DR 100

The RD5100 Series Hybrid Chart Recorder is a 250 mm (10") device that offers high-speed scanning at 36 points per second and high accuracy of ±0.05%. It features various input types, superior ease of operation, and multiple communication interfaces, making it suitable for measuring various industrial values simultaneously. The recorder also includes advanced specifications for data recording, display, and alarm functionalities, ensuring reliable performance in diverse working conditions.

Uploaded by

sergioeulopez02
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views7 pages

DR 100

The RD5100 Series Hybrid Chart Recorder is a 250 mm (10") device that offers high-speed scanning at 36 points per second and high accuracy of ±0.05%. It features various input types, superior ease of operation, and multiple communication interfaces, making it suitable for measuring various industrial values simultaneously. The recorder also includes advanced specifications for data recording, display, and alarm functionalities, ensuring reliable performance in diverse working conditions.

Uploaded by

sergioeulopez02
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Hybrid Chart Recorder

250 mm (10")

RD5100 Series

U High Speed Scanning


at 36 Points/Sec and
High-Speed Recording
U High Accuracy of 0.05%
U Various Industrial Values
Can be Measured at
the Same Time with
Selectable Ranges
U Superior Ease of RD5110
Operation
U Engineering Port is Indication Accuracy: Refer to the table
Provided (USB) of inputs on page S-35d Series Mode Rejection Ratio: 50dB
U Anti-Noise Temperature Drift: 0.1% FS/ 10°C (only when the peak value of noise is
Countermeasures Measuring Period: 0.1 sec/channel below standard range)
Reference Junction Compensation Terminal Board: Detachable type,
U Communication Accuracy: removable for wire connection
Interfaces are Available K, E, J, T, N, Platinel II: ±0.5°C
U Recording and (33°F) or less [0°C (32°F) or more Recording Specifications
when measuring] Recording System: Raster scan
Calculation of Data system, 10-color wire dot printing
R, S, WRe5-WRe26, NiMo-Ni, U, L:
Communication Input ±1.0°C (34°F) or less [only when the Recording and Recording Color:
ambient temperature is 23°C (73°F) Analog Recording: Color can be
RD5100 series chart recorders are ±5°C (41°F)] specified for each channel as required
250 mm (10") hybrid recorders with Input Resolution: Approx. 1/40,000 10 colors (red, purple-red, orange,
multi-range input. Innovative design (standard range conversion) brown, green, yellow-green,
high performance recorder provides Burnout: Select with/without burnout blue-green, purple, purple-blue, black)
high accuracy, ±0.05%; high speed for each input Digital Recording and Logging
scanning, 0.1 second for 36 points Allowable Signal Source Resistance: Recording: Black
and high speed recording, 1 line in Message Printing: Black
Thermocouple Inputs, DC Voltage
3 seconds. Simple operational keys List Printing: Black
Input (10 mV): 500Ω or less
and PC setting functions drastically Chart Paper: Fan-fold type; overall
(without burnout)
improved usability of recording width 318 mm (12.5"), total length
DC Voltage Input (Except 10 mV):
system. 20 m (65.6'); effective recording width
100Ω or less
Resistance Thermometer Inputs: 250 mm (10") (analog recording)
Specifications 10Ω or less/ line, three lines are Chart Speed: 1 to 1500 mm/H
Input common, Pt100, JPt100 [in 1 mm/H steps]
Number of Measuring Points: Input Resistance: Skip Function: Analog recording, digital
12, 24 and 36 points Thermocouple Input, DC Voltage recording and digital display can be set
Input: Approx. 1MΩ independently from recording slip
Input Types: Universal (refer to the
table of inputs) Maximum Input Applied Voltage: Recording Compensation:
±20 Vdc Independent setting of zero spans
Range Setting: Input type and range
Input Correction: Zero/span correction are available
are set with front keys
Scale Setting: The minimum and and shift correction for each channel
Maximum Common Mode Coltage:
Display Specifications
Digital Display: Color LCD panel RGB
S
maximum values and unit are set for
each point with front keys 30 Vac (support LVD) (640 x 240 dot)
