520l0344 (Danfoss PVG32)
520l0344 (Danfoss PVG32)
Revision History
Table of revisions
Date Jun 2010 Dec 2010 Nov 2011 Page 69 80 All Changed Code numbers changed New back cover Major update Rev GD GE HA
Literature Reference
2011 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group.
Frontpage: F301302, F301306, F301056, Drawing 157-195.
Safety in Application
General Information
Function
Dimensions
Hydraulic Systems
Order Specification
Accessories
Remote control units Electrical remote control units PVRE, PVRET PVREL PVRES Prof 1 Prof 1 CIP Hydraulic remote control unit PVRHH
Battery
E Motion detection sensors
A Main power supply B Emergency stop/man present switch C HMI/Joystick control D Movement detection sensors E Main controller F F PVG 32 control valve G Hydraulic deactivation
Hydraulic deactivation
P301 316
HMI / Joystick
Joystick neutral switch Control Signal
Failure Detection
Hydraulic deactivation
P301 317
WWarning It is the responsibility of the equipment manufacturer that the control system incorporated in the machine is declared as being in confirmity with the relevant machine directives.
10
520L0344 Rev HA Nov 2011
PVE 1 C
PVEH
PVE 2 C
PVEH
A B C D
Emergency stop / man present switch PVE Faultmonitoring signals Neutral signal detection. Hydraulic deactivation
System Control Logic e.g. PLUS+1 for signal monitoring and triggering signal for deactivation of the hydraulic system. WWarning It is the responsibility of the equipment manufacturer that the control system incorporated in the machine is declared as being in confirmity with the relevant machine directives.
AND
high=on low=o
11
PVE 1
PVEH-DI AMP supply connector 1(US) 2(UDC2) 3( ) 4(Error) PVEH-DI AMP connector 1(DI-A) 2(DI-B) 3( ) 4(UDC)
PVE 2
PVEH-DI AMP supply connector 1(US) 2(UDC2) 3( ) 4(Error) PVEH-DI AMP connector 1(DI-A) 2(DI-B) 3( ) 4(UDC)
System Control Logic e.g. PLUS+1 for signal monitoring and triggering signal for deactivation of the hydraulic system.
WWarning It is the responsibility of the equipment manufacturer that the control system incorporated in the machine is declared as being in confirmity with the relevant machine directives. Other non-electrical modules which can be used in connection with hydraulic deactivation at different levels. PVG32 Mainly used in system with fixed displacement pumps PVSK, commonly used in crane application - full flow dump PVPE, full flow dump for the PVG 120 PVG100 Alternative LS dump or pilot supply disconnect PVPP, pilot oil supply shut off External cartridge valve connecting LS Pressure to Tank External cartridge valve connecting main Pressure to Tank PVG120 Pump disconnect/block for variable pumps PVPX, LS dump to tank
12
520L0344 Rev HA Nov 2011
13
Flow
0 0 Pressure
PC setting
P101 166E
P101 965
Once the closed center valve is opened, the PC control senses the immediate drop in system pressure and increases pump flow by increasing the swashplate angle. The pump continues to increase flow until system pressure reaches the PC setting. If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain system pressure by reducing flow. The PC control continues to monitor system pressure and changes swashplate angle to match the output flow with the work function pressure requirements. If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum displacement. In this condition, actual system pressure depends on the actuator load. Each section includes control schematic diagrams, setting ranges, and response / recovery times for each control available. Response is the time (in milliseconds) for the pump to reach zero displacement when commanded by the control. Recovery is the time (in milliseconds) for the pump to reach full displacement when commanded by the control. Actual times can vary depending on application conditions. For additional system protection, install a relief valve in the pump outlet line Pressure compensated system characteristics Constant pressure and variable flow High pressure standby mode when flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requirements Typical applications for pressure compensated systems Constant force cylinders (bailers, compactors, refuse trucks) On/off fan drives Drill rigs Sweepers Trenchers
14
520L0344 Rev HA Nov 2011
Flow
Remote PC setting
0 0
Pressure
P101 966
The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot line is vented to reservoir, the pump maintains pressure at the load sense setting. When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled with a microprocessor control, can produce an infinite range of operating pressures between the low pressure standby setting and the PC setting. Each section includes control schematic diagrams, setting ranges, and response / recovery times for each control available. Response is the time (in milliseconds) for the pump to reach zero displacement when commanded by the control. Recovery is the time (in milliseconds) for the pump to reach full displacement when commanded by the control. Actual times can vary depending on application conditions. Size the external valve and plumbing for a pilot flow of 3.8 l/min [1 US gal/min]. For additional system protection, install a relief valve in the pump outlet line. Remote pressure compensated system characteristics Constant pressure and variable flow High or low pressure standby mode when flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requirements Typical applications for remote pressure compensated systems Modulating fan drives Anti-stall control with engine speed feedback Front wheel assist Road rollers Combine harvesters Wood chippers
520L0344 Rev HA Nov 2011
15
Flow
Pressure
P101 968E
PC setting
P101 967
Most load sensing systems use parallel, closed center, control valves with special porting that allows the highest work function pressure (LS signal) to feed back to the LS control. Margin pressure is the difference between system pressure and the LS signal pressure. The LS control monitors margin pressure to read system demand. A drop in margin pressure means the system needs more flow. A rise in margin pressure tells the LS control to decrease flow. LS control with bleed orifice The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control. Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use with control valves that do not internally bleed the LS signal to tank.
