0% found this document useful (0 votes)
489 views

Cleaning Validation: Eun-Sook Gi April 12, 2004

This document provides an overview of cleaning validation. It discusses regulatory requirements for cleaning validation from the FDA and other sources. It covers topics such as developing a master validation plan, preliminary studies like coupon studies, developing effective cleaning processes and procedures, adequate sampling methods, acceptable criteria, and allowable contaminant limits. The goal of cleaning validation is to ensure product purity, safety, and quality by preventing cross-contamination and residual materials from remaining.

Uploaded by

wkm782
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
489 views

Cleaning Validation: Eun-Sook Gi April 12, 2004

This document provides an overview of cleaning validation. It discusses regulatory requirements for cleaning validation from the FDA and other sources. It covers topics such as developing a master validation plan, preliminary studies like coupon studies, developing effective cleaning processes and procedures, adequate sampling methods, acceptable criteria, and allowable contaminant limits. The goal of cleaning validation is to ensure product purity, safety, and quality by preventing cross-contamination and residual materials from remaining.

Uploaded by

wkm782
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 35

Cleaning Validation

Eun-Sook Gi
April 12, 2004

㈜ 삼양제넥스 생명공학
연구소
Regulatory and Requirements
FDA, July 1993
Guide to inspection for validation of cleaning
process

Application
regulation and requirements:
21CFR 211.65, 21CFR 211.67

Written cleaning procedure,21 CFR 211.182


Reference
 Cleaning and cleaning validation: A biotechnology pe
rspective, pub PDA, 1996
 www. cleaningvalidation.com
 Guidance on aspects of cleaning validation in active p
harmaceutical ingredient plants, APIC, 2000

 1) Cleaning validation an exclusive publication,


2) J of validation technology: Cleaning validation II
pub by Inst. of Validation Technology
Cleaning Validation Overview
 목적 :
Product: purity, safety, efficacy, quality 유지
Product:cross contamination, previous residual produc
t, microbial residue, detergent, degradant 잔류 방지

 언제 Cleaning validation 실시 ?
New equipment/product
Changed : 생산 process, cleaning process, 세척제
Changed : major component
Cleaning validation Overview
 Good system design
 Master validation plan
 Preliminary study
- Coupon study
- Cycle Development study
- Continuous data monitoring
- Justifiable acceptance criteria
 Effective cleaning process development
 Adequate analytical technique
Master Validation Plan
 Appropriate cleaning procedure
 Identification of cleaning agent
 Description of sampling procedure
 Acceptance criteria
 Analytical method
 A copy of protocol and final report
 A list of equipment
 Manufacturing process( a flow diagram)
Master Validation Plan
 CIP or COP
 Equipment matrix for CV
 Description of equipment and its location
 Surface area of equipment
 Average batch size of each equipment
 Training program for production and analytical personnel
 Reference to the company’s change control program
Sampling Procedure
 Sampling SOP
 Rinse or swab(surface) sampling
 Rinse sampling: volume, valve define
 Swab sampling: map of each equipment
the most-difficult-to-clean, easy-to-clean
“Easy-to-clean”: cleaning failure 확인
Sampling Location for Swab

N
o D
es
cri
pti
on Sa
mp
li
ngt
i
m e 1
2
1 1
번 I
mpel
ler상
1
1
2 2
번 I
mpe
l
le
r상
3 2
번 I
mpe
l
le
r하 1
0
4 S
ha
f
t
6
5 벽
면1 6
6 벽
면2
7 S
pa
r
ge
r하 4

8 P
0
1va
l
ve부위 3 2
5
9 S
pa
r
ge
r상
1
1
0 배
양액
경계
벽면 9
1
1 P
0
9l
ine옆벽
면 7 8
1
2 발
효조
상부 P0 1
Product/Cleaning Agent 관계
 Molecular structure (Bio product or small
molecule)
 Prod related compound
 Solubility: in water or in org. solvent?
 Reactivity
 Contaminant: Fluid or Solid?
 Cleaning agent selection
Coupon Study
 Coupon: Equipment 와 동일 surface type SUS or
Glass (5 x 5 cm, 10 x10 cm)
 Swab: polyester
 Characterization of residue
 Worst case of cleaning condition
 Selection of cleaner visually clean
 Cleaning condition 설정 : temp. range, cleaning
agent conc., pressure(agitation, shaking), rinse
volume visual inspection
Swab Test / Swab Recovery
 Swab method: sample, control and blank test

