Telog's hydrant pressure Recorder, the HPR-31, monitors water pressure within any water distribution system. The recorder measures water pressure at user programmable rates up to four samples per second with its internal pressure transducer. Data may be gathered via an RS-232 connector using a hand-held Palm DTU or a laptop.

Uploaded by

Brian McMorris
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
952 views

Fire Hydrant Pressure Logger - Telog

Telog's hydrant pressure Recorder, the HPR-31, monitors water pressure within any water distribution system. The recorder measures water pressure at user programmable rates up to four samples per second with its internal pressure transducer. Data may be gathered via an RS-232 connector using a hand-held Palm DTU or a laptop.

Uploaded by

Brian McMorris
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Hydrant Pressure Recorder Page 1 of 3

Telog Hydrant Pressure Recorder

z Installs on 2½" nozzle or


1/4" NPT
z Environmentally rugged
z 5 year battery life
z Stores 80,000 data values
z Windows software support
z Easy data collection
z Security cover available

PRESSURE RECORDER DETAILS Back to Pressure Test Products Index


Telog’s Hydrant Pressure Recorder, the HPR-31, monitors water pressure within any water
distribution system. The HPR-31 replaces costly, high maintenance chart recorders in
applications such as pressure complaints, valve performance, model validations, water
hammers and negative pressure investigations.

The simplicity of the compact, battery-powered HPR-31 enables you to put it to work within
minutes of unpacking. The HPR-31 attaches onto the 2.5 inch hose nozzle outlet of a common
fire hydrant. The rugged enclosure is low profile and an optional security cover is available.

Once installed, the HPR-31 measures water pressure at user programmable rates up to four
samples per second with its internal pressure transducer. You can determine how often such
data is summarized for reporting. The recorder computes any combination of minimum,
average and maximum pressure measurement at each interval according to your selection of
statistics and recording intervals.

Recorded data may be gathered via an RS-232 connector using a hand-held Palm DTU (Data
Transfer Unit) or a laptop. The DTU is especially convenient for gathering data from several
hydrant pressure recorders. At times when on-site data evaluation is required, a laptop and
Teloggers for Windows software, is all you need.

For units with Diffuser kits, click here

See below for specifications.

PURCHASE PRESSURE RECORDER

ITEM NUMBER DESCRIPTION PRICE


Hydrant Pressure Recorder 100 psi $890.00
QTY HPR-31-100
Hydrant Pressure Recorder 200 psi $890.00
QTY HPR-31-200
Hydrant Pressure Recorder 300 psi $890.00
QTY HPR-31-300
Data Transfer Unit for Downloading Data $CALL
QTY A-203 DTU

1
$150.00
HPR Lite Software

http://www.pollardwater.com/EMarket/Pages/Telog%20Hyd%20Press%20Record.asp 5/16/2006
Hydrant Pressure Recorder Page 2 of 3

QTY S-3PCL
Security Cover with Keys $45.00
QTY A-HSC
Computer Interface Cable Only $52.50
QTY C-21ATC
1 - Call PollardWater.com for details.
PRESSURE RECORDER SPECIFICATIONS

Input
Type Strain gauge, isolated pressure sensor
Range (psi) 100 200 300
Over Pressure (psi) 300 600 600
Burst Pressure (psi) 850 1000 1000
Resolution 0.025% of full scale, 12-bit
Accuracy +0.2% of full scale at constant temperature
Temperature Effect +0.01% of full scale per ºC
Recording
Sample rate Programmable from 4/sec up to 8 hours
Data interval Programmable from 1/sec up to 8 hours
Values saved Selectable min, avg & max per interval
Memory 128 Kbytes (~80,000 data values)
Interface
Type RS-232; 300 to 19.2 Kbaud
Connector Circular 4 pin watertight
Battery
Type Single AA Lithium (Saft LS 14500 C or equal)
Life 5 years typical
Support Software
S-3PCTelogers for Windows
S-3PCL Telogers for Windows Lite
Data Transfer Unit Palm Pilot with Telog support software
Environmental and Mechanical
Temperature
Operating -40° to 65° C
Storage -10° to 65°
Humidity 0-100% relative humidity
Enclosure NEMA 4x /IEC IP65
Size 12.70 cm diameter x 8.89 cm or 5" diameter x 3.5"
Thread* Hydrant mount: 2.50" NHT Standard
Internal mount: 1/4 NPT
Computer Requirements
For S-3 PC or S-3PCL IBM compatible computer with a 586/133 MHz or higher processor
running on Microsoft Windows 95/98/NT/2000, at least 32 MB of RAM, a hard disk with at
least 200 MB of free space and a pointing device.

http://www.pollardwater.com/EMarket/Pages/Telog%20Hyd%20Press%20Record.asp 5/16/2006
Hydrant Pressure Recorder Page 3 of 3

Checkout Service Request Info Request Quote Products What's New Links

In USA: 800-437-1146 Outside USA: 516-746-0842 Fax: 516-746-0852

Contact us via eMail at: [email protected]

200 Atlantic Avenue, New Hyde Park, NY 11040


© copyright 2006 Pollardwater.com

http://www.pollardwater.com/EMarket/Pages/Telog%20Hyd%20Press%20Record.asp 5/16/2006

You might also like