16
17
18
2 P 3
M PVP LS 8 9 12 7 B A 6 13
4+5 A
T 11 PVB 10
14
16
LS B
P LS A 17 15 A
T PVB P
19
18
20
V310106.A
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Pressure relief valve Pressure reduction valve for pilot oil supply Pressure gauge connection Plug, open centre Orifice, closed centre Pressure adjustment spool Plug, closed centre LS connection LS signal Shuttle valve
11. 12. 13. 14. 15. 16. 17. 18. 19. 20.
Main spool LS pressure limiting valve Shock and suction valve, PVLP Pressure compensator LS connection, port A LS connection, port B Suction valve, PVLA Load drop check valve Pilot oil supply for PVE Max. oil flow adjustment screws for ports A and B
19
20
21
Allows the float spool to be held in the float position after release of the mechanical handle. PVMF
PAF
(Standard assembly)
22
The spools are designed in such a way that the pump pressure is controlled by the spool travel. The main spool must be displaced until the pump pressure just exceeds the load pressure before the working function is applied. If the main spool is held in this position, the pump pressure will remain constant even if the load pressure changes giving a stable system. The use of pressure control spools, however, also means that the oil flow is load dependent the dead band is load dependent the pump pressure can exceed the load pressure by more than is usual. Due to these factors it is recommended that pressure control spools are only used when it is known for certain that problems with stability will arise or already have arisen.
23
With the special inlet unloader, system pressure peaks can be minimized. The degree of pressure peak reductions is dependent upon system design. Systems where the PVG valve stack is placed closed to the pump or systems with limited flexibility in regards to hoses etc. benefit from the fast inlet unloader.
24
Max. pressure
Oil flow rated (See characteristics page 31 - 36) Spool travel, standard Spool travel, float position Dead band, flow control spools Max. internal leakage at 100 bar [2175 psi] and 21 mm2/s [102 SUS] Oil temperature (inlet temperature) Ambient temperature
Operating range Min. viscosity Max. viscosity Filtration Max. contamination (See page 75) (ISO 4406) Oil consumtion in pilot oil pressure reduction valve Oil viscosity
1) With PVSI end plate. With PVS end plate max. 300 bar [4351 psi]. 2) For 130 l/min contact Product Application Engineering Sauer-Danfoss. 3) In open circuit systems with short P-hoses/tubes, attention should be paid to pressure peaks at flows >100 l/min. [26.4 US gal/min] . 4) For system with mid inlet PVPVM. 5) Intermittent pressure at max. 250,000 cycles of full PVG life time cycles, with PVSI end plate. The maximum intermittent pressure at max. 250,000 cycles stresses the need to confirm application duty cycle before proceeding with specification. For further information contact Product Application Engineering Sauer-Danfoss.
