20 PRS System

This Field Construction Manual provides safety recommendations and installation instructions for the OTIS GeN2 Comfort position reference system for elevators. It outlines personal protection measures, potential risks, and special precautions during the installation of switches, detectors, and magnets on the car ceiling and floors. The document includes detailed figures and specifications for both normal and low overhead models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views5 pages

20 PRS System

This Field Construction Manual provides safety recommendations and installation instructions for the OTIS GeN2 Comfort position reference system for elevators. It outlines personal protection measures, potential risks, and special precautions during the installation of switches, detectors, and magnets on the car ceiling and floors. The document includes detailed figures and specifications for both normal and low overhead models.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

FIELD CONSTRUCTION MANUAL Ref.

:
Number: A-C49Ev6

SAFETY RECOMMENDATIONS OTIS POSITION REFERENCE SYSTEM


GeN2 Comfort 4-9 persons
DOORS NOT PRIMA TL - CD<1050
Page:
Date:
1/5
JUNE 2009
Supersedes: OCTOBER 2008
PERSONAL PROTECTION

INSTALLATION OF SWITCHES AND DETECTORS ON


CAR CEILING
CONTACTS INSTALLED ON THE GOVERNOR SIDE
Follow the “Instructions for Use” of the personal protection equipment - Install the set of preassembled contacts on the support; check they are in accordance
with the dimensions shown in the drawing and tighten the bolts.
POTENTIAL RISKS
- Falls - Install the support plates for the detectors on the uprights.

- Trappings - Install the detectors on the support plates, adjusting their position.

- Install the detector on the support, adjusting its position. (On low overhead models
SPECIAL PRECAUTIONS
it is installed directly on the car upright without the support. See Figure 2).
- Use the safety harness where necessary
- Extra care when moving around on top of the car

1LV

NOTE: For low overhead models, the installation of the detector 1LV and
the cams in the upper part of the hoistway is different to those
shown in Figure 1. See Figure 2.
DETECTOR
SUPPORT
~505
~444
~383 MAGNET

1LV
12±1
JUNCTION
BOX

JUNCTION
BOX

5LS

UDLS 6LS

FIGURE 1 UDLS
6LS
5LS
FIELD CONSTRUCTION MANUAL Ref.:

OTIS Number: A-C49Ev6


POSITION REFERENCE SYSTEM Page: 2
GeN2 Comfort 4-9 persons Date: JUNE 2009
DOORS NOT PRIMA TL - CD<1050 Supersedes:

ONLY FOR LOW OVERHEAD MODELS (GOVERNOR SIDE)

IMAN

FASTENING 1LV TO
CAR UPRIGHT

FIGURE 2
FIELD CONSTRUCTION MANUAL Ref.:
WIRING DETECTORS AND LIMIT SWITCHES Number: A-C49Ev6

- The set of switches is supplied pre-connected as shown in the drawing. OTIS POSITION REFERENCE SYSTEM
GeN2 Comfort 4-9 persons
DOORS NOT PRIMA TL - CD<1050
Page:
Date:
3
JUNE 2009
Supersedes: OCTOBER 2008

- Run the cables to the junction box for the connectors.

JUNCTION
BOX

CAR

FIGURE 3
FIELD CONSTRUCTION MANUAL Ref.:
TASKS TO BE PERFORMED ON TOP FLOOR Number: A-C49Ev6

- Position the car level with the top floor.


OTIS POSITION REFERENCE SYSTEM
GeN2 Comfort 4-9 persons
DOORS NOT PRIMA TL - CD<1050
Page:
Date:
4
JUNE 2009
Supersedes: OCTOBER 2008

- Mount (2) supports and the cams which activate the switches 2-6LS and UDLS.
Fasten the complete set to the guide rail according to the dimensions shown
in Figures.

NORMAL MODELS COMFORT LOW OVERHEAD COMFORT MODELS

530
0
53 455
5
45
CAM ACTIVATING
UDLS CAM ACTIVATING
2-6LS

FASTENING TO SUPPORT M10

CAM ACTIVATING SUPPORT TO CAR


UDLS GUIDE RAIL
TOP
FLOOR

MAGNET MAGNET
1LV 1LV
1445

FASTENING TO
GUIDE RAIL M10
1685

TOP FLOOR

CAM ACTIVATING
2-6LS
FIGURE 4
FIELD CONSTRUCTION MANUAL Ref.:

OTIS Number: A-C49Ev6


POSITION REFERENCE SYSTEM Page: 5
GeN2 Comfort 4-9 persons Date: JUNE 2009
DOORS NOT PRIMA TL - CD<1050 Supersedes: OCTOBER 2008

INSTALLATION OF MAGNETS ON EACH FLOOR TASKS TO BE PERFORMED ON THE BOTTOM FLOOR


- On each floor, attach the magnets which activate detector 1LV to the guide - Install the support and the cam which activates the switches 1/5 LS
rails at the height shown in the Figure below. and UDLS.
- Install the complete set on the guide rail at the height shown in the
Figure below.

8
39 5
8
16
MAGNET 1LV
CAM ACTIVATING
1-5LS

BOTTOM
= FLOOR

130
=
1LV
MAGNET
1LV

LOW OVERHEAD COMFORT MODELS

CAM ACTIVATING
UDLS

FIGURE 5

INTERMEDIATE BOTTOM FLOOR


FLOORS
0
53
FIGURE 6