This document is a Type Test Report for motor no. 3G1F2146713154, detailing its electrical design and performance characteristics. The motor has various ratings and efficiencies, with specific tests conducted including no-load, short circuit, and temperature rise tests. The report confirms compliance with relevant IEC standards and includes test results such as torque, input/output power, and temperature measurements.

Uploaded by

gilbertomjc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views1 page

3G1F2146713154B GP 132SMF4 400VD 50Hz 5,5kW 3GZF021013-240

This document is a Type Test Report for motor no. 3G1F2146713154, detailing its electrical design and performance characteristics. The motor has various ratings and efficiencies, with specific tests conducted including no-load, short circuit, and temperature rise tests. The report confirms compliance with relevant IEC standards and includes test results such as torque, input/output power, and temperature measurements.

Uploaded by

gilbertomjc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

V6.0.1 - 1.1.8668.

21305

Date of test: 1.3.2021


Type Test Report Date of Issue: 30.9.2023

Tests have been carried out for motor no. 3G1F2146713154,


which is identical in electrical design with motor type(s) Type: M3GP 132SMF 4
stated in this report. Product Code: 3GGP132260-_DK
Protection type: Ex tb IIIB T125C Db /
Ex tc IIIB T125C Dc /
Ex tb IIIC T125C Db /
Ex tc IIIC T125C Dc
Rating:
V Hz kW r/min A cos φ Duty
3~Motor 690 Y 50 5.5 1462 6.2 0.81 S1
Ins. Class F 400 D 50 5.5 1462 10.8 0.81 S1
660 Y 50 5.5 1457 6.5 0.82 S1
380 D 50 5.5 1457 11.3 0.82 S1
415 D 50 5.5 1465 10.5 0.80 S1
460 D 60 5.5 1767 9.4 0.80 S1
Eff class IE3 50Hz: IE3 - 89.6(100%) - 90.6(75%) - 90.6(50%)
60Hz: IE3 - 91.7(100%)
Winding resistance* Measured at Calculated at Insulation resistance after heat run at 52 °C Overload tests
21 °C 20 °C 23000 MΩ , tested at 1000 V Torque 160 % 15 s
U1 - V1 1.2790 Ω 1.2765 Ω
U1 - W 1 1.2787 Ω 1.2762 Ω
V1 - W 1 1.2787 Ω 1.2762 Ω

Withstand voltage test for winding 2209 V 1s

Performance tests* Torque Line Input Output


[Nm] U[V] f[Hz] I[A] P1 [kW] P2 [kW] n[r/min] cos φ h [%] s [%]
No-load test 399.9 D 50 4.76 0.14 0.04
Short circuit test 86.0 D 50 10.8 0.60 0.37

Temp. rise test S1 35.9 400.0 D 50 10.8 6.05 5.49 1461 0.81 90.7 2.61

Partial load points:


~75% load 26.9 400.0 D 50 8.67 4.52 4.15 1472 0.75 91.8 1.88
~50% load 17.9 400.0 D 50 6.82 3.02 2.78 1482 0.64 91.9 1.22
~25% load 8.9 400.0 D 50 5.42 1.56 1.39 1491 0.42 89.2 0.60
Temperature rise at performance tests* [°C] [K] Method Measurement method
Stator winding : 42 1 1 Resistance
Frame : 24 2 2 Thermocouples
Bearing D-end : 17 2 3 Thermometer

Ambient Temperature : 21 2

Starting current (IS / IN) : 7.13


Locked rotor torque (TL / TN) : 2.18

Current unbalance at full load: 1.12 %

On behalf of manufacturer
Tested by ABB Oy, IEC LV Motors, Strömbergin puistotie 5, 65320 Vaasa, Finland
The results stated in this report relate only to the item tested.
Tommi Pantti
Manufactured and tested acc. to IEC/EN 60034-1:2017 and IEC/EN 60034-2-1:2014 Method 2-1-1B. Test Floor Manager
Test laboratory is accredited acc. to SFS-EN ISO/IEC 17025:2017 by FINAS. Ref. T345.