Dokumen - Tips - Zte ZXSDR Bts Structure and Principle
Dokumen - Tips - Zte ZXSDR Bts Structure and Principle
Agenda
CDMA2000 WiMAX
GSM
WCDMA TD-SCDMA
BBU BBU
Interface Interface
+ =
integrated solution for single-sector
cell.
B8200
RSU40/RSU60 BS8800
Indoor Marco BTS BS8800, can be
B8200
+ = installed in equipment room for indoor
coverage
RSU40/RSU60 BS8900
Outdoor Marco BTS BS8900, can be
installed in cabinet for outdoor
B8200
+ = coverage, it can adapt to various
environment
ZTE GSM/UMTS Dual-Mode SDR Family
Antenna BS8700
BBU
BB
(uBPG) CPRI
FS R8860
RadioUnit
Radio Unit Fiber
E1(75 SA/
Ω/120Ω SE CC
) / T1
GE/FE RRU
Control Signaling
Clock
Data
=
R8840
+ R8860
B8200
The
The structure
structure of
of BS8700
BS8700 can
can express
express in
in the
the form
form of
of
BBU+RRU,
BBU+RRU, with
with Base
Base band
band and
and RF
RF modules
modules separated.
separated.
ZXSDR B8200 Introduction
B8200 accomplishes the following basic functions
with RRU in Um/Uu, Abis/Iub and O&M interfaces.
RRU and B8200 accomplishes UE access and radio link transmission
including RF processing, channel coding and decoding, channel
multiplexing and de-multiplexing, measuring and reporting, power
control, transmit diversity, receiving diversity, calibration and
synchronization.
With Abis/Iub interface, RRU and B8200 connects with BSC/RNC and
accomplishes the following functions including cell management,
reporting BTS measurement information, broadcasting system
Information, implementing access control from BSC/RNC, mobility
management, radio resource management and controlling, FP
processing and transmission management.
With operating and maintenance interface, B8200 provides system
management functions including configuration management, alarm
management, status checking and system monitoring
Base Band Unit - ZXSDR B8200
Performance Index
GSM Processing Capability:
19 inch 60TRX (12TRX *5uBPGs )
24 Cell / BBU
UMTS Processing Capability:
2U
88.4mm 960CE/BBU(192CE/BPC*5)
Throughput UL 75Mbps(15Mbps*5)
482.6mm Throughput DL 216Mbps(43.2Mbps*5)
30CS/BBU
Based on Unified MicroTCA Platform
Physical Index
Interface Index Volume:
88.4×482.6×197mm ( H×W×D )
Abis/Iub Interface: Weight: 8.75kg (full configuration)
16*E1/T1 ; Typical Power Consumption :
1*FE/GE Electric/Optical(8 VLAN) GSM 60W/12TRX
WCDMA 80W / 6CS
To RRU: 12*1.25Gbps CPRI optical interface
Power Supply: -48V DC
Temperature Range: -20℃ ~ 55℃
Humidity Range: 5% ~ 95%
PM Board Introduction
Power Module
Power Module
16 internal interface for +12V load power
16 internal interface for +3.3V management power
Measurement and protection of input over-voltage/under-
voltage;
Output over-current protection and load power management
PM Indicators
Board LED Color Meaning Description
Always on: The board is in reset state.
Running
RUN Green Flashing at 1Hz: The board is normally running.
Indicator
Off: Self test fails.
On: The board has an alarm.
Alarm Red Alarm Indicator
PM Off: The board has no alarm.
On: The board can be unplugged.
Plugging/Unplug Flashing: The board is being activated or
HS Blue
ging Indicator deactivated.
Off: The board cannot be unplugged.
SA/SE Board Introduction
Providing 6 input dry contact interfaces, 2 input /output dry contact interface;
TWO MSB
TWO MSB POSITIONS
POSITIONS OF
OF X5
X5
CC Board Introduction
Control & Clock Board
Ethernet switch function, providing switch plan for signaling and media stream;
Rack management
CC Indicators
Board LED Color Meaning Description
On: The board can be unplugged.
Plugging/Unpluggin
HS Blue Flashing: The board is being activated or deactivated.
g Indicator
Off: The board cannot be unplugged.
Always on: The board is in reset state.
RUN Green Running Indicator Flashing at 1Hz: The board is normally running.
Off: Self test fails.
On: The board has an alarm.
Alarm Red Alarm Indicator
Off: The board has no alarm.
Alternate flash for different links; the max 4 flashes per
CC second; flashing at frequency of 5 Hz.
The first second: one flash means Link 0 is normal and
OFF means Link 0 is not in use.