25
Neutral position 2.2 0.2 Nm [5.0 1.8 lbfin] 2.2 0.2 Nm [5.0 1.8 lbfin] 2.7 0.2 Nm [23.9 1.8 lbfin] No
Max. spool travel 2.8 0.2 Nm [6.3 1.8 lbfin] 2.8 0.2 Nm [6.3 1.8 lbfin] 7.1 0.2 Nm [62.8 1.8 lbfin] 26
for PVE please see 520L0553 catalog. PVM + PVMR Spool displacement from neutral position Spool displacement from any other position Spool displacement from neutral position Spool displacement into float position Spool displacement away from float position No 19.5 13.4 22.3 17 Nm [3.8 lbfin] 8.5 Nm [73.3 lbfin] 22 Nm [5.0 lbfin] 60 Nm [13.5 lbfin] 28 Nm [6.3 lbfin] 26
Regulation range
26
Signal current at rated voltage (PVEM) Input impedance in relation to 0.5 UDC Power consumption
Constant voltage
1) Hysteresis is indicated at rated voltage and f = 0.02 Hz for one cycle (one cycle = neutral ->full A -> full B
-> neutral.
27
Reaction time
Supply voltage Disconnected by means of neutral switch Disconnected by means of neutral switch Constant voltage Function max. rated min. max. Reaction time from max. spool rated travel to neutral position min. max. Reaction time from neutral rated position to max. spool travel min. max. Reaction time from max. spool rated travel to neutral position min. rated Reaction time from neutral position to max. spool travel PVEA Prop. fine s 0.500 0.320 0.250 0.550 0.400 0.300 0.500 0.320 0.250 0.250 0.200 0.150 2% PVEH Prop. high s 0.230 0.150 0.120 0.175 0.090 0.065 0.200 0.120 0.050 0.100 0.090 0.065 4% PVES Prop. super s 0.230 0.150 0.120 0.175 0.090 0.065 0.200 0.120 0.050 0.100 0.090 0.065 0%
Hysteresis is indicated at rated voltage and f = 0.02 Hz for one cycle (one cycle = neutral ->full A -> full B -> neutral.
28
Spool position
520L0344 Rev HA Nov 2011
Oil viscosity
Oil viscosity range min. max. 12 - 75 mm2/s [65 - 347 SUS] 4 mm2/s [39 SUS] 460 mm2/s [2128 SUS]
Oil temperature
Oil temperature Rec. range min. max. 30 - 60C [86 -140F] -30C [-22F] 90C [194F]
Ambient temperature
Ambient temperature range Rec. -30 +60C [-22 +140F]
29
30
Via an external relay the pin pos. 3 can be connected to a solenoid valve which will relieve the LS-signal to tank, e. g. PVPX. Other connections possible: a solenoid valve to relieve the pump oil flow a signal lamp, an alarm horn pump cut-out, etc.
31
V310 002.A
Hydraulic Actuation
It is necessary to use the PVHC in combination with 25 bar [362.6 psi] pilot pressure, and standard FC spools fitted for hydraulic actuation. See PVG 32 Technical Information 520L0344 and PVG 100 Technical Information 520L0720. Because of the 25 bar pilot pressure, it is not possible to combine PVHC with PVE on a PVG 32 or PVG 100 valve stack. PWM current control signals. AMP JPT and Deutsch DT connector options. 12 V or 24 V supply options. Only to be used with 25 bar pilot pressure and hydraulic main spool. Possible to option mount the PVHC on PVG 32 and PVG 100.
Features
32
Oil viscosity
Range Minimum Maximum
12 - 75 mm2/s [65 - 350 SUS] 4 mm2/s [40 SUS] 400 mm2/s [2130 SUS]
Enclosure
Connector type
Deutsch DT AMP JPT 12/24 V
Protection class
IP 67 IP 66
Input control
Parameter Output current range Resistance Control pressure range Control range 12 V
0 - 1500 mA 4.75 5%
24 V
0 - 750 mA 20.8 5%
Connections
Deutsch Version
Pos. 1 1 1
Description
Housing Lock Part Pin Contact
Qty
1 1 2 2
V310 004.A
AMP Version
Pos. 1 2 3 4
Description
Connector Contacts Contacts Superseal
Qty
1 2 2 1
3 2 1
V310 003.A
33
Q P E
1
A/B US gal/min 25
l/min 100 90 80
B
1
8 70
20
8 1
1 60 8 50 40 30 20 10 0 15
8 1 8
C B A AA
7
1 8
10
C B
A AA
0 0 1 0.04 1.5 2 3 0.12 4 0.16 5 0.20 6 0.24 7 0.28
6 0.24
5 0.20
4 0.16
3 0.12
1.5
a mm a in
PVM PVM
0.28
0.08 0.04
0.08
V310 001.A
Spool stroke, mm
7 6 5 Ideal curve 4 3 2 1 Current in mA 1000 1200 1400 1600 800 @ 12V @ 24V
Hysteresis
800
600
400
200
200
400
1200
1600
1400
600
1000
400
500
300
200
600 300
100
100
200
400
800
800
700
500/1000 mA
280/560 mA
280/560 mA
500/1000 mA
500
600
700
V310 000.A
The ideal curve is determined by the main spool neutral spring. The hysteresis is affected by viscosity, friction, flow forces, dither frequency and modulation frequency.