 Spiking of known quantity of analyte/residue


 Swab recovery test (70~130%)  recovery factor
 CV 실시 시 반영
 Estimation of swab sample solution stability
 Estimation of swab extraction time
 Residue limit TOC/prod specific
Cycle Development Study
 Performed prior to process validation
 Characteristic of residuals
 Cleaning agent select and concentration
 Rinse cycle time and volume
 Cleaning agent temperature
 CIP-Pressure (Turbulence)
 Cleaning procedure development
 Cleaning-SOP change or improve
 Continuous data monitoring Acceptance limit
 Operator training 및 training report
Cleaning SOP
Cleaning procedure development (SOP 정량화 )

 Pre-rinse: volume, pressure


 Soaking: alkaline/acid, organic solvent or other
detergent volume, temperature, soaking time
 Rinse recycle: time, temperature
 Rinse volume, pressure end point
 Final rinse volume, pressureend point
 End point 측정 : conductivity, pH
Equipment Validation
CIP 설비의 validation status 확인

 IQ: requirement of safety, utility, installation and documentation,


accuracy of P&ID etc.

 OQ: Test of flow rate, volume of washes and rinses,


temperature(inlet/outlet), turbulence, heating time of cleaning solution,
gas flow, purges
Spray ball: coverage study
Coverage Study (CIP)

Milk powder visual


Rivoflavin UV detection
Pressure
Visual detection
Photo documentation

P01
Equipment System Design
Consideration of CIP system for effective
cleaning
 Piping size 와 구조 (slope)
 Potential dead leg
 Turbulence of CIP solution
 Nozzle design: locate seal near vessel wall
 Branch piping
Instrument Tees
 Instrument Tee for CIP: L/D <1.5

L D

Bad Good Best

 Adequate turbulence (Flow rate) for CIP

½ ft/sec 5 ft/sec 5 ft/sec

<Cleaning and cleaning validation: A biotechnology perspective, pub PDA, 1996>


Dead Leg Orientation
 Branch piping : horizontal

Vertical up
Bad design
Vertical down

horizontal Good Design

<Cleaning and cleaning validation: A biotechnology perspective, pub PDA, 1996>


Recommended Drain Line Size
 Drain line: locate vessel drain high enough to slop
e down to CIP return pump
- 100L tank: 1.0 inch
- 1,000L tank: 1.5 inch
- 10,000L tank: 2.0 inch

 Sampling valve: Diaphram valve


 Design: CIP visually 확인 가능한 설계
 Cleaning and cleaning validation: A
Acceptance Criteria
 Visually clean
 Cleaning capability
 Sample test time limit
 Cleaning time limit: DEHT, CEHT
 Number of batches: 3consecutive batch
 Deviation handling
 Allowed contaminant limit
- General limit
- Maximum daily dose
- Toxicity based carry over
Allowable Contaminant Limit
 General ppm Limit:toxicological data for intermediate are
not known, API product 에 적용

MACOppm= MAXCONC x MBS

 MACOppm: maximum allowable carry over from previou


s product, calculated from general ppm limit
 MAXCONC:general limit for maximum allowed concentr
ation of “previous” substance to next batch
 MBS: Minimum batch size for the next product
Allowable Contaminant Limit
General ppm limit
 MAXCONC is often set to 5~100ppm depending on toxicity and ph
armacological activity

 MAXCONC for API : 10ppm is very frequent

 계산 예 : MBS of next product: 200kg

MACOppm= 0.00001(mg/mg) x 200 000 000 (mg)


= 2000 (mg)

<Ref: APIC 2000: cleaning validation guidance>


Allowable Contaminant Limit
General limit (10ppm carry over) for swab area
10mg/kg x MBS(kg)/equipment surface area x Swab area

