Simovert
Simovert
DA-1-221101
Siemens SIMOVERT MasterDrives
Contents
1. Inverters
2. Rectifier Regeneration Unit
3. Optional boards
4. Replacing components
DA-2-221101
Siemens SIMOVERT MasterDrives
Speed of an AC motors
DA-3-221101
Siemens SIMOVERT MasterDrives
DA-4-221101
Siemens SIMOVERT MasterDrives
DA-5-221101
Siemens SIMOVERT MasterDrives
Inter-
Rectifier mediatec Inverter
ircuit M
DA-6-221101
Siemens SIMOVERT MasterDrives
Inter-
Rectifier mediatec Inverter
ircuit M
DA-7-221101
Siemens SIMOVERT MasterDrives
Usual connection
3x380 V
50 Hz
The common rectifier is
suitable for connecting
several inverters to a
R e c t ifie r common DC bus. This
permits the exchange of
energy between motoring
C o m m o n D C lin k and generating drives, and
P
thus saves energy.
N
In v e r te rs
M M M M M
~ ~ ~ ~ ~
DA-8-221101
Siemens SIMOVERT MasterDrives
DA-9-221101
Siemens SIMOVERT MasterDrives
DA-10-221101
Siemens SIMOVERT MasterDrives
Gating signals over time for the two inverter phases L1, L2 and the
associated phase to phase output voltage. The magnitude of the voltage
pulses corresponds to the DC link voltage
DA-11-221101
Siemens SIMOVERT MasterDrives
Inverter external
DC link supply
OP1S
Inverter
USS
PROFIBUS
Motor
Encoder
DA-12-221101
Siemens SIMOVERT MasterDrives
Digital inputs
and outputs
Analog inputs
and outputs
DA-13-221101
sensor
Siemens SIMOVERT MasterDrives
Parameters
Parameter Parameter Parameter Parameter Dimension
name number index value
Free blocks
DA-14-221101
Siemens SIMOVERT MasterDrives
Data Sets
DA-15-221101
Siemens SIMOVERT MasterDrives
Changing Datasets
P577 P579
0 1 0 1
P590
0 1
0 FDS1 FDS3 0 MDS1 MDS3
P576 P578 BDS BDS
1 FDS2 FDS4 1 MDS2 MDS4 1 2
DA-16-221101
Siemens SIMOVERT MasterDrives
M(set,n-Reg.)
n(set,smooth)
K0153
KK0150
DA-17-221101
KK Connector with double-word length (32 bit, increased accuracy)
Siemens SIMOVERT MasterDrives
Binector
name
Accel active
B0201
Identification Binector
letter number
DA-18-221101
Siemens SIMOVERT MasterDrives
BICO system
Selecting setpoint with wires: Selecting setpoint with parameterization:
10 V
MOP Setpoint from
KK0058 Connector
0V MOP
!
10 V
P443
Fixed Fixed
U221
DIN 2 DIN 2 B0012 .01
& B
.02
DIN 3 DIN 3 B0014 B
.03 &
B
DIN 4 DIN 4 B0016
Integrated Free block
DIN 5 AND gate DIN 5 B0018
!
DIN 6 DIN 6 B0020 Binectors
DA-19-221101
U221.02 = 0014
U221.03 = 0020
U950.78 = 4 (time slot)
Siemens SIMOVERT MasterDrives
BICO Datasets
Hardware Software
CUVC
DA-20-221101
Siemens SIMOVERT MasterDrives
BICO Dataset 1
P554.01=B3001 ON/OFF1
Remote mode
P565.01=B3007 Fault Reset
=0
P590 BICO Dataset 2
=1 P554.02=B2001 ON/OFF1
Local mode
P565.02=B2007 Fault Reset
DA-21-221101
Siemens SIMOVERT MasterDrives
Parameterazing methods
PMU Panel Parameters copy: Backup of data:
1.
<
O P
<
Manually create
OP1S Panel Download
2. 7 8 9
4 5 6
1 2 3
0
7 8 9
4 5 6
1 2 3
I 0
7 8 9 7 8 9
4 5 6 4 5 6
O 1 2 3 1 2 3
1
5
2
6
3
Upread
0
3. PC with SIMOVIS
Download
DA-22-221101
Siemens SIMOVERT MasterDrives
Raise/lower to select:
Switch-on Parameters
Switch-off Indices
Parameter values
Fault acknowledgement
and changeover between:
Parameter number
Parameter index
DA-23-221101
Parameter value
Siemens SIMOVERT MasterDrives
PMU - Display
Example:
Operating status: from 0 to 21
Operating status º009
Parameter r001
Actual frequency 16.47
Fault F035
The most important statuses:
Parameter number P800
008 Start inhibit
Parameter index .001
009 Ready for ON
Parameter value 50.00
011 Ready for operation
014 Operation
DA-24-221101
Siemens SIMOVERT MasterDrives
DA-25-221101
Siemens SIMOVERT MasterDrives
DA-26-221101
Siemens SIMOVERT MasterDrives
The OP1S has a non- volatile memory and can permanently store complete sets of
parameters. It can therefore be used for archiving sets of parameters but, first, the
parameter sets must be read out (upread) from the units. Stored parameter sets can also be
transferred (downloaded) to other units.
The OP1S and the units to be operated communicate with each other via a serial interface
(RS485) using the USS protocol.
The OP1S can be operated at baud rates of 9.6 kBd and 19.2 kBd and is capable of
communicating with up to 32 slaves (addresses 0 to 31). It can therefore be used in a point-
to- point link (e. g. during initial parameterization) or within a bus configuration.
The plain- text displays can be shown in one of five different languages (German, English,
Spanish, French, Italian). The language is chosen by selecting the relevant parameter for
the slave in question.
DA-27-221101
Siemens SIMOVERT MasterDrives
Displayed Number to be
number keyed in on OP1S
DA-28-221101
Siemens SIMOVERT MasterDrives
DA-29-221101
Siemens SIMOVERT MasterDrives
Control word 1
Parameter Bit Command
No.
P554 0 ON/OFF 1 command; 1=ON, 0=OFF1
DA-30-221101
Parameter value shows the source of the command!
Siemens SIMOVERT MasterDrives
Control word 1
Parameter Bit Command
No.
P568 8 Inching 1 ON command
DA-31-221101
Siemens SIMOVERT MasterDrives
Control word 2
Parameter Bit Command
No.
P576 16 Function data set FDS bit 0 command
DA-32-221101
Siemens SIMOVERT MasterDrives
Control word 2
Parameter Bit Command
No.
P84 24 Droop/technology controller enable command
DA-33-221101
Siemens SIMOVERT MasterDrives
Pause
DA-34-221101
Siemens SIMOVERT MasterDrives
-X101
P24
1
+24 V
3
MOTOR FAN CONTROL
4
BRAKE CONTROL
5
LOCAL
7
MAIN CONTACTOR
8
CONVERTER FAN FAULT
9
EMERGANCY FAST STOP
DA-35-221101
Siemens SIMOVERT MasterDrives
DA-36-221101
Siemens SIMOVERT MasterDrives
ON/OFF1 P554=2100
DA-37-221101
Siemens SIMOVERT MasterDrives
DA-38-221101
Siemens SIMOVERT MasterDrives
DA-39-221101
Siemens SIMOVERT MasterDrives
DA-40-221101
Siemens SIMOVERT MasterDrives
DA-41-221101