100% found this document useful (1 vote)
523 views

Schemes Talcher

This document contains a table of contents listing 85 graphics printouts related to the functional design of Talcher Super Thermal Power Plant Stage-II. The printouts cover systems like flue gas, air, fans, fuel, feedwater, condensate, cooling water, and dosing. They provide schematic diagrams of components and subsystems in the power plant such as boilers, pumps, heat exchangers, tanks, and piping arrangements.

Uploaded by

Sam
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
523 views

Schemes Talcher

This document contains a table of contents listing 85 graphics printouts related to the functional design of Talcher Super Thermal Power Plant Stage-II. The printouts cover systems like flue gas, air, fans, fuel, feedwater, condensate, cooling water, and dosing. They provide schematic diagrams of components and subsystems in the power plant such as boilers, pumps, heat exchangers, tanks, and piping arrangements.

Uploaded by

Sam
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 206

TALCHER SUPER TPP STAGE-II (4 X 500 MW)

NTPC

SHT : 1

Graphic Printout

SECTION 06

GRAPHICS PRINTOUTS

Revision 0

FUNCTIONAL DESIGN SPECIFICATION


GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 2

Graphic Printout

TABLE OF CONTENTS
Air & Flue Gas Overview ...............................................................................................9
Flue Gas System 1(Furnace To AHS) .......................................................................10
Flue Gas System 2(RAPHs I/L to Chimney)............................................................11
Flue Gas System 3(ECO-to-AH O/L)........................................................................12
FD Fan Overview..........................................................................................................13
FD Fan - A ....................................................................................................................14
FD Fan - B ....................................................................................................................15
Air (Pri & Sec) Overview .............................................................................................16
PA Fan A.......................................................................................................................17
PA Fan B.......................................................................................................................18
ID Fan Overview...........................................................................................................19
ID Fan A .......................................................................................................................20
ID Fan B........................................................................................................................21
Primary Air System.......................................................................................................22
Primary Air Heaters ......................................................................................................23
Primary Air Heater - A .................................................................................................24
Primary Air Heater - B..................................................................................................25
Secondary Air ...............................................................................................................26
Secondary Air Heaters ..................................................................................................27
Secondary Air Heater - A .............................................................................................28
Scaph & Scaph Drain Tank Level Overview................................................................30
Condensate Overview ...................................................................................................31
Condenser .....................................................................................................................32
DM/CST Scheme ..........................................................................................................33
Condensate Extraction Pump........................................................................................34
Condensate Extraction Pump - A..................................................................................35
Condensate Extraction Pump - B..................................................................................36
Condensate Extraction Pump - C..................................................................................37
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 3

Graphic Printout

GSC & Drain Cooler.....................................................................................................38


LP Heaters 1,2,3(Condensate ,Extraction & Drn) ........................................................39
LP Heater - 1.................................................................................................................40
LP Heater - 2.................................................................................................................41
LP Heater - 3.................................................................................................................42
Deaerator.......................................................................................................................43
CW System Unit # 3 & Unit # 4 ...................................................................................44
CWP 4A .....................................................................................................................45
CWP 4B .....................................................................................................................46
ECW/ACW System Overview......................................................................................47
ECW A,B,C (TG) Overview......................................................................................48
ECW A,B (SG) Overview..........................................................................................49
ACW A,B,C Overview ..............................................................................................50
Fuel Overview...............................................................................................................51
Fuel Oil Storage Circuit ................................................................................................52
Fuel Oil To Boiler.........................................................................................................53
Pulvariser A ..................................................................................................................54
Pulvariser B...................................................................................................................55
Pulvariser C...................................................................................................................56
Pulvariser D ..................................................................................................................57
Pulvariser E...................................................................................................................58
Pulvariser F ...................................................................................................................59
Pulvariser G ..................................................................................................................60
Pulvariser H ..................................................................................................................61
Pulvariser J....................................................................................................................62
Pulvariser K ..................................................................................................................63
Feed Water Overview ...................................................................................................64
Boiler Drum & Feed Water & BCW Pump ..................................................................65
Drum & BCW Pumps ...................................................................................................66
TDBFP A FW & Steam .............................................................................................67
TDBFP B FW & Steam .............................................................................................68
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 4