The third second: two flashes means Link 1 is normal
E1/T1 status and OFF means Link 1 is not in use.
E0S Green
indicator (link 0–3) The fifth second: three flashes means Link 2 is normal
and OFF means Link 2 is not in use.
The seventh second: four flashes means Link 3 is
normal.
and OFF means Link 3 is not in use.
Recycle. Each cycle lasts for eight seconds.
CC Indicators
Board LED Color Meaning Description
E1/T1 status
E1S Green The same as E0S.
indicator (link 4–7)
E1/T1 status
E2S Green The same as E0S.
indicator (link 8–11)
E1/T1 status
E3S Green indicator (link 12– The same as E0S.
15)
Active/Standby On: The board is in active status
MS Green
status indicator Off: The board is in standby status
500mm
GSM -113dBm@sigle antenna
UMTS
-126.5dBm@sigle antenna
-129.2dBm@dual antenna
17
2m
m 320m
m Frequency:
900MHz, 1800MHz, 850MHz, 1900MHz
SDR R8860
Physical Index
• 35 % power-efficient for GSM
Volume(R8860): 500×320×172mm ( H×W×D )
• 40% power-efficient for UMTS . Weight: 22.5Kg
• Support GSM and UMTS. Typical Power Consumption:200W (6TRX)(900M)
Power Supply: -48V DC
5 DC IN Power interface
Chain Topology
STM-1
B8200
BSC
E1/T1
ZTE
ZTEprovides
providesflexible
flexiblenetworking
networkingfor
fordistributed
distributedsite
sitesuch
suchas
asstar,
star,
chain,
chain,loop
loopand
andmix
mixtopology
topologyto
tomeet
meetdemands
demandsforforcustomers.
customers.
Agenda
Physical
PhysicalIndex
Index
Interface
InterfaceIndex
Index Volume: 950×600×450mm ( H×W×D )
Iub Interface: Volume: 950×600×450mm ( H×W×D )
Iub Interface:
(Main
(MainCabinet)
Cabinet)
8*E1/T1(Can expand to 16)
8*E1/T1(Can expand to 16) Weight: 135kg (Main Cabinet)
Weight: 135kg (Main Cabinet)
1*GE/FE Optical or 1*GE/FE Electrical
1*GE/FE Optical or 1*GE/FE Electrical Typical Power Consumption S666:735W(RSU60)
Typical Power Consumption S666:735W(RSU60)
To RRU: 12 *1.25Gbps CPRI Optical Interface
To RRU: 12 *1.25Gbps CPRI Optical Interface Power Supply: -48V DC (-40~-57V DC)
Power Supply: -48V DC (-40~-57V DC)
Radio Unit of BS8800
- RSU40/RSU60 Feeder Interface
RX expand
Numbe interface
Interface Interface Description
r
1 Power Power supply interface
2 AISG AISG device interface
3 Mon External device interface
4、5 Test 、 DBG Debug, test interface
Interface between BBU and
6 TX RX
RRU or RRU cascade
7 RXout 、 RXin Frequency expand interface
Main and diversity antenna
8 ANT
interface
RSU Modules Name in
BS8800/BS8900/BS8906
37
BS8800 Hardware Structure
Radio Unit:
RSU40,RSU60
Wiring Duct:
Used to walk wiring in rack, such
Transmission Device:
Wiring
950mm 1U slot, it can provide built-in
Duct
Fan transmission or microwave devices
Transmission
Device to save operators’ investment.
Ventilation
Base Band Unit:
Base Band 2*B8200 can be placed in
maximum
FAN
Used to perform heat dissipation
450 mm for RSU modules, 6 fans in total
600mm
38
BS8800 - Easy to Stack, Easy to expand
Radio Unit
Cable Chute
950mm
Power Distribution
Module 950mm
Ventilation
43
Cabinet Appearance
supporting cabinet + battery cabinet and radio cabinet
RC8910 RC8911
Radio Cabinet Radio Cabinet
RC8931
Radio Cabinet Outdoor Radio Cabinets
BC8910
Power & Battery Cabinets Supporting
PC8910 cabinet
Battery Cabinet
BC8910 Structure
AC Supply
AC Supply DC Supply
DC Supply
BBU 2U BBU 2U
Wiring Duct 1U
PDM 3U
RC8911&RC8910 Structure
RC8911
RC8911 RC8910
RC8910
Fan subrack
Fan subrack
PDM PDM
RU RU
Base Base
RC8931&PC8910 Structure
RC8931
RC8931
Fan subrack
PC8910
PC8910
PDM
RU
Storage battery
Storage battery
Base
Base
AC Configuration:BC8910+RC8911+RC8931
BC8910
Site support cabinet BC8910: used to
Outdoor RF cabinet RC8931: accommodate power system, baseband pool unit,
used to accommodate RF unit heat exchanger, and transmission device.