34
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVP, Pump Side Moduls
Symbol Description P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 Closed centre pump side module for pumps with vaiable displacement. P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 Open centre pump side module for pumps with fixed displacement. With pilot oil supply for electrically actuated valves Connection for electrical LS unloading valve, PVPX Closed centre pump side module pumps with variable displacement With pilot oil supply Connection for electrical LS unloading valve, PVPX P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 P=G T=G P = 7814 T = 111612 P, T = G P, T = 111612 Code number 157B5000 157B5200 157B5100 157B5300 157B5001 157B5201 157B5101 157B5301 157B5010 157B5210 157B5110 157B5310 157B5011 157B5211 157B5111 157B5311 157B5012 157B5212 157B5112 157B5312 157B5013 157B5213 157B5113 157B5313
Open centre pump side module for pumps with fixed displacement. For purely machanically actuated valve groups
Open centre pump side module for pumps with fixed displacement. With pilot oil supply for electrically actuated valves
Closed centre pump side module pumps with variable displacement. With pilot oil supply for electrically actuated valves
Connections: P = G in; 14 mm deep or G in; 16 mm deep / LS, M = G in; 12 mm deep / T = G in; 16 mm deep. P = 7814; 0.65 in deep or 111612; 0.75 in deep / LS, M = 20; 0.47 in deep / T = 111612; 0.75 in deep.
520L0344 Rev HA Nov 2011
35
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVP, Pump side moduls
Symbol Description Open centre pump side module for pumps with fixed displacement. For mechanical actuated valves. Connection for LS unloading valve, PVPX. P, T = G 157B5102 Code number
Closed centre pump side module for pumps with vaiable displacement. For mechanical actuated valves. Connection for LS unloading valve, PVPX. P, T = G 157B5103
Open centre pump side module for pumps with fixed displacement. With pilot oil supply for electrical actuation and connection for pilot oil pressure
P, T = G
157B5180
P, T = 111612
157B5380
Closed centre pump side module pumps with variable displacement. With pilot oil supply for electrical actuation and connection for pilot oil pressure
P, T = G
157B5181
P, T = 111612
157B538
Open centre pump side module for pumps with fixed displacement. With pilot oil supply for hydraulic actuation and connection for pilot oil pressure
P, T = G
157B5190
P, T = 111612
157B5390
Closed centre pump side module pumps with variable displacement With pilot oil supply for hydraulic actuation and connection for pilot oil pressure
P, T = G
157B5191
P, T = 111612
157B5391
Connections: P, T = G in; 16 mm deep / LS, M = G in; 12 mm deep P, T = 111612; 0.75 in deep / LS, M = 20; 0.47 in deep.
36
520L0344 Rev HA Nov 2011
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVB, Basic Modules Without Adjustable LSA/B Pressure Limiting Valves
Symbol Description Code number No facilities for Facilities for shock valves A/B shock valves A/B
Without load drop check valve and pressure compensator. Can be used where load holding valves prevent oil from flowing back through channel P.
G 14 mm deep
157B6000
157B6030
157B6400
157B6430
157B6100
157B6130
157B6500
157B6530
Load drop check valve. LSA/B shuttle valve. To be used with float position spools.
