0% found this document useful (0 votes)
3 views23 pages

07 PAS Components Overview PACiS HMI Overview

The document provides an overview of the EcoStruxure Power Automation System (EPAS) and its Human-Machine Interface (HMI) components, emphasizing safety information and the roles of HMI clients and servers. It details the features, functionalities, and configurations of the EPAS HMI, including command execution and alarm management. Additionally, it introduces the EcoSUI Suite, which serves as the operating interface for the MCIS solution, highlighting its communication with various modules and system architecture.

Uploaded by

Maianh Tran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views23 pages

07 PAS Components Overview PACiS HMI Overview

The document provides an overview of the EcoStruxure Power Automation System (EPAS) and its Human-Machine Interface (HMI) components, emphasizing safety information and the roles of HMI clients and servers. It details the features, functionalities, and configurations of the EPAS HMI, including command execution and alarm management. Additionally, it introduces the EcoSUI Suite, which serves as the operating interface for the MCIS solution, highlighting its communication with various modules and system architecture.

Uploaded by

Maianh Tran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

EPAS – Components Overview-

HMI OVERVIEW
EcoStruxureTM Power Automation System
Power Solutions Global Training
2021

Confidential Property of Schneider Electric

Internal
Safety Information

▪ It is advisable to read all the Safety


Information, all the time before trying to Install,
Operate, Service or Maintain it.
▪ Electrical equipment should be installed,
operated, serviced and maintained only by
qualified personnel.
▪ Work with facility IT System Administrators to
ensure that the system adheres to the site-
specific cybersecurity policies.
Refer to Official Technical Guides and
documentation related to the version installed.
Failure to follow these instructions can result in
death, serious injury, or equipment damage.

Confidential Property of Schneider Electric | Page 2

Internal
• Content

▪ EPAS HMI Features


▪ EPAS HMI Description
▪ EPAS EcoSUI specifics

Copyright Schneider Electric Page 3


Internal
• EPAS HMI Basic Purpose
➔Basic Purpose : Which EPAS element ?
▪ Display business views
HMI Client
▪ SCP : Substation Control Point
▪ Get data, Archive and logging HMI Server

➔Composition :
▪ HMI Server
▪ IS main SBUS Client (also server of few System Info like Printer
status)
▪ HAS Hard Disk for Archives (Historian SQL server)
▪ HAS Printers (for SOE…)
▪ IS Server of All HMI Client
▪ HMI Client
▪ Subscribe to HMI Server
▪ Display data

Copyright Schneider Electric Page 4


Internal
• Content

▪ EPAS HMI Features


▪ EPAS HMI Description
▪ EPAS EcoSUI specifics

Copyright Schneider Electric Page 5


Internal
• EPAS HMI Windows
1) Title
2) Tools

3) Mimic

4) Short
Alarms
Copyright Schneider Electric Page 6
Internal
• HMI Custom General Electric View
General View Mimic : (Substation, Voltage Level, …)

Fully configurable
Copyright Schneider Electric Page 7
Internal
• EPAS HMI Title Bar
Company logo animated by EPAS HMI User and Profile names are updated
Server State after logging in or out.

Substation Name
defined into the SCE Time and Date are given by PC
synchronised by HMI Server

EPAS

Connected HMI server icon displaying SBUS coupling status


for this HMI client between EPAS HMI Server and the SBUS
agency

Mode status, Substation control mode.


•Remote substation driven from RCP.
•Local substation driven through EPAS HMI.
Copyright Schneider Electric Page 8
Internal
• EPAS HMI (OI type) Command Bar
Opens the Password Launches Operator Stops the EPAS HMI
Utility dialog box. Station tools Client.
Short cut : F10
Indicates if at least
one memo is active Launches
in mimics. EPAS SMT
HMI

Opens the User


Management dialog
Archive
box.
Restore

Alternately Log in and Prints :


Stops audible •full screen (F5)
Log off (default user
alarms
profile). Short cut : F2 •active mimic (Shift+F5)
Copyright Schneider Electric Page 9
Internal
• Session Banner – EcoSUI type

Copyright Schneider Electric Page 10


Internal
• HMI Custom General Electric View
General View Mimic : (Substation, Voltage Level, …)
▪ Electrical controllable devices (Various representations : IEC, ANSI,
customised)
▪ Measurements, Viewers, Memos, Navigation buttons ...

