Defect Analysis Report (Tuner)
Defect Analysis Report (Tuner)
SOEM
Problem Detail
Tettei Be thorough
NG Photo
OK Photo
NG
FM Left channel Dead
OK
FM L and R channel
Comment: FM left channel dead is due to IC101 left channel become open
SOEM
Chronology
Tettei Be thorough
16th.Oct 17th.Oct 18th.Oct
Kaga
Normal
sorting HR=01
3/700 sets
FM Left Channel no output
FM Left Channel no output
sorting
FM Left Channel no output
3/700 sets
4/700 sets
SOEM
Background
Tettei Be thorough
Process at Kaga
Auto mount
Dummy FPC
Checker
Checker to check radio function including FM left and right channel
Discharge circuit
Hand mount Dipping ICT
For inspection operator need to insert dummy FPC wire into Tuner1 connector
PWB breaking
Checker Inspection
Transport
SOEM
Defect Analysis
Tettei Be thorough
FM L channel dead is having open circuit between pin 2 (LCH) and Gnd at IC 101
IC 101 damage
OK pwb
Reject pwb
SOEM
Tettei Be thorough
Step Analysis
Static Discharge
Analysis flow
Hand Mount static Assembly station static Operator wrist strap
Status
Value less than 50V >OK Value less than 50 V> OK OK
Checker is equipped with discharge circuit where the voltage will discharge immediately after checking is completed and ready for next set to be inspected. > OK
FPC checking. Due to wear and tear issue, customer provide 1 FPC for every 100 sets.( As each bin contains 50 pcs.> operator will interchange end 1 and end 2.) >NG
Short circuit
2 1
SOEM
Tettei Be thorough
Study on FPC used on 18th.Oct
NG
NG
NG
3/12 FPC were found to be damaged/blister after 50 times insertion and pulling
2/12 FPC were found to be damaged/blister after end of 50 times insertion and pulling
SOEM
USED FPC
Tettei Be thorough
Terminal bend
Pin 1, 2, 3,4,5,6,7,8,9,10l
SOEM
Due to FPC used at Function checker having condition of short or almost short condition. This is due to FPC contact points having wear and tear condition after 50 times insert and pull
Countermeasure:
Temporary 1) Reduce FPC recycle from 50 times each to 25 times insert and pull for each end 2) Perform resistance for left and right channel after function test
Countermeasure:
To perform resistance check after inspection station
SOEM
Stock Treatment
Tettei Be thorough
Sorting by (at SOEM) Result 10/1919 NG Marking R OK on Bin Date 19 th.OCT 2013 Completed sets Sorting by . Result Not applicable Date
SOEM
Preventive Action
Tettei Be thorough
Yokothenkai modification from using FPC to jig pin to other Sony models such as Tuner2 checkers.
SOEM
Tettei Be thorough
SOEM