Graphic Printout

TDBFP A Lube Oil & Jacking Oil System................................................................69


TDBFP B Lube Oil & Jacking Oil System................................................................70
TDBFP A TSI ............................................................................................................71
TDBFP B TSI ............................................................................................................72
MDBFP C (Feed Water) ............................................................................................73
MDBFP C Lube Oil,Sealing & Cooloing Water System ..........................................74
FW TDBFP A Sealing & Cooling Water Lines.........................................................75
FW TDBFP B Sealing & Cooling Water Lines.........................................................76
HPH Economiser ..........................................................................................................77
HP Heater 5A & 6A......................................................................................................78
HP Heater 5B & 6B ......................................................................................................79
IBV - 1 ..........................................................................................................................80
IBV - 2 ..........................................................................................................................81
SWAS Sampling Points ................................................................................................82
LP Dosing (Ammonia)..................................................................................................83
LP Dosing (Hydrazine) .................................................................................................84
LP Dosing (Hydrazine & Ammonia)............................................................................85
Instrument Air SG Area-1..........................................................................................86
Instrument Air SG Area - 2........................................................................................87
Instrument Air - TG ......................................................................................................88
Service Air ....................................................................................................................89
Soot Blowing Scheme...................................................................................................90
Drum Metal Temperature .............................................................................................91
RH O/L Hdr Tube Metal Temperatures........................................................................92
Panellete SH OL Hdr S-32 Metal Temperatures ..........................................................93
Platen SH O/L Hdr S-36 Assy Metal Temperatures.....................................................94
LT SH O/L Hdr Metal Temperatures............................................................................95
Steam Overview............................................................................................................96
SH Steam System (TO HPT) ........................................................................................97
SH Steam with SH Spray..............................................................................................98
SH System With Vents & Drains..................................................................................99
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 5

Graphic Printout

RH Steam (To IPT).....................................................................................................100


RH System With RH Spray ........................................................................................101
RH Steam With Drains & Vents.................................................................................102
HP/LP Bypass .............................................................................................................103
Auxiliary Steam Scheme.............................................................................................104
Extraction Steam.........................................................................................................105
Blow Down Scheme CBD & IBD ...........................................................................106
Steam Drains (HP DFT & LP DFT) ........................................................................107
Steam Drain (SDFT & UFT) ......................................................................................108
TG Overview ..............................................................................................................109
Turbine Lube Oil Scheme...........................................................................................110
Turbine Lube Oil Scheme...........................................................................................111
Unit Overview.............................................................................................................112
Unit Overview - A ......................................................................................................113
Generator And 400 KV System ..................................................................................115
11KV Unit SWBD 4UA (Part) ................................................................................116
11KV SWBC 4UA(Part),4UB(Part) and 11KV SWBD - SC..................................117
11KV Unit SWBD 4UB(Part) .................................................................................118
415VSWBD-USS#4,TGMCC#4,ueS#4,DG#5& STDBY DG#6 ..............................119
415 SWBD USS # 4,MILL # 4.BLR ACDB # 4 ....................................................120
3.3 KV SWDB 4UAA & 415V S/S SWGR #4 ..........................................................121
415V ESP BD # 4A & 4B...........................................................................................122
415V ESP BD # 4C & 4D...........................................................................................123
AIR HTR FG O/L TEMP CONTROL........................................................................125
AIR FLOW CONTROL .............................................................................................126
AMMONIA HYDRAZINE DOZING CONTROL .................................................127
BURNER TILT CONTROL.......................................................................................128
CBD TANK LEVEL CONTROL...............................................................................129
CEP RECIRCULATION CONTROL ........................................................................130
COORDINATED MASTER CONTROL...................................................................131
DEAERATOR LEVEL CONTROL...........................................................................132
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 6

