Manual Tension SKF
Manual Tension SKF
Switch off and isolate any belt drive system prior to taking tension measurements or attempting any other installation work. Do not drop the meter or subject either the meter or the optical sensor to other sharp impact. Do not put water, solvents (including cleaning solutions) or any other liquid on the unit. Clean meter and sensor with dry cotton cloth. Do not pull on sensor cord. Disconnect sensor from meter by grasping the connector grip only.
Do not leave the unit in places that are humid, hot, dust filled or in direct sunlight. Hint: When SKF Belt Frequency Meter is not used for a while, remove batteries and store unit in the case provided. Do not use your SKF Belt Frequency Meter in any potentially explosive environment. Do not disassemble or attempt to modify either the meter or the sensing head.
Table of contents
1.0 Device description 2.0 Quick start 3.0 Functions 3.1 Keys 3.2 Audio/ visual display 3.3 Optical sensor 3.4 Battery condition 3.5 Charging batteries 4.0 Setup & use 5.0 Operating tips 6.0 Meter range 7.0 Calibration 7.1 Spot check 7.2 Annual certification 8.0 Technical specification 9.0 Useful formulae and conversions Appendix 1.0 Theory of operation 2.0 Weights and tension values 19 20 15 16 17 18 6 7 8 9 10 11 13 14 page 4 5
1. Plug in sensor
3.0 Functions
3.1 Keys
ON/OFF
This key switches the meter on or off. If the meter is on and sits idle for more than 3 minutes, it automatically switches off to preserve battery life. When the meter is first switched on a battery check is made see Section 3.4 for a description of the visual and audible low battery signal.
SPAN (m)
This key is used to enter the belt span length. The span key is held down while the UP or DOWN keys are used to set the belt span in metres. Releasing the SPAN key results in an audible beep to indicate the setting has been accepted. Pressing the SPAN key alone, shows the current setting. This key is used to enter the belt mass. The mass key is held down while the UP or DOWN keys are used to set the belt mass in kg/m. Releasing the MASS key results in an audible beep to indicate the setting has been accepted. Pressing the MASS key alone shows the current setting.
MASS (kg/m)
Important Note: Belt span and belt mass are required entries if tension results in force units (N or lbf) are desired. Entries must be in SI units (m and kg/m)
UP (Hz/N)
This key has two functions. The first is to increase either the SPAN or MASS parameters when used in conjunction with these keys. The second use is to toggle between the Hz and the newton measurement modes.
DOWN (Lbs)
This key has two functions. The first is to decrease either the SPAN or MASS parameters when used in conjunction with those keys. The second use is to toggle between the Hz and the pound measurement modes. The memory keys allow up to 3 sets of belt parameters to be stored in the meter registry. Pressing the MEM 1 key recalls the first set of belt parameters and likewise for MEM 2 and MEM 3. To store the belt parameters to a key, the belt span and mass parameters must first be entered and then immediately after release of either the SPAN or MASS keys the appropriate MEM key should be pressed. Two beeps indicate that the parameters have been successfully assigned to the key.
MEM 1
MEM 2
MEM 3
Frequency mode, results displayed as hertz Tension displayed in newton Tension displayed in pound-force.
Audible signals
Signal One Beep One Beep One Beep Two Beeps When Upon release of Span key Upon release of Mass key While sensor is aimed at vibrating belt Upon pushing Memory key after releasing Span key Upon pushing Memory key after releasing 'Mass' key Four Beeps Combined with 0000 N display Combined with 0000 lb display After pushing On key combined with zero countdown Means Input accepted Input accepted Measurement taken Span data has been stored Mass data has been stored Newton result is out of range Pound result is out of range Low battery condition 7
If these signals are seen and heard, batteries should be replaced. Batteries are accessed through the removable cover on the back of the meter. New batteries should be inserted within 30 seconds of removal of old batteries. Taking longer risks loss of any data stored by the memory keys. Batteries are expected to provide approximately 20 hours of continuous operation before replacement is required.
10
ON/OFF
3. Load span and mass data or recall previously loaded data. To load span data simply hold down
UP (Hz/N) SPAN (m)
while using
or
DOWN (Lbs)
When the correct number appears in the display window, simply release the span key. The unit will beep once to acknowledge acceptance of this setting. To load mass data simply hold down
UP (Hz/N) MASS (kg/m)
while using
or
DOWN (Lbs)
When the correct number appears in the display window, simply release the mass key. The unit will beep once to acknowledge acceptance of this setting. To save individual entries into memory, press appropriate key
MEM 1
MEM 2
or
MEM 3
As soon as the span or mass keys have been released, the meter will beep twice to acknowledge the entry into memory. 11
MEM 1
MEM 2
or
MEM 3
, depending upon
where you stored the data for this specific drive. Afterwards press span or mass key in order to display the appropriate saved value (mass or span). 4. Aim sensor at centre of selected belt span. Tap or pluck the belt. The meter will beep once to indicate that a measurement was taken.
Gap 10 to 50 mm
Note: Pressing the same key a second time will return display to the hertz value. 8. Re-adjust belt tension and repeat measurement until target tension results are attained.
