GENERAL PUMP A member of the Interpump Group
EP Series
Triplex Plunger Pump, Solid Shaft, 1750 RPM
FEATURES
• Triplex plunger pump
• New Forged brass manifold , increases
working pressure to 4,000 PSI
TRIPLEX
• New plunger guide bushing
(patent pending)
• Solid ceramic plungers with dual guide
system
• New dual diameter plunger guide
• New optimized outlet valves
• New dual lip oil seal
SPECIFICATIONS
Pump Model EP1313S17 EP1510S17 EP1512S17 EP1513S17 EP1810S17 EP1811S17 EP1812S17 EP1813S17
Maximum Volume 2.4 / 4.0 GPM 2.4 / 4.2 GPM 2.9 GPM 3.2 GPM 3.4 GPM 3.7 GPM 4.0 GPM 4.2 GPM
Maximum Discharge Pressure 4,000 PSI 3,045 PSI 2,500 PSI 2,900 PSI
Horsepower 6.4 HP 4.9 HP 6.0 HP 6.5 HP 5.7 HP 6.2 HP 6.6 HP 8.3 HP
Maximum Pump Speed 1750 / 3400 RPM 1750 RPM
Maximum Inlet Pressure 125 PSI
Max. Inlet Vacuum 3 ft. water (2.6 Hg)
Plunger Bore (in / mm) .512 in./13mm .591 in./15 mm .709 in./18 mm
Plunger Stroke (in / mm) .512 in./13mm .394 in./10 mm .472 in./12 mm .512 in./13 mm .394 in./10 mm .433 in./11 mm .472 in./12 mm .512 in./13 mm
Oil Capacity 15 oz.
Maximum Fluid Temperature 165º F
TRIPLEX
Inlet Port Thread 1/2”-14 BSP-F
Discharge Port Thread 3/8”-19 BSP-F
Shaft Diameter .945 in./24 mm
Weight 15.4 lbs.
Dimensions - Nominal 9.5”x8.38”x5.1”
General Pump
is a member of
the Interpump Group Ref 300919 Rev. K
04-24
GENERAL PUMP A member of the Interpump Group EP Series
Solid Shaft - 1750 RPM
Instructions and Recommendations for the Installation of
EP Series Pumps
Maximum temperature of the water through the pump the pump, for example for a 4 gpm (15 l/min)
is 165oF (73oC). pump, put a filter from 16 to 20 gpm (60-
75 l/mi)The mesh size suitable for this
In order to obtain maximum performance in terms of application is 0.016” (.4 mm).
duration of seals and valves, it is necessary to respect
a few simple rules, as follows: c) It is extremely important to put a pressure
1) In order to avoid damage caused by cavitation, switch on the suction port of the pump, and in
the pump must be pressure fed. any case downstream from the filter, so that
it can stop the pump should the feed pressure
The higher the inlet pressure, the longer the life of drop by 20% due to the filter clogging or
the wet end of the pump. failure of the feed pump, etc.
When working at 165oF (73oC), the minimum 3) Change of oil
feed pressure - measured directly in the inlet port
of the pump when it is working - is 45 psi (3 bar). We recommend the first oil change after the
first 50 hours, with the pump stopped and
The minimum feed pressure according to the the oil still warm.
different temperatures are:
This change is not recommended because the oil
has lost its properties, but rather to eliminate the
impurities that have gotten into the oil during the
running-in phase. If these impurities are not
removed, but are allowed to remain in the oil, they
may cause premature wear to the moving parts
and the oil seals. After this initial change, the
oil can then be changed every three months
or 300 hours of operation thereafter.
Please note: If the pump works in conditions with
high humidity and with sharp temperature
Naturally, if the application allows for feeding the changes, it is possible that condensation will
pump with 45 psi (3 bar) even at low temperatures appear inside the crankcase, which mixing with
(for example: 115oF/45oC the life of the wet end of the the oil can change its properties. This is easy
pump will be even longer. to see because the oil changes to a white, milky
color.