Graphic Printout

DEAERATOR PRESSURE CONTROL....................................................................133


DRUM LEVEL (SINGLE ELEMENT)/FEED WTR DP CTRL ...............................134
DRUM LEVEL (THREE ELEMENT)/FW DP CTRL ..............................................135
DRUM LEVEL\FW TRANSMITTR SELECTION ..................................................136
ECW DP CONTROL..................................................................................................137
FUEL FLOW CONTROL ..........................................................................................138
FURNACE DRAFT CONTROL................................................................................139
GLAND SEAL WATER PRESSURE CONTROL....................................................140
GSC MIN FLOW CONTROL....................................................................................141
HOTWELL LEVEL CONTROL................................................................................142
HPH 5A/6A LEVEL CONTROL ...............................................................................143
HPH 5B/6B LEVEL CONTROL................................................................................144
LP HEATER ...............................................................................................................145
MILL A AIR FLOW /O/L TEMP/FEEDER A CTRL ...............................................146
MILL B AIR FLOW/O/L TEMP/FEEDER B CTRL.................................................147
MILL C AIR FLOW/O/L TEMP/FEEDER C CTRL.................................................148
MILL D AIR FLOW/O/L TEMP/FEEDER D CTRL ................................................149
MILL E AIR FLOW\O\L TEMP \FEEDER E CTRL ................................................150
MILL F AIR FLOW \O\L TEMP\FEEDER F CTRL ................................................151
MILL G AIR FLOW\O\L TEMP\FEEDER G CTRL ................................................152
MILL H AIR FLOW\O\L TEMP\FEEDER H CTRL ................................................153
MILL K AIR FLOW\O\L TEMP\FEEDER K CTRL ................................................154
PA HDR PRESSURE CONTROL .............................................................................155
PRAPH COLD END TEMP CONTROL ...................................................................156
RH STEAM TEMP CONTROL.................................................................................157
SCAPH DRAIN TANK LEVEL CONTROL ............................................................158
SH STEAM TEMP CONTROL .................................................................................159
SRAPH COLD END TEMP CONTROL ...................................................................160
CONTROL LOOP STATUS ......................................................................................161
TD BFP-A...................................................................................................................163
TD BFP-B ...................................................................................................................164
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 7

Graphic Printout

MD BFP ......................................................................................................................165
LOAD VS OXYGEN DESIGN COAL......................................................................166
FUEL FLOW VS LOAD ............................................................................................167
FUEL FLOW VS LOAD ............................................................................................168
COAL CONSUMPTION VS LOAD..........................................................................169
TOTAL AIR FLOW VS LOAD .................................................................................171
BURNER TILT VS LOAD DESIGN COAL.............................................................172
BURNER TILT VS LOAD WORST COAL..............................................................173
SHO PRESSURE VS LOAD......................................................................................174
REACTIVE CAPABILITY CURVE .........................................................................175
STEAM TEMP AFTER DESH VS LOAD ................................................................176
STEAM TEMP AFTER DESH VS LOAD ................................................................177
STEAM TEMP AFTER DESH VS LOAD ................................................................178
STEAM TEMP AFTER DESH VS LOAD ................................................................179
SH STEAM TEMP VS LOAD ...................................................................................180
SH STEAM TEMPERATURE VS LOAD.................................................................181
RH STEAM TEMP VS LOAD...................................................................................182
RH STEAM TEMP VS LOAD...................................................................................183
SH/RH SPRAY VS LOAD DESIGN COAL .............................................................184
RH SPRAY VS LOAD DESIGN COAL ...................................................................185
SHO STEAM FLOW VS LOAD ...............................................................................186
SH/RH SPRAY VS LOAD WORST COAL..............................................................187
SH/RH SPRAY VS LOAD WORST COAL..............................................................188
AIR FLOW VS COAL FLOW IN MILL - A.............................................................189
AIR FLOW VS COAL FLOW IN MILL-K...............................................................190
PERFORMANCE CURVE FOR FD FAN - A ..........................................................191
PERFORMANCE CURVE FOR FD FAN - B ..........................................................192
PERFORMANCE CURVE FOR PA FAN - A ..........................................................193
PERFORMANCE CURVE FOR PA FAN - B ..........................................................194
AIR FLOW VS COAL FLOW IN MILL - B .............................................................195
AIR FLOW VS COAL FLOW IN MILL - C .............................................................196
FUNCTIONAL DESIGN SPECIFICATION
GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


