According to the document: - Dropped object incidents from January to March 2011 included 14 total incidents, with most occurring during rig and well operations (12) and crane and lifting operations (2). - Notable rig and well incidents involved a diverter and extension detaching and falling 50 feet, a cover detaching and falling 70 feet, and an annular packer striking an anode and falling 9 meters. - Crane and lifting incidents included wooden sheathing detaching from a crane boom and falling and a valve actuator detaching and falling 30 inches. - Other incidents involved lengths of pipe and an emergency beacon detaching and falling.

Uploaded by

egy pure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views

HSE Dropped Objects

According to the document: - Dropped object incidents from January to March 2011 included 14 total incidents, with most occurring during rig and well operations (12) and crane and lifting operations (2). - Notable rig and well incidents involved a diverter and extension detaching and falling 50 feet, a cover detaching and falling 70 feet, and an annular packer striking an anode and falling 9 meters. - Crane and lifting incidents included wooden sheathing detaching from a crane boom and falling and a valve actuator detaching and falling 30 inches. - Other incidents involved lengths of pipe and an emergency beacon detaching and falling.

Uploaded by

egy pure
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 10

Health

Healthand
andSafety
Safety
Executive
Executive

Dropped Objects Update


January to March 2011
Donald Dobson
Health & Safety Executive
Offshore Division
Dropped objects – quarterly totals

40
35
30
25
20
15
10
5
0
Q3 - Q1 - Q3 - Q1 - Q3 - Q1 -
2008 2009 2009 2010 2010 2011
2011 January to March - All Incidents

14

12

10

0
Rig & Well Ops Crane & Lifting Other
Derrick & Well Ops Incidents

2.5
Pipe handling
Derrick fitting
2
Tubular
Personal
1.5
Lifting Equip
1 Drilling equip
Wireline
0.5 Other

0
Derrick & Well Ops Incidents

• Lifting diverter through rotary, overshot +


extension (4.5 MT) detached and fell 50ft to
jacket deck
• Cover for top drive junction box (5kg) detached
during jarring & fell 70ft to rig floor – sheared
bolts
• Lifting out annular packer (680 kg) from LMRP it
struck an anode and fell 9m to deck
• Sledge hammer fell 40ft to rig floor; ring on end
of tool lanyard failed
• Picking up wire-line valve (130kg) to run into
well, it detached from running tool & fell 4.3m to
rig floor
Crane & Lifting Operations

2.5

2
Crane failure
Load
1.5
Collision
1 Unsecured item

0.5

0
Crane & Lifting Operations

• Wooden sheathing from crane boom rest


dislodged & fell to off-load hose walkway
• Lifting valve from WI filter package,
actuator detached and fell 30” to grating
below (corrode bolts)
Other dropped objects

5
Fittings
4 Unsecured
Personal
3

0
Other Dropped Objects

• Two lengths of redundant deluge pipe-work (7kg


& 2kg) detached and fell 6m to walkway
• Emergency beacon (10kg) detached from
bracket, falling 2.5m to extent of electric cable
• Hammer head (1.8kg) detached and fell 13m
during rope access work on crane boom
• Valve being manoeuvred struck second valve
which slipped under handrail & fell into sea