Electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician in accordance with current IEE reguations. This product is IPX4 rated and suitable for installation in zone 2 and outside Zones. Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are no hidden cables or pipes in the wall.

Uploaded by

Qtx Mark
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views2 pages

Atomic Cabinet 42700 Fixing Instructions PDF

Electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician in accordance with current IEE reguations. This product is IPX4 rated and suitable for installation in zone 2 and outside Zones. Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are no hidden cables or pipes in the wall.

Uploaded by

Qtx Mark
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Figure 1

60cm
75cm

60cm
zone

60cm
zone outside zone

60cm
75cm
2

zone

zone

zone

zone

225cm

60cm radius

zone

zone

electron Art no. 42600

All installations must comply with guidelines which are based on a zonal concept. The diagram to the left illustrates this concept and must be followed to ensure the safe installation of bathroom lighting. These regulations apply to domestic installations only. Installations must be made in accordance with the current IEE wiring regulations and relevant building regulations. HiB recommends that all electrical bathroom products should only be tted by a suitably qualied, Part P registered electrician. This product is IPX4 rated and suitable for installation in Zone 2 and Outside Zones.

Quality Bathroom Products


Aluminium Cabinets - Fixing Instructions
Thank you for purchasing this HiB product. Please read through these instructions carefully and refer back to them during installation to ensure that your product is tted safely and that it retains its high quality nish. Please retain this leaet for future reference.

75cm

75cm

225cm

Electrical Safety Information


HiB recommends that all electrical bathroom products should only be tted by a suitably qualied, Part P registered electrician in accordance with current IEE reguations. Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are no hidden cables or pipes in the wall.

Figure 2

Wiring Diagram

Live supply is Brown Earth supply is Green and Yellow Neutral supply is Blue

live earth neutral

Live supply can be Red or Brown Earth supply is Green and Yellow Neutral supply can be Blue or Black

LUMINAIRE

MAINS SUPPLY

Care Instructions
To preserve the high quality nish of your HiB product, please ensure you regard the following care and cleaning recommendations:
wipe off all water spillages as soon as possible mirrors and glass can be cleaned with a proprietary cleaner using a soft cloth, taking care not to get excessive cleaner behind the mirror all other surfaces should be cleaned with diluted detergent, i.e. washing up liquid, and a soft cloth scourers and scouring agents should not be used, as these may cause damage to the surface of the product

HiB Ltd, Castle House, 21-23 Station Road, New Barnet, Herts, EN5 1PH

t. 020 8441 0352 f. 020 8441 0219 e. [email protected] w. www.hib.co.uk

HiB Copyright: No part of this document may be reprinted or duplicated without HiB consent. All sizes and measurements are approximate, but we do try and make sure they are as accurate as possible. In the interest of continuous product development, HiB reserves the right to alter specications as necessary. E & OE.

atomic Art no. 42700

attaching light tting

xing preparation

wall mounting

door adjustment

shelf assembly

1) Attach the LED light tting on the top of the cabinet using the pre-drilled holes and the screws provided. Push the male and female electrical connections together until they click. 2) Position the cabinet in a suitable location, (according to Figure 1 on the back page), ensuring that the domestic electrical mains supply is within reach of the electrical connection point of the cabinet. Carefully mark the position of the top of the cabinet using a soft pencil. 3) Remove the cabinet from the wall and using a spirit level, mark a horizontal line 50mm below the original pencil mark. Hold

the mounting bracket in place with the holes corresponding with the marked line. Ensure the bracket is central, and mark the position of the holes. 4) Before drilling, ensure there are no hidden cables or pipes behind the mounting points. Drill the required holes in the marked positions. If drilling through tile, use a ceramic drill bit. Insert the wall plugs level with the surface of the wall. If tting to a tiled surface, wall plugs should be inserted below the tile surface to avoid cracking. NB. For plasterboard walls, specialist xings should be purchased, available from any DIY or hardware store. Fix the bracket to the wall using the screws provided.

5) Temporarily hang the cabinet on the top bracket, and position the bottom mounting bracket into the slot underneath the cabinet. Mark the position of the bracket using a soft pencil, then remove the cabinet from the wall. 6) Place the bottom bracket on the previously marked line and mark the positions of the holes. Using the same method as before, drill the required holes and attach the bracket to the wall using the screws provided. 7) This cabinet is provided with an electrical supply cable already tted. This cable should be connected to the household

electrical circuit, and connections should be made in accordance with the latest IEE regulations. This is a Class I product and must be connected to Earth. Ensure the domestic electrical mains supply to which the product is being connected is turned off. Connect the domestic mains supply according to Figure 2 on the back page. 8) Hang the cabinet on the wall ensuring that it is rmly located on both brackets. Align doors according to the diagram above. 9) Starting with the top shelf, insert the shelf supports in the desired position and t the shelf.