Case Study Hospital
Case Study Hospital
PRESENTED TO – PRESENTED BY –
AR. KUMAR ABHISHEK MEGHA SINGH
INTRODUCTION
A hospital is a health care institution providing patient treatment by specialised staff and
equipment.
PROJECT PROFILE:
Address: Guru Nanak Dev Charitable Hospital,
Tarn-Taran,
Plot Area:Punjab.
1,59,400 Sq. ft Started in: 2008
Architect: Ar.D.P Singh (Ludhiana).
ABOUT:
It is built in 1,59,400 area. This is the 250 bedded fully
computerised
charitable hospital. Services provided in the IT INCLUDES:
hospital by the services block built near the hospital Emergency department
IPD(Inpatient Department)
LOCATION:
OPD(Outpatient Departme.
It is bounded by Amritsar district
north,Kaputhala distric.
SERVICE CONSULTANTS
in east, Pakistan in the west and Ferozepur district
in the south. Electrical: Samit
SITE LOCATION: HVAC: Ambience,chd
It is 18 km away from the Amritsar Fire Fighting: Cascade.
The. site is very much near to Goindwal sahib road,
city
EMERGENCY ENTRANCE
EMERGENCY
WING
RECEPTION DESK
Fire escape
EMERGENCY ENTRANCE
FIRST FLOOR PLAN
•Strong Connectivity of O.T – gynaecology BLOOD BANK
dept.– ward and rooms
•Dirty utility is first washed and semi sterilization
is done near O.T then it is transferred to C.S.S.D
through Service lifts. MOTHER RECOVERY
CENTRE
•Blood bank is provided on the first floor. NATAL WARDS
•Access to gynae dptt. Is through lift.
BIO-CHEM. DEPT.
BIRTHING CENTRE
ADMIN. BLOCK
BIRTHING CENTRE
INFERENCES:
SCRUB AREA
ENTRY • No direct access to the scrub
area from the changing room.
CHANGING ROOM SUB STERILE AREA • O.t.2 z not provided with
double cavity walls.
• C.U. & D.U. are provided for
recovery room and eclampsia.
NURSE STATION O.T • No shoot shafts & dirty
. corridors attached to o.t. area
for waste disposal.
• Corridor width 8ft
RECOVERY ROOM
Gynae and Maternal ward
KEY PLAN
Delivery room
O.T
• WARDS AND POST NATAL ROOMS ARE .
PROVIDED….NEAR THE N.I.C.U.
INCUBATO
R
SECOND FLOOR
MEDICAL I.C.U.
C.S.S.D.
Placed very next to the O.T. so as the easy
transfer of the sterile equipment.
O.T
.
VERTICAL CIRCULATION
1 MAIN STAIR CASE IS PROVIDED.
VERTIACL CIRCULATION IS THROGH RAMP AND IT ALSO
BECAME THE ELEVATION FEATURE.
RAMP,FIRE EXITS ARE UPTO FOURTH FLOOR.
FOR THE TOP FLOOR,MAIN STAIRS AND 4 LIFTS ARE
PROVIDED.
2VISITORS LIFTS,2 PATIENTS LIFTS AND 1 SERVICE LIFT
ARE PROVIDED.
PRIVATE ROOMS
laundry
BASEMENTS
CT SCANAND MRI IS PROVIDED IN THE UPPER BASEMENT
PARKING IS PROVIDED LEAVING 30’ SPACE FROM THE SCAN
AREA BECAUSE HARMFUL RADIATIONS ARE EMITTED IN THAT
ZONE.
• SLOPE-1’-0”:10’-0”
•RAMP 22’ WIDE.
LOWER BASEMENT PLAN
CIRCULATIO
N
RAMP
LIFTS (NORMAL/STRETCHER)
FIRE EXITS (STAIRS)
FIRE STAICASE 5’0” WIDE
STAIRCASE IS PROVIDED WITH
BOTH SIDE RAILING
KEY PLAN
VERTICAL CIRCULATION
1 MAIN STAIR CASE IS PROVIDED.
VERTIACL CIRCULATION IS THROGH RAMP AND IT ALSO BECAME THE ELEVATION FEATURE.
RAMP,FIRE EXITS ARE UPTO FOURTH FLOOR.
FOR THE TOP FLOOR,MAIN STAIRS AND 4 LIFTS ARE PROVIDED.
2 VISITORS LIFTS,2 PATIENTS LIFTS AND 1 SERVICE LIFT ARE PROVIDED.