12
13
A '0000' newton reading accompanied by four 'beeps' indicates the result is out of range A '0000' pound reading accompanied by four 'beeps' indicates the result is out of range
On multi-shaft (three or more shafts) it may be possible to get valid measurements by selecting a different belt span for measurement. If the measured frequency is below 10 Hz choose an available shorter span. If the measured frequency is above 400 Hz choose a longer span if available. Based upon the measured belt frequency, the meter is capable of calculating belt tensions up to 9 990 N (2 200 lb.). When these limits are exceeded the meter will react as previously described. Belt tensions greater than these values are unusual. It is therefore advisable to check that the span and mass parameters have been entered correctly. If they are found to be correct then check the calculation of your target values. If everything looks correct then this drive is simply beyond the capacity of the SKF Belt Frequency Meter. The drive will have to be tensioned by traditional force and deflection techniques. Special Note: Tensioning a drive generally involves moving one component shaft with respect to another. On some drives, especially larger installations, tensioning the drive will involve sufficient movement that the span length is appreciably altered. Frequency (Hz) values will remain accurate but if a precise tension value is to be calculated it may become necessary to update the span input to reflect the new shaft spacing.
14
7.0 Calibration
7.1 Spot check
The measurement system of the SKF Belt Frequency Meter is based upon a very stable quartz crystal that should never wander. However, a precision mechanical resonator (tuning fork) is included with the meter so that a calibration check at a spot frequency of 250 Hz may be performed at any time.
Tap the tip of the tuning fork on a hard surface and then hold STEADY in front of the optical sensor at a distance of 10 to 15 mm. The meter will measure a frequency of 250 Hz thus demonstrating that it is in calibration.
Results within 1% are acceptable. There is no adjustment possible. If greater variance is experienced, the meter should be returned for calibration. See section 7.2 for manufacturers contact information.
15
16
17
S=
CD2 -
(D - d)2 4
where: S = Span length (mm) CD = Center distance (mm) D = Large pulley diameter (mm) d = Small pulley diameter (mm) Weight (for mass calculation use) ounce x 0,02835 = kg pound x 0,45359 = kg Reminder: Belt span and mass inputs to the meter must be in SI units, m for the belt span and kg/m for the belt mass.
18
Appendix
1.0 Theory of operation
There is a direct relationship between belt tension and a belts natural frequency of vibration. As the tension is increased, the vibration frequency also increases. The relationship between tension and frequency has been determined to be:
T = 4ml 2 f 2
Where T = Belt tension (N) m= mass per unit length (kg/m) l = span length (m) f = vibration frequency (Hz) The SKF Belt Frequency Meter is a dual function tool. The optical sensing head uses an invisible infrared beam to detect vibration while the integral calculator determines the time base and performs the necessary calculations to support the results shown in the display window. The meter may be used with all power transmission belts regardless of type or construction.
19
STPD
Timing belts
20
Wrapped V, wedge and banded belts Belt type Smallest pulley diameter from mm Z 40 61 over A 75 91 121 B 105 141 C 175 231 D 305 401 SPZ 56 80 96 over SPA 71 106 105 140 90 120 175 140 220 230 400 400 510 79 95 60 incl. Speed range from rpm 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 860 2 501 860 2 501 500 1 741 500 1 741 200 851 200 851 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 860 2 501 860 2 501 860 2 501 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 1 740 3 000 1 740 3 000 850 1 500 850 1 500 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 incl. Belt tension per single belt* New belt Run in belt N 104 121 174 174 332 254 391 332 469 411 469 391 567 528 1 017 841 1 251 1 115 2 210 1 877 2 698 2 268 338 262 383 415 477 438 575 524 696 628 872 876 978 941 1 255 1 116 1 496 1 275 N 69 81 116 116 222 169 261 222 313 274 313 261 378 352 678 561 834 743 1 473 1 251 1 799 1 512 226 175 255 276 318 292 383 349 464 418 581 584 652 627 837 744 997 850 Mass Single belt Belt in a band** kg/m 0,051 n/a
0,115
0,150
0,193
0,260
0,320
0,417
0,669
0,870
0,076
n/a
0,134
0,155
0,223
0,272
251 over
21
Wrapped V, wedge and banded belts Belt type Smallest pulley diameter from mm SPC 200 355 incl. Speed range from rpm 500 1 741 500 1 741 1 000 2 501 1 000 2 501 500 1 741 500 1 741 200 851 200 851 1 740 3000 1 740 3 000 2 500 4 000 2 500 4000 1 740 3 001 1 740 3 001 850 1 500 850 1 500 incl. Belt tension per single belt* New belt Run in belt N 2 026 2 043 2 305 2 671 313 274 430 391 1 134 997 1 369 1 291 2 933 2 386 3 520 3 129 N 1 350 1 362 1 537 1 781 209 182 287 261 756 665 912 860 1 955 1 590 2 346 2 086 Mass Single belt Belt in a band** kg/m 0,354 0,394
356 over 3V 61 91 5V 171 276 8V 315 431 90 175 275 500 430 570
0,076
0,099
0,223
0,272
0,504
0,654
* Multiply the belt tension required for a single belt by the number of the belts in the banded belt unit to get total tension to apply. ** Multiply the mass of one belt in a band by the number of the belts in the banded belt unit to get total mass to apply.