NTPC

SHT : 8

Graphic Printout

AIR FLOW VS COAL FLOW IN MILL-D...............................................................197


AIR FLOW VS COAL FLOW IN MILL-E ...............................................................198
AIR FLOW VS COAL FLOW IN MILL -F ..............................................................199
AIR FLOW VS COAL FLOW IN MILL-G...............................................................200
AIR FLOW VS COAL FLOW IN MILL - H.............................................................201
AIR FLOW VS COAL FLOW IN MILL - J ..............................................................202
PA HDR PRESSURE VS LOAD ...............................................................................203
BOILER EFFICIENCY VS LOAD............................................................................204
RH STEAM PRESSURE VS LOAD(LHS) ...............................................................205
RH STEAM PRESSURE VS LOAD (RHS) ..............................................................206

FUNCTIONAL DESIGN SPECIFICATION


GRAPHICS (Printouts)

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 9

NTPC
Graphic Printout

Air & Flue Gas Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 10

NTPC
Graphic Printout

Flue Gas System 1(Furnace To AHS)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 11

NTPC
Graphic Printout

Flue Gas System 2(RAPHs I/L to Chimney)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 12

NTPC
Graphic Printout

Flue Gas System 3(ECO-to-AH O/L)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 13

NTPC
Graphic Printout

FD Fan Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 14

NTPC
Graphic Printout

FD Fan - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 15

NTPC
Graphic Printout

FD Fan - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 16

NTPC
Graphic Printout

Air (Pri & Sec) Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 17

NTPC
Graphic Printout

PA Fan A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 18

NTPC
Graphic Printout

PA Fan B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 19

NTPC
Graphic Printout

ID Fan Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 20

NTPC
Graphic Printout

ID Fan A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 21

NTPC
Graphic Printout

ID Fan B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 22

NTPC
Graphic Printout

Primary Air System

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 23

NTPC
Graphic Printout

Primary Air Heaters

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 24

NTPC
Graphic Printout

Primary Air Heater - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 25

NTPC
Graphic Printout

Primary Air Heater - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 26

NTPC
Graphic Printout

Secondary Air

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 27

NTPC
Graphic Printout

Secondary Air Heaters

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 28

NTPC
Graphic Printout

Secondary Air Heater - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 29

NTPC
Graphic Printout

Secondary Air Heater - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 30

NTPC
Graphic Printout

Scaph & Scaph Drain Tank Level Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 31

NTPC
Graphic Printout

Condensate Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 32

NTPC
Graphic Printout

Condenser

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 33

NTPC
Graphic Printout

DM/CST Scheme

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 34

NTPC
Graphic Printout

Condensate Extraction Pump

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 35

NTPC
Graphic Printout

Condensate Extraction Pump - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 36

NTPC
Graphic Printout

Condensate Extraction Pump - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 37

NTPC
Graphic Printout

Condensate Extraction Pump - C

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 38

NTPC
Graphic Printout

GSC & Drain Cooler

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 39

NTPC
Graphic Printout

LP Heaters 1,2,3(Condensate ,Extraction & Drn)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 40

