pressure pressure tested prior to
exceeding the values in the table
shipment. Contact our
above may exhibit binding during
custom design department if
installation. Contact your Bently
you require a test of the
Nevada representative if you require
pressure seal for your
probe thread engagement lengths
application
exceeding the values above. Bently
Nevada does not replace proximity
probes under warranty due to It is the responsibility of the customer
excessive thread engagement or user to ensure that all liquids and
lengths. gases are contained and safely
controlled should leakage occur from
a proximity probe. In addition,
Environmental Limits solutions with high or low pH values
may erode the tip assembly of the
Probe Temperature Range probe causing media leakage into
surrounding areas. Bently Nevada not
Operating and be held responsible for any damages
-52°C to +177°C (-62°F to
Storage resulting from leaking 3300 XL
+351°F)
Temperature proximity probes. In addition, 3300 XL
proximity probes does not be
Exposing the probe to temperatures replaced under the service plan due
below -34°C (30°F) may cause to probe leakage.
premature failure of the pressure
seal.

Extension Cable Temperature Range

Operating and
-52°C to +177°C (-62°F to
Storage
+351°F)
Temperature

Proximitor Sensor Temperature Range

Operating -52°C to +100°C (-62°F to


Temperature +212°F)

6/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Hazardous Area Approvals


Compliance and Certifications For the detailed listing of country and
FCC product-specific approvals, refer to
the Approvals Quick Reference Guide
This device complies with part 15 of the (108M1756).
FCC Rules. Operation is subject to the
following two conditions: For additional technical
documentation, please log in to
l This device may not cause harmful bntechsupport.com and access the
interference. Bently Nevada Media Library.
l This device must accept any
interference received, including
interference that may cause cNRTLus
undesired operation.
3300 XL Proximitor Sensor
EMC
European Community Directive: ia Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga;
Class I, Groups A, B, C, and D,
When installed Class II, Groups E, F and G,
EMC Directive 2014/30/EU with Class III;
intrinsically
Standards safe zener T5 @ Ta= -55°C to + 40°C.
barriers per T4 @ Ta= -55°C to + 80°C.
EN 61000-6-2; Immunity for drawing 141092
Industrial Environments or when
installed with
EN 61000-6-4; Emissions for galvanic
Industrial Environments isolators.

RoHS nA, ec Class I, Zone 2: AEx/Ex nA IIC T4/T5 Gc;


Class I, Division 2, Groups A, B, C, and
When installed D;
European Community Directive: with non- Class I, Zone 2: AEx/Ex ec llC T4/T5 Gc;
incendive Class I, Division 2, Groups A, B, C, and
RoHS Directive 2011/65/EU circuit D;
connected per
Maritime drawing T5 @ Ta= -55°C to + 40°C
140979. T4 @ Ta= -55°C to + 80°C
2019 Rules for Conditions of Classification,
Part 1, 1-1-1/7.7, 1-1-A3, 1-1-A4 3300 XL Probe
2019 Rules for Conditions of Classification,
ia Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga;
Part 1, Offshore Units and Structures Class 1, Groups A, B. C, and D,
When installed Class II, Groups E, F, and G,
1-1-4/9.7, 1-1-A2, 1-1-A3 with Class III;
intrinsically
(see Temperature Schedule table to
Functional Safety safe zener
barriers per follow)
drawing 141092
SIL 2, HFT = 0 or when
installed with
SIL 3, HFT = 1 galvanic
isolators.

7/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Class I, Zone 2: AEx/Ex nA IIC T5…T1 Gc; ia


Class 1, Division 2, Groups A, B, C, D;
nA, ec Class 1, Zone 2: AEx/Ex ec llC T5…T1 Gc; II 1 G
Class I, Division 2, Groups A, B, C, and Ex ia IIC T5…T1 Ga,
When installed (see Temperature Schedule
with non- D;
table to follow)
incendive (see Temperature Schedule table to
circuit follow) Ex ia IIIC T90°C ... T280°C Dc
connected per For EPL Dc:
drawing
140979. Ui= -28V Ci = 1.5 nF

ATEX/IECEx Ii = 140 mA Li =610 μH

Pi = 0.91 W
3300 XL Proximitor Sensor
nA,ec
ia II 3 G
Ex nA IIC T5…T1 Gc,
II 1 G Ex ec llC T5…T1 Gc,
Ex ia IIC T4/T5 Ga (see Temperature Schedule
Ex ia IIIC T90C/T105C Dc table to follow)
For EPL Dc:
T105C @ Ta = -55°C to 100°C
T90C @ Ta = -55°C to +85°C Ui= -28V li= 140 mA
Ui= -28V Uo= -28V
Temperature Schedule
Ii= 140mA Io= 140mA