Identity No 계산 단위 EL-101 EL101 ET-101


Capacity 350L ~ET101 150L
① 처리량/Batch [kg/B] 350 3.08 150
② 처리 Batch수 [B/Lot] 6 6 6
③ 처리량/Lot ① x ② [ug/Lot] 2.10E+12 1.85E+10 9.00E+11
④ Surface area [cm2] 53128 10977 41716
⑤ Carryover 10x10-6[ppm] 1.00E-05 1.00E-05 1.00E-05 1.00E-05
⑥ Coupon area 25[cm2] 25 25 25
⑦ MACO/swab ⑤x(③/④)x⑥ ug/swab 9882 421 5394
⑧ MACO/equip ⑦x④/(25 x1000) [mg] 21000 185 9000
Allowable Contaminant Limit
 Based on Therpeutic Daily Dose
 MACO= TDDprev x MBS/SF x TDDnext

- MACO: Maximum allowable carry over


- TDDprev: Std therapeutic dose of inv. prod
- TDDnext: Std therapeutic daily dose for next prod
- MBS: Minimum batch size for next prod
- SF: Safety factor (normally 1000 in calculations based
on TDD)
<Ref: APIC 2000: cleaning validation guidance>
Allowable Contaminant Limit
 Based on Toxicological Data
 NOEL= LD50(g/kg) x 70kg/2000
 MACO= NOEL x MBS/SF x TDSnext
- NOEL: no observed effect level
- 2000: an empirical constant
- TDSnext: Largest normal daily dose for next prod
- Safety factor : parental: 1000~10000
oral prod: 100~1000
topicals: 10~100

<Ref: APIC 2000: cleaning validation guidance>


What is being removed
 Active ingredient
 Decomposition product of active ingredient
 Microbial contamination
 Endotoxins
 Sanitizing agent
 Lubricant
 Environmental dust
 Residual rinse water
Type of Analytes
 Proteins: active, inactive but intact, fragmented protein, as
contaminating intra-/extra cellular protein

 Organic comp: cellular comp. DNA, RNA, endotoxin, car


bohydrate, lipid, other org compound

 Inorganic comp: process-/medium component, detergent

 Biol contaminat: mycoplasma, viral, bacterial, non viral ho


st bacteria
Specific Assays
 Cytotoxicity: to verify the detoxification of bacterial to
xin by heat inactivation

 Immunoassay: ELISA, specific but poor reproducible

 HPLC: protein, peptide, nucleic acid, small molecules


 accuracy, reproducibility, recovery rate very good,
1~2% SD

 PAGE: specificity is limited to protein size


Non-Specific Assays
 TOC: Determination of various compound or compo
und class 연소산화 (Pt)/ 습식산화 (uv induced)
 CO2NDIR 측정 by 1700cm-1

 Colorimetric protein assay: binding to dye(Blue G25


0), determine spectrophotometrically by 595nm
 Coductivity: simple and effective for measurement o
f residual inorganic material
 pH, UV/VIS
 TDS(Total dissolved solids)
Category of Analysis

Type of analyte Assays


Protein Bioassay, ELISA, HPLC
PAGE, Absorbance, TOC
Org compound TOC, HPLC, UV-Abs., TDS
Inorg compound Conductivity, pH,
o-Phosphate, ICP, TDS
Biol Systems Viable cell analysis
Commonly used anal. Method for biopharm
.Contaminants and Impurities
Impurities and TOC HPLC ELISA PAGE Lowry LAL Ion-
Contaminants Protein Exchange
Media + + - + + - +
Metabolites + + - - - - +
Endotoxin + - - - - +
DNA/nucleic acid + - + - - - +
Carbohydrates + + + - - - +
Lipids + + + - - - +
Proteins
Native + + + + + - -
Denaturated
+ + - - + - -
Stabilizers + + - - - - +
Cleaning agent
Organic + + - - - - +
Inorganic
+ - - - - - +

J. of Parental Science & Technology, 13-19(45), 1991


Analytical Method Validation
ICH Q2A/Q2B
 Accuracy
 Precision
 Linearity and Range
 Specificity (no need to perform by TOC-method)
 LOD/LOQ
 Intermediate precision
 Sample solution stability
 Allowable acceptance limit > LOQ
Cleaning Validation Protocol
 Objective
 Scope
 Reference inclusive SOP
 Responsibility
 Material and method
 Procedure
 Acceptance criteria: training, deviation, batch, …..
 Work sheet/equipment: cleaning procedure, raw
data record, sampling, analytical procedure, etc.
Cleaning Validation Report
 Introduction
 Summary:method
 Results: table
 Conclusion
 Recommendation
 Appendices: analytical raw data,
chromatogram, etc.

You might also like