NTPC
Graphic Printout

LP Heater - 1

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 41

NTPC
Graphic Printout

LP Heater - 2

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 42

NTPC
Graphic Printout

LP Heater - 3

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 43

NTPC
Graphic Printout

Deaerator

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 44

NTPC
Graphic Printout

CW System Unit # 3 & Unit # 4

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 45

NTPC
Graphic Printout

CWP 4A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 46

NTPC
Graphic Printout

CWP 4B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 47

NTPC
Graphic Printout

ECW/ACW System Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 48

NTPC
Graphic Printout

ECW A,B,C (TG) Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 49

NTPC
Graphic Printout

ECW A,B (SG) Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 50

NTPC
Graphic Printout

ACW A,B,C Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 51

NTPC
Graphic Printout

Fuel Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 52

NTPC
Graphic Printout

Fuel Oil Storage Circuit

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 53

NTPC
Graphic Printout

Fuel Oil To Boiler

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 54

NTPC
Graphic Printout

Pulvariser A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 55

NTPC
Graphic Printout

Pulvariser B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 56

NTPC
Graphic Printout

Pulvariser C

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 57

NTPC
Graphic Printout

Pulvariser D

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 58

NTPC
Graphic Printout

Pulvariser E

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 59

NTPC
Graphic Printout

Pulvariser F

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 60

NTPC
Graphic Printout

Pulvariser G

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 61

NTPC
Graphic Printout

Pulvariser H

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 62

NTPC
Graphic Printout

Pulvariser J

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 63

NTPC
Graphic Printout

Pulvariser K

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 64

NTPC
Graphic Printout

Feed Water Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 65

NTPC
Graphic Printout

Boiler Drum & Feed Water & BCW Pump

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 66

NTPC
Graphic Printout

Drum & BCW Pumps

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 67

NTPC
Graphic Printout

TDBFP A FW & Steam

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 68

NTPC
Graphic Printout

TDBFP B FW & Steam

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 69

NTPC
Graphic Printout

TDBFP A Lube Oil & Jacking Oil System

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 70

NTPC
Graphic Printout

TDBFP B Lube Oil & Jacking Oil System

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 71

NTPC
Graphic Printout

TDBFP A TSI

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 72

NTPC
Graphic Printout

TDBFP B TSI

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 73

NTPC
Graphic Printout

MDBFP C (Feed Water)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 74

NTPC
Graphic Printout

MDBFP C Lube Oil,Sealing & Cooloing Water System

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 75

NTPC
Graphic Printout

FW TDBFP A Sealing & Cooling Water Lines

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 76

NTPC
Graphic Printout

FW TDBFP B Sealing & Cooling Water Lines


B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 77

NTPC
Graphic Printout

HPH Economiser

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 78

NTPC
Graphic Printout

HP Heater 5A & 6A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 79

NTPC
Graphic Printout

HP Heater 5B & 6B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 80

NTPC
Graphic Printout

IBV - 1

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 81

NTPC
Graphic Printout

IBV - 2

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 82

NTPC
Graphic Printout

SWAS Sampling Points

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 83

NTPC
Graphic Printout

LP Dosing (Ammonia)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 84

NTPC
Graphic Printout

LP Dosing (Hydrazine)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 85

NTPC
Graphic Printout

LP Dosing (Hydrazine & Ammonia)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 86

NTPC
Graphic Printout

Instrument Air SG Area-1

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 87

NTPC
Graphic Printout

Instrument Air SG Area - 2

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 88

NTPC
Graphic Printout

Instrument Air - TG

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 89

NTPC
Graphic Printout

Service Air

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 90

NTPC
Graphic Printout

Soot Blowing Scheme

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 91

NTPC
Graphic Printout

Drum Metal Temperature

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 92

NTPC
Graphic Printout

RH O/L Hdr Tube Metal Temperatures

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 93

NTPC
Graphic Printout

Panellete SH OL Hdr S-32 Metal Temperatures

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 94

NTPC
Graphic Printout

Platen SH O/L Hdr S-36 Assy Metal Temperatures

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 95

NTPC
Graphic Printout

LT SH O/L Hdr Metal Temperatures

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 96

NTPC
Graphic Printout

Steam Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 97

NTPC
Graphic Printout

SH Steam System (TO HPT)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 98

NTPC
Graphic Printout

SH Steam with SH Spray

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 99

NTPC
Graphic Printout

SH System With Vents & Drains

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
100

NTPC
Graphic Printout

RH Steam (To IPT)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
101

NTPC
Graphic Printout

RH System With RH Spray

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
102

NTPC
Graphic Printout

RH Steam With Drains & Vents

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
103

NTPC
Graphic Printout

HP/LP Bypass

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
104

NTPC
Graphic Printout

Auxiliary Steam Scheme

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
105

NTPC
Graphic Printout

Extraction Steam

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
106

NTPC
Graphic Printout

Blow Down Scheme CBD & IBD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
107

NTPC
Graphic Printout

Steam Drains (HP DFT & LP DFT)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
108