and battery. RC8931
Heat
Fan
Exchanger
subrack
6U reserved
space
PDM
BBU
RU B121
Fan
subrack
Storage
battery
Storage PDM
battery
RC8911 RU
6U reserved
BC8910 space
BBU
Storage
battery B121
Fan Fan
subrack subrack
PDM
PDM
RU
RU
6U reserved
space
BC8910
BBU
R8860
B121
Storage
PC8910 battery
DC Standard Configuration:BC8910+nRC8910
n=1~3
Heat
BC8910 Exchanger
BBU
Fan
subrack
PDM
RU
RC8910
Multi-form, Minimal Requirement for Site Condition
2 Place cabinets side by side
1 High Integration
Same size, volume and space for
all cabinets
Built-in transmission,
Suitable for these scenarios such as
battery, power supply
ground-bearer or limited height
configuration
52
Agenda
Interface
InterfaceIndex
Index Physical
PhysicalIndex
Index
Iub Interface: Volume: 600 × 320 × 480 mm ( H×W×D )
Iub Interface: Volume: 600 × 320 × 480 mm ( H×W×D )
8*E1/T1(Can expand to 16) Weight: 52kg
8*E1/T1(Can expand to 16) Weight: 52kg
1*GE/FE Optical or 1*GE/FE Electrical Typical Power Consumption S4: 300W (RSU60)
1*GE/FE Optical or 1*GE/FE Electrical Typical Power Consumption S4: 300W (RSU60)
To RRU: 12 *1.25Gbps CPRI Optical Interface Power Supply: -48V DC (-40~-57V DC)
To RRU: 12 *1.25Gbps CPRI Optical Interface Power Supply: -48V DC (-40~-57V DC)
RSU subrack:
BS8906 Structure
RSU40,RSU60
BBU subrack:
1*B8200 can be placed in
FCE maximum.
RSU subrack FCE:
Detects the external and internal
maximum
APM+PSU/DPM
DPM (DC Protection Module)
SDH/Microwave IDU
Agenda
BBU
GE CC
FAM FS GE
IQ switching Abis/Iub
switching
Clock SA
IQ E1/T1
PM GE
GE/FE BSC/RNC
UBPG / BPC
Fiber
RRU
Software Architecture
G SM Function UMTS Function
OSS
OMC -B
VOS
VxWorks
Windows
Hardware (BSP)
Software Architecture
The operating support layer provides the functions of OSS, OAM, DBS, BRS, BRACS, and
SCS to serve to different BTS mode.
OAM (Operating and Maintenance) is to provide the configuration, alarm and
BRACS (Barrier Access Control Sub-system) is to control the access to bear layer.
active/standby switching.
OSS (Operation Support Sub-system) is the support layer in this entire framework, which
is a hardware irrespective platform for running software and provides basic functions like
scheduling, timer, memory management, communication, sequencing control, monitoring,
alarming and logging. Detects the external and internal environment temperature in real
time.
BSP (Board Support Package) supports the information routing to the GSM and public
parts in the application layer.
VxWorks is the operation platform communication to the hardware components.
Agenda
LAN
R
RAN CN
Local client
LMT LMT
WAN
Remote R R
LAN
RAN CN
Remote client Remote client
LMT
LMT (via internet) Internet
Maintenance Functions
NMS/OSS/
BSS 3rd Party
NMS/OSS/BSS
Northbound
Interface
Log Security
Management Management
NE
FM PM CM IM SM FM PM CM IM SM
NE (RAN) NE (CN)
Maintenance Functions
The BSS provides a transparent channel to implement operation and maintenance
information interaction between NetNumen M31 and the BTS. Management of the BSC
and the BTS adopts unified client interface for unified security management and operation
log. And it has a unified service management interface. NetNumen M31 also supports
CORBA/SNMP Itf-N interface to be integrated with third-part NMS.
Version Management
Version Management
With this function, users can check the versions of the software and hardware running at
the foreground. The background provides a software downloading system for software
upgrade at the foreground. Before downloading, warehousing processing is required, that
is, copying the version file to the server and registering to the server.
Fault Management
Fault Management
With this function, users can check the versions of the software and hardware running at
the foreground. The background provides a software downloading system for software
upgrade at the foreground. Before downloading, warehousing processing is required, that
is, copying the version file to the server and registering to the server.
Maintenance Functions
Configuration Management
Configuration Management
Performance Management
Performance Management
Log Management
Log Management
Security Management
Security Management