0% found this document useful (0 votes)
6 views2 pages

DEHA TEST KIT (1)

The MARICHEM DEHA Test Kit is designed to measure the concentration of the DEHA chemical compound in marine boiler condensate water, ensuring effective oxygen removal and passivation of metallic surfaces. The kit contains materials for 125 tests, with a recommended initial dosage of DEHA and guidelines for adjusting Oxyblock D dosage based on test results. Test results must be recorded and submitted monthly for evaluation by MARICHEM MARIGASES Worldwide Services.

Uploaded by

ankit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views2 pages

DEHA TEST KIT (1)

The MARICHEM DEHA Test Kit is designed to measure the concentration of the DEHA chemical compound in marine boiler condensate water, ensuring effective oxygen removal and passivation of metallic surfaces. The kit contains materials for 125 tests, with a recommended initial dosage of DEHA and guidelines for adjusting Oxyblock D dosage based on test results. Test results must be recorded and submitted monthly for evaluation by MARICHEM MARIGASES Worldwide Services.

Uploaded by

ankit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MARINE CHEMICALS & EQUIPMENT DIVISION BOILER WATER TREATMENT TEST KITS

DEHA TEST KIT TM

DESCRIPTION 4. Add 4 drops of DEHA-2 reagent, seal the glass


and mix.
MARICHEM DEHA TEST KIT is used for the determi-
nation of DEHA chemical compound in the Marine 5. Open the glass after 10 minutes and place it on
Boilers. The test is performed when Oxyblock D position B in the comparator.
is used in the Boiler’s Water as an Oxygen scav- 6. Slide the comparator until the colors match in
enger. The water sample tested is received from the inspection hole on top. Check the measure-
the condensate, as this way we can ensure that ments reading in the recess on the comparator
the product has been distributed into the system. reed.
The measurement is very simple and a residual of Mid values can be estimated.
DEHA is necessary to be maintained in the conden-
sate’s water. This indicates that dissolved Oxygen EVALUATION OF THE TEST RESULT
has been effectively removed and passivation has
been occurred on the metallic surfaces of the boil- The test will give us the DEHA concentration in ppm
er system. in the condensate water and considering its value
we can increase or decrease Oxyblock D dosage.
Test is performed in the condensate water as we
TEST KIT CONTENTS
wish to ensure that DEHA has been distributed into
Contents of the test kit are sufficient for 125 mea- the system.
surements with a range between 0.01-0.30 ppm. The product has the ability to passivate the me-
A. Accessories tallic surfaces of the condensate system. For the
• 2 Screw-plug measuring glasses application of the product follow the following rec-
• 1 Slide comparator. ommendations:
• 1 Color Chart. Initial Dosage: 150ml/day in DEHA for untreated
• 1 Plastic Syringe of 5 ml Boiler systems.
B. Reagents DEHA residual in the Condensate System: 0.10-
• 1 bottle of 30ml DEHA-1 0.25ppm.
• 1 bottle of 25ml DEHA-2 Maintenance dosage: 100-200ml/day depending
in condensate DEHA concentration value.
PACKAGING After initial dosage has been introduced into the
Order Number : 700120 system, the test must be performed after 3 – 6
hours. Then the test must be performed on a daily
Container : Plastic Case
basis. Once the system stabilized the number of
measurements could be switched to 3 measure-
TESTING PROCEDURE ments per week.
1. Collect the Water sample from the Condensate Successful DEHA treatment requires the Boiler’s
System and cool it to 20-25°C. Please consider Feedwater Temperature to be close to its boiling
that it is critical for the determination of DEHA to point (90°­C - 95°C) as in this manner the water
perform immediately the test after sample’s re- releases most of its dissolved Oxygen. DEHA in this
ceipt. The reagents below should be added within case remains free to act in the Boiler’s Water, dis-
a period of 2-3 minutes to get an accurate and real tributed with the steam and could easily passivate
result. Do not leave the sample for long time open the metallic surfaces.
to the atmosphere as the DEHA will be lost.
2. Pour a 5 ml water sample into each of the mea-
suring glasses using the plastic syringe. Place a
measuring glass on position A in the comparator.
3. Add 4 drops of DEHA-1 reagent, seal the glass
and mix.

MARICHEM® Section E, Part 1


BOILER WATER TREATMENT TEST KITS MARINE CHEMICALS & EQUIPMENT DIVISION

TABLE 1

ppm DEHA in the


0 – 0.10 0.10 – 0.25 0.25 – 0.30 or higher
condensate sample

Dosage Oxyblock D
Increase dosage by 25% Satisfactory Reduce dosage by 25%
product

ADDITIONAL INFORMATION
For higher DEHA concentrations the dilution of
the sample should be done by Deareated water
(no Dissolved Oxygen). The De ionized water con-
tains dissolved Oxygen and during the dilution
could decrease DEHA in the final solution giving a
wrong result. For further information on the above
please come in contact with Marichem Marigases
Technical Department.
After the test results are obtained must be re-
corded in the Marichem Boiler Water Treatment Log
Sheet. At the end of every month, these Log Sheets
should be submitted by the head engineer to the
owner company, who in turn should send them to
MARICHEM MARIGASES WORLDWIDE SERVICES for
further evaluation and technical analysis.
For more information and literature concerning the
DEHA TEST KIT measurements and the Boiler Water
Treatment program you also may contact Marichem
Marigases Technical Department.

Read the Material Safety Data Sheet before using this product.
For detailed information on safety and health, please refer to Material Safety Data Sheet and/or Product Label.

MARICHEM MARIGASES Worldwide Services or any subsidiary or associated companies warranties of merchantability and competence, if any, along
with any expressed warranties concerning this merchandise, shall not be actionable or pertinent or effective if the good is used contrarily or differently
to the directions herein and in no other way due to impending hazards from inappropriate use of the good explained herein. Merchandise might vary
insubstantially depending on country of origin. The information provided concerning merchandise is exclusively presented to the customer.

Section E, Part 1