CAESAR II Version 5.2 Quick Reference Guide
CAESAR II Version 5.2 Quick Reference Guide
(SUS)
iMc/Z < Sh + Sr - Sl (EXP)
2
.75i (Ma + Mb) PmaxDi
+
2 2 Z
Eff(D -D )
0 i
(OCC)
M = sqrt (M
x
2
+ M
y
2
+ M
z
2
)
S
r
= Minimum of 1.25 Sc + 0.25 Sh; F
r
R
s
-F
2
;
or F
r
(1.25R
1
+ 0.25R
2
)
The latter applies to temperatures over 370C; 425C for
Austenitic stainless steel
F
r
= Cyclic reduction factor
25 CAESAR II Quick Reference Guide
Norwegian
R
s
= Permissible extent of stress for 7000 cycles
R
1
= Minimum of Sc and 0.267 R
m
R
2
= Minimum of Sh and 0.367 R
m
R
m
= Ultimate tensile strength at room temperature
PD8010
PD8010 Part 1
Hoop Stress S
h
< aeS
y
(OPE, SUS, OCC)
Equivalent Stress S
e
< 0.9S
y
(OPE, SUS, OCC)
Where:
S
y
= specified minimum yield strength
e = weld joint factor
PD8010 Part 1
2 2
2 2
( )
( )
o i
hl
o L
D D
S P
D D
( +
=
(
2 2 2
hl L hl L T
S +S -S *S +3*S
e
S =
S
hl
hoop stress using nominal dimensions
2 *
2
shear
T
F
MT
S
Z Area
(
(
= +
(
S
L
Based on restrained/unrestrained status
S
L
for unrestrained piping
L LP
S = S + im z
S
L
for restrained piping
If FAC = 1.0 (fully restrained pipe)
FAC | E o dT - uS
HOOP
| + S
HOOP
< 0.9 (Syield) (OPE)
If FAC = 0.001 (buried, but soil restraints modeled)
Fax/A - v S
HOOP
+ Sb + S
HOOP
< 0.9 (Syield) (OPE)
(If Slp + Fax/A is compressive)
If FAC = 0.0 (fully above ground)
Slp + Fax/A + Sb + S
HOOP
< 0.9 (Syield) (OPE)
CAESAR II Quick Reference Guide 26
PD8010 Part 1
(If Slp + Fax/A is compressive)
(Slp + Sb + Fax/A) (1.0 - FAC) < 0.75) (0.72) (Syield) (SUS)
sqrt ( Sb
2
+ 4 St
2
) < 0.72 (Syield) (EXP)
(Slp + Sb + Fax/A) (1.0 - FAC) < 0.8 (Syield) (OCC)
PD8010 Part 2
Hoop Stress S
h
< f
dh
S
y
Equivalent Stress S
e
< f
de
S
y
Where:
S
y
specified minimum yield strength
f
dh
hoop stress design factor (See Table 2)
f
de
equivalent stress design factor (See Table 2)
2 2
2 2
( )
( )
( )
o L
i o
o L
D D
Sh P P
D D
+
=
PD8010 Part 2
2 2 2
e h L h L T
S = S +S -S *S +3*S
2 *
2
shear
T
F
MT
S
Z Area
(
(
= +
(
L LP
S = S + im z
RCC-M C & D
Slp + 0.75i Ma/Z < Sh (SUS)
iMc/Z < f (1.25 Sc + .25 Sh) + Sh - Sl (EXP)
Slpmax + 0.75i (Ma + Mb)/Z < 1.2 Sh (OCC)
Stoomwezen
Slp + 0.75i Ma/Z < f (SUS)
iMc/Z < fe (EXP)
Slp + 0.75i (Ma + Mb)/Z < 1.2f (OCC)
27 CAESAR II Quick Reference Guide
UKOOA
oa
b
(f
2
/r) + PD
m
/ (4t) < (f
1
f
2
LTHS) / 2.0
Where:
P = design pressure
D
m
= pipe mean diameter
t = pipe wall thickness
f
1
= factor of safety for 97.5% lower confidence limit, usually 0.85
f
2
= system factory of safety, usually 0.67
oa
b
= axial bending stress due to mechanical loads
r = oa(0:1) /oa(2:1)
oa(0:1) = long term axial tensile strength in absence of pressure load
oa(2:1) = long term axial tensile strength in under only pressure loading
LTHS = long term hydrostatic strength (hoop stress allowable)
CAESAR II Quick Reference Guide 28
Node Locations on Bends
Bends are defined by the element entering the bend and the
element leaving the bend. The actual bend curvature is always
physically at the TO end of the element entering the bend.
The element leaving a bend must appear immediately after the
element defining (entering) the bend.
The default bend radius is 1.5 times the pipe nominal OD.
For stress and displacement output the TO node of the element
entering the bend is located geometrically at the FAR point on the
bend. The FAR point is at the weld line of the bend, and adjacent to
the straight element leaving the bend.
The NEAR point on the bend is at the weld line of the bend, and
adjacent to the straight element entering the bend.