Setting Range: -30,000 to 30,000 Common Mode Rejection Ratio: Display Size: 149.8 W x 57.4 mm H
Decimal Points: Optional setting 130dB (5.8 W x 2.25" H)
S-35a
1ABC: Setting parameter value
1 and character of “ABC ”
Transportation Condition: At the
2DEF: Setting parameter value packed condition on shipment from
2 and character of “DEF” our factory
3GHI: Setting parameter value Ambient Temperature/Humidity
3 and character of “GHI” Range: -20 to 60°C (-4 to 140°F),
4JKL: Setting parameter value 5 to 90%RH (no dew condensation)
Setting Display: Common to 4 and character of “JKL” Vibration: 10 to 60 Hz, 4.9 m (16')/
digital display* 5MNO: Setting parameter value S2 (0.5G or less)
Display Contents: Digital display 5 and character of “MNO” Impact: 392 m (1.3')/S2
Channel Display: One-point/multiple 6PQR: Setting parameter value (approx. 40G or less)
points continuous/sequential 6 and character of “PQR” Storage Condition:
indication change 7STU: Setting parameter value Ambient Temperature: -20 to 60°C
Display Measuring Value of 7 and character of “STU” (-4 to 140°F), 5 to 90% RH (no dew
Each Channel: One-point/multiple 8VWX: Setting parameter value condensation)
points continuous/sequential 8 and character of “VWX” Working Condition:
indication change 9YZ: Setting parameter value Working Temperature Range:
Clock Display: Hour/Minute/ 9 and character of “YZ” 0 to 40°C (32 to 104°F)
Second/Tag/Unit Recording Operation: Working Humidity Range:
Chart Speed Display 20 to 80% RH
Record On/Off: Recording operation
Status Display: ON/OFF* Power Failure Protection:
Record On: Lights during Programmed parameters stored
Data Print: Printing measuring data*
recording; LED into EEPROM memory clock circuit
Feed: Fast-forwarding chart paper sustained for 5 years or longer by a
Key Lock: Lights during key lock * Two actions are taken to operate
Alarm: Lights during alarm lithium battery (at the operation of
activated; LED General Specifications 8 hours or longer per day)
Chart End: Lights just before Rated Power Voltage: 100 to 240 Vac Insulation Resistance:
record ending (universal power supply) 50/60Hz Between Primary Terminals and
Fail: Lights during unit abnormal time Maximum Power Consumption: 100V A Protective Conductor Terminals:
* Sharing LED and setting display Reference Operating Condition: 20MΩ or more at 500 Vdc
Alarm Specifications Ambient Temperature/Humidity Between Secondary Terminals and
Range: 21 to 25°C (70 to 77°F), Protective Conductor Terminals:
Alarm Display: Occurrence CH No, 20MΩ or more at 500 Vdc
data is displayed in red when 45 to 65% RH
Power Voltage: 90 to 264V Between Primary Terminals and
alarm occurs Secondary Terminals: 20MΩ or
Alarm Types: High limit, low limit Power Frequency: 50/60Hz ±2%
Attitude: Forward/Backward/left/right more at 500 Vdc
Alarm Setting Method: Individual Dielectric Strength:
within 3°
setting for each point four levels/ Between Primary Terminals and
Warm-Up Time: 1 hour or longer
channels Protective Conductor Terminals:
Normal Operating Condition:
Alarm Output: See option specification 1 minute at 1500 Vac
Ambient Temperature/Humidity
Setting and Operational Range: 0 to 40°C (32 to 104°F), Between Secondary Terminals and
Protective Conductor Terminals:
Specifications 20 to 80% RH
1 minute at 500 Vac
Key Types, Operation: Power Voltage: 90 to 264V
Power Frequency: 50/60Hz ±2% Between Primary Terminals and
Func1: Switching each function Secondary Terminals: 1 minute at
Attitude: Forward/backward/left/right
Func2: Switching each function within 3° 1500 Vac
Enter: Setting a change of parameter
for each mode
Menu: Specifying each setting Option Specifications
function Options Comments
Esc: Used to escape in the middle
of setting   External Drive Chart 3-speed, chart stop, data printing, list
printing, message printing 5 types, operation recording
s: Used to switch channels when
specifying the parameter on cursor Alarm Output Mechanical relay: 12, 24, 36 points output,
t: Used to switch channels when max contact capacity of 100 to 240 Vac, 3 A
specifying the parameter on cursor resistance load
: Used to move cursor to the right External Drive Chart 3-speed, chart stop, data printing, list printing,
s