22
Wrapped and narrow wedge belts Belt type Smallest pulley diameter Speed range Belt tension per single belt* New belt from mm SPZ-XP 56 80 96 over SPA-XP 71 106 141 over SPB-XP 107 160 251 over SPC-XP 200 356 over 3V-XP 61 91 5V-XP 171 276 8V-XP 315 431 90 175 275 500 430 570 355 159 250 105 140 79 95 incl. from rpm 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 860 2 501 860 2 501 860 2 501 500 1 741 500 1 741 1 000 2 501 1 000 2 501 500 1 741 500 1 741 200 851 200 851 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 1 740 3 000 1 740 3 000 2 500 4 000 2 500 4 000 1 740 3 001 1 740 3 001 850 1 500 850 1 500 incl. N 372 288 421 457 525 482 633 576 766 691 959 964 1076 1035 1381 1228 1646 1403 2229 2247 2536 2938 344 301 473 430 1247 1097 1506 1420 3226 2625 3872 3442 Run in belt N 249 193 281 304 350 321 421 384 510 460 639 642 717 690 921 818 1097 935 1485 1498 1691 1959 230 200 316 287 832 732 1003 946 2151 1749 2581 2295 Mass Single belt Belt in a band** kg/m 0,079 -
0,122
0,202
0,350
0,079
0,202
0,520
* Multiply the belt tension required for a single belt by the number of the belts in the banded belt unit to get total tension to apply. ** Multiply the mass of one belt in a band by the number of the belts in the banded belt unit to get total mass to apply. 23
Cogged raw edge V, wedge and banded belts Belt type Smallest pulley diameter from mm ZX 40 61 over AX 75 91 121 BX 85 106 141 CX 175 231 XPZ 56 80 96 over XPA 71 106 105 140 90 120 175 105 140 220 230 400 79 95 60 incl. Speed range from rpm 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 860 2 501 860 2 501 860 2 501 500 1 741 500 1 741 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 860 2 501 860 2 501 860 2 501 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 1 740 3 000 1 740 3 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 incl. Belt tension per single belt* New belt Run in belt N 119 139 199 199 372 293 450 391 508 450 430 372 626 547 763 645 1 310 1 056 1 408 1 291 362 299 438 418 499 469 657 598 796 718 997 897 1 116 1 075 1 435 1 330 1 596 1 455 N 80 93 133 133 248 196 300 261 339 300 287 248 417 365 508 430 873 704 939 860 241 199 292 279 332 313 438 399 531 478 665 598 744 717 957 886 1 064 970 Mass Single belt Belt in a band** kg/m 0,051 n/a
0,115
0,153
0,193
0,225
0,320
0,398
0,076
n/a
0,134
0,156
0,223
0,279
251 over
24
Cogged raw edge V, wedge and banded belts Belt type Smallest pulley diameter from mm XPC 200 355 incl. Speed range from rpm 500 1 741 500 1 741 1 000 2 501 1 000 2 501 1 000 2 501 1 000 2 501 500 1 741 500 1 741 1 740 3 000 1 740 3 000 2 500 4 000 2 500 4 000 2 500 4 000 2 500 4 000 1 740 3 001 1 740 3 001 incl. Belt tension per single belt* New belt Run in belt N 2 313 2 333 2 632 3 050 293 254 372 332 469 430 899 489 1 310 1 212 1 525 1 486 N 1 542 1 555 1 755 2 034 196 169 248 222 313 287 600 326 873 808 1 017 991 Mass Single belt Belt in a band** kg/m 0,354 0,548
356 over 3VX 55 61 91 5VX 110 171 276 60 90 175 170 275 400
0,076
0,102
0,223
0,252
* Multiply the belt tension required for a single belt by the number of the belts in the banded belt unit to get total tension to apply. ** Multiply the mass of one belt in a band by the number of the belts in the banded belt unit to get total mass to apply.
25
Ribbed belts Belt type Smallest pulley Speed range diameter mm PJ PK PL PM <80 >80 <95 >95 <150 >150 <250 >250 rpm n/a n/a n/a n/a Belt tension per one rib* New belt Run in belt N 67 90 139 178 216 312 672 912 N 45 60 93 119 144 208 448 608 Mass** Single belt kg/m 0,010 0,018 0,057 0,120
* Multiply the belt tension required for one rib by the number of the ribs in the ribbed belt unit to get total tension to apply. ** Multiply the mass of one rib by the number of the ribs in the ribbed belt to get total mass to apply.
26
SKF GmbH Gunnar Wester Str. 12, 97421 Schweinfurt Germany SKF is a registered trademark of the SKF Group SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Publication PUB PSD/I4 06749/3 EN January 2012 Printed in England on environmentally friendly paper.