NTPC
Graphic Printout

Steam Drain (SDFT & UFT)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
109

NTPC
Graphic Printout

TG Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
110

NTPC
Graphic Printout

Turbine Lube Oil Scheme

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
111

NTPC
Graphic Printout

Turbine Lube Oil Scheme

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
112

NTPC
Graphic Printout

Unit Overview

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT :
113

NTPC
Graphic Printout

Unit Overview - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 114

NTPC
Graphics BMP

GRAPHICS FOR ELECTRICAL SYSTEM


Revision 0

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 115

NTPC
Graphics BMP

Generator And 400 KV System

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 116

NTPC
Graphics BMP

11KV Unit SWBD 4UA (Part)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 117

NTPC
Graphics BMP

11KV SWBC 4UA(Part),4UB(Part) and 11KV SWBD - SC

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 118

NTPC
Graphics BMP

11KV Unit SWBD 4UB(Part)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 119

NTPC
Graphics BMP

415VSWBD-USS#4,TGMCC#4,ueS#4,DG#5& STDBY DG#6

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 120

NTPC
Graphics BMP

415 SWBD USS # 4,MILL # 4.BLR ACDB # 4

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 121

NTPC
Graphics BMP

3.3 KV SWDB 4UAA & 415V S/S SWGR #4

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 122

NTPC
Graphics BMP

415V ESP BD # 4A & 4B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 123

NTPC
Graphics BMP

415V ESP BD # 4C & 4D

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 124

NTPC
Graphics BMP

GRAPHICS FOR CLCS


Revision0.0

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 125

NTPC
Graphics BMP

AIR HTR FG O/L TEMP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 126

NTPC
Graphics BMP

AIR FLOW CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 127

NTPC
Graphics BMP

AMMONIA HYDRAZINE DOZING CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 128

NTPC
Graphics BMP

BURNER TILT CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 129

NTPC
Graphics BMP

CBD TANK LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 130

NTPC
Graphics BMP

CEP RECIRCULATION CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 131

NTPC
Graphics BMP

COORDINATED MASTER CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 132

NTPC
Graphics BMP

DEAERATOR LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 133

NTPC
Graphics BMP

DEAERATOR PRESSURE CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 134

NTPC
Graphics BMP

DRUM LEVEL (SINGLE ELEMENT)/FEED WTR DP CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 135

NTPC
Graphics BMP

DRUM LEVEL (THREE ELEMENT)/FW DP CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 136

NTPC
Graphics BMP

DRUM LEVEL\FW TRANSMITTR SELECTION

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 137

NTPC
Graphics BMP

ECW DP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 138

NTPC
Graphics BMP

FUEL FLOW CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 139

NTPC
Graphics BMP

FURNACE DRAFT CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 140

NTPC
Graphics BMP

GLAND SEAL WATER PRESSURE CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 141

NTPC
Graphics BMP

GSC MIN FLOW CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 142

NTPC
Graphics BMP

HOTWELL LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 143

NTPC
Graphics BMP

HPH 5A/6A LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 144

NTPC
Graphics BMP

HPH 5B/6B LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 145

NTPC
Graphics BMP

LP HEATER

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 146

NTPC
Graphics BMP

MILL A AIR FLOW /O/L TEMP/FEEDER A CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 147

NTPC
Graphics BMP

MILL B AIR FLOW/O/L TEMP/FEEDER B CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 148

NTPC
Graphics BMP

MILL C AIR FLOW/O/L TEMP/FEEDER C CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 149

NTPC
Graphics BMP

MILL D AIR FLOW/O/L TEMP/FEEDER D CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 150

NTPC
Graphics BMP

MILL E AIR FLOW\O\L TEMP \FEEDER E CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 151

NTPC
Graphics BMP

MILL F AIR FLOW \O\L TEMP\FEEDER F CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 152

NTPC
Graphics BMP

MILL G AIR FLOW\O\L TEMP\FEEDER G CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 153

NTPC
Graphics BMP

MILL H AIR FLOW\O\L TEMP\FEEDER H CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 154

