C07 WCDMA RNO Access Failure Problem Analysis
C07 WCDMA RNO Access Failure Problem Analysis
Review
Case study
Definition of access failure
Case study
Access problem analysis process
methods
Preparation before analysis
Be familiar with the planning information which can be obtained from planning
reports;
Obtain the network traffic statistics and the subscriber complaint information of
access.
Access problem analysis process
methods
Access problem analysis methods
General methods of access problem analysis:
Coverage analysis
Signaling analysis
Access problem analysis methods
Case study
Common reasons for access problems
RF reasons
Other reasons
RF reasons
Poor coverage
RF reasons
Other reasons
Radio parameter settings
RF reasons
Other reasons
Other reasons
Case study
Case study
UE Txpower reaches maximum value 21 dBm during VP call setup. So this call
setup failure may be caused by Uplink synchronization failure:
Access failure due to synchronization failure
UE does not send RRC Connection Setup Complete to RNC after receiving RRC
UE report the measurement of cell Sc508 which request the active set update:
Access failure during handover process
The report was
received properly and
“RRC_ACTIVE_UPDATE”
was sent as response
while UE didn’t received it
which results in the
access failure:
Access failure during handover process
Let’s turn to the performance of the terminating UE. During the access process,
the measurements from the terminating UE were not satisfactory either:
Access failure during handover process
Access failure during handover process
While the radio links
hold on till successful
handover is completed:
Access failure during handover process
Then the originating UE loses connection to the network and access released
where the cause is “destination out of order” from the signal traced by the
terminating UE:
Case study