0% found this document useful (0 votes)
50 views

Introduction Load Reshuffling

The document proposes lowering the LDR trigger thresholds from 55 to 45 and from 45 to 35 to reduce cell load and increase access success rate when a cell enters a basic congestion state. It also recommends values for LDR actions to optimize performance.

Uploaded by

Sandeep
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views

Introduction Load Reshuffling

The document proposes lowering the LDR trigger thresholds from 55 to 45 and from 45 to 35 to reduce cell load and increase access success rate when a cell enters a basic congestion state. It also recommends values for LDR actions to optimize performance.

Uploaded by

Sandeep
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 2

LDR Introduction

When the usage of cell resource


exceeds the basic congestion triggering
threshold, the cell enters the basic
congestion state. In this case, Load
Reshuffling (LDR) is required to reduce
the cell load and increase the access
success rate.
1
LDR Parameter Proposal

To reduce the cell load, suggest to set the LDR trigger threshold and LDR action as
below:

Currently
LDR Propose Setting
Setting
ULLDRTRIGTHD 55 45
ULLDRRELTHD 45 35
DLLDRTRIGTHD 70 70
DLLDRRELTHD 60 60

Recommend Value for


Command Parameter Name
Optimizatoin
ADD UCELLLDR DLLDRFIRSTACTION CSInterRatShouldNotLDHO
ADD UCELLLDR DLLDRSECONDACTION BERateRed
ADD UCELLLDR DLLDRTHIRDACTION InterFreqLDHO
ADD UCELLLDR DLLDRFOURTHACTION CodeAdj
ADD UCELLLDR ULLDRFIRSTACTION BERateRed
ADD UCELLLDR ULLDRSECONDACTION InterFreqLDHO
ADD UCELLLDR ULLDRTHIRDACTION CSInterRatShouldNotLDHO