G 14 mm deep
157B6136
157B6536
157B6200
157B6230
157B6600
157B6630
37
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVB, Basic Modules - Without Adjustable LSa/b Pressure Limiting Valves
Symbol Description Code number No facilities for Facilities for shock valves A/B shock valves A/B
11071832
G 14 mm deep
157B6206
157B6236
38
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVB, Basic Modules - With Adjustable LSa/b Pressure Limiting Valves
Symbol Description Code number No facilities for Facilities for shock valves A/B shock valves A/B
G 14 mm deep
157B6203
157B6233
External LS connection port A/B. Also used for float 7814 0.65 in deep position spools.
157B6603
157B6633
Damped compensator valve. Adjustable LSA/B pressure limiting valves External LS connection port A/B.
G 14 mm deep
157B6208
157B6238
11036631
39
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVM, Mechanical Actuation
Symbol Description PVM, Standard, spring centered Individual oil flow adjustment to ports A and B Without actuation lever and base. Shaft for mounting of actuation lever PVM, as standard, witout actuation lever. With base for mounting of actuation lever PVM, Standard, spring. Individual oil flow adjustment to ports A and B. (Anodized) 22.5 37.5 22.5 22.5 37.5 Code number with stop screws w/o stop screws 157B3171 157B3172 157B3173 157B3175 157B3174 157B3184 157B3191 157B3192 157B3193 157B3195 157B3194 -
157B0005
40
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVLA, Suction Valve (fitted in PVB)
Symbol Description Code number
157B2001
Plug for connecting the nonactive port to tank, when using a single acting spool.
157B2002
41
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVS, End Plate
Symbol Description PVS, without active elements. No connections Code number 157B2000 157B2020 G 1/8 10 mm deep 3/8 in - 24; 0,39 in deep 157B2011 157B2021 157B2014 157B2004 G 1/4 10 mm deep 1/2 in - 20; 0,47 in deep 157B2015 157b2005
V310062.A
LX
V310063.A
PVS, without active elements. Max. intermittend LX pressure 250 bar [3625 psi]
V310062.A
PVSI, without active elements Without connections. PVSI, without active elements LX connections. Max. intermittend LX pressure: 350 bar [5075 psi]
LX
V310063.A
0
8000 0.1[0.2]
1
8001 8021
2
8002 8022
3
8003 8023
4
8004 8024
5
8005 8025
6
8006 8026
7
8007 8027
8
8008 8028
9
8009 8029
10
8010 8030
11
8061 8081
12
8062 8082 0.9 [2.0]
0.15 [0.3] 0.25 [0.6] 0.30 [0.7] 0.40 [0.9] 0.45 [1.0] 0.50 [1.1] 0.60 [1.3] 0.65 [1.4] 0.70 [1.6] 0.80 [1.7] 0.85 [1.8]
42
PVG 32 Proportional Valve Group Technical Information Modules and Code Numbers
PVPX, Electrical LS Unloaded Valve
Symbol Description PVPX, Normally open: LS pressure relieved with no signal to PVPX PVPX, Normally closed: LS pressure relieved with no signal to PVPX PVPX, Normally open with manual override: LS pressure relieved with no signal to PVPX Manual override DE-selects LS-pump Plug 12 V 24 V 12 V 24 V 12 V 24 V 26 V Code number 157B4236 157B4238 157B4246 157B4248 157B4256 157B4258 157B4260 157B5601
G 12 mm deep PVP, Plug without check valve for open or closed centre 20; 0.47 in deep
157B5400
G 12 mm deep PVP, Plug with check valve for open centre 20; 0.47 in deep
157B5600
157B5700
43
44
US UDC 1 8
= = = =
Signal voltage Supply voltage First PVB after PVP Eighth PVB after PVP
45
US UDC 1 8
= = = =
Signal voltage Supply voltage First PVB after PVP Eighth PVB after PVP
46
Oil flow QA/B as a function of supplied pump oil flow (QP) The pressure drop of any oil flowing back to tank (QP - QA/B) is read on the curve for neutral flow pressure in PVP. Characteristic for fully displaced flow control spools.
47
Set pressure difference between pump pressure and LS signal = 20 bar [290 psi].
The oil flow is dependent on the pressure difference between the pump pressure and the LS signal. Normally the pressure difference is set at the LS pump regulator.
