Timing and Control Unit
Timing and Control Unit
Dolly Trivedi 1
CPU is partitioned into Arithmetic Logic Unit
(ALU) and Control Unit (CU).
The function of control unit is to generate
relevant timing and control signals to all
operations in the computer.
It controls the flow of data between the
processor and memory and peripherals
Dolly Trivedi 2
The control unit directs the entire computer
system to carry out stored program instructions.
The control unit must communicate with both
the arithmetic logic unit (ALU) and main
memory.
The control unit instructs the arithmetic logic
unit that which logical or arithmetic operation is
to be performed.
The control unit co-ordinates the activities of
the other two units as well as all peripherals and
auxiliary storage devices linked to the computer.
Dolly Trivedi 3
Control unit generates control signals using
one of the two organizations:
Dolly Trivedi 4
It is implemented as logic circuits (gates,
flip-flops, decoders etc.) in the hardware.
This organization is very complicated if we
have a large control unit.
In this organization, if the design has to be
modified or changed, requires changes in the
wiring among the various components. Thus
the modification of all the combinational
circuits may be very difficult.
Dolly Trivedi 5
ADVANTAGES
Dolly Trivedi 6
DISADVANTAGES
More is the control signals required by CPU;
more complex will be the design of control
unit.
Modifications in control signal are very
difficult. That means it requires rearranging
of wires in the hardware circuit.
It is difficult to correct mistake in original
design or adding new feature in existing
design of control unit.
Dolly Trivedi 7
Dolly Trivedi 8
Control unit consist of a:
Instruction Register
Number of Control Logic Gates,
Two Decoders
4-bit Sequence Counter
Dolly Trivedi 9
An instruction read from memory is placed in
the instruction register (IR).
The instruction register is divided into three
parts: the I bit, operation code, and address
part.
First 12-bits (0-11) to specify an address,
next 3-bits specify the operation code
(opcode) field of the instruction and last left
most bit specify the addressing mode I. I = 0
for direct address I = 1 for indirect address
Dolly Trivedi 10
First 12-bits (0-11) are applied to the control
logic gates.
The operation code bits (12 – 14) are
decoded with a 3 x 8 decoder.
The eight outputs ( D0 through D7) from a
decoder goes to the control logic gates to
perform specific operation.
Last bit 15 is transferred to a I flip-flop
designated by symbol I.
Dolly Trivedi 11
The 4-bit sequence counter SC can count in
binary from 0 through 15.
The counter output is decoded into 16
timing pulses T0 through T15.
The sequence counter can be incremented by
INR input or clear by CLR input
synchronously.
Dolly Trivedi 12
For example: Consider the case where SC is
incremented to provide
timing signalsT0, T1, T 2 , T3, and T4 in
sequence. At time T4 , SC is cleared to 0 if
decoder output D3 is active. This is
expressed symbolically by the statement:
D3 T4 : SC ←0
The timing diagram shows the time
relationship of the control signals.
Dolly Trivedi 13
Dolly Trivedi 14
A micro-programmed control unit is
implemented using programming approach. A
sequence of micro operations are carried out
by executing a program consisting of micro-
instructions.
Dolly Trivedi 15
A micro-instruction consists of:
One or more micro-operations to be
executed.
Address of next microinstruction to be
executed.
Micro-Operations: The operations performed
on the data stored inside the registers are
called microoperations.
Micro-Programs: Microprogramming is the
concept for generating control signals using
programs. These programs are called micro-
programs.
Dolly Trivedi 16
Micro-Instructions: The instructions that
make micro-program are called micro-
instructions.
OR
Micro-Code: Micro-program is a group of
microinstructions. The micro-program can
also be termed as micro-code.
Dolly Trivedi 18
The micro-program control unit is slower
than hardwired control unit. That means to
execute an instruction in micro-program
control unit requires more time.
The micro-program control unit is expensive
than hardwired control unit in case of
limited hardware resources.
The design duration of micro-program
control unit is more than hardwired control
unit for smaller CPU.
Dolly Trivedi 19
Dolly Trivedi 20
The address of micro-instruction that is to be
executed is stored in the control address
register (CAR).
Micro-instruction corresponding to the
address stored in CAR is fetched from control
memory and is stored in the control data
register (CDR).
This micro-instruction contains control word
to execute one or more micro-operations.
After the execution of all micro-operations of
micro-instruction, the address of next micro-
instruction is located.
Dolly Trivedi 21
Dolly Trivedi 22