Presented By: Prasant Kumar Behera Engineer (Operation) EMP NO:100792
Presented By: Prasant Kumar Behera Engineer (Operation) EMP NO:100792
SEAL OIL SYSTEM LUBE OIL SYSTEM ROTOR COOLING(H2 GAS) STATOR COOLING(PRIMARY WATER) Excitation system AVR ,DVR LLD
Source of Heat
Losses
Stator/Rotor Winding Copper Losses Core Losses Friction & Windage Losses The load-carrying ability of the stator winding is determined by the maximum allowable temperature of the winding insulation.
ROTOR COOLING
Excitation system
Sensitivity and fast response Stability Ability to meet abnormal conditions Monitoring and annunciation of parameters User friendliness
G
Rectifier Transformer PT Slip Ring Generator
Voltage Regulator
Manual Control
FIELD FLASHING
For start up DC excitation is fed to the field from external source like station battery or rectified AC from station Ac supply . Filed flashing is used to build up voltage up to 30 %. From 30 to 70 % both flashing and regulation remains in circuit. 70 % above flashing gets cut-off
BRUSHLESS EXCITATION
FIELD BREAKER
ARMATURE ROTATING DIODES
R Y B
Pilot Exciter
Main Exciter
Generator
Rotating Rectifier
Armature Field CT
PT 3 Ph AC
Field
Rotor
Thyristor Rectifier
DC
Voltage Regulator
Manual Control
AVR
21 KV
EXCITER ROTOR
MAIN EXCITER
Rotor
Stator
Magnetic
PILOT EXCITER
Stator 2. Permanent magnet rotor 3. Stator winding
1.
RECTIFIER WHEEL
Rectifier wheel 2. Three phase lead 3. Heat sink 4. Diode 5. Fuse 6. Multikontact plug in-bolt
1.
M.S
C.R.H
H. R. H
FROM F.R.S
5 December 2012
PMI Revision 00
46
GENERAL SCHEME
Steam from boiler
Opening SV Opening CV
Acceleration
Tripping
100MW 80MW 120MW 120MW 80MW 3000rpm 3000RPM 2900 3000rpm 3100rpm
rpm
Turbine
Generatin g Station
Generator Speed
Load Consumer
3150
3100
3000
2900
2850
1500
180
HP TURBINE
MS
IP TURBINE
LP TURBINE
TG SET
CRH NRV
HPSV
HPCV
IPSV IPCV
GENERATOR
HPSV
IPCV IPSV
MS
HRH
Condenser
BOILER