48
Characteristic for pressure drop PVB for open spool in neutral position
49
50
PVLA,Suction Valve
51
Size C:
52
Size E:
Pressure build-up Max. oil flow can be reduced by about 50% without limitation of maximum pressure by limiting the main spool travel from 7 mm [0.28 in] to 5.5 mm [0.22 in]
53
54
4.8 mm [0.19 in] spool displacement in direction A gives max. oil flow to port A 4.8 mm [0.19 in] spool displacement in direction B gives max. oil flow to port B 8 mm [0.32 in] spool displacement in direction B gives completely open float position A/B T. The spools have 4,8 mm spool travel in direction A and 8 mm travel in direction B:
55
Spools D and E have the same opening area for forward flow and return flow. Spool E can give 100 l/min [26.4 US gal/min] pressure compensated oil flow due to a higher pressure drop across spool E. This occurs during spool actuation only. Pressure drop A/B T in float position
56
38.5[1.516]
141[5.55]
70.5[2.776]
LS I J
58.5[2.303] 34.5[1.358] 79.5[3.130] 95[3.74]
23[0.91]
38.5[1.516]
16.5[0.650] 12[0.47]
35[1.38]
48[1.89]
PVS=11.5[0.453] PVSI=12[0.47]
B4
A4
B3
B
B2
A3
38.5[1.516]
112.5[4.430] 115.5[4.457]
B L L
1 2
A2 22[0.87]
B1
C
37[1.46] 48[1.89]
A1
Q
24[0.94] 23[0.91]
23[0.91]
37[1.46] 85.5[3.366]
21[1.118] 36.5[1.437]
F: G: H: I: J: K: L: M: N: O: P: Q: R: S:
Shock and suction valve, PVLP V310140.A Pressure gauge connection; G 1/4, 12 mm deep [1/2 in-20, 0.47 in deep] Plug for external pilot oil supply, PVPC; G 1/2, 12 mm deep [1/2 in-20, 0.47 in deep] Electrical LS unloading valve, PVPX LS connection; G 1/4, 12 mm deep [1/2 in-20, 0.47 in deep] Fixing holes; M8 min. 10 [5/16 in-18, 0.47 in deep] Port A and B; G 1/2, 14 mm deep [7/8 in-14, 0.65 in deep] LX connection: PVS; G 1/8, 10 mm deep [3/8 in-24, 0.39 in deep] and PVSI; G 1/4, 12 mm [0.47 in] deep [1/2 in-20, 0.47 in deep] LS pressure limiting valve Tank connection; G 3/4, 16 mm deep [1 1/16 in-12, 0.75 in deep] Pressure relief valve Pump connection; G 1/2, 14 mm deep or G 3/4, 16 mm deep [7/8 in-14, 0.65 in deep or 1 1/16 in-12, 0.75 in deep] LSA and LSB connections; G 1/4, 12 mm [0.47 in] deep [1/2 in-20, 0.47 in deep] Pp, pilot pressure connection G 520L0344 Rev HA Nov 2011
57
A-A
2] 44 [ 1.73
110[4.33] max.200.5[7.894] 17[0.67] 60[2.36]
32[1.26]
85[3.35] 58.5[2.303]
45[1.77]
P V M R / F
P V H
P V M D
7[0.28]
6.5[0.256]
85.5[3.366]
13[0.51]
7[0.28]
49.5[1.949]
33[1.30]
85[3.35]
B-B
129[5.08] 95[3.74]
PVEO
7[0.28]
107[4.21]
110[4.33] max.290.50[11.437]
60[2.36]
89.5[3.524]
C-C
139[5.472]
117[4.61]
PVEM/PVEH/ PVES
7[0.28]
107[4.21]
110[4.33] max.290.50[11.437]
60[2.36]
~1
V310141.A
58
65[
6.5
0]
19.5
19 .5
19.