: Used to move cursor to the left message printing 5 types, operation recording
s

Rec: Analog recording, digital Comm Interface RS422A or RS485 + Ethernet + 1a contact output
recording, printing, switching chart (1a contact output is contact output of mecha relay)
ON/OFF
Chart End Output Chart End relay output when chart paper ended
DataP: Digital recording of latest data (communication interface is required)
Feed: Fast-forwarding chart paper
Shift: Specifying key Fail Output Fail relay output when abnormality (communication
interface is required)
. _ =: Setting characters of “. _ =”
@ + -: Setting characters of “@ + -” Receiving 250Ω (for 20 mA) or 100Ω (for 50 mA) are externally
0 * /: Setting parameter value 0 and Resistance for mounted to measure current
character of “* / ” Current Input

S-35b
260 (10.24)
260 (10.24)

400 (15.75)

400 (15.75)

380.8 (14.99)
28.8 (1.13) 352 (13.86)

380.8 (14.99)
28.8 (1.13) 352 (13.86)

245.6 (9.67'') x 385.6 (15.18)


Dimensions: mm (inch)

245.6 (9.67'') x 385.6 (15.18)

Note 1:
Primary Terminals: Power terminal,
alarm output terminal, output relay
terminal
Secondary Terminals: Measuring 4-M5 The opposite face is the same
input terminal, communication
terminal, external drive terminal
Note 2: When testing insulation Communication
4-M5 The opposite Interface Specifications
face is the same
resistance and dielectric strength,
please short-circuit every terminals of Without
primary and secondary terminals before
With Communication Communication
Interface Interface
the test; test without short-circuiting
terminals can damage instruments Specification Ethernet10BASE-T/
Case Assembly Material: 100BASE-T, automated
Door (Frame): ABS resin recognition, TCP, IP, —
Front Panel: Soda glass HTTP, exclusive
Back Case: Normal steel Ethernet protocol
Color: Function Data display, parameter
Door (Frame): White (equivalent to setting, with browser
DIC546 1⁄2) data display, parameter —
Front Panel: Transparent setting on exclusive
Back Case: White (equivalent to application
DIC546 1⁄2) Specification RS422A, RS485,
Mounting: Panel mounting Communication
Weight: About 15 kg (33 lb) (full option) protocol: MODBUS
Dimensions: 400 W x 260 H x 300 mm D communication —
(15.7 W x 10.2 H x 11.8" D) specification: 9600 bps
Panel Cut Dimensions: 388 x 248 mm RS422A to 19200 bps 7E1 to 8N2
(15.2 x 9.7") RS485 Function Data display and
Terminal Screws: parameter setting
Measuring Input, Alarm —
using exclusive
Terminals: M3.5
Power, Protective Conductor
application S
Terminal, External Drive Terminal,
Specification Inside of front door, USB1.1, full speed
Communication Terminal: M4
USB 12 mbps, bulk transfer, Control transfer
Chart Paper Illumination: White LED Function Parameter setting for exclusive application

S-35c
Communication Interface Specifications
Input Measuring Reference Accuracy Display
Signals Ranges Ranges Ratings Resolutions
-10.0 to 10.0 mV ±10 mV
1 µV
-20.0 to 20.0 mV ±20 mV
-40.0 to 40.0 mV ±40 mV
10 µV
DC Voltage -80 0 to 80.0 mV ±80 mV ±0.05% ±1 digit
±0.05% ±1 digit
-1.25 to 1.25V ±1.25V
100 µV
-2.5 to 2.5V ±2.5V
-5.0 to 5.0V ±5V
1 mV
-10.0 to 10.0V ±10V
-200 to 500°C (-328 to 932°F) ±20 mV
±0.05% ±0.5°C (±33°F)
-200 to 900°C (-328 to 1652°F) ±40 mV
-200 to 1370°C (-328 to 2498°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 250°C (-328 to 482°F) ±20 mV
±0.05% ±0.7°C (±33.2°F)
-200 to 500°C (-328 to 932°F) ±40 mV
-200 to 900°C (-328 to 1652°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 350°C (-328 to 662°F) ±20 mV
±0.05% ±0.7°C (±33.2°F)
-200 to 700°C (-328 to 1292°F) ±40 mV
-200 to 1200°C (-328 to 2192°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 400°C (-328 to 752°F) ±20 mV ±0.05% ±0.7°C (±33.2°F)
0 to 1760°C (32 to 3200°F) ±20 mV
Thermocouples