Pi= 0.91W Po= 0.742W Temperature Ambient Temperature


Classification (Probe Only)
Ci- 47nF Co= 1.5nF
For EPL Ga and Gc
Li= 1460µH Lo= 610µH
T1 -55°C to +232°C
nA,ec -55°C to +177°C
T2
II 3 G
Ex nA IIC T4/T5 Gc T3 -55°C to +120°C
Ex ec llC T4/T5 Gc
T4 -55°C to +80°C
Ui= -28V li= 140 mA
T5 -55°C to +40°C
T5 @ Ta= -55˚ C to + 40˚C
T4 @ Ta= -55 ˚C to + 80˚C For EPL Dc

T280°C @ Ta -55°C to +232°C


3300 XL Probe
T225°C @ Ta -55°C to +177°C

Probe entity parameters are met T170°C @ Ta -55C to +120°C


when used with BN extension cables
T130°C @ Ta -55°C to +80°C
and connected to BN Prox.
T105°C @ Ta -55°C to +100°C

T90°C @ Ta -55°C to +40°C

8/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Hazardous Area Conditions of


Safe Use
cNRTLus:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.

ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Proximitor must be installed so as to
provide the terminals with a degree of
protection of at least IP54.

9/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

C: Total Length Option


Ordering Information 10 1.0 meter (3.3 feet)

For the detailed listing of country and 50 5.0 meters (16.4 feet)
product-specific approvals, refer to
the Approvals Quick Reference Guide 9.0 meters (29.5 feet)
(108M1756).
Five meter probes are
For additional technical 90 designed for use with
documentation, please log in to the five meter
bntechsupport.com and access the Proximitor Sensor only.
Bently Nevada Media Library.
D: Connector and Cable-Type Option
3300 XL 11 mm Proximity Probes Miniature coaxial ClickLoc
01 connector with connector
330701 3300 XL 11 mm Probe, 1/2-20 UNF protector, standard cable
thread, without armor
Miniature coaxial ClickLoc
330702 3300 XL 11 mm Probe, 1/2-20 UNF 02
connector, standard cable
thread, with armor
Miniature coaxial ClickLoc
330707 3300 XL 11 mm Probe, 5/8-18 UNF 11 connector with connector
thread, without armor protector, FluidLoc cable
330708 3300 XL 11 mm Probe, 5/8-18 UNF Miniature coaxial ClickLoc
thread, with armor 12
connector, FluidLoc cable
Part Number-AA-BB-CC-DD-EE- E: Agency Approval Option
A:Unthreaded Length Option 00 Not required

Unthreaded length 05 Multiple Approvals


must be at least 1.0
inch less than the case
length.
3300 XL 11 mm Proximity Probes,
Metric
Order in increments of 0.1 in
Length configurations:
330703 3300 XL 11 mm Probe, M14 x 1.5 thread,
Maximum unthreaded length:
without armor
8.9 in
Minimum unthreaded length: 330704 3300 XL 11 mm Probe, M14 x 1.5 thread,
0.0 in with armor
Example: 0 4 = 0.4 in
330709 3300 XL 11 mm Probe, M16 x 1.5 thread,
B: Overall Case Length Option without armor
Order in increments of 0.1 in 330710 3300 XL 11 mm Probe, M16 x 1.5 thread,
Threaded length configurations: with armor
Maximum case length: 9.9 in
Minimum case length: 1.0 in Part Number-AAA-BBB-CC-DD-EE
Example: 2 4 = 2.4 in

10/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

A:Unthreaded Length Option Miniature coaxial ClickLoc


12
connector, FluidLoc cable
Unthreaded length
E: Agency Approval Option
must be at least 26
mm less than the 00 Not required
case length.
05 Multiple Approvals
Order in increments of 2 mm.
Length configuration:
Maximum unthreaded 3300 XL 11 mm Reverse Mount
length: 224 mm
Minimum unthreaded length: Probe
0 mm
Example: 0 6 0 = 60 mm 330705-02-18- CC-DD-EE 3/8-24 UNF
threads
B: Overall Case Length Option
330706-005-046- CC-DD-EE M10 x 1 threads
Order in increments of 2 mm.
Metric thread configurations: C: Total Length Option

Maximum length:250 mm 10 1.0 meter (3.3 feet)

Minimum length:26 mm 50 5.0 meters (16.4 feet)

Example: 0 6 0 = 60 mm 9.0 meters (29.5 feet)

C: Total Length Option Five meter probes are


90 designed for use with
10 1.0 meter (3.3 feet)
the five meter
50 5.0 meters (16.4 feet) Proximitor Sensor only.