Fully configurable
Copyright Schneider Electric Page 11
Internal
• HMI Custom Bay View
Detailed Bay Mimic :
▪ Electrical controllable devices (Various representations : IEC, ANSI,
customised)
▪ Measurements, Viewers, Memos, Navigation buttons ...

Fully configurable
Copyright Schneider Electric Page 12
Internal
• Command popup
Direct Execute :
We have one Action.
DatapointName;0 or 1 -> Send 0 (OFF or RESET) or 1 (ON or SET) to the xPC

Select Before Operate :


We have 3 different Actions.
SBO_SELECT DatapointName;0 or 1 -> Select xPC
SBO_EXECUTE -> Execute xPC
SBO_CANCEL -> Cancel xPS Selection
The common usage is a popup with 4 buttons:
Button to Select Open
Button to Select Close
Button to Execute
Button to Cancel

Simulated Select Before Operate : (internally managed by EcoSUI)


We have 3 different Actions.
CMD_SELECT DatapointName;0 or 1 -> ‘Fake’ Select xPC
CMD_EXECUTE -> Execute xPC
CMD_CANCEL -> Cancel xPS Selection
The common usage is a Popup with 4 buttons:
Button to Select Open
Button to Select Close
Button to Execute
Button to Cancel

Suppress and Substitute:


But not FORCE

Copyright Schneider Electric Page 13


Internal
• HMI Custom System View
System View Mimic :
▪ EPAS System devices (MiCOM Computers, EPAS HMI, EPAS Gateway,…)
▪ IED (Protections, Measurement Centres, …)

Fully configurable
Copyright Schneider Electric Page 14
Internal
• Last detected Alarms

Copyright Schneider Electric Page 15


Internal
• Alarms viewer

Copyright Schneider Electric Page 16


Internal
• States Viewer

Copyright Schneider Electric Page 17


Internal
• Events Viewer

Copyright Schneider Electric Page 18


Internal
EPAS EcoSUI

PCL

Copyright Schneider Electric - CS&Q - EPAS Training - HMI Overview G-07


EcoSUI Suite

MCIS User and configuration interface


Sbus Server Acquisition software (tunneling IEC-61850 layer)
Supervisor Deployment software
Gateway Gateway IEC to OPC software (one way gateway)
MySQL Archive solution

MCIS is an HMI solution. Electric configuration have to be done in other


software.

Copyright Schneider Electric Page 21


Internal
EcoSUI Summary
•EcoSUI HMI is the operating interface of the MCIS solution
It communicates with other MCIS modules:

•SBUS Servers (Acquisition Module)


oGets Live values from SBUS equipment
oSends commands
•Central DB
oGets the configuration (the configuration is stored
locally on each computer. When MCIS starts, it first
checks if a new configuration is available and
downloads it if necessary)
oGets the alarm list, events & measurements

Each of these 3 modules can be installed on only one computer


(light project) or scattered around different computers. (Remark:
There is only one installation package. It installs all 3 modules on
the computer even if some of them are not used)

The maximum number of EcoSUI HMI is 24.

Copyright Schneider Electric Page 22


Internal
EcoSUI Suite
Upper ring

Monitoring & Control Interface Solution

Supervisor

Eco-Gateway MCIS =
Sbus Server = HMI Client
HMI Server
MCIS =
MySQL
HMI Client

Electric ring Electric ring Electric ring

MCIS component One way communication


Bidirectional communication
Other network Update configuration
Copyright Schneider Electric Page 23
Internal
Internal

You might also like