0% found this document useful (0 votes)
37 views

Project: LRFD Aashto 1 Code: Structure Design

This document summarizes the design of a structural member. It includes: 1. Geometric properties and dimensions of the cross-section. 2. Material properties and design parameters. 3. Applied loads including axial force, bending moments, and shear forces. 4. Calculations to check member strength including axial compression, flexure, and shear. 5. A final check that the combined effects of all forces is less than the strength capacity.

Uploaded by

darulmustakim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views

Project: LRFD Aashto 1 Code: Structure Design

This document summarizes the design of a structural member. It includes: 1. Geometric properties and dimensions of the cross-section. 2. Material properties and design parameters. 3. Applied loads including axial force, bending moments, and shear forces. 4. Calculations to check member strength including axial compression, flexure, and shear. 5. A final check that the combined effects of all forces is less than the strength capacity.

Uploaded by

darulmustakim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

STRUCTURE DESIGN PROJECT :

A. Section Properties - Diameter - Pipe Thick - Area - Central of Y axis - Central of Z axis B. Section of modulus about Y axis Section of modulus about Z axis Plastic modulus about Y axis Plastic modulus about Z axis Inertia Moment of Y axis Inertia Moment of Z axis Radius of Giration (Y axis) Radius of Giration (Z axis) Buckling coefficient for Web
(D) (tw) (A) (Ybar) (Zbar) (Syy) (Szz) (Zyy) (Zzz) (Iyy) (Izz) (ry) (rz)

DATE : AUGUST ,2009 PAGE

1
= = = = = = = = = = = = = = 0.609 0.016 0.0298 0.3045 0.3045 0.0043 0.0043 0.0056 0.0056 0.001 0.001 0.210 0.210 5
m m m2 m2 m2

LRFD AASHTO CODE


z

t
m3 m3 m3 m3 m4 m4 m2 m2

(kw)

6.10.9.2

Design Parameter for Strength Evaluations Length of member Effective Length factor Material Properties Specified Minimun Yield Strength of Steel Modulus Elastisity of Steel Material Name Forces Actions on Mamber Axial Force Moment for y axis Moment for z axis Shear for y axis Shear for Z axis

(L) (K)

= =

0.50 1.00

4.6.2.5

C.

(Fy)

2 240000 kN/m

(Es) = (Name) = (Pu) (Muy) (Muz) (Vuy) (Vuz)

2E+08 kN/m2 43A

D.

= -0.2653 kN (Compression) = 150 kN m = 37.5 kN m = 300 kN = 75 kN

6.5.4.2

Resistance Factors for Axial Compression for Tension, fracture in net section for Tension, yielding in gross section for Flexure for Shear Check Axial Strength

(c) (u) (y) (f) (v)

= = = = =

0.9 0.8 0.95 1 1

F.

1 Check Slendernesss ratio of axial compressions mamber

6.9.3

l = r

2.38

<

200

O.K !!!

2 Axial Tensile Strength (u Pn)

u Pn =

u Fy A

5723.0

3 Ratio of Axial Strength

Pu = C Pn
G

6.8.4 4.6E-05

<

1.0

O.K !!!

Check Flexural Strength 1 Check for Local Buckling Resistance

2
8 .8

E Fy
E Fy

57.74

254.03

D t

38.063

2 Moment Plastis (Mp)

M p = Fy.Zy
3 Moment Plastis (Mp)

1350

kN m

My = Fy.Sy

1033

kN m

if ,

D E ; Mn = M p <2 t Fy D E E ; Mn = My < 8 .8 Fy t Fy
D t
E Fy

6.12.2.2.3-1

if ,2

6.12.2.2.3-2

E Fy

8 .8

57.74

>

38

<

254.03 fMn = 1350 kN m

Nominal Flexural strength resistance

Muy f Mn
Mux f Mn

0.11108

< 1.0

O.K !!!

0.02777

< 1.0

O.K !!!

H.

Nominal Shear Strength 1 Nominal Shear Strength

Vn =

CVp
Vp = 4149.2 kN

6.10.9.2 - 1 6.10.9.2.-2

Vp = 0 . 58 Fy As

2 Ratio of shear buckling resistance

if;

D Ek 1.12 t Fy

than

6.10.9.3.2-4

if;

1.12

Ek D Ek < < 1. 4 Fy t Fy

Than C

1.12 Ek D Fy t
< 1 .4 Ek Fy
Ek Fy

1.899

6.10.9.3.2-5

if;

D t

Than C =

1 . 57 D t
2

0.070

6.10.9.3.2-6

1.12

Ek Fy
72

D t

1 .4
90

Ek Fy

> 38 <

Use ; Nominal shear Strength in Local y 3 Ratio of Shear Strength

= =

1 4149.2 kN

V CVn

Vuy V CVn
= 0.07230

< <

O.K. !!! O.K. !!!

V uz V CV
H.

=
n

0.01808

Check Ratio of Combine Strength

Pu U Pn
if

0.000

Pu U Pn

0.2

6.9.2.2-1

Muy Pu Muz + + 2U Pn f Mny f Mnz

0.1389

if

Pu C Pn

0.2 6.9.2.2-2

Pu Muz 8 Muy + + 2U Pn 9 f Mny f Mnz


Pu U Pn
Use

0.1234

0.0000

< 0.2

Muy Pu Muz + + 2U Pn f Mny f Mnz


0.1389

<

O.K. !!!