9.0 meters (29.5 feet)


D: Connector Option
Five meter probes
Miniature ClickLoc coaxial
are designed for use 02
90 connector
with the five meter
Proximitor Sensor E: Agency Approval Option
only.
00 Not required

D: Connector and Cable-Type Option 05 Multiple Approvals

Miniature coaxial ClickLoc For a shorter delivery time, order commonly


01 connector with connector stocked probes. Currently, stocked probes
protector, standard cable consist of the following part numbers: 330701-
00-10-10-02-00, 330701-00-20-10-02-00,
Miniature coaxial ClickLoc 330703-000-050-10-02-00, 330705-02-18-10-
02
connector, standard cable 02-00, 330706-005-046-10-02-00.
Miniature coaxial ClickLoc
11 connector with connector
protector, FluidLoc cable

11/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

00 Standard cable
3300 XL 11 mm Proximitor Sensor 01 Armored cable

330780-AA-BB Standard cable with connector


02
protector
A: Total Length and Mounting Option
Armored cable with connector
5.0 meter(16.4 feet) system 03
50 protector
length, panel mount
10 FluidLoc cable
5.0 meter (16.4 feet) system
51
length, DIN mount 11 Armored FluidLoc cable

5.0 meter (16.4 feet) system FluidLoc cable with connector


52 12
length, no mounting hardware protector

9.0 meters (29.5 feet) system Armored FluidLoc cable with


90 13
length, panel mount connector protector

9.0 meters (29.5 feet) system C: Agency Approval Option


91
length, DIN mount
00 Not required
9.0 meters (29.5 feet) system
92 05 Multiple Approvals
length, no mounting hardware

B: Agency Approval Option

00 Not required Accessories


05 Multiple approvals
146255 3300XL 11 mm User Guide
Country specific approvals may be 144979 Performance Specification
available, consult your local
Customer Care Representative for Bulk field wire. 1.0 mm2 (18 AWG),
more information. 3 conductor, twisted, shielded
02120015
cable with drain wire. Specify
length in feet.

Bulk field wire. 1.0 mm2 (18 AWG),


3300 XL 11 mm Extension Cable 02173009 3 conductor, twisted, shielded
cable. Specify length in feet.
330730-AAA-BB-CC Replacement panel-mount
138492-01
Make sure that the extension cable length mounting pad
and the probe length, when added together,
Replacement DIN-mount
equal the Proximitor Sensor Total length. 138493-01
mounting pad
A: Cable Length Option
01609137 BNC (F) to banana plugs
040 4.0 meters (13.1 feet)
Proximitor Connector Test Pin
080 8.0 meters (26.2 feet) 01609138 wiring (two test pins to a BNC (F)
connector)
B: Connector and Cable Option

12/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

50 Ω cable with two BNC (M) Female Connector


connectors. Use this cable in Protector. Placed on the probe
combination with adapter lead to connect to the male
40971-04 01609137 and adapter 01609138 connector protector on the
when checking performance of extension cable and provide
the transducer system from the 03839420 environmental protection of
Proximitor Sensor test pin holes. connectors. Also placed on the
extension cable to slide over the
3300XL Proximitor Sensor Panel- Proximitor Sensor connection
mount Screws. Package and protect it from the
includes four 6-32 UNC thread environment.
04310310 forming mounting screws
(Supplied standard with 3300 XL 3300 XL Connector Kit. Used on
Proximitor Housings [3300 XL 3300 XL probes and extension
option]). cables. Contains one set of male
330153-01
and female ClickLoc connectors,
Silicone Self-fusing tape. A 9.1 sleeves and one strip of silicone
meter (10 yard) roll of silicone tape.
tape to protect connectors. It is
easy to install and provides Connector Crimp Tool Kit.
03200006 excellent electrical isolation and Includes one set of 75 Ω 3300 XL
protection from the 163356 ClickLoc inserts and connector
environment. It is not installation instructions.
recommended for use inside the Supplied with carrying case.
casing of the machine.

Connector Protector Kit.