2) The plumbing which feeds the pump must be
of a diameter at least equal to the inlet port. If the pump does not have excessive water
Also, follow the suggestions below: leaking from the packings, and the oil becomes
milky, the oil has to be changed more frequently.
a) Make the plumbing as short and straight as The percentage of water in the oil must not
possible, preferably in an upward direction to exceed 20%.
facilitate the expulsion of eventual air bubbles
naturally if compatible with the requirements Use oil per the following chart:
of the system. CHART OF COMPATIBLE OILS
General Pump Series 100
b) It is always useful to put a filter at the inlet BP VISCO 2000
with capacity of 4 to 5 times the flow of CASTROL CWX
MOBIL SUPER
SHELL HELIX SUPER
Ref 300919 Rev. K
04-24
TOTAL QUARTZ 4000-5000
GENERAL PUMP A member of the Interpump Group EP Series
Solid Shaft - 1750 RPM
PARTS LIST
ITEM PART NO. DESCRIPTION QTY ITEMPART NO. DESCRIPTION QTY ITEM PART NO. DESCRIPTION QTY
1. 58120041 Manifold, Ø 13 1 90265300 Packing, Ø 18, HP 3 42. 90063500 Stop Ring Ø 25 2
58120141 Manifold, Ø 15 1 710031 Packing, Ø 15, HP 3 43. 99183700 Screw, M6x14 12
58120241 Manifold, Ø 18 1 (K276H, K3121H) 44. 53210851 Oil Level Indicator 1
2. 36202551 Valve Cage 3 24. 90507650 Anti-ext. Ring, Ø 13 3 45. 63021265 Cranksfaft, 10mm 1
3. 94737600 Spring, Ø 9.4x14.8 3 90508990 Anti-ext. Ring, Ø 15 3 (EP1510S, EP1810S)
4. 36711501 Valve 3 90511150 Anti-ext. Ring, Ø 18 3 63021665 Crankshaft, 12mm 1
5. 36200366 Valve Seat 3 25. 58605601 Intermed. Ring, Ø 13 3 (EP1512S17, EP1812S17)
6. 701115 O-ring, Ø17.13v2.62 3 58605701 Intermed. Ring, Ø 15 3 63021865 Crankshaft, 1
7. 36711501 Valve Assembly 3 58605801 Intermed. Ring, Ø 18 3 (EP1513S17, EP1813S17, EP1313S17)
8. 701002 O-ring, Ø20.24x2.62 3 26. 701023 O-ring, 26.7x1.78 3 63029165 Crankshaft 1
9. 98222600 Valve Cap, M24x1.5x16.7 3 28. 90260100 Seal, Ø 13, LP 3 (EP1811S17)
10. 99169000 Plunger Bolt, M5x55 3 90260800 Seal, Ø 15, LP 3 46. 91833100 Bearing, Premium 2
11. 96690500 Washer, Ø 5x11.5x0.4 3 90265000 Seal, Ø 18, LP 3 47. 90389800 O-ring, Ø 56.82x2.62 1
12. 58040009 Plunger, Ø 13x42 3 710030 Seal, Ø 15, LP 3 48. 90164100 Oil Seal, Ø 25x62x10 1
58040109 Plunger, Ø 15x42 3 (K276H, K3121H) 49. 91489200 Key 1
58040209 Plunger, Ø 18x42 3 29. 58210670 Support Ring, Ø 13 3 50. 98210500 Oil Dipstick 1
13. 701014 O-ring, Ø 12.42x1.78 3 58210770 Support Ring, Ø 15 3 51. 90392550 O-ring, Ø 113.97x2.62 1
14. 36211366 Outlet Valve Seat 3 58210870 Support Ring, Ø 18 3 52. 58160022 Rear Cover 1
15. 36211276 Outlet Valve Poppet 3 30. 98210000 Plug, 3/8”x13 1 53. 98204100 Plug, 1/4”x9 1