The FROM point on the element is located at the NEAR point of the
bend if the total length of the element as specified in the DX, DY and
DZ fields is equal to: Radius * tan( Beta / 2 ) where Beta is the
bend angle, and Radius is the bend radius of curvature to the bend
centerline.
Nodes defined in the Angle # and Node # fields are placed at the
given angle on the bend curvature. The angle starts with zero
degrees at the NEAR point on the bend and goes to Beta degrees
at the FAR point of the bend.
Angles are always entered in degrees.
By default, nodes on the bend curvature cannot be specified within
five (5) degrees of one another or within five degrees of the nearest
end point. This and other bend settings may be changed through
the Main Menu, Configure-setup processor.
When the FROM node on the element entering the bend is not at
the bend NEAR point a node may be placed at the near point of the
bend by entering an Angle # on the bend spreadsheet equal to 0.0
degrees. For more information see the following figure.
When defining a bend element for the first time in the pipe
spreadsheet, nodes are automatically placed at the near and mid
point of the bend. The generated midpoint node number is one less
than the TO node number on the element, and the generated near
point node number is two less than the TO node number on the
element. A near point should always be included in the model in
29 CAESAR II Quick Reference Guide
tight, highly formed piping systems. The top-left figure below shows
the points on the bend as they would be input. The top-right figure
shows the actual geometric location of the points on the bend. The
bottom-left figure shows the same geometry except that two nodes
are defined on the bend curvature at angles of zero and forty-five
degrees.
For an animated tutorial on modeling bends, select the ANIMATED
TUTORIALS option on the Help menu.
CAESAR II Quick Reference Guide 30
CAESAR II Verification and Validation Manual
The CAESAR II Verification and Validation Manual is intended to serve as a
publicly available verification document. This manual discusses (briefly)
the current industry QA standards, the COADE QA standard, a series of
benchmark jobs, and instructions for users implementing QA
procedures on their own hardware.
The benchmark jobs consist of comparisons to published data by ASME
and the NRC. Additional test jobs compare CAESAR II results to other
industry programs.
For additional information on the Verification and Validation Manual, please
contact the sales department at [email protected].
31 CAESAR II Quick Reference Guide
Additional COADE Software Programs
CADWorx Plant - An AutoCAD based plant design/drafting program with a
bi-directional data transfer link to CAESAR II. CADWorx allows models to
be created in ortho, iso, 2D or 3D modes. CADWorx template
specifications, contained with built in auto routing, auto iso, stress iso,
auto dimensioning, complete libraries, center of gravity calculations, and
bill of materials, provides the most complete plant design package to
designers.
CodeCalc - A program for the design or analysis of pressure vessel
components. CodeCalc capabilities include: analysis of tubesheets,
rectangular vessels, flanges, nozzles, Zick Analysis, and the standard
internal/external thickness and pressure computations on heads, shells,
and cones. API 579 calculations are also included.
PV Elite - A comprehensive program for the design or analysis of vertical
and horizontal vessels. Pressure Vessel Codes include ASME VIII-1
and VIII-2, PD:5500 and EN-13445. PVElite includes all of the CodeCalc
functionality.
TANK - A program for the design or rerating of API-650/653 storage
tanks. The program includes API 650 Appendices A, E, F, M, P, S, and
L as well as API 653 Appendix B. Computations address: winds girders,
conical roof design, allowed fluid heights, and remaining corrosion
allowance.
Quick Reference Guide Index
A
Additional COADE Software
Programs 31
ASME SECT III CLASS 2 & 3 15
B
B31.1 15
B31.1 (1967) and Navy Section 505
16
B31.11 19
B31.3 16
B31.4 16
B31.4 Chapter IX 16
B31.5 17
B31.8 17
B31.8 Chapter VIII 18
Bends 20
Branch Junctions 20
BS 7159 21
C
CAESAR II Interfaces 4
CAESAR II Intersection Types 14
CAESAR II Pipe Stress Seminars 3
CAESAR II Quality Assurance
Manual 30
CAESAR II Quick Reference Guide
Version 5.20 2
CAESAR II Software 2
Canadian Z662 22
Code Stresses 15
CODETI 22
D
Database Definitions 12
Det Norske Veritas (DNV) 22
E
EN-13480 23
F
FDBR 24
FRP Properties 11
G
GPTC/Z380 19
H
HPGSL 24
L
List of Materials 13
M
Miscellaneous Computations 12
N
Node Locations on Bends 28
Norwegian 24
P
PD8010 25
Piping Codes 5
Plot Colors 11
R
RCC-M C & D 26
Restraints 7
S
Setup File Directives List 8
SIFs and STRESSES 9
Stoomwezen 26
Stress 15
System Requirements 3
T
Troubleshooting 4
U
UKOOA 27
US Codes 15
COADE Inc.
12777 Jones Road, Suite 480
Houston, Texas 77070
Phone:(281)890-4566
Fax: (281)890-3301
Internet: www.coade.com
CAESAR II
Quick Reference Guide
VERSION 5.20
LAST REVISED 4/2009