±0.05% ±1°C (±34°F)


0 to 1300°C (32 to 2372°F) ±20 mV
0 to 600°C (32 to 1112°F) ±20 mV
±0.1% ±0.1°C (±32°F)
0 to 1000°C (32 to 1832°F) ±40 mV 0.1°C (32°F)
0 to 1300°C (32 to 2372°F) ±80 mV
W-WRe26 0 to 2315°C (32 to 4199°F) ±80 mV
PrRh40- ±0.1% ±1°C (±34°F)
PtRh20 0 to 1888°C (32 to 3430°F) ±20 mV
NiMo-Ni -50 to 1310°C (-58 to 2390°F) ±80 mV
0 to 500°C (32 to 932°F) ±20 mV ±0.1% ±0.1°C (±32°F)
Platinel II 0 to 950°C (32 to 1742°F) ±80 mV
±0.1% ±1°C (±34°F)
0 to 1395°C (32 to 2543°F) ±80 mV
UU
-200 to 350°C (-328 to 662°F) ±20 mV
-200 to 600°C (-328 to 1112°F) ±40 mV
-200 to 350°C (-328 to 662°F) ±20 mV ±0.05% ±1°C (±34°F)
-200 to 700°C (-328 to 1292°F) ±40 mV
-200 to 900°C (-328 to 1652°F) ±80 mV
-50 to 50°C (-58 to 122°F) 50Ω
-100 to 130°C (-148 to 266°F) 100Ω
Pt100
-200 to 250°C (-328 to 482°F) 200Ω
RTDs

-200 to 550°C (-328 to 1022°F) 300Ω


±0.05% ±0.3°C (±32.5°F) 0.1°C (32°F)
-50 to 50°C (-58 to 122°F) 50Ω
-100 to 130°C (-148 to 266°F) 100Ω
JPt100
-200 to 250°C (-328 to 482°F) 200Ω
-200 to 550°C (-328 to 1022°F) 300Ω
Note 1: Ambient temperature/humidity range: 23°C ±2°C
Note 2: For thermocouple input, the accuracy of reference junction compensation is not included with the accuracy ratings.
Note 3: Accuracy rating is the percentage of measuring range K, E, J, T, R, S, B, N: IEC584, JIS C 1602-1995; W-Wre26, Wre5-WRs26,
PtRh40-PtRh20, NiMo-Ni, Platinel?: ASTM Vol.14.03; U(Cu-CuNi), L(Fe-CuNi): DIN43710; Pt100: IEC751, JIS C 1604-1997;
JPt100: JIS C 1604-1981, JIS C 1606-1986
S-35d
Terminal Board

Resistance thermometer terminal B


Thermocouple DC voltage (-) resistance thermometer B
Thermocouple DC voltage (+) resistance thermometer A
Upper Comm: RS422A/RS485 terminal
Power terminal Comm. between instruments RS485 terminal
100 to 240V 50/60 Hz Ethernet connector
Output relay terminal

Ext. drive terminal

Measuring input terminal Alarm output terminal

Exceptions of Accuracy Ratings


Input Signals Measuring Ranges Accuracy Ratings
  K, E, J, T, L -200 to 0°C (-328 to 32°F)
±0.2% ±1 digit
R, S 0 to 400°C (32 to 752°F)
0 to 400°C (32 to 752°F) None
B
400 to 800°C (752 to 1472°F) ±0.15% ±1 digit
U -200 to 0°C (-328 to 32°F)
±0.3% ±1 digit
W-WRe26 0 to 300°C (32 to 572°F)

PrRh40-PtRh20
0 to 300°C (32 to 572°F) ±1.5% ±1 digit S
300 to 800°C (572 to 1472°F) ±0.8% ±1 digit
NiMo-Ni -50 to 100°C (-58 to 212°F) ±0.2% ±1 digit
Note: Refer to thermocouple input accuracy is calculated based on standard range, see previous page.

