HPM
HPM
TRANSPORT EMERGENCY
HPM
VFI
TYPE
ONLINE Modular
3:3
15kVA to 1500kVA UPS
15kVA to 50kVA PM
N+X Redundancy
The HPM is the ultimate modular UPS for DATA CENTERS and other
HIGHLIGHTS
CRITICAL LOADS. The HPM is designed to protect any critical high-
density computer and IT environment, whilst achieving maximum
Utmost Availability availability. The HPM grows along with the demands of the business
without over-sizing the UPS - optimizing both the initial investment
Ultimate Scalability and the Total Cost of Ownership. As soon as demand increases, the
Un-matched Power Density HPM modular solution can expand its power capability, maintaining
2
Efficiency up to 96% the highest levels of power protection, availability, redundancy and
investment savings.
Smart Sleep Function
Multi Control The HPM modular UPS provides the most compact footprint of less
Highly Flexible than 2m with best reliability and high performance, HPM is
considered to be the best power protection solution for large data
Cold Start Feature
centers, as well as for sensitive electronics.
Advanced Power Module Technology
Power Module has been designed based on three level
IGBT Inverter technology with DSP Control. All
components design in one module, less fault points &
integrated inner thermal sensor, for better protection
mechanism gives higher reliability & Power density. The
dedicated and redundant hot-swappable power modules
take the most unique structure design. The PCB boards
and heat sinks are in two completely different layers,
which allow the UPS run in dusty environments,
significantly improving its stability and environmental
adaptability. Cooling air flows in the lower layer, keeping
the upper PCB free of dust. One air flow channel ensures
fans redundancy, even one fan fails, power module can
run normally. Each power modules has its own intelligent
battery charger for long battery life.
Comprehensive temperature monitoring for thermal abnormal detection. UPS can record and save the data
of the main parameters automatically when faults happen for further analysis. It Can record data
information and present as waveform for further analysis can easily spot the causes of the failures, avoid
future similar faults.
Smart Sleep Function
Smart Sleep function can intelligently make some power modules go to sleep when load is relatively low,
improving the efficiency of the remaining power modules and saving customers on power and cooling costs.
Improving efficiency, reducing power and cooling
costs
Self-Loading
Self-aging is an advanced function and it can test UPS
under different load situation without real load, saving
more than 90% of energy. Its Simulate different load
conditions without connecting to any real load, saving 90%
of energy.
On Site setting supported, easy for factory testing.
Battery unit
All these features ensure easy UPS expansion, operation and maintenance;
minimizing downtime, decreasing the Mean Time to Repair (MTTR) and
removing any possible risk to power continuity, when carried out by
authorized service personnel.
Power cabinet system is integrated with Touch screen LCD display with
advanced industry standard communication options available, like
programmable dry contacts, Serial RS 232/USB communication, SNMP &
Modbus communications.
Combo unit
TECHNICAL SPECIFICATION
Specifications: 15 to 90kVA UPS
Current Distortion(THDi)
Voltage Distortion(THDv) <1%for linear load, <3% for non linear load
Corporate office – 318, 3rd floor, Time Tower, MG Road, Gurugram – 122002 Tel:- +91-124-4727134
Factory – Plot No.: 213A, Sector 4, IMT Manesar, Gurugram – 122050 Tel:- +91-124-2975498
Website : www.riello-ups.in | Email : [email protected]
TECHNICAL SPECIFICATION
Specifications: 60 to 200kVA UPS
Voltage Distortion (THDv) <1% for linear load, <3% for non linear load
Corporate office – 318, 3rd floor, Time Tower, MG Road, Gurugram – 122002 Tel:- +91-124-4727134
Factory – Plot No.: 213A, Sector 4, IMT Manesar, Gurugram – 122050 Tel:- +91-124-2975498
Website : www.riello-ups.in | Email : [email protected]
TECHNICAL SPECIFICATION
Specifications: 150 to 200kVA UPS
Current Distortion(THDi)
Voltage Distortion(THDv) <1%for linear load, <3% for non linear load
Corporate office – 318, 3rd floor, Time Tower, MG Road, Gurugram – 122002 Tel:- +91-124-4727134
Factory – Plot No.: 213A, Sector 4, IMT Manesar, Gurugram – 122050 Tel:- +91-124-2975498
Website : www.riello-ups.in | Email : [email protected]
TECHNICAL SPECIFICATION
Specifications: 60 to 300 kVA UPS
Current Distortion(THDi)
Voltage Distortion(THDv) <1%for linear load, <3% for non linear load
Voltage Distortion (THDv) <1%for linear load, <3% for non linear load