16. 94733300 Spring, Ø 6.2x10.4 3 31. 96738000 Gasket, 17.5x23x1.5 1 54. 701013 O-ring, Ø 10.82x1.78 1
17. 36211151 Outlet Valve Cage Guide 3 32. 98217600 Plug, 1/2” BSPx10 1 55. 98196600 Plug, 1/8”x8 1
18. 36719301 Complete Outlet Valve 3 33. 96751400 Gasket, Ø 21.5x27x1.5 1 56. 99303700 Screw, Hex Head 4
19. 701016 O-ring, Ø 15.6x1.78 3 34. 96698000 Washer, Ø 7.5x15x0.5 3 57. 96701600 Washer, Ø 8.4 4
20. 98213700 Outlet Valve Cap, M18x1.5x10 3 35. 58210582 Gasket, Ø 3x94 1 58. 50200074 Pump Foot 2
21. 99317500 Screw, M8x60 8 36. 58010022 Crankcase 1 59. 90385900 Stop Ring 1
22. 44100251 Head Ring, Ø 13 3 37. 58210451 Drip Cover 1 60. 90067100 Stop Ring 1
63101051 Head Ring, Ø 15 3 38. 90156550 Oil Seal, Ø 15x24x5.7 3 61. 58150122 Side Cover 1
63101151 Head Ring, Ø 18 3 39. 58050066 Piston Guide 3
23. 90260200 Packing, Ø 13, HP 3 40. 97734000 Piston Pin, Ø 10x29.5 3
90261100 Packing, Ø 15, HP 3 41. 58030022 Connecting Rod 3
* 53150001 Oil Level Indicator Assembled W/O Screws and O-ring
Ref 300919 Rev. K
04-24
GENERAL PUMP A member of the Interpump Group EP Series
Solid Shaft - 1750 RPM
REPAIR KITS TORQUE SPECS*
Position Ft.-Lbs. Nm.
Ø 13 Ø 15 Ø 18 9 96 130
KIT NO. K269 K270 K271
K312H¹ K276H¹ 10 4.5 6
K272 K275 K273 K276 K274 K277
(Hot Kit) (Hot Kit) 20 44.3 60
2, 3, 4, 5, 21 14.8 20
22, 23, 22, 23, 22, 23, 22, 23,
ITEM NO’S 6, 13, 14, 8, 9, 22, 23, 22, 23, 22, 23,
24, 25, 24, 25, 24, 25, 24, 25, 30** 30 40
INCLUDED 15, 16, 19, 38 24, 26, 24, 26, 23, 28 24, 26,
IN KIT 26, 28, 26, 28, 26, 28, 26, 28, 32 30 40
17, 20 28 28 28
29 29 29 29
(7), (18) 43 7.4 10
NUMBER OF 53 14.8 20
ASSY’S 6 6 3 3 1 3 1 3 3 3 1
IN KIT 55** 9.6 13
NO. OF 56 14.8 20
CYLINDERS 3 3 3 3 1 3 1 3 3 3 1
KIT SERVICES *Decrease torque by 20% if threads are lubricated.
**Use Loctite 542 Red
¹ Note: Seal tool included
DIMENSIONS
WARNING: High Pressure Systems require a primary pressure regulating
WARNING: This product can expose you to chemicals including
device (i.e. regulator, unloader) and a secondary pressure relief device lead, which is know to the state of California to cause cancer and
(i.e. pop-off valve, relief valve). Failure to install such relief devices birth defects or other reproductive harm. For more information, go
properly could result in personal injury or damage to pump or property. to www.P65Warnings.ca.gov
GP does not assume any liability or responsibility for the operation of the
user’s high pressure system.
GENERAL PUMP 1174 Northland Drive • Mendota Heights, MN 55120 Ref 300919 Rev. K
Phone: 651.686.2199 • Fax: 800.535.1745 • e-mail: [email protected] • www.generalpump.com 04-24