Wcdma Drop Call Analysis
Wcdma Drop Call Analysis
OBJECTIVES
A call drop occurs if the connection is lost any time after the UE
has completed RAB(Radio Access Bearer) Setup complete on the
uplink.
CAUSES
Missing NBH
Soft Handover
UL Synchronization
Congestion
IRAT Failure
Too High/Low UL RSSI
CAC Parameter
Load Sharing
Pilot Pollution
Other
MISSING NBH
Check the missing NBS by collecting dump Add NB/NBH audit required
SOFT HANDOVER
Check Source Cell CAC parameters Pwr Adm, Pwr Offest, Dlcode ADM
-90,-85 // -14,-
Check 2D/2F Parameters./ Direct Retry To GSM 2D RSCP, 2F RSCP // 2D EcIo, 2F EcIo
12
Sintrasearch 4
For Cell
Sintersearch 3
Reselection
Ssearchrat 1
Check UL RSSI -85 to -110 -95 below
Due To SRB & TRB Reset, Due To High UL Signaling Radio Barrier, Traffic Radio
BLER Barrier
Due To Improper LAC Boundary
Not to take call from cell edge (far from
Limit Rxlevelmin/ reduce CPICH Pwr
the serving cell)
CONGESTION
DL Pwr Congestion
UL Pwr Congestion
Code Congestion
IUB Congestion
CONGESTION
Faulty Antenna
incorrect plumbing
Bad connection
CAC PARAMETER
Check
Alarm
Lock Site
Transmission Issue
Hardware Issue
THANK YOU!!