Tuto 4
Tuto 4
Email: [email protected]
QUESTIONS
A+B C
follows an elementary rate law and is carried out isothermally in a flow system.
The concentrations of A & B feed streams are 2 M before mixing. The volumetric
flow rate of each stream is 5 dm3/min, and the entering temperature is 300 K. The
streams are mixed immediately before entering. Two reactors are available. One is
gray 200 dm3 CSTR that can be heated to 77C or cooled to 0C, and the other is a
white 800 dm3 PFR operated at 300 K that cannot be heated or cooled but can be
painted red or black. Note k = 0.07 dm3/mol.min at 300 K and E = 20 kcal/mol.
(a)
(b)
Calculate time taken to achieve 90% conversion in a 200 dm3 batch reactor with
CA0 = CB0 = 1 M after mixing at a temperature of 77C.
(c)
(d)
Calculate the conversion if the CSTR and PFR were operated at 300 K and
connected in series. The entering volumetric flow rate is 10 dm3/h.
(e)
Repeat part (d) if CSTR and PFR are connected in parallel with an entering
flow rate of 5 mol/min to each of the reactor.
FA0 X
1. Design equation: V
rA
2. Rate Law:
rA kC AC B
3. Stoichiometry:
C A C AO 1 X
C B C AO 1 X
4. Combine:
FA0 X
V 2
2
kC A0 1 X
3
VCSTR 200dm 3 C A0 1 mol dm
Solving for X,
FA0 X
V 2
2
kC A0 1 X
X 0.925
200dm 2
10 mol min X
1 X
2
dX
1. Design equation: V FA0
rA
0
2. Rate Law: rA kC AC B
3. Stoichiometry:
C A C AO 1 X
C B C AO 1 X
4. Combine:
FA0
V 2
kC A0
dX
0 1 X 2
5. Solving for X:
X= 0.85
VkC A2 0
X
1 X
FA0
VPFR 800dm 3
C A0 1 mol dm 3
FA0 10mol / min
k 0.07 dm 3 mol min
1. Design equation:
2. Rate Law:
N A0
dX
rAV
dt R
rA kC AC B
3. Stoichiometry:
C A C AO 1 X
C B C AO 1 X
4. Combine:
dX
2
1 X 2V
N A0
kC AO
dt R
5. Solving for t:
dX
2
1 X 2
C A0
kC AO
dt R
dX
2
kC AO 1 X
dt R
R
dX
0 1 X 2 kC AO 0 dt R
5.
Solving for t:
dX
2
kC AO 1 X
dt R
tR
R
dX
0 1 X 2 kC AO 0 dt R
1 X kC AO
0.9
1 X kC AO
20000 1
1
Thus, t R
1 X kC AO
(d) Calculate the conversion if the CSTR and PFR were operated at 300 K
and connected in series. The entering volumetric flow rate is 10 dm3/h.
v0=10 dm3/h.
X ?
VCSTR
FA0 X
2
2
kC A0 1 X
VCSTR kC A2 0 1 X
VCSTR kC A2 0 1 X
X
FA0
C A0 v0
2
X 0.44
(d) Calculate the conversion if the CSTR and PFR were operated at 300 K
and connected in series. The entering volumetric flow rate is 10 dm3/h.
v0=10 dm3/h.
X 0.44
FA0
V 2
kC A0
dX
0.44 1 X 2
X ?
FA0 1
1
V 2
kC A0 1 X 1 0.44
C A0 v0 1
800dm
1.7857
2
kC A0 1 X
3
10 dm min
1
3
800dm
1.7857
3
3
0.07 dm mol min 1 mol dm 1 X
X 0.865
3
(e) Repeat part (d) if CSTR and PFR are connected in parallel with an
entering flow rate of 5 dm3/h to each of the reactor.
5 dm3/h.
X ?
10 dm3/h.
5 dm3/h.
VCSTR kC A2 0 1 X
VCSTR kC A2 0 1 X
X
FA0
C A0 v0
2
X 0.56
(e) Repeat part (d) if CSTR and PFR are connected in parallel with an
entering flow rate of 5 dm3/h to each of the reactor.
5 dm3/h.
X 0.56
10 dm3/h.
5 dm3/h.
X ?
FA0
V 2
kC A0
dX
0 1 X 2
VkC A2 0
X
1 X
FA0
3
1 X
5 dm min
X 0.91