.5 19
37.5
67
.5
.5 97
22.5
52
.5
82
127
.5
.5
11 2.5
157.5
V310014.A
142.5
172.5
V310018.A
187.5
59
C: Over-centre valve
60
61
62
63
AA 5 [1.3]
ISO symbol
Symbol
AA 5 [1.3]
7033
7032
7031
7030
7015
7010
7011
7012
7013
7134
7133
7132
7131
7130
7115
7110
7111
7112
7113
7064
7063
7062
7061
7040
7041
7042
7043
7044
7074
7073
7072
7071
7050
7051
7052
7053
7054
7164
7163
7162
7161
7150
7151
7152
7153
7154
7174
7173
7172
7171
7150
7151
7152
7153
7154
64
AA 5 [1.3]
ISO symbol
Symbol
AA 5 [1.3]
7473
7472
7471
7470
7452
7453
7563
7562
7541
7542
7543
65
AA 5 [1.3]
ISO symbol
Symbol
AA 5 [1.3]
9015
9010
9011
9012
9042
9043
9044
9052
9053
9054
66
To be used when PVB is without LSA/B shuttle valve Size Press. compensated flow l/min [US gal/min]
AA 5 [1.3] A 10 [2.6] B 25 [6.6] C D E F 40 65 100 130 [10.6] [17.2] [26.4] [34.3]
ISO symbol
Symbol
7026
7024
7023
7022
7021
7020
7005
7000
7001
7002
7003
7004
7006
7126
7124
7123
7122
7121
7120
7105
7100
7101
7102
7103
7104
7106
7200
7201
7202
7203
7204
7301
7302
7303
7304
67
To be used when PVB is without LSA/B shuttle valve Size Press. compensated flow l/min [US gal/min]
AA 5 [1.3] A 10 [2.6] B 25 [6.6] C D E F 40 65 100 130 [10.6] [17.2] [26.4] [34.3]
ISO symbol
Symbol
7424
7423
7422
7421
7401
7402
7403
7404
7406
7524
7523
7522
7521
7501
7502
7503
7504
7624
7623
7622
7621
7620
68
AA 5 [1.3]
ISO symbol
Symbol
AA 5 [1.3]
9024
9023
9022
9021
9020
9005
9000
9001
9002
9003
9004
9124
9123
9122
9121
9120
9105
9100
9101
9102
9103
9104
AA 5 [1.3]
ISO symbol
Symbol
AA 5 [1.3]
9724
9723
9722
9721
9720
9700
9701
9702
9703
9704
9734
9733
9732
9731
9730
9710
9711
9712
9713
9714
69
To be used when PVB is without LSA/B shuttle valve Size Press. compensated flow l/min [US gal/min]
AA 5 [1.3] A 10 [2.6] B 25 [6.6] C D E F 40 65 100 130 [10.6] [17.2] [26.4] [34.3]
ISO symbol
Symbol
9824
9823
9822
9821
9820
9624
623
9622
9621
70
To be used when PVB is without LSA/B shuttle valve Size Press. compensated flow l/min [US gal/min]
AA 5 [1.3] A 10 [2.6] B 25 [6.6] C D E F 40 65 100 130 [10.6] [17.2] [26.4] [34.3]
ISO symbol
Symbol
9774
9773
9772
9771
9750
9751
9752
9753
9754
9784
9783
9782
9781
9760
9761
9762
9763
9764
9794
9804
71
Without compensator /check valve With check valve With check valve and LSA/B shuttle valve With compensator valve With damped compensator valve With compensator valve, LSA/B relief valve and LSA/B shuttle valve With damped compensator valve, LSA/B relief valve and LSA/B shuttle valve Weight kg [lb]
6100
6200 6206
6203 6208
6603
-
6233 6238
6633
-
3.1 [6.8]
3.0 [6.6]
PVPC, plugs
Description External pilot supply External pilot supply incl. check valve G 5400
5600
in - 20
5700
Weight kg [lb]
0.05 0.05 0.1 0.1
1-10 13
11 a 12
Description Standard Standard with base, without arm and button Standard without base, without arm and button Weight kg [lb]
Angle
22,5/37,5 22,5/37,5
0.4 [0.9]
0
8000 -
1
8001 8021
2
8002 8022
3
8003 8023
4
8004 8024
5
8005 8025
6
8006 8026
7
8007 8027
8
8008 8028
9
8009 8029
10
8010 8030
11
8061 8081
12
8062 8082
Weight kg [lb] 0.1[0.2] 0.15 [0.3] 0.25 [0.6] 0.30 [0.7] 0.40 [0.9] 0.45 [1.0] 0.50 [1.1] 0.60 [1.3] 0.65 [1.4] 0.70 [1.6] 0.80 [1.7] 0.85 [1.8] 0.9 [2.0]
72
Open centre
P = G 1/2, T = G 3/4 P = 7/8 in - 14, T = 1 1/16 in - 12 P = G 3/4, T = G 3/4 P = 1 1/16 in - 12, T = 1 1/16 in - 12 P = G 1/2 , T = G 3/4, P = 7/8 in - 14, T = 1 1/16 in - 12 P = G 3/4, T = G 3/4, P = 1 1/16 in - 12, T = 1 1/16 in - 12 kg [lb]
0 0 1-10 13
0.3 [0.7]
11 a 12
0.06 [.13]
V310168.A
[psi] 460
73
kg [lb]
0 0 1-10 13
PVEA, active fault mon. PVEA, passive fault mon. PVEA-DI, active fault mon. PVEA-DI, passive fault mon. PVEH active fault mon. PVEH passive fault mon.