NTPC
Graphics BMP

MILL K AIR FLOW\O\L TEMP\FEEDER K CTRL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 155

NTPC
Graphics BMP

PA HDR PRESSURE CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 156

NTPC
Graphics BMP

PRAPH COLD END TEMP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 157

NTPC
Graphics BMP

RH STEAM TEMP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 158

NTPC
Graphics BMP

SCAPH DRAIN TANK LEVEL CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 159

NTPC
Graphics BMP

SH STEAM TEMP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 160

NTPC
Graphics BMP

SRAPH COLD END TEMP CONTROL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 161

NTPC
Graphics BMP

CONTROL LOOP STATUS

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 162

NTPC
Graphics BMP

GRAPHICS FOR XY PLOT

Revision 0

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 163

NTPC
Graphics BMP

TD BFP-A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 164

NTPC
Graphics BMP

TD BFP-B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 165

NTPC
Graphics BMP

MD BFP

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 166

NTPC
Graphics BMP

LOAD VS OXYGEN DESIGN COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 167

NTPC
Graphics BMP

FUEL FLOW VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 168

NTPC
Graphics BMP

FUEL FLOW VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 169

NTPC
Graphics BMP

COAL CONSUMPTION VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 170

NTPC
Graphics BMP

TOTAL AIR FLOW VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 171

NTPC
Graphics BMP

TOTAL AIR FLOW VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 172

NTPC
Graphics BMP

BURNER TILT VS LOAD DESIGN COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 173

NTPC
Graphics BMP

BURNER TILT VS LOAD WORST COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 174

NTPC
Graphics BMP

SHO PRESSURE VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 175

NTPC
Graphics BMP

REACTIVE CAPABILITY CURVE

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 176

NTPC
Graphics BMP

STEAM TEMP AFTER DESH VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 177

NTPC
Graphics BMP

STEAM TEMP AFTER DESH VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 178

NTPC
Graphics BMP

STEAM TEMP AFTER DESH VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 179

NTPC
Graphics BMP

STEAM TEMP AFTER DESH VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 180

NTPC
Graphics BMP

SH STEAM TEMP VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 181

NTPC
Graphics BMP

SH STEAM TEMPERATURE VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 182

NTPC
Graphics BMP

RH STEAM TEMP VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 183

NTPC
Graphics BMP

RH STEAM TEMP VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 184

NTPC
Graphics BMP

SH/RH SPRAY VS LOAD DESIGN COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 185

NTPC
Graphics BMP

RH SPRAY VS LOAD DESIGN COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 186

NTPC
Graphics BMP

SHO STEAM FLOW VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 187

NTPC
Graphics BMP

SH/RH SPRAY VS LOAD WORST COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 188

NTPC
Graphics BMP

SH/RH SPRAY VS LOAD WORST COAL

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 189

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 190

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL-K

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 191

NTPC
Graphics BMP

PERFORMANCE CURVE FOR FD FAN - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 192

NTPC
Graphics BMP

PERFORMANCE CURVE FOR FD FAN - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 193

NTPC
Graphics BMP

PERFORMANCE CURVE FOR PA FAN - A

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 194

NTPC
Graphics BMP

PERFORMANCE CURVE FOR PA FAN - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 195

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL - B

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 196

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL - C

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 197

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL-D

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 198

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL-E

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 199

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL -F

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 200

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL-G

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 201

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL - H

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 202

NTPC
Graphics BMP

AIR FLOW VS COAL FLOW IN MILL - J

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 203

NTPC
Graphics BMP

PA HDR PRESSURE VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 204

NTPC
Graphics BMP

BOILER EFFICIENCY VS LOAD

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 205

NTPC
Graphics BMP

RH STEAM PRESSURE VS LOAD(LHS)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

TALCHER SUPER TPP STAGE-II (4 X 500 MW)


SHT : 206

NTPC
Graphics BMP

RH STEAM PRESSURE VS LOAD (RHS)

FUNCTIONAL DESIGN SPECIFICATION - GRAPHICS

DOC. No: DOT195-302-FDS-V3S6

Rev. No : 0

You might also like