Connector Protector Kit for 3300
40113-02 XL probes and extension cables,
including connector protectors
and installation tools.

Connector Protector Adapter.


Makes our previous 3300
136536-01
connector protector kits
compatible with 3300 XL probes
and extension cable connectors.

Connector Protectors. Package


40180-02 contains 10 pairs of connector
protectors.

Male Connector Protector.


Placed on the extension cable to
connect to the female
03839410 connector protector on the
probe and provide
environmental protection of
connectors.

13/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Graphs and Figures

Figure 1: Typical 3300 XL 11 mm 5 m System Over Ambient Testing Range

14/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 2: Typical 3300 XL 11 mm 9 m System Over Ambient Testing Range

15/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 3: Typical 3300 XL 11 mm Probe + 1 m Cable @ Low Temperature


(Proximitor Sensor + 4m of Extension Cable @ 25 °C)

16/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 4: Typical 3300 XL 11 mm Probe + 1 m Cable @ High Temperature


(Proximitor Sensor + 4m of Extension Cable @ 25 °C)

17/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 5: Typical 3300 XL 11 mm 5 m Proximitor Sensor with 4 m of Extension Cable @ Cold


Temperature
(Probe is at 25°C)

18/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 6: Typical 3300 XL 11 mm 5 m Proximitor Sensor with 4 m Extension Cable @ High


Temperature
(Probe is at 25°C)

19/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 7: Typical 3300 XL 11 mm 9 m Proximitor Sensor with 8 m of Extension Cable @ Low


Temperature
(Probe is at 25°C)

20/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 8: Typical 3300 XL 11 mm 9 m Proximitor with 8 m of Extension Cable @ High Temperature


(Probe is at 25°C.)

21/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 9: Frequency Response, magnitude of typical 3300 XL 11 mm System


with various lengths of field wiring, no barriers

Figure 10: Frequency Response, phase change of typical 3300 XL 11 mm System


with various lengths of field wiring, no barriers

22/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 11: 3300 XL 11 mm Proximity probes, Standard Mount


330701, ½-20 UNF-2A, without armor
330702, ½-20 UNF-2A, with armor
330703, M14X1.5 thread, without armor
330704, M14X1.5 thread, with armor
330707, 5/8-18 UNF-2A, without armor
330708, 5/8-18 UNF-2A, with armor
330709, M16X1.5 thread, without armor
330710, M16X1.5 thread, with armor

Note: Connector Protector only installed on female end when optioned. Both ends available as
accessories.
Figure 12: Installed Connector Protectors

23/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 13: 3300 XL 11 mm Proximity Probes, Reverse Mount


330705, 3/8-24 UNF-2A threads
330706, M10X1 threads

Figure 14: 330730, 3300 XL 11 mm Extension Cable

24/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 15: Panel Mount 3300 XL 11 mm ProximitorSensor

25/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Figure 16: DIN Mount 3300 XL 11 mm Proximitor Sensor


Notes:

1. All dimensions on figures are in millimeters (inches) unless otherwise noted.


2. Standard mount ½-20 UNF thread probes are supplied with ¾ inch lock nut and 7⁄16 wrench
flats.
3. Standard mount M14x1.5 thread probes are supplied with 22 mm lock nut and 12 mm
wrench flats.
4. Standard mount 5⁄8-18 UNF thread probes are supplied with 15⁄16 inch lock nut and 9⁄16
wrench flats.
5. Standard mount M16x1.5 thread probes are supplied with 24 mm lock nut and 14 mm
wrench flats.
6. Reverse mount probes are not available with armor, FluidLoc cable or connector protector
options.
7. Letters inside quotation marks on figures refer to probe ordering options.
8. Stainless steel armor is supplied with FEP outer jacket.
9. FEP jacket is standard on all non-armored probes.
10. Probes ordered with 5 or 9 meter integral cables have a length tolerance of +20%, -0%.

26/27
3300 XL 11 mm Proximity Transducer System
Datasheet 146256 Rev. P

Copyright 2024 Baker Hughes Company. All rights reserved.

Bently Nevada, Keyphasor, M2, Proximitor and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes
business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company.
All other product and company names are trademarks of their respective holders. Use of the trademarks does not
imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not
make any representation as to the accuracy or completeness of the information and makes no warranties of any
kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness
for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.

1631 Bently Parkway South, Minden, Nevada USA 89423


Phone: 1.775.782.3611 (US) or Bently.com/support
Bently.com

27/27

You might also like