You are on page 1/ 10

Security Level:

RNC in Pool
O&M and Troubleshooting

www.huawei.com

Department: Wireless NTD


Author/ID: Hong XiaoQin/00333851
Version: V1.0 (20161008)
HUAWEI TECHNOLOGIES CO., LTD.
Contents

 Rules for Reporting Alarms, Traffic Statistics, and Logs


 RNC in Pool Load Sharing Traffic Statistics
 Troubleshooting

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2


Rules for Reporting Traffic Statistics
The master RNC reports logical traffic statistics Each physical RNC reports physical traffic statistics

Counters

Overflow
RNC

Counters

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


Rules for Reporting Alarms
Each physical RNC reports its alarms
Only the master RNC reports service alarms.
(such as transmission alarms) respectively.

On RNC in Pool Node Redundancy networks, if a


NodeB control switchover is performed, the preceding
alarms are cleared and then detected and reported by
the new master RNC.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Rules for Reporting Logs
Log reporting in RNC in Pool Load Sharing scenarios Log reporting in RNC in Pool Node Redundancy scenarios

Networking RNC in Pool Load Sharing Networking RNC in Pool Node Redundancy
Log Type Before switchover After switchover
Log Type Before load sharing After load sharing
Reported by the master Reported by the new
Text log (famlog)
Reported by the Reported by the subsystem RNC master RNC
Text log (famlog)
master RNC that generates the log.
Binary log
Reported by the master Reported by the new
(CHR/DEBUG/Callfaul
RNC master RNC
t)
Reported by the subsystem
that generates the log. For Reported by the master Reported by the new
PCHR
example, logs generated by the RNC master RNC
Binary log
Reported by the NBM module are reported by
(CHR/DEBUG/Call Reported by the master Reported by the new
master RNC the master RNC, while logs MR
fault) RNC master RNC
generated by the RNCAP/CO
module are reported by the
overflow RNC.

Reported by the
PCHR Reported by the overflow RNC
master RNC

Reported by the
MR Reported by the overflow RNC
master RNC

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


RNC in Pool Load Sharing Traffic Statistics
On RNC in Pool Load Sharing
networks, the performance
counters of UEs who are
offloaded to other RNCs are not
only counted into the basic KPIs,
but also defined as new counters
for assessing the KPIs of loading
sharing UEs.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


Troubleshooting
Case 1: UEs for load sharing in Step 4: Check whether the UE accesses
the network by means of IMSI or TMSI.
IMSI-binding mode (ADD UIMSI)
are not offloaded.
Step 1: Check the switch and license
for RNC in Pool Load Sharing.

Step 2: Check for alarms


related to RNC in Pool.

Step 3: Check the user plane states of the Iu, Iub,


and Iur-p interfaces on the overflow RNC.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


Troubleshooting
Check the transmission status and check whether the overflow
RNC reports ALM-21392 Adjacent Node IP Address Ping Failure.
Case 2: The user plane load
sharing function is unavailable.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


Troubleshooting
Case 3: On an RNC in Pool Node
Redundancy network, cell
establishment fails after a NodeB
control switchover is performed.

Check whether the user-plane


configuration is correct on the NodeB side.

Check whether the user-plane


configuration is correct on the RNC side.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


Thank you
www.huawei.com

Copyright © 2016 Huawei Technologies Co., Ltd. All Rights Reserved.


The information in this document may contain predictive statements including, without limitation,
statements regarding the future financial and operating results, future product portfolio, new technology,
etc. There are a number of factors that could cause actual results and developments to differ materially
from those expressed or implied in the predictive statements. Therefore, such information is provided for
reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the
information at any time without notice.

You might also like