S-35e
SM OMEGACARESM extended warranty program
is available for models shown on this page.
Ask your sales representative for full details
Extended Warranty when placing an order. OMEGACARE
SM

Program covers parts, labor and equivalent loaners.

1 channel display

Engineering and USB port


12 channels simultaneous display

Operation key pad


36 channels simultaneous display

To Order
Model No. Description
RD5110 250 mm (10") 12-points hybrid chart recorder
RD5120 250 mm (10") 24-points hybrid chart recorder
RD5130 250 mm (10") 36-points hybrid chart recorder
RD5111 250 mm (10") 12-points with 12 alarms hybrid chart recorder
RD5112 250 mm (10") 12-points with 24 alarms hybrid chart recorder
RD5121 250 mm (10") 24-points with 12 alarms hybrid chart recorder
RD5122 250 mm (10") 24-points with 24 alarms hybrid chart recorder
RD5131 250 mm (10") 36-points with 12 alarms hybrid chart recorder
RD5132 250 mm (10") 36-points with 24 alarms hybrid chart recorder
RD5133 250 mm (10") 36-points with 36 alarms hybrid chart recorder
RD5110-COMM 250 mm (10") 12-points hybrid chart recorder with communications
RD5120-COMM 250 mm (10") 24-points hybrid chart recorder with communications
RD5130-COMM 250 mm (10") 36-points hybrid chart recorder with communications
Comes complete with operator’s manual.
Ordering Example: RD5110, 250 mm (10") hybrid chart recorder.
OCW-3, OMEGACARESM extends standard 2-year warranty to a total of 5 years.

Accessories
Model No. Description
RD5100-RC 10-color ribbon cassette, package of 5
RD5100-CP-0/100 Z-fold chart paper 250 mm x 20 m (9.8" x 65.6'), case of 15
RD9900-ZAILA ZAILA data analysis software
RD2800-PASS Parameter programming software
RD2800-KIDS Data acquisition software

S-35f
Parámetro Especificación Omega RD5100 (RD5120)
N° de puntos 24 12–36 canales, incluye modelo de 24
medición canales
Tipo de entrada Universal (termopar, Termopar y DC Voltage, universal
voltaje DC) input
Configuración de Teclas frontales Configuración mediante
rango teclas/manual/PC
Rango de ajuste –25,000 a 25,000 Rangos DC ±20 V, termopar con
compensation
Puntos decimales Opcional Display digital y analógico con ajuste
de visualización
Periodo medición 0.1 seg/canal Scan rápido: 36 pt/s = 0.028 s/pt
Precisión ±0.5 °C K: ±0.05%±0.5 °C, E:
termopar K, E, J ±0.05%±0.7 °C, J: ±0.05%±0.7 °C
Precisión R, S ±1 °C R/S: ±0.05%±1 °C
Impedancia ≈1 MΩ 1 MΩ input resistance
entrada
Voltaje máximo ±20 V DC Max input ±20 V DC
entrada
Sistema de Escaneo, 10 colores Scan multicanal, cinta fanfold con
registro plotter de color (10 colores)
Papel gráfico Fanfold, 12.5″ × 20 m Fan-fold 318 mm (12.5″) ×20 m
Velocidad registro 5–1000 mm/h 1–1 500 mm/h
Pantalla LCD color RGB 149.8 mm×57.4 mm = 5.9″×2.26″
5.8″×2.25″ LCD RGB
Modo 1 o múltiples puntos Digital display con uno o múltiples
visualización continuos canales contínuos/sequenciales
display
Grabación y LED durante LED para recording y alarm estado
alarma (LED) grabación/alarmas

You might also like