Analysis, Design &modelling of A Multi-Storey Commercial Building
Analysis, Design &modelling of A Multi-Storey Commercial Building
MULTI-STOREY COMMERCIAL
BUILDING
BY
M.SUDHEER
C.SWATHI REDDY
S.YASEEN
UNDER THE
GUIDANCE OF:
M.CHANDRAIAH
CONTENTS
Plan
Preliminary design
Analysis
Design
Modelling
MULTI STOREY COMMERCIAL BUILDING (G+4) PLAN
ALL DIMENSIONS ARE IN FEET’S AND INCHES
Column positioning
PRELIMINARY DESIGN
Calculations :
Thickness of slab:
Effective span:
Calculation:
Span of beam=3.05+2×0.3/2=3.35m
Grade of concrete=M20
Grade of steel=Fe415
Assume dimensions of the beam as 300mm×300mm
Effective area of slab coming onto the beam
=(1/2×3.35×1.675)×2
=5.611m2
Load calculations
Dead load of slab=0.12×25=3KN/m2
Live load on slab=4.0 KN/ m2
Floor finishes=1 KN/ m2
Total load=8 KN/ m2
Load transferred from slab to beam=8×5.611=44.9 KN
Self weight of beam=0.3×0.3×3.35×25=7.53 KN
Weight of wall on beam=0.3×3.35×3.5×18=63.315 KN
Total load = 44.97+7.53+63.315= 115.75 KN
Factored load =1.5×115.75=172.125 KN
Factored load acting on beam=172.125/3.35=51.38 KN/m
Maximum bending moment = (51.38×3.35×3.35)/10=57.66 KNm
Effective depth required=(M/ (0.138fckb))1/2
=(57.66 / (0.138×20×300) )1/2=263mm
Assume nominal cover =25mm
Assume diameter of bar =12mm
Provide overall depth of beam =263+25+6=294mm
Hence the dimensions of the beam are 300mm×300mm
PRELIMINARY DESIGN OF COLUMN
Calculation :
= (1.525+1.525) × (1.525+0.762)
=6.97 m 2
= (4×3.5×0.3×0.35×25)+(1×0.3×0.35×25)
=39.375 KN
=563.00KN ~ 565 KN
= (4×(28+13.95)) × (1-0.3)
=117.46 KN
=117.5 KN
Pu =0.4fckAc+0.67fyAsc
1142.67×1000=7.84Ag+5.561Ag
5.Place the R.F, Fixed end moments in the exact pattern for iterating moment
contributions also, displacement contributions if sway exists.
Thickness of slab:
Effective span:
Loads:
= 0.047×13.5×3.17 = 6.37KNm
2
=0.035×13.5×3.17 = 4.74KNm
2
= 0.035×13.5×3.17 = 6.37KNm
2
= (6.37×10 /0.138×20×1000)1/2
6
A = 150.96 mm
st
2
Consider least of it
1. 300 mm
2. 3d =3 x 120 =360mm
M=0.87×fy×A ×d(1-A ×fy/fck×b×d)
st st
A = 111.6 mm
st
2
Consider least of it
1. 300 mm
2. 3d =360mm
6.37×106=0.87×415×Ast×120[1-(Ast×415/20×1000×120)]
Consider least of it
1. 300 mm
2. 3d = 360mm
M=0.87×fy×A ×d(1-A ×fy/fck×b×d)
st st
A = 111.6 mm
st
2
Consider least of it
1. 300 mm
2. 3d = 360mm
3. 300 mm
V = W L / 2 =(13.5 × 3.17)/2=21.4 KN
u
From IS 456-2000
τC=0.28 N/mm 2
τC >
τv
P = A × 100/ bd = 0.1258
t st
REINFORCEMENT AT END A:
Where, ( Xu max/d)=0.48
M = 153.05 KN-m
u lim
M >M
u lim u
6
A
st provided = 4 x 201.06 = 804.24 mm 2
REINFORCEMENT AT END B:
Where,( Xu max/d)=0.48
M = 153.05 KN-m
u lim
M >M
u lim u
A = 131.74 mm
st
2
b = (4800/6)+(300)+(6 x 120)
f
b = 1820 mm
f
( Xu max/d)=0.48
( X /480)=0.48
u max
M = 0.36 x f x b x X (d – 0.42 X )
u ck f u u
A = 848.57 mm
st
2
a st = π/4 x 16 = 201.06 mm 2 2
SHEAR REINFORCEMENT :
V = W L / 2 =(57.895 × 4.8)/2=138.948 KN
u
From IS 456-2000
τC=0.566 N/mm 2
Assume 2 legged 8 mm dia vertical stirrups
A = 2 x π/4 x 8 = 100.5 mm
sv
2 2
Sv = 236.74 ~ 230mm
(i) 230mm
(iii) 300mm
In XX direction
In YY direction
In XX direction ,
Actual eccentricities are less than minimum eccentricity and eccentricities as per code
P = 0.4×f ×A +0.67 f A
u ck c y sc
A = 2042.88mm2
sc
= 2.39 % [0.8 - 4 %]
LATERAL TIES :
(ii) 6 mm
SPACING OF TIES :
2)16 times bar dia =16×20 =320mm [16 x diameter of the bar]
3)300mm
= 92.77 KN
Total load = W + W c f
= 927. 78 + 92.77
=1020.55KN
=1020.55/230
= 4.43m 2
=662.699(0.9-d)
= 596.42 - 662.699d
= 605.073(0.975-d) -(1)
= 672d -(2)
= τC. A
=perimeter x d
=((0.3+d) +(0.35+d)) d
=(0.65+2d) d
= 287.598KN-m
=268.39 KN-m
M =0.138 x f x b x d
u ck
2
d=222.75mm~0.225 m
d=0.575mm
=638 ~650 mm
287.598x 106=0.87x415xAstx592(1-415 Ast/2100x592x20)
=2484 mm2>1280mm2
Total reinforcement in shorter direction = 2/(B+1) where,B=y/x = 2.3/2.1 =1.0952 Reinforcement in central band/2484 = 2/(1.095+1)
= 2371.13mm2
balancing area of steel is to be distributed in the outer band
= 2100-300/2
=900mm >752.2mm
Hence Ok
Height of each floor = 3.5 m
Thread = 250 mm
=9 - 1= 8
=8 x 250 =2000mm
d =(M
req u lim /0.138 fck b) 1/2
= 11.22 mm ~ 105mm
=167.5 mm ~170mm
= 5.44KN/m
= ½ x 0.2x 0.25 x 25
=0.625 KN/m
= 2.5KN/m
=8.44 KN/m
= 5 x 1 = 5 KN/m
Ast = 594.94mm 2
Spacing Sv =( ( (π /4 ) x 12 ) /A ) x 1000
2
st
Sv =( ( (π /4 ) x 12 ) /594.94) x 1000
2
= 190.08mm ~ 190 mm
(i) 190mm
(ii) 450mm
DISTRIBUTION REINFORCEMENT
(i) 380mm
(ii) 450mm
Provide 10mm diameter bars at a distance of 380 mm centre to centre spacing for distribution reinforcement
Modelling
Creating a Model
The interior
view of the model
The Exterior view of the model
Thank
you