0% found this document useful (0 votes)
74 views

How The Disturbance at Grids Is Recorded

Numerical relays and disturbance recording provide improved protection, monitoring, and analysis capabilities compared to conventional technology. Multifunction numerical relays integrate overcurrent, earth fault, voltage, and directional earth fault protection, along with disturbance recording functions. The relays offer configurable settings, self-monitoring, communication interfaces, and enhanced network supervision compared to older relay technologies.

Uploaded by

ajs009
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views

How The Disturbance at Grids Is Recorded

Numerical relays and disturbance recording provide improved protection, monitoring, and analysis capabilities compared to conventional technology. Multifunction numerical relays integrate overcurrent, earth fault, voltage, and directional earth fault protection, along with disturbance recording functions. The relays offer configurable settings, self-monitoring, communication interfaces, and enhanced network supervision compared to older relay technologies.

Uploaded by

ajs009
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 18

HOW THE DISTURBANCE AT

GRIDS IS RECORDED
WE ARE NOW GOING TO LEARN ABOUT
THIS TOPIC
Numerical Relays and
Numerical Disturbance
Relays And
Recording
Disturbance Recording

By
Engr. Syed Husnain Shah
Conventional Technology
control panel, separate relay room, connectivity through
hardwiring.

New Technology
local control, multifunction relays, connectivity through serial
communication.
Multipurpose protection relay series

Overcurrent & earth-fault relays:


REJ 525 & REJ 515
Overcurrent relays:
REJ 523 & REJ 513
Voltage relays: Earth-fault relays: Directional earth-fault relays:
REU 523 & REU 513 REJ 521 & REJ 511 REJ 527 & REJ 517
Features
 A wide range of protection functions
 Wide and accurate numerical settings with perfect
long-time stability
 Two sets of relay settings available
 Recorded and time-stamped data of the latest 5 events
 Event code buffer of the latest 60 events
 Disturbance recording function for fault analysis
 Output relay functions freely configurable for tripping
and signalling
 Circuit-breaker failure protection unit
Features
 Binary input for blocking, external resetting, triggering and
selection of setting group
 Optical serial interface on the front panel for communication
with portable computer
 Powerful and easy-to-use software tools for relay setting
 High system reliability and availability due to continuous
hardware and software self-supervision
 High immunity to electrical and electromagnetic interference
 Relay case with a degree of protection according to IP 54
 Rated frequency user-selectable 50/60 Hz
 CE marking according to the EC directive for EMC
The supervision of your network will be
enhanced by using Numerical relays

1-Easy to use - ready made nfigurations = local


adaptations are not needed
2-Wide protection functionality - covering the
most essential protection functions
3-Condition monitoring functions - for continuos
supervision
4-Control functions - local or remote
Measurements
5-Connectivity - for remote control and monitoring
6-Easy to integrate in systems through
communication protocols
7-Easy to order
Functionality
• Communication
• Control – SPA, LON and IEC103
– Control of one circuit breaker protocol
– Set values, measured values,
– Indication of 3 objects
registered values / events,
– Pre-programmed interlocking uploading of disturbance
conditions recorder data, control, etc.
• Condition Monitoring available trough
communication
– Self supervision (IRF)
• Easy to use
– Trip circuit supervision
– Measured values shown as
– Circuit-breaker wear primary values
– Phase current supervision (MCS – The settings are made in
3I) primary values
– Phase voltage supervision (MCS– Easy menu navigation
3U) – MMI in several languages
Everything in one box
Flexibility

 Full range of protection, measuring,


control and supervision functions
 Large amount of generic functions
 Freely drawable mimic view
 Freely programmable alarm indications
 Freely configurable function button

Application-specific functionality
• Protection Functions – Residual overvoltage
– Auto-reclosing (5 shots) – Synchro/voltage-check
– Phase discontinuity – Thermal overload for cables
– Non-directional earth-fault
– Directional earth-fault
– Non-directional overcurrent
– Directional overcurrent
– Under/overfrequency
– Transformer inrush and motor
start-up current detector
– Overvoltage
– Undervoltage
Substation automation (SCS)

 Protection
 Monitoring and control
 Communication with NCC
 Power quality measurements
 Time synchronization
 Interlocking
 Metering
 MV & HV
Event Capture From Aug. 14,
2003
How are you Feeling?????? After
listening to this lecture????
You must be feeling Like………..
??????This
THANKS FOR YOUR PATIENCE