0.9 [2.0]
11 a 12
PVEH float -> B, act. fault PVEH float -> A, act. fault PVEH- DI active fault mon. PVEH - DI passive fault mon.
kg [lb]
no 0.1 [0.2] yes n/a 0.9 [2.0] no yes n/a 0.3 [0.6]
PVMF (Mech. float position) Hydraulic actuation PVH 9/16-18 UNF Hydraulic actuation PVH G1/4
157B0005 aluminium 157B0007 157B0010 157B0014 157B0008 157B0011 157B0016 aluminium iron aluminium iron
74
75
Max. pressure setting of LSA and LSB valves relative to PVLP shock valve
Setting pressure for PVL Max. setting pressure for LSA/B Min. setting pressure for LSA/B
bar [psi] bar [psi] bar [psi] 32 460 50 725 40 580 63 80 100 125 140 150 160 175 190 210 230 240 250 265 280 300 320 350 914 1160 1450 1813 2031 2175 2320 2838 2755 3045 3335 3480 3625 3843 4061 4351 4641 5075 50 720 64 80 100 112 120 130 145 160 180 200 210 220 235 250 270 290 320
930 1160 1450 1625 1740 1885 2100 2320 2610 2900 3045 3190 3408 3625 3915 4205 4641 30 435
76
Specification Sheet
PVG 32
Function
A-Port
157B
157B bar 157B 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB 157B bar LSB
B-Port
p=
a b a b a b a b a b a b a b a b a b a b
Remarks
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
157B LSA
13
bar
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
c b c b c b c b c b c b c b c b c b c b
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
157B LSA
13
bar
10
157B LSA
13
bar
11 12
157B 157B
Filled in by
Date
PHYD-PVG32-3
Separate specification pads are available under the literature no. 520L0515.
77
PVG 32
Function
A-Port
157B
157B psi 157B 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB 157B psi LSB
B-Port
p=
a b a b a b a b a b a b a b a b a b a b
Remarks
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
157B LSA
13
psi
157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B 157B
c b c b c b c b c b c b c b c b c b c b
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
157B LSA
13
psi
10
157B LSA
13
psi
11 12
157B 157B
Filled in by
Date
PHYD-PVG32-3
78
77
79
Products we o er: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives
Sauer-Danfoss is a global manufacturer and supplier of highquality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile o -highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of o -highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics.
Wherever o -highway vehicles are at work, so is Sauer-Danfoss. We o er expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.
Members of the Sauer-Danfoss Group: Comatrol www.comatrol.com Schwarzmller-Inverter www.schwarzmueller-inverter.com Turolla www.turollaocg.com Hydro-Gear www.hydro-gear.com Sauer-Danfoss-Daikin www.sauer-danfoss-daikin.com
Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Fax: +1 515 239 6618 Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D-24531 Neumnster Krokamp 35, D-24539 Neumnster, Germany Phone: +49 4321 871 0 Fax: +49 4321 871 122
Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: +45 7488 4444 Fax: +45 7488 4400
Sauer-Danfoss-Daikin LTD. Shin-Osaka TERASAKI 3rd Bldg. 6F 1-5-28 Nishimiyahara, Yodogawa-ku Osaka 532-0004, Japan Phone: +81 6 6395 6066 Fax: +81 6 6395 8585
www.sauer-danfoss.com